At your request the Building Division of the Cjty of Springfield
made an occupancy inspection to chanqe the use of 52 South 17th
Place, Sprjngfield,0regon, from an R-1 structure to a B-2 use.
The following items must be repaired or replaced to conform with
the Un'iform Housing Code as adopted by the C'ity of Springfield:
The entjre building shall be rewired to conform with the
1978 National Electnical Code.
2. The Restroom floors must have a smooth, hard, nonabsorbent
surface which extends at least 5 'inches up the wall.
3. Att'ic ventilatjon must be jnstalled, l/150 of the square
footage shall be net free vent'ilation.
4. An 18'inch X ?4 inch crawl space door shall be provided.
All necessary permit shall be obtained before work starts and all
work shall be accomplished according to applicable codes and inspected
before a Certificate of Compliance will be 'issued.