Loading...
HomeMy WebLinkAboutPermit Building 2020-01-28Web Address: www.springfield-or. gov Building Permit Residential Structu ra I Permit Number: 81 1-2O-OOOO74-STR M Number: 811037905414 City of Springfield Development and Public Works 225 Fifth Street Springfield, OR 97477 541-726-3753 Email Address : permitcenter@springfield-or.9ov SPRINGFIELD $ Permat Issued: January 28, 2020 TYPE OF WORK Category of Construction: Single Family Dwelling Type of Work: Alteration Calculated Job Value: $30,966.60 Description of Work: Garage conversion into 2 bedrooms, enclosing existing laundry area JOB SITE INFORMATION Worksite Address 535 51ST ST Springfield, OR 97478 Parcel 1702332403202 Owner: Address: E STREET PROPERTIES LLC 7906 THURSTON RD SPRINGFIELD, OR 97478 LICENSED PROFESSIONAL INFORMATION Business Name WEILAND ELECTRIC DIVISION LLC - Primary License ccB License Number L75373 Phone 54t-747-770L PENDING INSPECTIONS Inspection 1999 Final Building 1220 Underfloor Framing/Post and Beam 1410 Underfloor Insulation 1430 Insulation Wall 1440 Insulation Ceiling 1260 Framing Inspection Group Struct Res Struct Res Struct Res Struct Res Struct Res Struct Res Inspection Status Pending Pending Pending Pending Pending Pending SCHEDULING INSPECTIONS Various inspections are minimally required on each project and often dependent on the scope of work. Contact the issuing jurisdiction indicated on the permit to determine required inspections for this project. Sched ule or track i nspections at www. bu ild i ng permits.oregon. gov Call or text the word "schedule" to 1-888-299-2821 use IVR number: 811037905414 Schedule using the Oregon ePermitting Inspection App, search "epermitting" in the app store Permits expire if work is not started within 180 Days of issuance or if work is suspended for 180 Days or longer depending on the issuing agency's policy. All provisions of laws and ordinances governlng this type of work will be complied with whether specified herein or not. Grantlng of a permit does not presume to give authority to yiolate or cancel the provisions of any other state or local law regulating construction or the performance of construction. ATTENTIONs Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules ar€ set forth in OAR 952-001-0010 through OAR 952-OO1-OO9O. You may obtain copies of the rules by calling the Center at (5O3) 232-L9A7. All persons or entitles performing work under this permit are required to be licensed unless exempted by ORS 7O1.O1O (Structural/ttlechanical), ORS 479.540 (Electrical), and ORS 693.O10-O2O (Plumbing). printed on: 1/28120 page 1 of 2 C:\myReports/reports//prcduction/01 STANDARD OREGON Ir \ Permit Number: 81 1-20-OOOO74-STR Page 2 of 2 Fee Description Technology Fee Plan Review - Minor, City Structural building permit fee Structural plan review fee State of Oregon Surcharge - Bldg (12olo of applicable fees) Quantity Total Fees: Fee Amount $45.18 $141.00 $462.22 $300.44 $ss.47 $ 1,004.31 1 Construction Type VB Printed on: 1/28120 Occupancy Type R-3 1&2family Unit Unit Cost Sq Ft $122.46 Total Job Value: Job Value $51,433.20 $51,433.20 C:\myReports/reports//prcduction/o1 STAN DARD Unit Amount 420.00 Page 2 of 2 PERMIT FEES VALUATION INFORMATION SPRINGFIELD $fr OREGON www.springfield-or.gov Worksite address: 535 51ST ST, Springfield, OR 97478 Parcnl: 1702332403202 Transaction Receipt 81 1 -20-000074-STR IVR Number: 811037905414 Receipt Number: 473648 Receipt Date= 1l28l20 City of Springfield Development and Public Works 225 Fifth Street Springfield, OR 97477 541-726-3753 perm itcenter@spri n gfield-or. gov Transaction Units date 1128120 1.00 Ea Description Structural building permit fee State of Oregon Surcharge - Bldg (12o/o ol applicable fees) 224-00000-425602-1 030 82 1 -00000-21 5004-0000 1 00-00000-425002-1 039 204-00000-425605-0000 1t28t20 1.00 Ea 1t28t20 1.00 Ea Plan Review - Minor, City 1t28t20 1.00 Automatic Technology Fee Fees Paid Account code Fee amount $462.22 $141 .00 $45.1 I Paid amount $462.22 $55.47 $141.00 $45.1 8 Payment Method Credit card authorization: 065557 Payer: Jess Brandtdrury Payment Amount:$703.87 Cashier: Katrina Anderson Receipt Total:$703.87 Printed: l/28120 10.24 am Page 1 of 1 F I N_TransactionReceipt_pr $55.47 Ctry or SpRINcFIELD, oREGoN Structural Permit Application ffi225 Fifth Street o Springfield, OR 97477 ) PH(541)726-37 53 . FAX(54 I )726-3689 This permit is issued under OAR 918-460-0030. Permits expire if work is not started within 180 days of issuance or if work is suspended for lE0 days. ovl BUt ubt lJ 2 Tv3 r\ $ LO uti lil n,lw lD il >8 (7o J\Ao-"fu'(,...LD ar(e\ DEPARTMENT USE ONLY Permit no Date: 1 trz )$D LOCAL GOVERNMENT APPROVAL Date: This project has final land-use approval. Signature: This project has DEQ approval. Signature:Date: Zoning approval verified: E Y". E No Property is within flood plain: ! Yes E No CATEGORY OF CONSTRUCTION I Government ! Commercialfl Residential JOB SITE INFORMATION AND LOCATION Jobsiteaddress: 19f .5t{ gtrc-z-7 ZrP:1772'L State: Qr Lot no.: f Subdivision: Taxlot:r*, ?.707Reference: \T243?q PROPERTY OWNER I State/ r Address: Name: Fax:Phone: 9!c/1dtq fro9l ( Building 0wner or authorizing this application E-mail: Sign here: [} tt i, iirtuttution is being m1-de on residential or farm property owned by me or a member of my immediate family, and is exempt from licensing requirements under ORS 701 .010. GoNTRACTOR INSTALL4TTON Business name Address ZIP:City:State: Phone:Fax: E-n-rail CCBlicenseno.: \-l 6'%7 3 Print name Signature: FEE SCHEDULE 1. Valuation information A.,e/Srk-_-a) lr'S (a) Job description: Occupancy Construction type Square feet: Cost per square foot: Other information: Type of Heat: C/.cf-,.- Energy Path: ! ne* @alteration E addition (b) Foundation-only permit? ! Yes E No $t(,{ }}.Total valuation: ' 2-O,t11n1o.12. Building fees (a) Permit fee (use valuation table):$ $(b) Investigative fee (equal to [2a]): (c) Reinspection ($ per hour): (number ofhours x fee per hour)$ $(d) Enter I 270 surcharge (.12 x l2a+2b+2cl): (e) Subtotal of fees above (2a through 2d):$ 3. Plan reYiew fees $9o o .qq(a) Plan review (65% x permit fee [2a]): $(b) Fire and life safety (65% x permit fee [2a]): $(c) Subtotal offees above (3a and 3b): 4. Miscellaneous fees $(a) Seismic fee, lYo (.01 x permit fee [2a]): $(b) Tech fee,5%o (.05 x permit fee[2a]+PR fee [3c]) ( tr'OTAL fees and surcharges (2e+3c+4a+b) SUBCONTRAGTOR INFORMATION Name CCB License #Phone Electrical [,/,-lo.rJ Z/c-cfr,- Plumbing Mechanical Lasr cdircd 5-5-2019 BJoncs \I:A Yr€f,'{waft zt|gtrzCity: e'--- o-, i.) SPRINGFIELD b Transaction Receipt 811-20-000074-STR lVR Number: 8'l'1037905414 Receipt Number: 473512 Receipt Date:1113120 City of Springfield Development and Public Works 225 Fifth Street Springfield, OR 97477 54L-726-3753 perm itcenter@springfi eld -or. govOREGON www. sprin gf ield-or. gov Worksite address: 535 51ST ST, Springfield, OR 97478 Parcnl 1702332403202 Transaction Units date 1l13l2j 1.00 Ea Description Structural plan review fee Fees Paid Account code 224-00000-425602-1 030 Fee amount $300.44 Paid amount $300.44 Payment Method Credit card authorization: 041 549 Payer: E STREET PROPERTIES LLC Payment Amounl:$300.44 Cashier: Katrina Anderson Receipt Total:$300.44 Printed: 1/13/20 9:09 am Page 1 of 1 Fl N_TransactionReceipt_pr -1\t Business Registry Business Name Search Page I of2 0t-28-2020 10:28 ORT.GON SECBI.IARY OT SIAII HOME ill ) Corporation Division buslness informatlon oregon buslnese gulde referral llst buslness reglstryrrEncwal iorms/fees no{ary publlc unllorm commercial code unltorm commerclal code search documefits E data servlces Business Name Search New Search printer Friendrv Business Entity Data burlness name search Registry Nbr Entity Typ.e Entitv Status Jurisdiction Registry Date Next Renewal Date Renewal Due? t093340-94 DLLC ACT OREGON 03-09-20 1 5 03-09-2021 Entity Name E STREET PROPERTIES LLC Foreign Name Type PPB PRINCIPAL PLACE OF BUSINESS Addr 1 7906 THURSTON RD Addr 2 STATES OF AMERICAmcsz478GFIRItlnF,rfitlN New Search Printer Friendlv ASSOCiated NameS Please click here about and service .ts, STERED AGENTG Start Date 015 -09-Resign DateTyPE RURYNEIiitI Addr 1 7906 THURSTON RD Addr 2 csz 478Gtil nin'l STATES OF AMERICA nlllrt'EilMTOETrf,r $Eiti![GrlnrrN ItTilirfitl Type G ADDRESS Addr 1 7906 THURSTON RD Addr 2 csz 1p7478G STATES OF AMERICACosririrGrHrrot Type AGER Resign Date Name SS URY Addr 1 7906 THURSTON RD Addr 2 csz l9t+tsG Co TED TATES OF AMERICAs[rIilGItilIDOil http://egov.sos.state.or.us/br/pkg_web_name_srch_inq.show_detl?p_be_rsn:1750137&p_s... 112812020 h Business Registry Business Name Search New Search Printer Friendlv Name HiStO Please read before ordering Copies. New Search Printer Friendlv S Histo Page 2 of 2 Business Entity Name ET'E End Date E STREET PROPERTIES LLC EN quillo3-oe-2ots EffifrTE-iiilElffi-tcrir ActionImage I Availabld fransaction Date Effective Date Status Name/Agenl Chanqe Dissolved By ^fb, IAMENDED ANNUALfu! hsponr 0t-27-2020 FI r,fi, IMENDED ANNUALEr Rpponr 0t-28-2019 FI h.pponr 03-30-2018 FI , hNAENDED ANNUAL''' h.rponr 02-28-2017 FI ' h.pponr 02-29-2016 FI 4m\ lanrtclps orbt lcncaxrzATroN 03-09-201s FI Agent About Us lAnnouncements I Laws & Rules I Feedback Policy I SOS Home I Oreoon Blue Book I Oreqon.qov For comments or suggestions regarding the operation of this site, please contact : corporation.division@state.or.us @ 2020 Oregon Secretary of State. All Rights Reserved. http://egov.sos.state.or.us/brlpkg_web_name_srch_inq.show_detl?p_be_rsn:1750137&p_s... 112812020 eoDRess : 535 5lA S-nzeer Plan Review Checklist MAP & TAXLOT : t-?- ()2--43^ 24 - O3ZoZ- PERMIT #: Za-o@ -14 - 3-(f\-- a B st tr * En II m w ts gt, U, Enter data into project log Check address on plans is correct Check to see if LDAP has been issued. LDAP Permit # Read all cemfn_ents from other work groups to see if anything needs to be considered during structural review. No aoerrsn tS:..tt Check Setbdifts on Site Plan Check RLID tO make sure taxlot matches what is shown on drawings, that topography lines are on the plans and that owner info matches Check to see'if lot is sloped or flat - lf sloped, will back deck meet setbacks lf a new home is being built at Mountaingate or River Heights,check the subdivision books to see if a Geo-Tech Check soils to determine whether or not a Geotechnical evaluation should be required lf property is^on septic, check for proper setbacks from building to tank, distribution box, and leach field Make sure that property is not in Flood Hazard A affected property according to Mapspring (if it is wenl-lo Check that everything required to be engineered has engineering and that the stamp is current brE L'<r- €eE; A SEL\rt<-E L-ATEn^L- SCL4JE L =)t f rs&Str^.,6 Check the truss package and make sure it matches the plans (qty of trusses, type, attachements) - lf the numbering doesn't *match but the uplift and reactions look correct it is OK. Falls under field verify xMake sure that if there is HVAC equipment in the attic, the trusses were designed to support it Ttca? overhang to make certain they don't project farther than allowed for fire s'eparation -' " -t ..{, inches rafter framing, check spans lf trusses or rafters are 2172 or 3/12 pitch, make sure that "duel layers of underlayment required" note gets on plans. Less than 2/12 needs to be a membrane roof. eck to see if anything over 4000lbs is bearing down on stiip footings. lf so this needs to be enlarged Check Hold Downs, highlight hold downs for the inspector Check Foundation Venting Check for propane tanks; look for setbacks, siesmic attachments, and protection of the tank. Make notes on plans with stepped foundations how far back they need to be from the edge of the cut and the uphill cut Check header sizes Check footing sizes Make sure that if rebar is used that it has minimum cover depths. Check energy code requirements. Additional energy measure selections : *Make sure that insulation called out meets the energy code a E nvel0p#)aneeme nt- Conservatio n M eas u re make note of the required R value ry courxrc"g:Djo\)sEFfi<- u vl n ,i MY' VI fr ft ilT 'Inx L W n v! E TEs ta EII ifr n ITg MYI n!,au 8 *on additions/remodels where existing conditions come tnt6 ptai, lAe lbA" section N11d..3 & table rririof .i Check tempered glazing (hazardous locations, windows in stairwell, within 24" of door, where a door would open into the glass,etc) Check bedrooms for egress (window sizes, make sure that garage door to house doesn't go into bedrooms) Check to see if there is a living area above the garage, if so, make note of 5/8" type X gyp board fire separation requirement. Check for mechanical equipment protection (bollards) in the garage lf DETACHED garage is being built less than 3ft to existing structure it needs to have 1/2 gyp board on the interior walls lf Garage is elevated, make sure columns supporting underfloor of garage are continous to footing (make note on plans) Check fire/sound separation assembly on 2 family dwellings Check for smoke alarms/Carbon Monoxide alarms (look on electrcialsheets if there aren't any shown on floor plan) Check wall bracing Check minimum room size l/q" = l' (S...=o Sr.rx-csz ,^r^,<-_ | t-r,s . ygrr- 5 )ke sure that minimum bathroom fixture distances are met eck to make sure stairs meet code Check roofing material (composition shingles, Spanish tile, metal, etc.) Check for attic access and underfloor access on plans Aepcrsr6 Fefir_ wt / Z@1. 4Er'- trpc^rOC-€ Check beam sizes Read over all the general notes to make certain that nothing was missed and there are no conflicts F new SFD or ADU , make sure that Willamalane form is attached Transfer all notes made by other work groups untilthere are two identical sets of plans (jobsite and city se!),.." lnclude standard attachments : Exte rior WaI E nve I ope SelI:Cqrtif ication Fo rm Moisture Content Acknowledgement Form High-Efficiencv Liehtins Svstems Oreeon Residential Specialtv Code (ORSC) Noise Ordinance Notice Smoke Alarm Ventilation Requirements for Kitchens and Bathrooms Green Approved Plans Cover Sheet (Found under "Cover" in file cabinet) Make sure that on all new square footage, that a Fire SDC is charged. Add all inspections and fees into Accela (including Willamalane fee and addressing fee) Stamp plans with the "Reviewed for Code Compliance" stamp, sign the approved by line and perforate Approve Building Review line in Accela & call or email application with fees due and attach placard to jobsite set * Enter energy path data from Additonal Energy Measures Table N110L.Ll2l into Accela t'...'i, t..'... ' t { '! I x a.L E EI r . 3:' .-i '! - . .....'. .i' I.'i ,.- - ' ,?(Not required for unheated detached structures) I , 3 H Signed electrical application received Print out the Fee Schedule and put it with the Wiilamalane Spreactqh Put any inspection notes into Accela that need to be there before the plan is issued. Check off Project Log and enter today's date. Plan check items/notes V^^u Str-g r\rslGrt{g Asorrrr.r.rrt Exgnzrr Meae.rJ\€ S -lxI ENERGY EFFICIENCY TABLE N1101.3 SMALL ADDITION ADDITIONAL MEASURES (Select one) Increase the ceiling insulation of the existing portion of the home as specified in Table N110L.2. 2 Replace all existing single-pane wood or aluminum win- dows to the U-factor as specified in Table N1 LOL.2 3 Insulate the floor system as specified in Table Nl101 .2 & install 100 percent of permanently installed lighting fix- tures as CFL, LED, or linear fluorescent or a min. efficacy of 40 lumens per watt as specified in Section N1L07 .2. 4 Test the entire dwelling with a blower door and exhibit no more than 6.0 air changes per hour @ 50 Pascals. 5 SeaI and performance test the duct system. 6 Replace existing 78 percent AFUE or less gas furnace with a92 percent AFUE or greater system. 7 Replace existing electric radiant space heaters with a ductless mini split system with a minimum HSPF of 10.0. 8 Replace existing electric forced air furnace with an air source heat pump with a minimum HSPF of 9.5. 9 Replace existing water heater with a water heater meet- ing Conservation Measure D [Table N1101 .I(2)] *SCsfrr oVAr-- €utctr-a,--7 H tz6Ste ltlcJ EHAPTER 1 1 ENERGY EFFICIENEY (All of Chapter I l is Oregon amendment) PART I ENERGY CONSERVATION sEcTrot{ N1101 SCOPE N110L.L General. The provisions of this chapter regulate the exterior envelope, as well as the design, construction and selection of heating, ventilating and air-conditioning systems, Iighting and piping insulation required for the purpose of effective conservation of energy within a building or struc- ture governed by this code. AII conditioned spaces within residential buildings shall comply with Table N1101.1(1) and two additional measures from Table N110i.1(2). Exceptions: 1. Application to existing buildings shall comply with Section N1 101.2. 2. Application to additions shall comply with Section N1101.3. 3. Heated or cooled detached accessory structures that are not habitable shall meet the following envelope requirements without any additional measures: Walls: R-21/U-0.064; Roofs: R-38/U-0.027 (attic) or R-20 continuous insulationrU-0.048 (above deck); Windows: U-0.35; Opaque doors: U-0.70; Roll-up doors: U-0.50. N1.101.2 Application to existing buildings. Alteration and repairs, historic buildings and change ofuse or occupancy to buildings, structures or portions thereof shall comply with the requirements in Sections N 1 1 0 1 .2. 1 through N1 1 01.2.3. N1101.2.1 Alteration and repair. Alterations and repairs affecting energy conservation measures shall conform to the requirements specified in this chapter. Alterations or repairs which affect components of exist- ing conditioned spaces regulated in this chapter, those components shall comply with this chapter. Exception: The minimum component requirements as specified in Table Nli01.2 may be used to the maxi- mum extent practical. N1101.2.2 Historic buildings. The building official may modify the specific requirements of this chapter for tris- toric buildings and require in lieu thereof alternative requirements that will result in a reasonable degree of energy efficiency. This modification may be allowed for those buildings specifically designated as historically sig- nificant by the state historic preservation office(r) or by official action of a local government. N1101.2.3 Change of occupancy or use. Definition of "Change of use" for purposes of Section N1101.2.3 is a change of use in an existing residential building and shall include any ofthe following; any unconditioned spaces such as an attached garage, basement, porch, or canopy that are to become conditioned spaces; any unconditioned, inhabitable space that is to become conditioned space, such as a large attic. N1101.2.3.1 Change of use. A building that changes use, without any changes to the components regulated in this chapter, is required to comply with Table Ni101.2 to the greatest extent practical. Changes of use that are greater than 30 percent of the existing building heated floor area or more than 400 square feet Q7 r#) in area, whichever is less, shall be required to select one measure from Table N1101.3. N1101.2.3.2 Change of occupancy. Alteration and repair ofconditioned nonresidential buildings, such as a small church or school, that are changing occupancy to residential shall use Table N1101.2 to the greatest extent practical and select one measure from Table Nl101.1(2), or one measure from Table Nl101.3. Exception: The minimum component requirements shall be disregarded when thermal performance calcu- lations are completed for change of use to Group R occupancy, when such calculations demonstrate simi- larperfonnance to therequirements of Table N1 i01.2. TABLE N1101.2 EXISTING BUILDING COMPONENT REQUIREMENTS BUILDING COMPONENTS REQUIREO PERFORMANCE EAUIV. VALUE Wall insulation u-0.083 R-i5 Plat sgiling u-0.025 R-49 Vaulted ceiling > 10 inches nominal rafter depth u-0.040 R-25 Vaulted ceiling > 8 inches nominal rafter depth u-0.047 R-21 Underfloor > 10 inches nominal joist depth u-0.028 R-30 Underfloor > 8 inches nominal joist depth u-0.039 R-25 Slab edge perimeter F-0.52 R-15 Windows u-0.30 u-0.30 Skylights u-0.60 u-0.60 Exterior doors u-0.20 R-5 Exterior doors with > 2.5 ftz glazing u-0.40 R-2.5 Forced air ducts nla R-8 tl 2017 OREGON RESIDENTIAL SPECIALTY CODE For SI: inch = 25.4 mm, 1 square foot = 0.0929 m2, 433 SMITH Thayne From: Sent: To: Subject: Michael Drury < mbrandtdrury@hotmail.com > Thursday, January 23,2020 2:12 PM SMITH Thayne Re: Message from " RN P00267 3 A804C9" thanks for your time michael From: SM ITH Thayne <tsmith @springfield-or.gov> Sent: Thursday, January 23,2O2O 1:25 PM To: Michael Drury <mbrandtdrurv@hotm > Subject: RE: Message from "RNP002673A804C9" Not double paned OR now double paned? I think that energy code requires double paned glazing on windows in heated spaces. I will double check that. But regardless, it would need to meet U0.30 based on the table that I sent you. Do you have anything from the window manufacturer indicating that it meets that U-value that you could send me? Thayne From: Michael Drury lmailto:mbrandtdru l Sent: Thursday, January 23,2020 11:44 AM To: SMITH Thayne Subject: Re: Message from "RNP002673A804C9' Thayne, I am going with Energy path Measure 2 and replacing windows that are not double-pane vinyle thanks Michael Drury From: SMITH Thayne <tsmith@springfield-or.gov> Sent: Thursday, January 23,2O2O 11:34 AM To: mbrandtdrurv@hotmail.com <mbrandtdrurv@hotm > Subject: FW: Message from "RNP002673A804C9" Choose one option from Table Nl 101.3 and email me your choice. Once I have that, I can approve the plans. All I have is a structural permit application however so there isn't an electrical, mechanical or plumbing permit included. Are your sub- contractors pulling those? Thayne Smith Plans Examiner City of Springfield 225, 5th Street 1 Three of the windows in this house the pane seal has failed and the windows need to be replaced but to speed this along and since we are blowing r49 into garage anyway we will upgrade all of house to r49 and go with energy efficient measure 1 Springfield, OR 97477 tsrnith@sprin gfi eld-or. gov P - 541-726-3183 F - 541-726-3689 2