HomeMy WebLinkAboutBuilding Correspondence 1980-02-04{\
PUBLIC WORKS
CIIfTf OE- SPF,II$GFIEITD
SPRINGFIELD, OREGON 97 477
February 4, 1980 346 MAIN STREET
726-3753
CERTIFIED LETTER
Mr. Charles L. Larson
261 East 12th Street
Eugene, Oregon 97401
Dear Mr. Larson:
As a result of tenant complaints and a request from the Springfield Fire
Marshal's office, the structure located at L47 and L471< North 17th Street,
Springfield, Oregon was inspected on January 23,1980 by the City of
Springfield Building Division.
The following items were found to be in violation of the Uniform Housing
Code as adopted by the City of Springfield:
1. The pressure relief valve drain on both water heaters, has been reduced
in size. The pipe nust be fulI size and piped to the outside of the
house in a visible .location.
2. The plumbing fixtures are leaking and loose.
3. P.V.C. water service is freezing due to exPosure to the weather'
4. The hot water pipes are cross connected at rthe water heaters.
5. There is a lack of adequate ventilation in the bathrooms.
6. The back door exit is inadequate and dangerous. Exit stairway nust be
constructed with a maximum rise of eight inches and a nine inch minimum
run.
7, There is evidence of infestation by insects and rodents.
8. There is deterioration of flooring and structural supports in bathroom
area.
9. There is excessive water damage and deterioration of perimeter exterior
wal1s, wal1 coverings and waIl supports.
10. IVaterproofing of the roof covering in unit 147 ts ineffective'
11. Windows do not open freely to provide proper ventilation and a proper
means of egress.
tii. Charles Larson
Page 42.
1,2. Main services to be properly wired with four conductor subfeeder cable to
subpanels. lr{ain disconnects are required.
13.
14.
15.
16.
Subpanels shal1 have isolated neutral systems.
Branch circuits to be properly protected by tt5tt type fuses.
The porch area to be continuous between back doors of duplexes to maintain
prop"1 height of service panels from porch f1oor, and be accessible from
either of the back doors.
Electrician sha11 make arrangments with the electric Power conpany to raise
the service drop to three feet above the house roof gutter.
L7. Baseboard heaters sha11 be properly bonded.
18. Remove/relocate receptacles above baseboard heaters.
19. Replace defective dryer and range outlets, and provide metal raceway pro-
tection on cables through floors.
20. Install a grounding type receptacle for the washing machine, the bathroom
and kitchen sink.i". lre.eptacle now located above bathroom sink to be re-
moved) .
2t. Defective light fixtures in bedrooms, bathrooms, livingroom, kitchen and front
and back porches to be properly repai.red or replaced (surface nount type by
bathroom door to be removed).
22. Replace defective wiring in ranges and install switch control knobs where
required.
23. Remove grounding tfpe receptacles
grounding conductor.
installed on two conductor cables without
24. Electrical contractor labe1 required'
Permits for repair and/or replacement must be applied for by 10 days from the date
of this letter ifuUr"ury 14, 1980). Repaii and/or replacement work must commence
within 24 hours afil, plrniis for the work are isssued'
If permits are not appliea !9r^!r February 14, 1980, the structure will be posted
,,',BSTANDARD BuILDING--D. Nor oc'cupy,,and ti" a"rrnis will be given 24 hours notice
to vacate the structure'
Please direct aIl inquiries to the Springfield Building Division at 726-3753'
Sincerely,
Dave Puent
Building Inspector
0P:SJ/1j