Loading...
HomeMy WebLinkAboutPermit Electrical 2002-07-31U Page 1 of2 SPRIN(lFIELD Job# 02-00880-01 COMMERCIAL PERMIT City Of Springfield Community Services Division Building SafetY 225Fifth Street Springfield, OR97477 Location Of Proposed Site: 245 00014th St Spr AssessorsMap#: 17033623 Lot: Block: Addition: Job Number: 02-00880-01 Office: 726-3759 lnspection Line: 726-3769 Tax Lot#: 13600 Subdivision: ctrY oF SPRINGFTELD, OREGON Owner: United Pentecostal Church Address: 24514th Street Scope Of Work: Electrical Only New service and additionalcircuit Phone Number: City/State/Zip: Alteration 541-747-5122 Springfield, OR97477 Value: $0 Contractor Type ElectricalContr Mechanical Contr Contractor Philips Electric lnc '1298 Bethel Dr, Eugene, OR 97402-2003 David Bragg 201 S Harrison, Newberg, OR 97132 Registration # 458 Expiration Date 511t2003 Phone 541-688-6121 503-554-17141354415t25t2003 Quad Area: # Of Units: Constr. Type: Water Heater: Office Use - Land Use: Zoning Code: Bedrooms: Range: Required lnspections Electrical -Prior to cover. -Must be approved to obtain permanent -When all electrical work is complete. -Prior to cover. -When all mechanicalwork is complete. #OfBu To request an inspection call the 24 hour recording at726-3769. a.m. will be made the same working day, inspections requested working day. 7:00 e the following Rough Electrical Electrical Service Fina! Electrical Rough Mechanical Final Mechanical Mechanical g\\\,e power. \s \e Job# 02-00880-01 # Of Stories: Height (feet): Current Units: Proposed Units: Census Code: Does not apply Total: Page 2 ol 2 Gonstruction Types: Occupancy Groups: # Of Buildings: # Of Bedrooms: Handicap Access? Area (Sq. Feet) Main:Accessory: Fee Paid On Receipt# Value/Quantity Fee Amount Electrical Minimum Electrical Permit Fee Permanent: 201 to 400 Amps Branch Circuits With Feeder or Service State Surcharge - Electrical 8% Admin Fee - Electrical Total Electrical 07t23t2002 07t23t2002 07t23t2002 07t23t2002 07t23t2002 10016 10016 10016 10016 10016 1 1 $.00 $75.00 $3.00 $5.46 $6.24 $89.70 Mechanical Minimum Mechanical Permit 8% Administrative Fee - Mechanical Less than 100,000 BTU Mechanical lssuance State Surcharge - Mechanical Total Mechanical Signature 07t31t2002 07t31t2002 07131t2002 07t3112002 07t31t2002 10109 10109 10109 10109 10109 $33.00 $3.60 $12.00 $10.00 $3.1 5 $61.75 $151.45 Date 1 :_"/il6 @ IVIEf ER (. tT q t\ t s \{ j s ,/ { {ltlv) a ?-€{+(N5-o:60N o sa >- g;d AONO o r-q .J:.;.4l>'lir ,J \ r I $t i I ii SppP hh. BI '.'t a(l ql s( ?o Ls L $ tvl a ": 1'-6" Drawn: Approved: Date: Job Number: Proiect: United Pentecostol Church 245 N 14fh Strcst Sf irytield, O.zgor 97 477 201 S. Harrison Naruberg, Oregon 97'132 50&55+1714 503€54-1834 fax Integra t*ruice Co. Sc"ea.e Ofli@ tLtcF4 GhsRml SarEtary i w //, 'a/ /'/ rbg cfh Oass Room 4 -) chs Rodn 5 ZZo eftu\ Ch$Rm l6g cF+\ WmRGtrm 'r',/ cFu i(-)tlEj HVAC Load Calculatians for United Pentecostal Church 245 N. 14th Street Springfield, Oregon 97 477 $ervice Go. Prepared By: Dave Bragg lntegra Service Co 201 S. Harrison Newberg, OR 97132 503-554.,t714 Tuesday, July 30, 2002 lcenera Project Filename: C:\Elite\Rhvacr,v\Projects\Springfield UPC.rhv Project Title: Designed By: Project Date: Client Name: Client Address: Client City: Client Phone: Company Name: Company Representative: CompanyAddress: Company City: Company Phone: Company Fax: Company E-Mail Address: Dave tsragg July 12,2002 United Pentecostal Church 245 N. 14th Street Springfield, Oregon 97 477 541-747-5122 lntegra Service Co Dave Bragg 201 S. Harrison Newberg, OR 97132 503-554-1714 503-554-1 834 dave@integ raserviceco.com Reference Daily Temperature Range: Latitude: Elevation: Altitude Factor: Elevation Sensible Adj. Factor: Elevation Total Adj. Factor: Elevation Heating Adj. Factor: Elevation Heating Adj. Factor: Medium 44 Degrees 359 ft. 0.987 1.000 1.000 1.000 1.000 Oregon lMnter: Summer: Outdoor Drv Bulb 22 89 Outdoor Wet Bulb 0 66 lndoor Rel.Hum 0 50 lndoor Drv Bulb 72 75 Grains Difference 0 -5 7 AClhr)Per Square ft. Per TonSquare fi- of Room fuea:2,ffi4 354 TotalSensible Gain: Total Latent Gain: Total Cooling Required With Outside Air: 67,758 Btuh 9,752 Btuh 77,510 Btuh 110.467 MBH 87 o/o 13 o/o 6.46 Tons (Based On Sensible + Latent) 7.53 Tons (Based On7io/o Sensible Capacity) are ofACCA All computed results are estimates as building use and weather may vary Be sure to select a unit that meets both sensible and latent loads. Project Report Miscellaneous \Mnter: Summer:89 0 66 72 75 -5.50 50 50 Calculate: Use Schedule: Roughness Factor: Pressure Drop: Minimum Veloci$: Maximum Veloci$: Minimum Height: Maximum Height: Yes Yes 0.00030 0.1000 in.wg./100 ft. 650 ftJmin 900 ft./min 0 in. 15 in. Yes Yes 0.01000 0.1000 in.wg./100 ft. 450 ft./min 750 ft./min 0in 0in lnfiltration: Volume of Conditioned Space: Total Building lnfiltration: Total Building Ventilation 0.700x 26928 18,850 x 0.0167 314 1,275 CFM CFM 0.400x 26928 10,771 x 0.0167 180 1,275 AC/hr Cu.ft. Cu.ftJhr CFM CFM -System 1- lnfiltration & Ventilation Sensible Gain Multiplier: Infiltration & Ventilation Latent Gain Multiplier: Infiltration & Ventilation Sensible Loss Multiplier: 15.20 -3.69 54.29 = (1.10 X 0.987 X 14.00 Summer Temp. Difference) = (0.68 X 0.987 X -5.50 Grains Difference) = (1.10 X 0.987 X 50.00 Wnter Temp. Difference) AC/hr Cu.ft. Cu.fiJhr Load Preview 67,75E 9,752 10,467 543 2,228 3,000 Sptem 1 Zone 1 1-Sanctuary 2-Office 3-Glass Room 1 4-Class Room 2 S-Class Room 3 6-Class Room 4 7-Class Room 5 8-Mens Restroom 9-Womens Restroom 10-Entry ,664 67,758 48,376 2E,652 1,278 2,471 3,294 2,470 3,294 4,268 474 630 1,545 9,752 14,458 10,500 -8 840 7s4 56s 754 641 105 105 202 2,664 1,344 150 180 180 135 180 240 81 108 to 62,834 39,152 1,274 3,311 4,049 3,035 4,048 4,909 579 735 1,747 41,247 6,397 4,697 2,219 4,346 3,260 4,346 9,328 796 1,641 4,217 543 84 62 29 57 43 57 123 10 2. 55 2,228 1,319 59 114 152 114 152 197 22 29 71 1 ,319 59 114 177 133 177 235 22 29 71 3,000 1,777 79 153 204 153 204 265 29 39 96 4-12 1-6 1-8 1-8 1-8 1-8 1-10 't4 14 1-6 'eport lnc. lntegra Service Company oR 971 Tatal Loads 1C 10A 10D 12H 16D 22A Window Clear Glass Metal rame 60 21 42 1471 2664 190 Door Wood Hollow Core Door Wood Solld Core Wall R-19 + 112" Gypsum Board(R-O.S) Ceiling UnderVent. Attic - R-19 lnsulation Slab on Grade No Edge lnsulation 3,465 588 966 4,413 7,060 7,698 2,295 207 340 1,552 5,367 0 2,295 207 340 1,552 5,367 0 0 0 0 0 0 0 Su btotals for structure : People: Equipment: Lighting: Ductwork: lnfiltration: Wnter CFM: 314, Summer CFM: 1E0 1U 600 Ventilation: Winter CFM: 1 Summer CFM: 1,275 24,',190 0 15,120 0 0 s62 4,706 9,761 33,840 0 2,046 0 2,729 19,382 9,761 48,960 0 2,046 0 2,067 14,676 0 17,057 69,22A Sensible Gain Total: Temperature Swing Multiplier: 67,758 x 1.00 Total Building Load Totals:110,467 9,752 67,758 77,510 Total Building Supply CFM Square fi. of Room Area: 7 AC/hr)Square Square ft. Per Ton:2,664 1.126 354 Required V[rth Outside Air: 1 TotalSensible Gain: Total Latent Gain: TotalCooling Required With Outside Air: 110.467 67,758 Btuh 9,752 Btuh 77,510 Btuh 87 o/o 13 o/o 6.46 Tons (Based On Sensible + Latent) 7.53 Tons (Based Qn 75o/o Sensible Capacity) Calculations are ACCA Manual All computed results are estimates as building use and weather mayvary Be sure to select a unit that meets both sensible and latent loads. RHVAC - Residential & Llgtrt Commercial HVAC Loads on 1 Room Load -Zone 1- 1 Sanctuary 2 Office 3 Class Room 1 4 Class Room 2 5 Class Room 3 6 Class Room 4 7 Class Room 5 8 Mens Restroom 9 Womens Restroom 10 Entry 1,344 150 180 180 135 180 240 81 108 6,397 4,697 2,219 4,346 3,260 4,346 9,328 796 1,U1 465 342 161 316 237 316 678 58 119 4-12 14 1-8 1-8 1-8 1-8 1-10 14 1-4 10,500 -8 840 754 565 754 641 105 105 566 28,652 404 1,278 439 2,471 585 3,294 439 2,47A 585 3,294 485 4,268337 474448 630 66 4,217 1,777 79 153 204 153 204 265 29 39 1.00 1.00 1.00 1 -',17 1.17 1.17 1.20 1.00 1.00 1,319 59 114 177 133 177 235 22 29 1,777 79 153 204 153 204 265 29 39 307 14 488 1,545 202 96 1.00 71 96 System 1 total 2,664 110,46 3,000 7 67,758 9,752 3,000 2,336 3,000 System 1 Main Trunk Size Velocity: Loss per 100 ft.: 40x15 in. 814 ft./min 0.033 in.wg Recommended: 6.46 7.53 87o/o l1 75o/o l25o/o 67,758 22,586 90,344 Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: Latent Capacity: nla nla 0 Btuh 0 Btuh RHVAC - Residential & Light Commercial HVAC Loads -a6.lffiE,::S',l*,??pj"' np Elite 225 FIFTH STREET SPzuNGFIELD, OREGON 97 477 INSPECTION REQLIEST : 7 26 -37 69 OFFiCE: 726-3759 1. LOCATION OF INSTALTATION Z,/! f,1 , I r/'l i7f,eE-T JOB DESCRTPTION -tt: LEGAL DESCRIPTION t ELEC ]AL PERMIT APPLICATION A. Nerv Residentirrl-Single or Multi-Family per drvelling unit. Service Includetl: Items Cost Sum 00 ftor 2uOl irpPrOV? of issuance or if rvork ,t t"tn:1$,:9,lg1 o,nn",r," ,V) 2. CONTRACTOR INSTALLATION ONLY Christenson Electric, Inc. D.B.A. Electrical Contractor-plA[fip18.[gc !gi-c Permits are non-transferable and expfiQlin9 if work is not started lvithin Supervisor .bxprratlon Constr Contr, Orvners Name City OWNER INSTALLATION The installation is being made on properry I oivn which is not intended for sale, lease or rent. ,-o D. Ch E. 4. SUBTOTALOFABOVE 7%o State Surcharge 8%o Administrative Fee 'd Home or Service or Feeder B. Services or Feeders Installation, Alterations or. : Relocation: 200 amps or less 201 anips to 400 amps 40I amps to 600 amps 601 anrps to 1000 anps $ 63.00 I $ 75.00 'i :.'," $ 125.00 $ I63.00 .00 _ Expiration oate -a&l&1:f O5silFgrr*ts^ 1OCEO3 Srgnlture ol Supervlstng Itlectrlclan ,t ,r'Y L---ffi, Phr!!P1 T Branch Circuits Nerv Alteration or Extension Per Panel One Circuit Each Additional Circuit or or Feeder Arldress ar+ 5 t{\Ltt} s+. S$€-rtd enn"-.N*52 $ $50.00 $50,00 $25.00 $45.00 \$ Limited Limited Energy/Comm IVlinimum Electric Permit Inspection Fee is 545.00 * Surcharges Orvners Signature: TOTAL City Job Number 3. COMPLETE FEE SCTIEDTILE BELOW Acldress 1:298 BeLhel Drive ' Cirv F,ugene i OR Reconnect 1R A^--_r_v--a .,/1 -), t\.2 L ,".1 ?1 ,7c\