HomeMy WebLinkAboutPermit Building 1996-01-11RESIDENTIAL
PERMIT APPLICATION
lnspections: 726-3769
Office: 726-3759
LOCATION OF PROPOSED WOFIK:
SPRT}\lGFIELO
JOB NUMBER
225 Fif th Street
Springfield, Oregon 97477
TAX LOT zaoASSESSORS MAP:/7 ^=/^ y
LOT:
-
BLOCK:SUBDIVISION:
--_
PHONE:
STATE ZIP:\.-?qCITY:
ADDRESS:
OWNER:
NEW
--
REMODEL -Y ADDITION DEMOLISH OTHER
DESCRIBE WORK:
ADDRESS EXPIBES PHONE
CONTRACTOR'S NAME
MECHANICAL
ELECTRICAL
CONST,
CONTFIACTOR #
GENERAL:
PLUMBING
_ OFFICE USE -
LAND USE:
# OF UNITS: ._---
FLOOD PLAIN:
ZONING CODE:
, OF BDRMS: -_-
WATER HEATER:
OUAD AREA:
r OF BLDGS:
SECONDARY HEAT:
SQUARE FOOTAGE:RANGE:
OCCY GROUP;
* OF STORIES:
CONSTR. TYPE;
HEAT SOUFICE:
To request an inspectlon, you must call 726_3769. This ismade the sante working day, lnspections requested afte
Temporary Eleclrlc
Rough Electricat - prior to
cover.
Electrical Service - Must beapprovect to obtain permanent
electrlcal power.
Final Electrlcal - When ailelectrical work is complete.
Flnal Mechanicat - When ailmechanical work ls complete,
Final Building - When altrequlred lnspecUons have beenapproved and building iscompleted.
a24 hour recordlng. Ail rnspecilons requested before 7:00 a.m. wirr ber 7:00 a.m. will be made the lollowing work day.
REOUIRED INSPECTIONS
Rough Mechanlcal - prior to
cover.l--l Finat ptumbing - When atr.J plumbing work ls complete.
Site lnspection - To be made
af ter excavation, but prior tosetting fc.rrms.
I--l Unaerslab ptumbing/ Electricat /
-
Mechanical - prlor to cover.
w
B
E
Footlng - After trenches areexcavated.
Masonry - Steel locailon, boncl
$ffi*tP*zz
Foundatlon - After forms areerected but prior to concreteplacement.Wall/Ceiling lnsulation - prlor tocover.
Underground plumbing - prior
to filling trench.
l--l Underiloor plumblng/Mechanlcal
Prior to insurailon or oec[rng. l-l wooa Srovo - After lnstailatron
MOBILE HOME TNSPE TIONS
lnsert - After flreplace approvaland installation of unlt.
'[-l Alocking and Ser.Up - When all
-
btocklng is complete.
Plumbing Connections _ Whenhome has been connected towater and sewer,
Sidewalk & Driveway - Afterexcavation is complete, formsand sub-base malerial in place.
Electrical Connection _ When
P_lg!k,lg, ser-up, and plumbinjtnspections have been approvedand the home is connected tothe service panel.
Curbcut & Alrproach - Afterforms are erected but prior toplacemcnt of concrete.
Fence - When completed.
[-_] Street Trees - When ail required
-
trees are planted.
Final - After all requiredrnspectlons are approved andporc.hes, sklrting, decks, andventing have been lnstalled.
q
[-l Fireplace - prtor to factng.J materlals and framing lnspl
l--l Framlng - prlor to cover.
[--l other
l-l Drywail - prior to taping.
l-l post and Beam - prlor to ftoor
-
lnsulatlon or decking.
l--l Ftoor ln.ururlon - prior tou decking.
fl Sanitary Sewer - prior to fiilin9
-
lrench.
[l Srorm Sewer - prior to fiilingu trench.
f]l Warer Line - prior to filingu trench.
[-l Rougtr plumbing - prior rou cover.
Lot faces
Lot sq. ftg.
Lot coverage
Topography
Total helght
Lot TYPe'-
-
lnterior
-
Corner
-
Panhandle
-
Cul-de-sac
Setback
P.L.HSE GAR ACC
N
S
E
-lS THE PROPOSED WORK iN THE
HISTORICAL DISTBICT, OR ON
THE HISTORICAL REGISTER? --
lf yes, this application rnust be signed
and approved by the Historical-
Coordinator prior to permit issuance,
APPROVED:
BUILDING VALUE, PLAN CHECK
AND BUILDING PERMIT
This pcrmit is qranted on the express condition that the said
construction slterll, in all respects, conform to the Oldinance
adopted by thc City of Springfield, including the
Development Cocle, regulating the construction an(l use of
buildings, anrl may lte suspended or revoked at any tlme
upon violation of any provisions of said ordinances.
,t
Reoeipt Nutnbcr:-.-
Plans Flcviewcd By Date
Plan Check Fee:
Date Paid
Received By:
VALUE
a<d' effiuttry(A)
X $/SQ. FT,
Total Value
Building Permit Fee
State Surcharge
Total Fee
BUILDING PERMIT
ITEM SO. FT.
Main
Garage
Carport
Systems Developmcnt Charge is due on all undeveloped
properties within thc City lintits which are being improved.
SYSTEMS DEVELOPMENT CHARGE (SDC)
(B)
ADDITIONAL COMMENTS
FEE
(c)
No
FT.
FT.
PLUMBING PERMIT
Plumbing Permit
State Surcharge
Total Charge
ITEM
Fixtures
Residential Bath(s)
Slnitary Sewer
I
Water
. FT.
Storm Sewer
Moblle Home
Wood Stove/ lnsert/ Flreplace Unit
Dryer Vent
(D)
N0Vent Fan
Mechanical Permit
lssuance
State Surcharge
Total Permlt
MECHANICAL PERMIT
Furnace
Exhaust Hood
By slgnature, I state and agree, that I have caref ully examlned
the completed application and do hereby certify that all
lnformation hereon is true and correct, and I f urthcr certlly
that any and all work performed shall be done in accordance
wlth the Ordinances of the City of Springfield, and the Laws
of the State of Oregon pertalning to thc work descrlbed
herein, and that NO OCCUPANCY will be made of any
structure without permission of the Buildlrlg Safety Divislon'
I further certily that only contractors and employees who
are ln cotnpliance with ORS 701.055 will be used on thls
proiect.
I further agrce to ensure that all required inspections are
requested at the proper tlme, that each address is readable
from the street, that the permlt card ls located at the front
I tim
Sign
app roved
Date
I
s will remalnof the proPertY,
on the site
MISCELLANEOUS PERMITS
Moblle Home
State lssuance
State Surcharge
Sidewalk --- ft
Curbcut _--_ ft
Demolition
State Surcharge
Total Miscellaneous Permits (E)
TOTAL AMOUNT DUE (excluding electrical)
(A, B, C, D, and E Comblned)
%'fr
VALIDATION:
RECEIPT NUMBER
DATE PAID
AMOUNT RECEIVED
BECEIVED t]Y
1. One story foot,ing: L2" wide
A11 footings sha11 be a minimum of 5" thick, ext,end a minimumof 12tt below finish grade, and have a minimum 6n Ehick
foundation stem waI1. (Figure No. R-303).
Individual concrete piers shalL be a minimum of 8 rr t,hick forpiers having a maximum dimension of 24 inches square, and
shall increase in t,hickness for piers of larger dimension and
be of adequate size to support imposed t,ributary loading.(Table No. P.-602.2, 1b).
Foundation walls shall extend at least 8" above finished grade
adjacent to the foundation at all point,s, except where masonry
veneer is used. (R-304.2) .
2
3
aIiri4Ground under building shal1 be sloped tounderfloor drain installed to provide pos
the area under t,he building.
ow point, and an
ve drainage from
(R-311 .4 ) .
5 Provide a/2" diameter steel bolts embedded at least into
reinforced grouted masonry. Maximum spacing shalI be 5'-0tr on
center with a minimum of two bolts per piece of plate or sill,
and 1 bolt within 12" of each end.(table R-303) .
Provide net free ventil,ating area not less than 1 square foot
for each 150 square feet, of crawl space area. One such
ventilating opening shall be within 3' of each corner. Vents
shall be covered with minimum 1/4" and maximum 1/2rr corrosion
resistant wire mesh. (R-311.1).
Provide 5 mil black polyethylene ground cover, lapped 12!r atjoints. (oSsC s303 (f)s) .
Provide 12" clearance to grade from underside of girders, and
beams and minimum of l-8" clearance to grade from underside ofjoists and floor. (R-309.1,1) .
6
7
I
9 Provide 31r minimum
masonry or concrete,
end.
end bearing for girders supported bywith L/2u air space on top, sides and
(R-502 .3, R-309 .t,4l .
10.Provide minimum under-floor acces,s opening of 18'r x 24't.
(R-311.2) .
NOTE: PERITIIT APPROVED FOR PERII{ETER FOOTING A}ID CONCRETE BLOCK
FOI'IIDATION WATL ONIJY. O$nIER CAI{NOT DETERMINE III'TERIOR SUPPORT
REQUIRE}IENTS IIIITIIJ BOUSE IS iIACKED UP, DI'E TO INADEQUATE CRAI{IJ
SPACE. OYINER SIIALIJ CONFIRITI IIITERIOR SUPPORT REQUIREI{EIITS, AI\ID
SI'BMIT PIJA}I FOR APPROVAIJ PRIOR TO PROCEEDING WITE INTERIOR PIERS '