Loading...
HomeMy WebLinkAboutPermit Correspondence 1980-04-01PUBLIC WORKS CIltrY OF SPF,I\TGFIEIJD SPRINGFIELD. OREGON 97 47 7 April 1, 1980 346 MAIN STREET 726-3753 Mr. & l,Irs. George Schrader 1977 North ?th Street Springfield, Oregon 9T\77 RE: Royal Stoves, 1)+O North t)+ttr Street, Springfield., oregon Dear Mr. & Ivlrs. Schrader: On March 19, 1980, at your request, the Buitd.ing Division of the City of Spring- field. made an occupancy inspection of the structure located at 1l+0 North 1\th Street, Springfield, Oregon. The proposed. change of use from a retail food varehouse to a manufacture and' retait outl-et for r.rood stoves necessitated the occupancy inspection. The pro- posed new use of the structure r.rill classify it as a mixed- occupancy; H-2 being the assembLy and manufacturing portion, and B-2 being the retail sales outlet and office. 1'he following are particular items vhich shal-l be installed., repaired. or replaced- in ord.er to conform the the State Building Code: 1) A detailed set of prints and specifications of required spray booth, showing size, location, instal1-ation, and. ventilation that shall comply vith the Uni- form Mechanical Code, National Electrical Cod.e and rrith Fire Marshal-r s require- ments. 2) There sha11 be a eomplete separation of nixed. occupancies by no less than one hour fire rated valls. 3) Remove or repair all damaged and improperly installed conduits and branch cir- cuits vhich are not properly secured. l+) Remove cords vhich are being used in fieu of an approved- viring method. 5) Remove or repair aI1 damaged light fixtures. Install only approved fi-xtures' 6) Seal all unused. knockout holes in boxes and put proper covers on boxes and panels' T) Install adequate feeders and branch circuits from approved' service panels to prop- erly serve the lights and equipment. S) Install proper size of circuit conductors and prcper size overload branch circuit deyices. Note Art,icle 210, Section 2lO-23 etc., also Article )+OO of the State Electrical SpecialitY Code. t f M". and Mrs. Schrader 0ccupancy Inspection Page 2. 9) At the least, the mini-mum electrical standards sha11 be maintained. at arltimes. A11 property that is being 1eased., rented or sold is required. to be vired. by alicensed. el-eetrical- contractor. All- neeessary permits shal-l be obtained. before work starts and. arl work shal_l- beaceomplished' according to applicable cod.es and inspected. before a certificate ofCompliance vill- be issued. Pl-ease direct all inquiries to the springfield Building Division at T2G-3753. Sincerely, \){r.--h Dave Puent Building fnspector DP /IJ I