Loading...
HomeMy WebLinkAboutPermit Correspondence 1995-08-25Address File OREGONCITY OF SPRlNq.rrjlELD DEV ELO PMENT S E RV ICES DEPA RT M EN 1 August 25,1995 McKay Investments 2300 Oakmont Way Suite 214 Eugene, OR 97401 Subject : Occupancy Inspection at 1075 Shelley Street, Springfield, Oregon. Proposed Use: Cabinet Manufacturing Dear McKay Investnents, At your request, the Community Services Division/Building Safety conducted an inspection of the building at the above address. The purpose of the inspection was to determine the suitability of the building for the proposed use as indicated. Based on the proposed occupancy, the existing conditions which are mentioned below do not meet the minimum Building Safety Code requirements. Corrective measures must be taken prior to occupancy to install, repair, replace or modiff the following items in order for the building to conform to applicable safety codes: l. Exits shall be provided as specified in Chapter 33 of the State of Oregon Structtral Specialty Code. 2. Access to and egress from buildings required to be accessible shall be provided as specified in chapter 3l of the State of oregon Structural Specialty code. 3. When required by other provisions of this code, automatic fire-extinguishing systems and standard pipes shall be designed and installed as specified in Chapter 38 oith" St t" of Oregon Structural Specialty Code. 4. Equipment or machinery which generates or emits combustible or explosive dust or fibers shall be provided with an adequate dust-collecting and exhaust.yrt"- installed in conformance with the Mechanical Code. 5. Office area related to Group H, Division 2 Occupancies shall be required to be of two- hour fire resistive construction. 6. A two-hour fire-resistive occupancy separation shall not of less than two-hour fire- resistive construction. This is required on the South wall of the building. Qfr,225 FIFTH STREET SPRINGFIELD. OR 97477 (503) 726-s7s3 FAX (s1s) 726 3689 7 . Every portion of a Group H Occupancy building having a floor area of 200 square feet or more shall be served by at least two exits. Within Group #1,2 and 3 Occupancies, all portions of any room shall be within 75 feet of an exit door. Exit doors from a room classified as Group H, Division 1,2, arrd 3 Occupancies shall not be provided with a latch or lock unless it is panic hardware. 8. Plans to be submiued showing proposed use of building. 9.Any required permits shall be obtained prior to beginning any repair or alteration to the building. 10. Administrative and clerical offrces and similar rooms related to Group H, Division 2 will require a one-hour fire-resistive occupancy separation, which will be of not less than one hour fire resistive construction. All openings in such separation shall be protected by a fire assembly having a one-hour fre-protection rating. If you need further information or have any questions regarding the above requirements, please contact myself between the hours of g:00-9:00 a.m., t:gb-z:oo p.-., o. 4,00-4:30 p.m. at 726-3759. Sincerely, Bob Bamhart Building Inspector cc : Dave Puent/community Services Manager/Building offi cial LAB-*I^d F LL- i1-11!u :I:,1.- FFit:rit aIFIEFF]:tt.tr trEE,lilt,tE It.lr_Tr-r - - J =i r:_,rl Ir ir_r _il_ri_r _i t:l OMLID & SWII{I{EY FIRE SPHINKLER SYSTEMS 1265 NORTH 35Ih, $PRINGFIELD, OHEGON 07478(so3) 741-177s (800) strl-177s FAX (5O3) ?41.0347 State License Number$:washington 600584760 Oregon 62730 Catifornia 564000 DESICiI }FABRICATION INSTALLATION August 30, 1995 MAINTENANCE t Tul nL F. tjt: a i tiuP'rl,{ Forefront Designs, Inc. Atrn: Doug 417 High Street Eugene, OR 97401 sr.rtrjer:r : 1a75 'Shelly street Building in springfield, oregon Dear Doug; The entirc bTld$lllresprinklered, originally de-signed and installed to an ordinaryllaarrrd. Group 2 1994 NrPe l3level which is lequiierl foiwood machining/nood proclucr{sscniblY ttse utrder NFPA tS- .ffr.e system consisis of 80 heads with a clensitl, of ,iO G,p.M./sqft', l50O sq. ft. design area of 9i9..S., a sysrem demand of 361 ,9 C,p.M. discharge r+,ith a i'r.' ,,r.lual pressure at the bese of the risir of 82,7 pSL if 'sou have any questiorx, please ccli meat T+l-LTjS, Thank vou. /1. Mike fucher /,b tvlA/dio \ru \D\oEot\\ \-l--}rrc;\e-\ \}{- ,fnt tG;d t \c\Jn_\\<R\, $-\ \. OCCUPAI.ICY INSPECTION APPLICATION CTTY OF SPRINGFIELD BUILDING DIYISION DATE:ffi..-r pO L*S JOB NUMBER:q 5lv.bl ADDRESS oF rNSpECrroJ, - inr 6 StJa:.-p-r lEI. oOVNER: OVNER'S ADDRESS: APPLICANT: APPLICANT'S ADDRESS: FOR ACCESS TO PROPERTY - TELEPHONE NUMBER: Tzrr PROPOSED USE: A $gS.OO INSPECTION FEE IS REQUIRED AT THE TIME OF APPLICATION THIS APPLICATION FORI,I MUST BE SIGNED BY THE O\{NER OF THE PROPERTY TO BE IN FOR OFFICE USE ONLY 1-11"4 IDATE PAID: DATE OF INSPECTION: . DATE OF CERTIFICATE OF COMPLIANCE: COMMENTS: RECEIPT NUMBER: DATE OF REPORT: I t t?r4