Loading...
HomeMy WebLinkAboutPermit Mechanical 1980-12-01B CONSTR.Y CTION / PTECEM ENT IF? PERMIT FOR OFFTCE USE ONLY Applica Permit # Irro copies of P flrro Copies of Plot Plans ! l.lechanical Checklist fetumning checklist Irtan Check fnfo Sheet COMPLETE IS BLOC PLEASE USE BLACK INK AND PRINT. r3lRANGEova7.73SECTIONTOI.INSHIP \-7 I STREET tI PROPA9ND'JSi -F PROPER?Y finesidential Drndustrial I commercial f]rulric OFOF+ E roposed xisting NUMBERTELEPHONE6?{Outr* r' Lr/[ta-I rqE &nowNER-g NAME AND ADDRESS S OSR NAT.IE TC) + NAm (PIeas6 Print) APPLICATION THOROUGHLY andtr ue andcorrectolrfornati1Shereonaicrtthadohe rc by fyICATICNAPPLPERMITFORIULLYTiIEXA-!4INED COMPLETEDCARE oft,e Lai r)LheaId ofLails the pcrOre q ln ngrhOrdiIancetheoLanbeINdoneordanceCountyaccworkaI1shartcethaLandperformedfyanycertfurtherofButhevaDiQNtywstructuralthoutthetding,ANCYOCCUP 1l nadebe permissl-onofhereinthatandNOanytothdeworkcribed notedifbatheforredoRs055thatxenptionandforceASeffectbyexenplBuilderBoard1nastequifu1teattrationthethrhqi.THCIIECT€DREADANDHAr.rE1011wi-usedbe this1nthoRs j ectprow1andarewhocompliancethatandsubcontractorsemployeeonlyhereon [-l or.". tr PLANNING Minimum Setbacks: Coments: ZONING:Zone RA Partrtion #Parcef #;-rr."r slr. tr:f A \- C cL, front_L , s idc--.-in terio:: --.--; re ar fl ff,OOOpf,afU3 rn l,ood hazard area? fl *" I v.s, see atrached stieet n RURAL ADDRESSING:GRID COOR-DINATE N E Date: Date ! Date: @ DI tr SANITATION: s. r. # Installation Specifications: B. P. #rnstallation Record rssued,? fl v"" fl ll" Maximun Depth of TrenchesGal lon Tank Lineal Feet of Dralnfi-eld Comments Date: PLANS EXAMINATION: Type "r.tn fr?Us Cotrments CONSTRUCTION AUTHOR]ZED BY THIS PERMIT Descriptipn Sq. Ft. Fixed Fee,/unit cost Floodplain Fee Subsurface Fees Building Fee Sewer/Storm Drain/water Plumbing Fixtures Mechanical Plans Check Fee State Surcharge TOTAL FEE FEES PAfD BY:I crrecx ffcrsr, $ ) s $ > $ $ $ TOTAL VALUATION $ By: Date:p,t -ND PERMIT AFPROI,ED BY BUILDING SIGNEE r oRs 456.805 (l-) )DATE LANE COUNTY DEPARTMENT OF ENVIRONMENTAL MANAGEMENT / 125 EAST EIGHTH AVENUE, EUGENE, OREGON 9140L C74-Ig4 SEE REVERSE I I I I 701 .055 on I tr < ''.;**.. _ sETBAcKs AND ,THER c,NDITI'NS 0F AppRovAL-rvrt]r-:lrgJlI .B!!RVED. vr'LATroN cAN RESULT rN REvocArr,N 0F rHrs 'ERMrr,cITATIoN UNDER PRoVISIoNS 0F LANE CoUNTY'S INFRACTION oRDTNANCE, AND/OR OTHER REMEDIES ALLOWED By LAI,I. WHEN READY FoR INSPECTIoN CALL 687-4065. A MINIMUM 0F AT LEAST 24 HoUR ADVANCE NoTICE FOR INSPECTION REQUEST MUST BEGIVEN. Have the following information ready:. permit numbere job address, type of inspection, when it *irr be reaay,your name and phone number, and any special directions to site. BUILDING DIVISION: REQUIRED IIISPECTIONS 1) FoUNDAJI0N INSPECTI0N: To be made after trenches are excavated and forms erected and when all materials for the foundationare delivered on the job. Where concrete from a central mixing plant (commonly termed "transit mixedii) is to-Ue r;;e;- - materials need not be on the Job. 2) Q0NqRFTE SLAP 0R UNDER-F!0OR IIISPEPTION: To be made after all in-slab or under-floor building service equ.ipment,conduit, piping_accessories and olIer ancillary-equipment items are in place but before any c6ncrete is iouiedor floor sheathing installed, includ.ing the subfloor. 3) FB$MITG & IU;ULAJIoN INSPECTI0NS: To be made after the roof, at'l framing, fire btocking and bracing are in p'lace anda1l-pipes, fireplaces and -fimneys and.vents are complete and all rough 6iectricai and [lumbing are"approved. nttwall insulation and vapor barrier are in place. 4) LATH AND/oR GYPSUM BoARD INSPECTIoN: To be made after a1l lathing and gypsum board, interior and exterior, is in placeorbeforegyps,,boardjoinisana"?isienei-aretapedandfinished. 5) FINAL INSPECTIoN: To be made after the building is complete and before occupancy. APPRoVAL REQUIRED' No work sha:ll be done on any part of the building or structure beyond the point indicated in eachsuccessive inspeetion without first obtaining the approval of the.building offii.ial. -Such.ppi^or.t sttiti oe given onlyafter an inspection shall have been made of each suctessive step'in the c6nstruition as inaititea ov eactr or irre inspeitionsrequ i red. NOTE: All building permits require inspections for the work authorized, such as but not limited to:A. BLOCK WALL: To be made after reinforcing is_in p1ace, but before any grout is poured. This inspection isrequired for,each.bond beam pour. There wi'll be no approval until tie'piumbing'ana etectrical ihspectionshave been made and approved. B. t"J00D ST0VE: To be made after completion of masonry (if applicable) and when installation is eomotete.Instal'lation shall be in accordance with an approved nationally recognized testrng agency arrd the manu-facturer's instal lation instructions. C. I40BILE H0ME: An inspection is required after the mobile home is connected to an approved sewer or septic system for: setback requirements, blocking, footing connection, tiedowns, skirting, and p'lumb.ing connecti ons. (1) Footings and piers to comply with State foundatjon requirements for mobile homes or as recommendedby the manufacturer.(2) Mobile home minimum finish floor elevation shall be certified when required by a floodplain management letter.(3) l4obile home tiedowns, when requ'ired, and skirting shall be installed and ready for inspectionwithin at least 30 days after occupancy. Tiedowns and skirting shalI be instil1ed per'enciosure. D. SWIMMING P00L: Below grade when steel is in place and before concrete is poured. Above grade when poolis 'i nstalIed. APPROVEO PLANS MUST BE ON THE JOB SITE AT ALL TIMES DURING WORKING HOURS. THIS PERMIT l^lILL EXPIRE IF l,lORK DOES NOT BEGIN WITHIN ]8O DAYS, OR IF I^IORK IS SUSPENDED OR ABAI{DONED FOR MORE THAN ]8O DAYS. SUSPENSION OR REVOCATION MAY OCCUR IF THIS PERMIT hlAS ISSUED ON THE BASIS OF INCOMPLETE OR ERRONEOUS INFORMATION. ANYONE PROCEEDING PAST THE POINT OF REqUIRED INSPECTIONS I,JILL DO SO AT HIS O[,IN RISK SUBSURFACE AND ALTERNATIVE SEWAGE DISPOSAL SYSTEMS Permits shall be effective for one year from the date of issuance.. Upon completing the construction for which a permit has been issued the permit holder shall notify the Departme4t by submittipg the in-sta.llation record form. The Depar*ngnt,shall inspect the construciion todetermine i'f i.t-'compl ies wi"thlthe.fi.rl,es contained i.n ,this division. If the construct'ion does comply vrith such rules, the Department shall issue a certificate bf satisfactory corppletion..to the permit holilei. If theconstruction does not comply with such.ruJes, the Depfttnent shalli notify.the peimit holder and shalI requiresatisfactory.completion before issuing the certificate. Failure tormeet ihe rbquirements for satisfactorycompletior within a reasonable time constitutes a violation of ORS 454.605 to 454.745 and this rule. Setbacks - Subsurface Sewaqe Disposal (r ) (2) Septic Tank Dra'i nf i el d -T0--t0''10' 5' 50' 'I 0' t0' 'I 00' From: Interior property lines Edge of road right-of-way Bui lding foundation l,lells, other water sources Lane Countg Date: 08-Jan-L990 ROBERT SYKES OR OCCI'PANT l-l_98 SBQUOIA AVENUE SPRTNGFTELD, OR 97 477-3552 SU&TECT: WOOD BURNING APPLIANCE PERMIT APPLICATION NO. BP 3231-80 your permit application for a wood burning appliance has expired. Each permit issued by the building official, under the provisions of the-auilding Code (Oregon State Mechanical Speciatty Code) shall expire by Iimitation and become null and void if the work authorized by such permit is not commenced within 180 days from the date of such permit, or if the work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 1-80 days. No permit shall be extended more than once. [Sec. 303 (d) OSUC] Section 305(d) OSUC states: rrlt shall be the duty of the person doing the work authorized by a permit to notify the building official that such work is ready for inspection.rl In addition, Section 303(c) OSMC, says: rrThe issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of other ordinance of the jurisdiction. " Recently, dD agreement was made between Lane County and the cities of Eugene and Springfield resulting in the creation of an 'UrbanTrinsition Area, where the respective city codes apply as well as the State of Oregon Building Code. Since the cities and Lane County utilize the same Staie of Oregon Mechanical Specialty Code, the section references listed above apply in a1t jurisdictions. If your address is witnin a city Urban Transition Area or within the city limits, you must make application for any anticipated permit actlvity for a wood burning appliance (or other activity) with your city'building department'. Thank you for your cooperation. If you have guestions or feel you need clarification, please feel free to call me at 687-4466. Roger McGuckin Building Official, Lane CountY LANDMANAGEMENTDTV/PUBL|CWORKSDEPT / l25EASTBTHAVENUE / EUGENE,OREGON97401 l(503) 687-4061 IFAX# (503)687-3947 ,/) (INSPL.TION TAX LOTTOWNSH I P RANGE SUBDIVISI PA TIrr' OWNER'S NAME AND SITE ADDRESS CONTRACTOR"S NAME AND ADDRESS # BEDROOMS SPECIFICATION: SECT \, Gal I on Tank . Drainfield Max.tren ch depth LOT/PARCEL BLOCK PERMIT NUMBER 3 TELEP ONE NUMBER TELEPHONE NUMBER-o/ (> Serial _ Equal SDS INSTALLATION MINIMUM SETBACK REQUIREI4ENTS: WATER SUPPLY C front L,de I nteri New _ Repair _ Alteration _ # PLUMBING FIXTURES # EMPLOYEES DIRECTIONS TO SITEt',/-tttzd 0L-/;^ I CORD FrE{. D CARU((@ zPL INSPECTION TYPE APV/DISAPV DATE INSPECTOR REMARKS /z-/?8o /4 N( fuPil**? cr"qf eJ, FJAN r?ato a.*-- #.fi{ q'/\) Lr--t