Loading...
HomeMy WebLinkAboutPermit Mechanical 2019-12-06OREGON Web Address: www.springfield-or. gov Building Permit Commercia! Mechanical Permit Number: 81 1-19-OO27 27 -MECH IVR Number: 811044505989 City of Springfield Development and Public works 225 Fifth Street Springfield, OR 97477 541-726-3753 Email Add ress: permitcenter@springfield-or.9ov SPRINGFIELD {6 Permit Issued: December 06,2OL9 Category of Construction: Commercial Submitted Job Value: $8,000.00 Description of Work: 2-head ductless HP and ERVI-OSA Type of Work: Alteration Worksite Address 4110 OLYMPIC ST Springfield, OR 97478 Parcel 1702300000402 Owner: Address: Owner: Address: GAIL DANNEN SURVIVORS TRUST 1950 LAKEVIEW DR EUGENE, OR 97408 MARSHALL W DANNEN II FAMILY TRUST 1950 LAKEVIEW DR EUGENE, OR 97408 Business Name MARSHALLS INC - Primary License ccB License Number 25790 Phone 54L-747-7445 Inspection 2999 Final Mechanical 2999 Final Mechanical 2300 Rough Mechanical fnspection Group Mech Com Mech Com Mech Com Inspection Status Pending ' Pending Pending Various inspections are minimally required on each project and often dependent on the scope of work. Contact the issuing jurisdiction indicated on the permit to determine required inspections for this project. Schedule or track inspections at www.buildingpermits.oregon.gov Call or text the word "schedule" to 1-888-299-2821 use IVR number: 811044505989 Schedule using the Oregon ePermitting Inspection App, search "epermitting" in the app store permits expire if work is not started within 180 Days of issuance or if work is suspended for 180 Oays or longer depending on the issuing agency's policy, All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. Granting of a permit does not presume to give authority to violate or cancel the provisions of amy other state or local law regulating construction or the performance of construction. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0O1O through OAR 952-OO1-OO9O. You may obtain copies of the rules by calling the Center at (5O3) 232-L947. All persons or entities performing work under this permit are required to be licensed unless exempted by ORS 7O1.O1O (structurauilechanical), oRs 479.540 (Electrical), and oRs 693.o10-o20 (Plumbing). printed on: 1216/19 page 1 of 2 C:\myReports/reports//production/01 STANDARD h^l^a TYPE OF WORK ,OB SITE INFORITIATION LICENSED PROFESSIONAL IN FORMATION PENDING INSPECTIONS SCH EDULING INSPECTIONS Permit Number: 81 1-19-0027 27 -MECH Page 2 of 2 Fee Description Technology Fee Commercial mechanical permit (based on mechanical job value) State of Oregon Surcharge - Mech (t2o/o of applicable fees) Printed on: 1216/19 Page 2 of 2 Quantity Fee Amount $s,03 $180.60 $2L.67 $21 1.30Total Fees: C :\myReports/reports//production/01 STANDARD PERMIT FEES SPRINGIIELD nfi OREGON www. sprin gf ield-or. gov Worksite address: 41 10 OLYMPIC ST, Springfield, OR 97478 P ar cr-l'. I 7 02300000402 Transaction Receipt 811-19402727-MECH IVR Number: 81 I 044505989 Receipt Number: 473214 Receipt Date: 1216/19 City of Springfield Development and Public Works 225 Fifth Street Springfield, OR 97477 541-726-3753 permitcenter@springfi eld -or. gov Fees Paid Transaction Units date 't2t6t19 1.00 Ea Description Commercial mechanical permit (based on mechanical job value) State of Oregon Surcharge - Mech (12o/o ol applicable fees) Account code 224-00000- 425604- 1 03 1 821 -00000-21 5004-0000 204-00000 -425605-0000 Fee amount $180.60 $21.67 $9.03 Paid amount $180.60 $21.67 $9.03 12t6t19 1.00 Ea 12t6t19 1.00 Automatic Technology Fee Payment Melhod Credit card authorization: 02800q Payer: MARSHALLS INC Payment Amounl:$211.30 Cashier: Chris Carpenter Receipt Total:$2,l r.30 Printed: 1216/19 3:35 pm Page 1 of 'l Fl N_TransactionReceipt_pr \r ^r- Crry oF SprNGFIELn, ORncoll Mechanical Permit A lication 225 Fifth Strect I Springfield, OR 97477 . PH(541)726-3753 r FAX(541)726-3689 This permit is issued under OAR 918-440-0050. Permits expire if work is not started within 180 days of issuance or if work is suspended for 180 days. CATEGORY OF CONSTRUCTION E Residential ! Govemment ffi Commercial JOB SITE INFORMATION AND LOCATION Job site address itut"i6yt zrP:QlJlf, Reference I DESGRIPTION OF WORK br,0 b(L U- *f Xrr+r -6-Lj PROPERTY OWNER Name:4zf " CL+fuyO t2A{F\NfU\) Address: jo f- lA k14J Jf UndVIL- City: (|rtfl-f?rrNf{-State: pl,Q-z\dlyt6t I Phone:ftl/ 6.lZ - 11Ci7-Fax E-mail This installation is being made on property owned by me or a member of my immediate family, and is exempt from licensing requirements under ORS 701.010. CONTRACTOR INSTALLATION Business name:t NU Address oL' City: <--??t-l.l State: (!/l ztv:Q'll'lf, Phone:Fax: E-mail: CCB license no. Print name Signature 5PR!HGF'ELO *, DEPARTMENT USE ONLY Permitno.:\11-2J7'l Date:/'L//" / t9 FEE SCHEDULE Residential Qty.Cost ea. Totel cost il02-00 sFirst Aooliance Furnace/burner includine ducts and vents 823.00 $Up to 100k BTU,4rr t26.00 $Over l00k BTU/hr, If p*f ers/sf oves/venf s $23.00 $Unit heater Wood/pellet/gas stove/flue $54.00 $ $r9.00 $Evaporated cooler $r3.00 $Vent fan with one duct/appliance Hood with exhaust and duct $19.00 $ One to four outlets $9.00 $ $s.00 $Additional outlets (each) $1s.00 $Up to 10,000 CFM Over 10.000 CFM $26.00 $ Compressor/absorntion svstem/heat nump Up to 3 hp/100k BTU t23.00 s Up to l5 hp/500k BTU $41.00 $ Up to 30 hp/l,000 BTU $61.00 $ Up to 50 hp/1,750 BTU t78.00 $ sOver 50 hp/I,750 BTU 1132.00 Incinerators Domestic incinerator $26.00 $ Gommercial Enter total valuation ofmechanical svstem and installation "o"ss*, 6b) Enter fee based on valuatiori of mechanical system, etc.$ Miscellaneous fees Cost ea. Total cost 1102.00 $Reinspection Specially requested inspections (per t102.00 $ t19.00 $Regulated cquipment (unclassed) Each additional inspection: (l)t102.00 $ $d7)g(A) Enter subtotai ofabove fees (or enter set minimum fee of $ 102.00) (B) Investigative fee $ (C) Enter l2%o surcharge (.12 x [A+B])$ (D) Seismic fee, lo/o (.01 x [Al)$ (E) Technology Fee (5% oflAl)$ TOTAL fees and surcharges (A through E)s) lt 5,) Lasr edited 7/l/2019 BJoncs Taxlot.: sAir-handlins units. includins duc DEPARTMENT USE GOMcheck Software Version 4.0.3.1 Mechanical Gompliance Certificate Section 1: Project lnformation Energy Code: 2009 IECC Project Title: Marshall's Office Expansion Project Type: Alteration Construction Site: 4110 Olympic Street Springfield, OR 97478 Permit No. 1 9-001502.STR Section 2: General lnformation Building Location (for weather data): Climate Zone: Owner/Agent: M. Chad Dannen Marshall's inc. 4110 Olympic Street Springfield, OR 97478 541-747-7445 chad@marshallsinc.com Springfield, Oregon 4c Designer/Contractor: M. Chad Dannen Marshall's lnc. 4110 Olympic Street Springfield, OR 97478 541-747-7445 chad@marshallsinc.com Section 3: Mechanical Systems List Quantity System Type & Descriotion 1 HVAC System 1 (Single Zone) : Split System Heat Pump Heating Mode: Capacity = 36 kBtu/h, Proposed Efficiency = 10.50 HSPF, Required Efficiency = 7.70 HSPF Cooling Mode: Capacity = 36 kBtu/h, Proposed Efficiency = 21.50 SEER, Required Efficiency = 13.00 SEER Fan System: None Section 4: Requirements Checklist Requirements Specific To: HVAC System I : fr 1. Equipment minimum efficiency: Heat Pump: 7.70 HSPF 13.00 SEER Generic Requirements: Must be met by all systems to which the requirement is applicable: gl_ 1 . Plant equipment and system capacity no greater than needed to meet loads " Exception(s): tr Standby equipment automatically off when primary system is operating tr Multiple units controlled to sequence operation as a function of load 6, 2. Minimum one temperature control device per system q 3. Minimum one humidity control device per installed humidification/dehumidification system p 4. Load calculalions per ASHRAE/ACCA Standard 183. g 5. Automatic Controls: Setback to 55'F (heat) and 85'F (cool); 7-day clock, 2-hour occupant override, 10-hour backup' Exception(s): tr Continuously operating zones p 6. Outside-air source for ventilation; system capable of reducing OSA to required minimum g 7. R-5 supply and return air duct insulation in unconditioned spacesr R-8 supply and return air duct insulation outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly Exception(s): Ei Ducts located within equipment tr Ducts with interior and exterior temperature difference not exceeding 15"F. Project Title: Marshall's Office Expansion Data filename: Untitled.cck Report date: 12106119 Page 1 of 3 M L Mechanical fasteners and sealants used to connect ducts and air distribution equipment{}I.fi S. Ouas sealed - longitudinal seams on rigid ducts; transverse seams on all ducts; UL 18'lA or 181B tapes and mastics g 10. Hot water pipe insulation: 1 .5 in. for pipes <=1 .5 in. and 2 in. for pipes >1 .5 in. Chilled water/refrigeranUbrine pipe insulation: 1.5 in. for pipes <=1.5 in. and 1.5 in. for pipes >1.5 in. Steam pipe insulation: 1.5 in. for pipes <=1 .5 in. and 3 in. for pipes >1 .5 in. Exception(s): tr Piping within HVAC equipment. tr Fluid temperatures between 55 and 105"F. tr Fluid not heated or cooled with renewable energy. tr Piping within room fan-coil (with AHR|440 rating) and unit ventilators (with AHR|840 rating). tr Runouts <4 ft in length. q t l.Operation and maintenance manual provided to building owner g l2.Balancing devices provided in accordance with IMC 603.17 g 1 3. Demand control ventilation (DCg present for high design occupancy areas (>40 person/1 000 fl2 in spaces >500 ft2) and served by systems with any one of 1) an air-side economizer, 2) automatic modulating control of the outdoor air damper, or 3) a design outdoor airflow greater than 3000 cfm. Exception(s): B Systems with heat recovery. tr Multiple-zone systems without DDC of individual zones communicating with a central control panel. tr Systems with a design outdoor airflow less than 1200 cfm. tr Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. l!,14.Motorized, automatic shutoff dampers required on exhaust and outdoor air supply openings< Exception(s): tr Gravity dampers acceptable in buildings <3 stories g lS.Automatic controls for freeze protection systems presenl g 16. Exhaust air heat recovery included for systems 5,000 cfm or greater with more than 70olo outside air fraction or specifically exempted Exception(s): tr Hazardous exhaust systems, commercial kitchen and clothes dryer exhaust systems that the lntemational Mechanical Code prohibits the use of energy recovery systems. tr Systems serving spaces that are heated and not cooled to less than 60'F. tr Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. tr Heating systems in climates with less than 3600 HDD. D Cooling systems in climates with a 1 percent cooling design wet-bulb temperature less than 64'F. tr Systems requiring dehumidification that employ energy recovery in series with the cooling coil. tr Laboratory fume hood exhaust systems that have either a variable air volume system capable of reducing exhaust and makeup air volume to 50 percent or less of design values or, a separate make up air supply meeting the following makeup air requirements: a) at least 75 percent of exhaust flow rate, b) heated to no more than 2"F below room setpoint temperature, c) cooled to no lower than 3"F above room setpoint temperature, d) no humidification added, e) no simultaneous heating and cooling. Section 5: Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical alteration pro.iect has been designed to meet the 2009 IECC, Chapter 8, requirements in COMcheck Version 4.0.3.1 and to comply with the mandatory requirements in the Requirements Checklist. VL OA$.INt4r\) C,(4-b /z . 07, k)/r Name - Title Signature Date Section 6: Post Construction Gompliance Statement tr HVAC record drawings of the actual installation, system capacities, calibration information, and performance data for each equipment provided to the owner. tr HVAC O&M documents for all mechanical equipment and system provided to the owner by the mechanical contractor. tr Written HVAC balancing and operations report provided to the owner. The above post construction requirements have been completed. Project Title: Marshall's Office Expansion Data filename: Untitled.cck Report date: 12106119 Page 2 of 3 /4r4- Outdoor Unit Multi-zone Heat Pump Ductless System 38MGRQ36D-.3Outdoor Model: Submittal Data Job Data Buyer: Unit Number: Performance Data Certified By: Table Copyright 2019 CAC/tsDP . Atlar{a, G430339 Buyer P.O. #: Location: Carrier #: Model Number: Date: MULTIZONE STANDARD FEATURES Features Outdoor: . Connect up to 4, multiple style indoor units High Wall Cassette Ducted Console . 100o/o Heating Capacity at 5' F G15'C) . Variable Speed (lnverter) Compressor . Basepan Heater factory installed . Quiet operation . Aluminum Golden Hydrophilic pre-coated fins Cooling operating range -13"-122' F (-25'-50' C) Heating operating range -22"-86' F G30'-30'C) LIMITED WARRANTT . 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See wananty for full details. see Product Data PHASED OUT INDOOR UNITS Catalog No: 38MGR-36-04S8 r:1 For matched Edition Dat6: ltl2019 tO INDOOR UNIT 4OMPHAOOgXA3 619PHAO09XA3 DHMPHAQO9XA3 DHMPHAQl2XA34OMPHAQ12XA361gPHAO12XA3 61gPEQOOgBBMA DHMSHAQO9XA340MAQB09B-3 4OMAQB12B-3 619PEQO,,I28BMA DHMSHAQl2XA3 61gPEQO18BBMA DHMSHAQlSXA34OMAQB18B_3 4OMAQB24B-3 619PEQO24BBMA DHMSHAQ24XA3 40MHHQ09--3 4OMHHQ12-A 40MHHO18---3 High Wall 40MHHQ24--3 40MBQB09C-3 61gREQOOgCBMA 40MBCQ09--3 4oMBQB12C-3 61SREQO12CBMA 4oMBCO12--3 61gREQO18CBMA 40MBCQ18--34oMBQB18C-3 40MBCO24---3 Cassette 4OMBQB09D-3 40MBDQ09--3 4OMBQB12D-3 61gREQOl2DBMA 40MBDQ12--3 4OMBQB18D-3 61gREQO18DB[iA 4oMBDQ18--3 61gREOO24DBMA 40MBDQ24--3 Ducted 40MBOB24D-3 40MBQBOgF-.3 619REQ009FB[,|A 4OMBFQOS-€ 4OMBQB,I2F-3 61gREQO12FBMA 4oMBFO12---3 40MBFQ18--3 Console 40MBFO24--3 SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces: 38MGR-36-O3SB I S cifications Rated Gombinations Copyright 2019 CAC/BDP o Adanta, GA30339 Edition Date: 1'll2019 36Size Outdoor Model 38MGRQ36D-3 4 s),€tem YESEnergy Star 3.0Tons Btu/h 36,000Cooling Rated Capacity Btu/h 8,560-45,020Cooling Cap. Range Min - Max 21.5SEER 13.5EER Btu/h 36,000Heatino Rated capacity (47'F) 36.660Heatino Maximum Capactty (5'F)Btu/h Heatino Cap. Range Min - Max Btu/h 7,21 0-50,350 10.5HSPF coP (47'F)W^^/3.8 W/W 1.78 Performance Non-Ducted coP (5'F) NOEnergy Star 3.0 Btr/h 36.000Coolinq Raied Capacity 8.s10-42.635Coolino CaD. Ranoe Min - Max Btu/h 20.25SEER 12.4EER 36.400Heatino Rated Caoacitv (47"F)Btu/h Capadty (5'F)Btu/h 36,065 Btu/h 7.045-47.800Heatinq Cap. Ranqe Min - Max HSPF 21.5 W/w 3.7coP (47'F) coP (5'F)Wrw 1.76 Perfomancs Combination Ducted and Non-Ducted NOEnergy Star 3.0 Btu/h 36,000Coolins Rated Capaciv 8.460-40.250Coolino CaD. Ranoe Min - Max Btu/h iEER t9 11.3EER 37.000Heatinq Rated Caoacitv (47"F)Btu/h Heatino Maximum Caoacitv (5'F)Btu/h 35,470 Btu/h 6.880-45.250Heatino cap. Ranoe Min - Max HSPF 11 W/w 3.6coP (47'F) 1.75 Performance DuctBd )oP (5'F)W/W Operating Range Cooling Outdoor DB Min - Max 'Frc)-13-122(-25-50) Heating Outdoor DB Min - Max 'Ffc)-22-86 (-30-30) Piping Total PiDinq Lenoth ft (m) Piping to turthest FCU fi (m)1 15(3s) Droo (OD above lD)ft (m)65(20) Lift (OD below lD)ft (m)6s(20) Pipe Connection Size - I iduid in (mm)1/4.4(6.3s'4) Pipe Connection Size - Suction in (mm)1t2'2+ 3t8'Z 112.7'2+9.52|2\ Refrigerant ype R4lOA Charoe lbs (kq)10.13 (4.6) EEV Electrical Voltaoe, Phase, Cyde V/Ph/Hz Power Supply lndoor unit powered from outdoor unit MCA A. MOCP - Fuse Ratinq A.50 Compressor TlPe R4lOA Model ATO36ODlUMU ESTER OIL VG74 Oil Charoe Ft. oz.4l Rated Cunent RLA 21 Outdoor Unit Width 41.15 (1045) Unit Heiqht in (mm)52.48 1 333) Unit DeDth in (mm)17.63 (448) Net Weioht 221.6 100.5) Airflow CFM Sound Pressure 64 Two Zones rree Zonos Four Zones 9+18 9+9+9 9+24 9+9+'12 9+9+9+12 12+12 r+9+18 9+9+9+18 12+18 9+g+24 9+9+9+24 12+24 l+12+12 9+9+12+12 18+18 9+12+18 9+9+12+'l 18+24 9+12+24 9+9+12+24 24+24 9+1 8+1 8 9+9+18+1 9+18+24 9+9+18+24 +24+24 9+12+'12+12 12+12+12 9+12+12+'8 12+12+'18 9+12+12+24 2+12+24 9+12+18+18 12+18+18 9+18+18+1 8 12+18+24 12+12+12+'12 2+24+24 12+12+12+18 1 8+18+18 1 '+18+24 12+12+18+18 Catalog No: 38MGR-36{4SB SUBJECT TO CHANGE WITHOUT NOTICE Page2 Rsplacss: 38MGR-3G03SB ! Construction View Outdoor Model: 38MGRQ36D-3 Moster Volve Moster Vqlve l'. N(() 2.es(76) 7.63( @ F t\o tl' tt 045' o0) 5Dtol 'ri Catalog No: 38MGR-36-04S8 4.21 orO ao tO lO olo copyright 2019 cAc/BDP . Atanta, GA30339 Edition Dats: 11/2019 I SUBJECT TO CHANGE WITHOUT NOTICE Page 3 "@- Repla@s: 38MGR-36{3SB ^uDt --^-,-.-^d h.l Ltl( lrilaiJ Cassette Heat Pump Ductless System 40MBCQ18---3lndoor Model Submittal Data Job Buyer: Unit Number: Buyer P.O. #: Location: Canier Model Date: STANDARD FEATURES Modes: Gool, Heati Dry, Fan, Auto Louver Control (Fixed or Swing) Outside Air lntake Built-in condensate Lift pump Follow Me (senses temperature at handheld remote) Heating Setback (46' F Heating Mode) Quiet indoor operation Aluminum Golden Hydrophilic pre-coated fins Controlsl Wireless Remote Controller included with indoor unit Optional Wired Remote Controller (Timer Function) Optional Wired Remote Controller KSACNOSO1AAA (7 Day programmable) LIMITED WARRANry- . 10 year limited to original purchaser on compressor and parts upon timely registration, otheMise 5 years 'For residential applications. See wananty for full details. Catalog No: 40MBCQ-1 8-3-0258 Performance Data Certified BY: - For Compatibility See Product Data Performance may vary based on the outdoor unit matched to. See compatible outdoor units pages for Performance Data. Copydghl 2016 CAC/BDP . 7310 W. Moris St. lndianaPolis, lN 46231 Edition Date:0U2018 System Size 18 lndoor Model 4oMBCQ18-3 Electrical Voltage, Phase, Cycle VlPhlHz 208/230-160 lndoor unit MCA A.0.2 Controls Wireless Remote Controller ('Fl'C Convertible)Standard Remote Controller Optional Operating Range Coolino lndoor DB Min -Max 'F('C)63-s0 (17-32) Heatins lndoor DB Min -Max 'FCc)32-86 (0-30) Piping Pipe Connection Size - Liquid in (mm)1/4 (6.35) Pipe Connection Size - Suction in (mm)1t2 (12.7) lndoor Coil Face Area Sq. Ft.3.10 No. Rows 2 Fins per inch 19 Circuits 4 lndoor Body Unit Width in (mm)22.44 (.570) Body Unit Heisht in (mm)10.24 (260\ Body Unit Depth in (mm)22.44 (s70) Body Net Weight lbs (ks)39.68 (18) Panel Unit Width in (mm)25.47 (il7) Panel Unit Heiqht in (mm)1.97 (50) Panel Unit Depth in (mm)25.47 (il7\ Panel Net Weight lbs (ks)5.51 (2.5) 3 Airflow (low to high)CFM 290t3501420 Sound Pressure (lowest to highest)dB(A)46t48t50 Air throw Data ft (m)30 (e) Moisture removal PinUh (uh)4.26 (2.02) Field Drain Pipe Size o.D.in (mm)1(2s.4) SUBJECT TO CHANGE WITHOUT NOTICE Page 1 R€plaes: 4oMBCQ-18-3-01 SB ? I KSACNO1OlAAA Wired Remote Control with Timer Function KSACNOsOlAAA Wired Remote Control 7 day Programmable KSAIFO4OlAAA wi-Fiil Kit KSA|C0101230 24V lnterface Kit 208/230V 4OMBCQOl)OCrc Grille/Ceiling panel 53DS-900-008 lnsulated 25' Line Sel - 114" x 112" Accessories Construction View 3iot G.Elirh OJtrrra fir lliak orrlaDdr Prf,l Copyrighl 201E CAC/BDP . 7310 W. tilonis St. lndianapolis, lN 46231 Drrin IEl! ks.trrba i Dor /r-gm,lEla DmU /r-iEt rll hilgd Drrin Flf, Edition Oats:03/20'18 lMrirlg firarrbn pori .@" Catalog No: 4oMBCQ-i 8-3-0258 r T F C c ro_2/t(2!o) g l- lttrE I 6.-aN a.17{a,7l A.tP, cERTrFrED... SUBJECT TO CHANGE WITHOUT NOTICE Page2 Repla6s: 40MBCO-18-3-01S8 q5-- SRSkrd ?1G?S ,\corEnergy Recovery Ventilators HRVCR Heat Recovery Ventilators ERVCR Product Data A05229 ERVCRSVB1I00,HRVCRSVBllOO 405330 ERVCRSHB 1100, rrRVCRSHB1100 ERVCRLHB12OO, The Cdr@ Heat Recovery Ventilation (HRV) and Energy Recovery Ventilator @RV) systems are the finest on the market today. These units provide efficient and cost effective heat recovery during the heating season when needed most. As temperatures drop below 23'F (-5'C), indoor air is recirculated periodically through the heat exchanger core to prevent frost from forming.* Competitors' methods of supplementary electric defrost waste energy. Unlike rotary wheel heat exchangers which mix air sheams, these cross-flow or counterflow heat exchangers ensure that there is no mixing of the stale air stream with the fresh outdoor air stream. A filter installed on the incoming outdoor air stream removes large airbome particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required. The units' acoustically engineered design make C6r@ ventilators the quiotest on the market and ensures that comfort is felt, not heard. Unlatching two (2) suitcase style latches allows easy removal of the filters and core for cleaning on most units. NOTE: The unit should not be installed in an attic or unconditioned space unless provisions are made for drain line fueez-ng and condensation. A12338 HRVCRSVUIlsT A\3212 ERVCRNVA A10299 FEAIURES *gBv. Energy saving defrost cycle . Cross-flow, counterflow heat exchangers . One filter on incoming air; one filter on outgoing air to protect core . Acoustical desrgn . Polypropylene heat exchanger core ERV . Integrated airflow balancing pointst . Integrated fumace interlock* . High pressure blowers . Onboard control for continuous highAow ventilator operation . Energy saving defrost cyclei . Cross-flow, counterflow heat exchangers . One filter on incoming air; one filter on outgoing air to protect core . No-tools maintenance . Enthalpic heat exchanger core . ERVCRNVA model uses EAC terminals to interlock with furnace blower for constant ventilation tExcept ERVCRNVA *+r o o o o ITRVCRLHBl25O o o o o ERVCRLHBL2O0, HRVCRLHB1ls0, ITRVCRLHB12s0 39'(991 mm) 34'(864 mm) 1. Fresh air to house. 2. Exhaust air from house. 3. Fresh air from outside. 4. Exhaust air to outside. 35'(891 mm) 3014 (768 mm) 17rli (438 mm) mm) 17' 6', (152 mm) 17W (138 nml o (152 mm) mm) 17', 412341 PHYSICAL & ELECTRICAL DATA DEFROST OPERATION ERV o o o o HRV CAPACTTY (LO-HD CORE MODEL CFM US PORT LOC.TYPE AIR FLOW WEIGHT LBS. [KGI VOLTAGE MA)( POWER WATTS MAX AMPS ERVCRLHBl2OO 80 - 198 38-93 Ends Enthalpic transfer media Cross flow 76 [35]12016011 2N 2.1 HRVCRLHBl 150 66 - 163 31-77 Ends Polypropylene Cross flow 6s [30]120lml1 160 1.5 HRVCRLHBl25O 82-20/.39-96 Ends Polypropylene Cross flow 65 [30]1201ffi11 195 2.1 MODEL OUTSIDE TEMPERATURE DEFROST CYCLE (l'rlN.)EXTENDED DEFROST CYCLES (MrN.) oc OF Dcfrosting Operatlon Tlme Betureen Each Detrost Cycle Defrosting Operatlon Tlme Between Each Defrost Cycle ERVCRLHBl2OO -5 -15 -27 23 5 -17 10 10 t0 60 30 20 't0 't0 10 30 20 't5 HRVCRLHBl 150 -5 _15 -27 23 5 -17 7 7 10 50 25 20 't0 10 't0 30 20 15 HRVCRLHBl2SO -5 -15 -27 23 5 -17 6 6 10 50 25 20 10 't0 10 30 20 15 5 _J\r ERVCRNVAI090 (CONT.) VENTILATION PERFORMANCE DEFROST This modd is NOT equipped with a deftost featurc. tt is desigDed only for use in IECC Climatc 7.onrsl thmugh 5, whictr EXCLIIDE the following statcs in thcir entircty: Montana" Wyoming, North Dakotq Minnesot4 Wisconsin, Vermon! New Hampshire, Maine. - Do not install this model in theee states. The following states have some areas in Climate Tarre 5: Washington, Idaho, Utah, Colorado, South Dakotq Iowa, Michigan, Pennsylvania, New Yorh Califomia. Prior to installing this model in these stats, rcfer to the IECC Climate Zone Map to ensur€ that the installation location is within Climate Zones I through 5. (See Fig. 1.) 9 Return Pressure inches w.c. Ext. Duct Pressure inc+les w.c. ERV Fan Speed Setting Low Medium Hlt Supply Exhaust Supply Exhaust Supply Exhaust {.1 0.1 74 69 104 122 12'l 148 o.2 60 58 99 110 116 139 0.3 58 51 94 101 1't2 128 0.4 87 92 107 120 0.5 69 72 111 4.2 0.1 93 62 120 116 136 143 0.2 86 51 115 104 133 132 0.3 71 110 94 127 122 o.4 60 101 86 123 112 0.5 96 76 119 0.6 89 67 115 0.7 83 111 0.8 76 0.9 70 't.0 E4 {t.3 0.1 110 il 135 110 150 137 o.2 104 130 98 147 127 0.3 91 126 88 142 116 0.4 81 113 81 133 0.5 71 109 70 't28 0.6 61 104 60 121 o.7 51 85 50 116 0.8 86 0.9 81 1.0 73 1.1 66 1.2 59 1.3 52 {.4 0.1 150 103 163 132 o.2 146 92 160 122 0.3 141 82 'r56 111 0.4 127 74 143 101 0.5 123 64 140 0.6 '114 55 133 o.7 108 128 0.8 102 124 0.9 93 116 1.0 86 110 1.1 79 1.2 71 1.3 64 1.4 57 h ACCESSORIES VENTILAIOR ACCESSORY NUMBER NOMENCI.AIURE 1234567t91011L2 KVACNOlOlCBA Product KV - Ventilator Accessory Kit Series A-Series TYpe AC01 - Accessory CN01 - Conhol TM01 - Timer Control Description CBA - C6r@ Basic Control CI-A - C6r@ Latent Control COA - C6r@ OneTouch Control CSA - C6r@ Standard Control Accessory DescriPtion HCO - Hood Concentric HOD - Intake Hood KIT - Airflow Measuring Kit 6FM - Flow Collar 6-in. 7FM - Flow Collar 7-in. 8FM - Flow Collar 8-in. Timer Description CIA - 20 Minute Timer Kit AC01 - Package Quantity 01-Pack 54321 0 r,M3.*uih HEIE ,\cor oo o m ^,\cor os (ormcuumr @ ,\co (.' a u JT .,\cor o g ,\cf] WHERE USEDKIT NUMBER DESCRIPTION# Used with HRVS1I(/ACN0101CBA Standard Wall Control Latent Wall Control Used with ERVS2l(/AcN0101Clr Used with ERVs and HRVs as a main wall controlOneTouch Control3r(/AcNo101COA Used with HRVsl(/AcNo101csA Basic Wall Control4 Used with ERVs and HRVs when 20 minut€ manual operation is required5I(/ATMo101CTA 20 Minuto Push Button Timer 13 i I II J I I I I I i I I I I .J t- I I tii I I I lL I r_l-I t -+rri-+-; il I I l 1- I I rrrlll4--+--F----t---F lrrrll I I I I I ! i ---J- I -+-+--r- -t I I I I I rl ilri'll I riti I I I llll I I )ti I I I f- Iii i --r- I ll I I -r,i I i J-l I I f'- lt I i rl i I I