HomeMy WebLinkAboutPermit Building 2000-04-07ctTY oF sPRtmGFtEL4 OREGOL
SPRINGFIELD
Job# 00-00235-01
RESIDENTIAL PERMIT
City Of Springfield
Community Services Division
Building Safety
spr
Addition:
Page 1 of 3
Job Number: 00-00235-01
Office:726-3759
lnspection Line: 726-3769
Tax Lot #: 00806
Subdivision:
Springfield, OR 97478
Value: $80,564
TRANSS:01-0001169
DAIE:APR O? ?OOO
Al{T RECD:Z $ 509.44
IHANEE:
EASHIER:059
225 North Fifth Street
Springfield, OR97477
Location Of Proposed Site: 6539 Thurston Rd
AssessorsMap#: 17023412
Lot: Block:
Owner: David Dolby
Address: 6539 Thurston Road
Scope Of Work: Single Family Residence
Phone Number:
City/State/Zip:
Repair
Fire Damage/ Entire Structure.
2nd srrhmittal is for a second storv to he added to the oaraoe.
Contractor Type Contractor Registration # Expiration Date
General Contr Peterson & Moore Construction
I o2o birch tl*": rUiJ,,il,:,j:
:_!, _ y,, i,cr
l*lil.'ffi*fi$ r'n',n'*'
po box 22753, Eugene, OR
Phone
541-998-5320
541-344-3561
503-BB7-4467
541-463-8007
Quad Area:
# Of Units:
Constr. Type:
Water Heater:
(vN) wood rr"l#60
IHIS
Zoning Code: LDR
flfiEdroor"'
4RNE
Office Use
-
Land Use: Single Family Dwelling # Of Buildings: 1
Occupancy Group:
Heat Source:
Sq. Footage: 576
To request an inspection call s requested before 7:00
will be made the following
i\l l8ODAY PER,OD FOR
Footing
Foundation
Shear Wal! Nailing
Framing
Drywall
Final Building
Required lnspections
Buildin
-After trenches are excavated.
-After forms are erected but prior to concrete placement.
-Before covering sheathing with finish materials.
- Prior to cover.
- Prior to taping.
-When all required inspections have been approved and the building is complete.
a.m. will be made the same
working day.
Rough Electrical
Electrical Service
Final Electrica!
Underfloor Plumbing
Rough Plumbing
Final Plumbing
Rough Mechanical
FinalMechanical
Zoning: LDR
FloodPlain? ! Wetlands? [
Journal numbers
1: 2:
Comments:Max building height 30'
Planner: AlWard
Urban Growth Boundary?
Quantity Of Fill:
Supplier:
Drainage:
Floodway FEMA:
Job# 00-00235-01
Required lnspections
Electrical
- Prior to cover.
-Must be approved to obtain permanent power
-When all electricalwork is complete.
Plumbing I
-Prior to insulation or decking.
- Prior to cover.
-When all plumbing work is complete
Mechanical
- Prior to cover.
-When all mechanicalwork is complete
Page 2 of 3
Overlay District:
# of Street Trees:
3:
Additional Requirements:
tr Glenwood Area? ! Required Attachments:
Source Locn:
Material:
Flood Plain FEMA:
Land Use: Single Family Dwelling
Pave Driveway? E
Construction Types(VN) Wood Frame
Occupancy Groups:
# Of Buildings: 1
# Of Bedrooms:
Handicap Access?
Area (Sq.
Main:576 Accessory:
# Of Stories: 2 Height (feet): 21
Current Units:1 Proposed Units:
Census Code: Does not apply
Total:576
Fee Paid On Receipt# Value/Quantity Fee Amount
Plan Check
Residential Plan Check
Hourly Plan Review
Total Plan Check
03t22t2000
03t22t2000
1 007
1 004
10,564
1
$56.23
$40.00
$96.23
Building
Building Permit
Building Permit
State Surcharge For Building Permit
State Surcharge For Building Permit
Building Administrative Fee
Building Administrative Fee
Total Building
03t2212000
04t07t2000
03t22t2000
04t0712000
03t22t2000
04t07t2000
1 004
1 169
1 004
1 169
1 004
1 169
70,000
10,564
$343.00
$86.50
$24.01
$6.06
$10.29
$2.60
$472.46
Electrical
State Surcharge For Electrical Permit 03t2212000 1004 $.00
Job# 00-00235-01 Page 3 of 3
Fee Paid On Receipt# Value/Quantity Fee Amount
Electrical
State Surcharge For Electrical Permit
Electric Administrative Fee
Electric Administrative Fee
Total Electrical
04t07t2000
0312212000
04t07t2000
1 169
1 004
1 169
$.00
.00
.00
.00
$
$
$
Plumbing
Minimum Plumbing Permit Fee
Minimum Plumbing Permit Fee
Number of Fixtures
State Surcharge For Plumbing Permit
State Surcharge For Plumbing Permit
Plumbing Administrative Fee
Plumbing Administrative Fee
Total Plumbing
03t22t2000
04t07t2000
04t07t2000
0312212000
04t07t2000
03t22t2000
0410712000
1 004
1 169
1 169
1 004
1 169
1 004
1 169
1
3
$15.00
$.00
$30.00
$1.05
$2.10
$.4s
$.e0
$49.50
Mechanical
Minimum Mechanical Permit
Minimum Mechanical Permit
Mechanical Administrative Fee
Mechanical Administrative Fee
Vent Fan to One Duct
Mechanical lssuance
Mechanical lssuance
State Surcharge For Mechanical Permit
State Surcharge For Mechanical Permit
Total Mechanical
0312212000
0410712000
0312212000
04t0712000
04t0712000
03t22t2000
04t07t2000
03t22t2000
04t07t2000
1 004
1 169
1 004
1 169
1 169
1004
1 169
1 004
1 169
1
$15.00
$12.00
$.45
$.45
$3.00
$10.00
$10.00
$1.05
$1.0s
$53.00
Sanitary Sewer
SDC Administrative Fee
Total System Development
System Development
04t07t2000
0410712000
1 169
1 169
7 $337.89
$16.8e
$354.78
Grand Total
Plan Check Type
lnitial Revlew-Res
Engineering-Res
Planning-Res
Structural-Res
$1,025.97
Checked By
Lisa Hopper
Steve Templin
AlWard
Don Moore
Date Completed
0312312000
0312412000
0313112000
04t04t2000
By signature, I state and agree that I have carefully examined the completed application and do
hereby certify that all information herein is true and correct, and I further certify that any and all work
performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of
the State of Oregon. I further state that only contractors and employees who are in compliance with
ORS 701.055 will be used on I further agree to ensure that all required inspections are
the pro project address is readable from the street, that the permit card
set of plans will remain on the site at alltimes
4-
the p
Signature Date
1
ATTACHMENT A
CITY
JOURNAL OR JOB NUMBER
NAME OR COMPANY:
LOCATION:
TAX LOTNUMBER
DEVELOPMENT TYPE:
FIELD
00-00235-01
DEVELOPMENT CHARGE WORKSHEET
DAVID DOLBY
6539 THURSTON RD
t7-02-34-12-00806
NEW SECOND STORY ON GARAGE OF FIRE RESTORATION
DWELLING UNITS:BUILDING SIZE:LOT SIZE:
0.00 + $0.232 PER SQ. FT $0.00
2. SANITARY SEWER-CITY
NUMBER OF PFU'S
(SEE REVERSE SIDE)
x $48,27 PER PFU7 $337.89
3. TRANSPORTATION
NUMBER OF TRIPS x TRIP RATE x COST PER PM PEAK HOUR TRIP
0 x 1.01 x M86.73 PER TRIP
x x M86.73 PER TRIP
$0.00
$0.00
TOTAL TRANSPORTATION SDC $0.00
4. SANITARY SEWER - MWMC
A. REIMBURSEMENT COST:
NUMBER OF FEU's 0
B.IMPROVEMENT COST:
NUMBER OF FEU's 0
x $242.16 PER FEU
x 522.05 PER FEU
x 0.05
$0.00
$0.00
MWMC CREDIT IF APPLICABLE (SEE REVERSE)
MWMC ADMINISTRATIVE FEE
$0.00
$0.00
TOTAL MWMC SDC $0.00
SUBTOTAL (ADD rTEMS 1,2,3, & 4)
5. ADMNISTRATIVE FEES:
BASE CHARGE (SUBTOTAL ABOVE)$ 16.89
89
s;E*7*r-$3s4.78
SDCreOORDINATOR DA-Ttr
TOTAL SDC CHARGES
1. STORMDRAINAGE
IMPERVIOUS SQ. FT.
PLUMBING FIXTURE LINIT (PFU) CALCULATION TABLE
NUMBER OF NEW FIXTURES X TJNIT EQUTVALENT = PLUMBING FXTURE UNITS
fNOrr: rOn ngUOOel,S
PLUMBING
FIXTURES UNIT FIXTURE
FIXTURE TYPE NEW OLD ALENT UNITS
BATHTUB
DRINKING FOLTNTAIN
FLOOR DRAIN
INTERCEPTORS FOR GREASE/OIL/SOLIDS/ETC.
INTERCEPTORS FOR SAND/AUTO WAS}VETC.
LAUNDRY TUB/CLOTHESWASHER/MOP SINK
CLOTHESWASHER - 3 OR MORE
MOBILE HOME PARK TRAP (1 PER TRAILER)
RECEPTOR FOR REFRIGERATORJWATER STATION/ETC.
RECEPTOR FOR COMMERCTAL SINK/ DISHWASHER/ETC.
SHOV/ER, SINGLE STALL
SHOWER, GANG (NUMBER OF HEADS)
SINK: BAR, COMMERCIAL, RESIDENTIAL KITCHEN
URINAL, STALLAVALL
WASH BASIN/LAVATORY, SINGLE OR DOUBLE
TOILET, PUBLIC INSTALLATION
TOILET, PRIVATE INSTALLATION
MISCELLANEOUS:
21
0
2
I
2
J
6
2
6
6
I
J
2
I
2
2
I
6
4
0
0
0
0
0
0
0
0
0
0
0
0
I
0
4
0
0
0
TOTAL PLLMBING FIXTURE UNITS:
CREDIT CALCULATION TABLE: BASED ON ASSESSED VALUE
IF IMPROVEMENTS OCCURRED AFTERANNEXATION DATE IN TABLE, CALCULATE CREDITS SEPARATEL
YEAR
ANNEXED
RATE PER $I,OOO
ASSESSED VALUE
YEAR
ANNEXED
RATE PER $I,OOO
ASSESSED VALUE
$4.47
$ 4.38
s 4.32
$4.20
$ 4.03
$ 3.88
$ 3.68
$ 3.38
$ 3.03
$2.62
1989
1990
t99t
1992
r993
1994
1995
1996
1997
1998
$2.r8
$ l.7s
$ 1.35
$ l.l7
$ 1.03
$ 0.86
$ 0.71
$ 0.57
$ 0.39
$ 0.18
1979 orbefore
1980
l98l
1982
1983
1984
1985
1986
1987
1988
CREDIT FOR PARCEL OR LAND ONLY IF APPLICABLE
IMPROVEMENT (IF AFTER ANNEXATION DATE)
x
x
$0.00
$0.00
$0.00CREDIT TOTAL
7
I
I