HomeMy WebLinkAboutPermit Mechanical 2019-12-06OREGON
Web Address: www.springfield-or. gov
Building Permit
Commercia! Mechanical
Permit Number: 81 1-19-OO27 27 -MECH
IVR Number: 811044505989
City of Springfield
Development and Public works
225 Fifth Street
Springfield, OR 97477
541-726-3753
Email Add ress: permitcenter@springfield-or.9ov
SPRINGFIELD
{6
Permit Issued: December 06,2OL9
Category of Construction: Commercial
Submitted Job Value: $8,000.00
Description of Work: 2-head ductless HP and ERVI-OSA
Type of Work: Alteration
Worksite Address
4110 OLYMPIC ST
Springfield, OR 97478
Parcel
1702300000402
Owner:
Address:
Owner:
Address:
GAIL DANNEN SURVIVORS
TRUST
1950 LAKEVIEW DR
EUGENE, OR 97408
MARSHALL W DANNEN II
FAMILY TRUST
1950 LAKEVIEW DR
EUGENE, OR 97408
Business Name
MARSHALLS INC - Primary
License
ccB
License Number
25790
Phone
54L-747-7445
Inspection
2999 Final Mechanical
2999 Final Mechanical
2300 Rough Mechanical
fnspection Group
Mech Com
Mech Com
Mech Com
Inspection Status
Pending
' Pending
Pending
Various inspections are minimally required on each project and often dependent on the scope of work. Contact
the issuing jurisdiction indicated on the permit to determine required inspections for this project.
Schedule or track inspections at www.buildingpermits.oregon.gov
Call or text the word "schedule" to 1-888-299-2821 use IVR number: 811044505989
Schedule using the Oregon ePermitting Inspection App, search "epermitting" in the app store
permits expire if work is not started within 180 Days of issuance or if work is suspended for 180 Oays or longer depending on
the issuing agency's policy,
All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not.
Granting of a permit does not presume to give authority to violate or cancel the provisions of amy other state or local law
regulating construction or the performance of construction.
ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set
forth in OAR 952-001-0O1O through OAR 952-OO1-OO9O. You may obtain copies of the rules by calling the Center at (5O3)
232-L947.
All persons or entities performing work under this permit are required to be licensed unless exempted by ORS 7O1.O1O
(structurauilechanical), oRs 479.540 (Electrical), and oRs 693.o10-o20 (Plumbing).
printed on: 1216/19 page 1 of 2 C:\myReports/reports//production/01 STANDARD
h^l^a
TYPE OF WORK
,OB SITE INFORITIATION
LICENSED PROFESSIONAL IN FORMATION
PENDING INSPECTIONS
SCH EDULING INSPECTIONS
Permit Number: 81 1-19-0027 27 -MECH Page 2 of 2
Fee Description
Technology Fee
Commercial mechanical permit (based on mechanical job value)
State of Oregon Surcharge - Mech (t2o/o of applicable fees)
Printed on: 1216/19 Page 2 of 2
Quantity Fee Amount
$s,03
$180.60
$2L.67
$21 1.30Total Fees:
C :\myReports/reports//production/01 STANDARD
PERMIT FEES
SPRINGIIELD
nfi
OREGON
www. sprin gf ield-or. gov
Worksite address: 41 10 OLYMPIC ST, Springfield, OR 97478
P ar cr-l'. I 7 02300000402
Transaction Receipt
811-19402727-MECH
IVR Number: 81 I 044505989
Receipt Number: 473214
Receipt Date: 1216/19
City of Springfield
Development and Public Works
225 Fifth Street
Springfield, OR 97477
541-726-3753
permitcenter@springfi eld -or. gov
Fees Paid
Transaction Units
date
't2t6t19 1.00 Ea
Description
Commercial mechanical permit (based
on mechanical job value)
State of Oregon Surcharge - Mech
(12o/o ol applicable fees)
Account code
224-00000- 425604- 1 03 1
821 -00000-21 5004-0000
204-00000 -425605-0000
Fee amount
$180.60
$21.67
$9.03
Paid amount
$180.60
$21.67
$9.03
12t6t19 1.00 Ea
12t6t19 1.00 Automatic Technology Fee
Payment Melhod Credit card
authorization: 02800q
Payer: MARSHALLS INC Payment Amounl:$211.30
Cashier: Chris Carpenter Receipt Total:$2,l r.30
Printed: 1216/19 3:35 pm Page 1 of 'l Fl N_TransactionReceipt_pr
\r ^r-
Crry oF SprNGFIELn, ORncoll
Mechanical Permit A lication
225 Fifth Strect I Springfield, OR 97477 . PH(541)726-3753 r FAX(541)726-3689
This permit is issued under OAR 918-440-0050. Permits expire if work is not started within 180 days of issuance or if work is
suspended for 180 days.
CATEGORY OF CONSTRUCTION
E Residential ! Govemment ffi Commercial
JOB SITE INFORMATION AND LOCATION
Job site address
itut"i6yt zrP:QlJlf,
Reference
I
DESGRIPTION OF WORK
br,0 b(L U- *f Xrr+r -6-Lj
PROPERTY OWNER
Name:4zf " CL+fuyO t2A{F\NfU\)
Address: jo f- lA k14J Jf UndVIL-
City: (|rtfl-f?rrNf{-State: pl,Q-z\dlyt6t I
Phone:ftl/ 6.lZ - 11Ci7-Fax
E-mail
This installation is being made on property owned by me or a
member of my immediate family, and is exempt from licensing
requirements under ORS 701.010.
CONTRACTOR INSTALLATION
Business name:t NU
Address oL'
City: <--??t-l.l State: (!/l ztv:Q'll'lf,
Phone:Fax:
E-mail:
CCB license no.
Print name
Signature
5PR!HGF'ELO
*,
DEPARTMENT USE ONLY
Permitno.:\11-2J7'l
Date:/'L//" / t9
FEE SCHEDULE
Residential Qty.Cost
ea.
Totel
cost
il02-00 sFirst Aooliance
Furnace/burner includine ducts and vents
823.00 $Up to 100k BTU,4rr
t26.00 $Over l00k BTU/hr,
If p*f ers/sf oves/venf s
$23.00 $Unit heater
Wood/pellet/gas stove/flue $54.00 $
$r9.00 $Evaporated cooler
$r3.00 $Vent fan with one duct/appliance
Hood with exhaust and duct $19.00 $
One to four outlets $9.00 $
$s.00 $Additional outlets (each)
$1s.00 $Up to 10,000 CFM
Over 10.000 CFM $26.00 $
Compressor/absorntion svstem/heat nump
Up to 3 hp/100k BTU t23.00 s
Up to l5 hp/500k BTU $41.00 $
Up to 30 hp/l,000 BTU $61.00 $
Up to 50 hp/1,750 BTU t78.00 $
sOver 50 hp/I,750 BTU 1132.00
Incinerators
Domestic incinerator $26.00 $
Gommercial
Enter total valuation ofmechanical svstem
and installation "o"ss*, 6b)
Enter fee based on valuatiori of mechanical system, etc.$
Miscellaneous fees Cost
ea.
Total
cost
1102.00 $Reinspection
Specially requested inspections (per t102.00 $
t19.00 $Regulated cquipment (unclassed)
Each additional inspection: (l)t102.00 $
$d7)g(A) Enter subtotai ofabove fees (or enter set
minimum fee of $ 102.00)
(B) Investigative fee $
(C) Enter l2%o surcharge (.12 x [A+B])$
(D) Seismic fee, lo/o (.01 x [Al)$
(E) Technology Fee (5% oflAl)$
TOTAL fees and surcharges (A through E)s) lt 5,)
Lasr edited 7/l/2019 BJoncs
Taxlot.:
sAir-handlins units. includins duc
DEPARTMENT USE
GOMcheck Software Version 4.0.3.1
Mechanical Gompliance Certificate
Section 1: Project lnformation
Energy Code: 2009 IECC
Project Title: Marshall's Office Expansion
Project Type: Alteration
Construction Site:
4110 Olympic Street
Springfield, OR 97478
Permit No. 1 9-001502.STR
Section 2: General lnformation
Building Location (for weather data):
Climate Zone:
Owner/Agent:
M. Chad Dannen
Marshall's inc.
4110 Olympic Street
Springfield, OR 97478
541-747-7445
chad@marshallsinc.com
Springfield, Oregon
4c
Designer/Contractor:
M. Chad Dannen
Marshall's lnc.
4110 Olympic Street
Springfield, OR 97478
541-747-7445
chad@marshallsinc.com
Section 3: Mechanical Systems List
Quantity System Type & Descriotion
1 HVAC System 1 (Single Zone) : Split System Heat Pump
Heating Mode: Capacity = 36 kBtu/h,
Proposed Efficiency = 10.50 HSPF, Required Efficiency = 7.70 HSPF
Cooling Mode: Capacity = 36 kBtu/h,
Proposed Efficiency = 21.50 SEER, Required Efficiency = 13.00 SEER
Fan System: None
Section 4: Requirements Checklist
Requirements Specific To: HVAC System I :
fr 1. Equipment minimum efficiency: Heat Pump: 7.70 HSPF 13.00 SEER
Generic Requirements: Must be met by all systems to which the requirement is applicable:
gl_ 1 . Plant equipment and system capacity no greater than needed to meet loads
" Exception(s):
tr Standby equipment automatically off when primary system is operating
tr Multiple units controlled to sequence operation as a function of load
6, 2. Minimum one temperature control device per system
q 3. Minimum one humidity control device per installed humidification/dehumidification system
p 4. Load calculalions per ASHRAE/ACCA Standard 183.
g 5. Automatic Controls: Setback to 55'F (heat) and 85'F (cool); 7-day clock, 2-hour occupant override, 10-hour backup' Exception(s):
tr Continuously operating zones
p 6. Outside-air source for ventilation; system capable of reducing OSA to required minimum
g 7. R-5 supply and return air duct insulation in unconditioned spacesr R-8 supply and return air duct insulation outside the building
R-8 insulation between ducts and the building exterior when ducts are part of a building assembly
Exception(s):
Ei Ducts located within equipment
tr Ducts with interior and exterior temperature difference not exceeding 15"F.
Project Title: Marshall's Office Expansion
Data filename: Untitled.cck
Report date: 12106119
Page 1 of 3
M L Mechanical fasteners and sealants used to connect ducts and air distribution equipment{}I.fi S. Ouas sealed - longitudinal seams on rigid ducts; transverse seams on all ducts; UL 18'lA or 181B tapes and mastics
g 10. Hot water pipe insulation: 1 .5 in. for pipes <=1 .5 in. and 2 in. for pipes >1 .5 in.
Chilled water/refrigeranUbrine pipe insulation: 1.5 in. for pipes <=1.5 in. and 1.5 in. for pipes >1.5 in.
Steam pipe insulation: 1.5 in. for pipes <=1 .5 in. and 3 in. for pipes >1 .5 in.
Exception(s):
tr Piping within HVAC equipment.
tr Fluid temperatures between 55 and 105"F.
tr Fluid not heated or cooled with renewable energy.
tr Piping within room fan-coil (with AHR|440 rating) and unit ventilators (with AHR|840 rating).
tr Runouts <4 ft in length.
q t l.Operation and maintenance manual provided to building owner
g l2.Balancing devices provided in accordance with IMC 603.17
g 1 3. Demand control ventilation (DCg present for high design occupancy areas (>40 person/1 000 fl2 in spaces >500 ft2) and served by
systems with any one of 1) an air-side economizer, 2) automatic modulating control of the outdoor air damper, or 3) a design outdoor
airflow greater than 3000 cfm.
Exception(s):
B Systems with heat recovery.
tr Multiple-zone systems without DDC of individual zones communicating with a central control panel.
tr Systems with a design outdoor airflow less than 1200 cfm.
tr Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm.
l!,14.Motorized, automatic shutoff dampers required on exhaust and outdoor air supply openings<
Exception(s):
tr Gravity dampers acceptable in buildings <3 stories
g lS.Automatic controls for freeze protection systems presenl
g 16. Exhaust air heat recovery included for systems 5,000 cfm or greater with more than 70olo outside air fraction or specifically exempted
Exception(s):
tr Hazardous exhaust systems, commercial kitchen and clothes dryer exhaust systems that the lntemational Mechanical Code
prohibits the use of energy recovery systems.
tr Systems serving spaces that are heated and not cooled to less than 60'F.
tr Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy.
tr Heating systems in climates with less than 3600 HDD.
D Cooling systems in climates with a 1 percent cooling design wet-bulb temperature less than 64'F.
tr Systems requiring dehumidification that employ energy recovery in series with the cooling coil.
tr Laboratory fume hood exhaust systems that have either a variable air volume system capable of reducing exhaust and makeup air
volume to 50 percent or less of design values or, a separate make up air supply meeting the following makeup air requirements:
a) at least 75 percent of exhaust flow rate, b) heated to no more than 2"F below room setpoint temperature, c) cooled to no lower
than 3"F above room setpoint temperature, d) no humidification added, e) no simultaneous heating and cooling.
Section 5: Compliance Statement
Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans,
specifications and other calculations submitted with this permit application. The proposed mechanical alteration pro.iect has been designed
to meet the 2009 IECC, Chapter 8, requirements in COMcheck Version 4.0.3.1 and to comply with the mandatory requirements in the
Requirements Checklist.
VL OA$.INt4r\) C,(4-b /z . 07, k)/r
Name - Title Signature Date
Section 6: Post Construction Gompliance Statement
tr HVAC record drawings of the actual installation, system capacities, calibration information, and performance data for each equipment
provided to the owner.
tr HVAC O&M documents for all mechanical equipment and system provided to the owner by the mechanical contractor.
tr Written HVAC balancing and operations report provided to the owner.
The above post construction requirements have been completed.
Project Title: Marshall's Office Expansion
Data filename: Untitled.cck
Report date: 12106119
Page 2 of 3
/4r4-
Outdoor Unit Multi-zone Heat Pump Ductless System
38MGRQ36D-.3Outdoor Model:
Submittal Data
Job Data
Buyer:
Unit Number:
Performance Data Certified By:
Table
Copyright 2019 CAC/tsDP . Atlar{a, G430339
Buyer P.O. #:
Location:
Carrier #:
Model Number:
Date:
MULTIZONE STANDARD FEATURES
Features Outdoor:
. Connect up to 4, multiple style indoor units
High Wall
Cassette
Ducted
Console
. 100o/o Heating Capacity at 5' F G15'C)
. Variable Speed (lnverter) Compressor
. Basepan Heater factory installed
. Quiet operation
. Aluminum Golden Hydrophilic pre-coated fins
Cooling operating range -13"-122' F (-25'-50' C)
Heating operating range -22"-86' F G30'-30'C)
LIMITED WARRANTT
. 10 year limited to original purchaser on compressor and parts upon
timely registration, otherwise 5 years
*For residential applications. See wananty for full details.
see Product Data
PHASED OUT
INDOOR UNITS
Catalog No: 38MGR-36-04S8
r:1
For matched
Edition Dat6: ltl2019
tO
INDOOR UNIT
4OMPHAOOgXA3 619PHAO09XA3 DHMPHAQO9XA3
DHMPHAQl2XA34OMPHAQ12XA361gPHAO12XA3
61gPEQOOgBBMA DHMSHAQO9XA340MAQB09B-3
4OMAQB12B-3 619PEQO,,I28BMA DHMSHAQl2XA3
61gPEQO18BBMA DHMSHAQlSXA34OMAQB18B_3
4OMAQB24B-3 619PEQO24BBMA DHMSHAQ24XA3
40MHHQ09--3
4OMHHQ12-A
40MHHO18---3
High Wall
40MHHQ24--3
40MBQB09C-3 61gREQOOgCBMA 40MBCQ09--3
4oMBQB12C-3 61SREQO12CBMA 4oMBCO12--3
61gREQO18CBMA 40MBCQ18--34oMBQB18C-3
40MBCO24---3
Cassette
4OMBQB09D-3 40MBDQ09--3
4OMBQB12D-3 61gREQOl2DBMA 40MBDQ12--3
4OMBQB18D-3 61gREQO18DB[iA 4oMBDQ18--3
61gREOO24DBMA 40MBDQ24--3
Ducted
40MBOB24D-3
40MBQBOgF-.3 619REQ009FB[,|A 4OMBFQOS-€
4OMBQB,I2F-3 61gREQO12FBMA 4oMBFO12---3
40MBFQ18--3
Console
40MBFO24--3
SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces: 38MGR-36-O3SB
I
S cifications
Rated Gombinations
Copyright 2019 CAC/BDP o Adanta, GA30339 Edition Date: 1'll2019
36Size
Outdoor Model 38MGRQ36D-3
4
s),€tem
YESEnergy Star
3.0Tons
Btu/h 36,000Cooling Rated Capacity
Btu/h 8,560-45,020Cooling Cap. Range Min - Max
21.5SEER
13.5EER
Btu/h 36,000Heatino Rated capacity (47'F)
36.660Heatino Maximum Capactty (5'F)Btu/h
Heatino Cap. Range Min - Max Btu/h 7,21 0-50,350
10.5HSPF
coP (47'F)W^^/3.8
W/W 1.78
Performance
Non-Ducted
coP (5'F)
NOEnergy Star
3.0
Btr/h 36.000Coolinq Raied Capacity
8.s10-42.635Coolino CaD. Ranoe Min - Max Btu/h
20.25SEER
12.4EER
36.400Heatino Rated Caoacitv (47"F)Btu/h
Capadty (5'F)Btu/h 36,065
Btu/h 7.045-47.800Heatinq Cap. Ranqe Min - Max
HSPF 21.5
W/w 3.7coP (47'F)
coP (5'F)Wrw 1.76
Perfomancs
Combination
Ducted and
Non-Ducted
NOEnergy Star
3.0
Btu/h 36,000Coolins Rated Capaciv
8.460-40.250Coolino CaD. Ranoe Min - Max Btu/h
iEER t9
11.3EER
37.000Heatinq Rated Caoacitv (47"F)Btu/h
Heatino Maximum Caoacitv (5'F)Btu/h 35,470
Btu/h 6.880-45.250Heatino cap. Ranoe Min - Max
HSPF 11
W/w 3.6coP (47'F)
1.75
Performance
DuctBd
)oP (5'F)W/W
Operating
Range
Cooling Outdoor DB Min -
Max 'Frc)-13-122(-25-50)
Heating Outdoor DB Min -
Max
'Ffc)-22-86 (-30-30)
Piping
Total PiDinq Lenoth ft (m)
Piping to turthest FCU fi (m)1 15(3s)
Droo (OD above lD)ft (m)65(20)
Lift (OD below lD)ft (m)6s(20)
Pipe Connection Size -
I iduid in (mm)1/4.4(6.3s'4)
Pipe Connection Size -
Suction in (mm)1t2'2+ 3t8'Z
112.7'2+9.52|2\
Refrigerant
ype R4lOA
Charoe lbs (kq)10.13 (4.6)
EEV
Electrical
Voltaoe, Phase, Cyde V/Ph/Hz
Power Supply lndoor unit powered
from outdoor unit
MCA A.
MOCP - Fuse Ratinq A.50
Compressor
TlPe R4lOA
Model ATO36ODlUMU
ESTER OIL VG74
Oil Charoe Ft. oz.4l
Rated Cunent RLA 21
Outdoor
Unit Width 41.15 (1045)
Unit Heiqht in (mm)52.48 1 333)
Unit DeDth in (mm)17.63 (448)
Net Weioht 221.6 100.5)
Airflow CFM
Sound Pressure 64
Two Zones rree Zonos Four Zones
9+18 9+9+9
9+24 9+9+'12 9+9+9+12
12+12 r+9+18 9+9+9+18
12+18 9+g+24 9+9+9+24
12+24 l+12+12 9+9+12+12
18+18 9+12+18 9+9+12+'l
18+24 9+12+24 9+9+12+24
24+24 9+1 8+1 8 9+9+18+1
9+18+24 9+9+18+24
+24+24 9+12+'12+12
12+12+12 9+12+12+'8
12+12+'18 9+12+12+24
2+12+24 9+12+18+18
12+18+18 9+18+18+1 8
12+18+24 12+12+12+'12
2+24+24 12+12+12+18
1 8+18+18
1 '+18+24 12+12+18+18
Catalog No: 38MGR-36{4SB
SUBJECT TO CHANGE WITHOUT NOTICE Page2 Rsplacss: 38MGR-3G03SB
!
Construction View
Outdoor Model: 38MGRQ36D-3
Moster Volve Moster Vqlve
l'.
N(()
2.es(76)
7.63(
@
F
t\o
tl'
tt
045'
o0)
5Dtol
'ri
Catalog No: 38MGR-36-04S8
4.21
orO
ao
tO
lO
olo
copyright 2019 cAc/BDP . Atanta, GA30339 Edition Dats: 11/2019
I
SUBJECT TO CHANGE WITHOUT NOTICE Page 3
"@-
Repla@s: 38MGR-36{3SB
^uDt --^-,-.-^d h.l Ltl( lrilaiJ
Cassette Heat Pump Ductless System
40MBCQ18---3lndoor Model
Submittal Data
Job
Buyer:
Unit Number:
Buyer P.O. #:
Location:
Canier
Model
Date:
STANDARD FEATURES
Modes: Gool, Heati Dry, Fan, Auto
Louver Control (Fixed or Swing)
Outside Air lntake
Built-in condensate Lift pump
Follow Me (senses temperature at handheld remote)
Heating Setback (46' F Heating Mode)
Quiet indoor operation
Aluminum Golden Hydrophilic pre-coated fins
Controlsl
Wireless Remote Controller included with indoor unit
Optional Wired Remote Controller (Timer Function)
Optional Wired Remote Controller KSACNOSO1AAA (7 Day
programmable)
LIMITED WARRANry-
. 10 year limited to original purchaser on compressor and parts upon
timely registration, otheMise 5 years
'For residential applications. See wananty for full details.
Catalog No: 40MBCQ-1 8-3-0258
Performance Data Certified BY:
-
For Compatibility See Product Data
Performance may vary based on the outdoor unit matched to. See compatible outdoor units pages for Performance Data.
Copydghl 2016 CAC/BDP . 7310 W. Moris St. lndianaPolis, lN 46231 Edition Date:0U2018
System Size 18
lndoor Model 4oMBCQ18-3
Electrical
Voltage, Phase, Cycle VlPhlHz 208/230-160
lndoor unit
MCA A.0.2
Controls
Wireless Remote Controller ('Fl'C Convertible)Standard
Remote Controller Optional
Operating
Range
Coolino lndoor DB Min -Max 'F('C)63-s0 (17-32)
Heatins lndoor DB Min -Max 'FCc)32-86 (0-30)
Piping Pipe Connection Size - Liquid in (mm)1/4 (6.35)
Pipe Connection Size - Suction in (mm)1t2 (12.7)
lndoor Coil
Face Area Sq. Ft.3.10
No. Rows 2
Fins per inch 19
Circuits 4
lndoor
Body Unit Width in (mm)22.44 (.570)
Body Unit Heisht in (mm)10.24 (260\
Body Unit Depth in (mm)22.44 (s70)
Body Net Weight lbs (ks)39.68 (18)
Panel Unit Width in (mm)25.47 (il7)
Panel Unit Heiqht in (mm)1.97 (50)
Panel Unit Depth in (mm)25.47 (il7\
Panel Net Weight lbs (ks)5.51 (2.5)
3
Airflow (low to high)CFM 290t3501420
Sound Pressure (lowest
to highest)dB(A)46t48t50
Air throw Data ft (m)30 (e)
Moisture removal PinUh
(uh)4.26 (2.02)
Field Drain Pipe Size
o.D.in (mm)1(2s.4)
SUBJECT TO CHANGE WITHOUT NOTICE Page 1 R€plaes: 4oMBCQ-18-3-01 SB
?
I
KSACNO1OlAAA Wired Remote Control with Timer Function
KSACNOsOlAAA Wired Remote Control 7 day Programmable
KSAIFO4OlAAA wi-Fiil Kit
KSA|C0101230 24V lnterface Kit 208/230V
4OMBCQOl)OCrc Grille/Ceiling panel
53DS-900-008 lnsulated 25' Line Sel - 114" x 112"
Accessories
Construction View
3iot G.Elirh
OJtrrra fir lliak
orrlaDdr
Prf,l
Copyrighl 201E CAC/BDP . 7310 W. tilonis St. lndianapolis, lN 46231
Drrin IEl!
ks.trrba i
Dor
/r-gm,lEla
DmU
/r-iEt rll hilgd
Drrin Flf,
Edition Oats:03/20'18
lMrirlg firarrbn pori
.@"
Catalog No: 4oMBCQ-i 8-3-0258
r T
F
C
c
ro_2/t(2!o)
g
l-
lttrE
I
6.-aN
a.17{a,7l
A.tP, cERTrFrED...
SUBJECT TO CHANGE WITHOUT NOTICE Page2 Repla6s: 40MBCO-18-3-01S8
q5--
SRSkrd ?1G?S
,\corEnergy Recovery Ventilators
HRVCR
Heat Recovery Ventilators
ERVCR
Product Data
A05229
ERVCRSVB1I00,HRVCRSVBllOO
405330
ERVCRSHB 1100, rrRVCRSHB1100
ERVCRLHB12OO,
The Cdr@ Heat Recovery Ventilation (HRV) and Energy Recovery
Ventilator @RV) systems are the finest on the market today. These
units provide efficient and cost effective heat recovery during the
heating season when needed most.
As temperatures drop below 23'F (-5'C), indoor air is recirculated
periodically through the heat exchanger core to prevent frost from
forming.* Competitors' methods of supplementary electric defrost
waste energy. Unlike rotary wheel heat exchangers which mix air
sheams, these cross-flow or counterflow heat exchangers ensure
that there is no mixing of the stale air stream with the fresh outdoor
air stream.
A filter installed on the incoming outdoor air stream removes large
airbome particles from the intake air stream before they enter the
heat exchanger and reduces the maintenance required. The units'
acoustically engineered design make C6r@ ventilators the quiotest
on the market and ensures that comfort is felt, not heard.
Unlatching two (2) suitcase style latches allows easy removal of the
filters and core for cleaning on most units.
NOTE: The unit should not be installed in an attic or
unconditioned space unless provisions are made for drain line
fueez-ng and condensation.
A12338
HRVCRSVUIlsT
A\3212
ERVCRNVA
A10299
FEAIURES
*gBv. Energy saving defrost cycle
. Cross-flow, counterflow heat exchangers
. One filter on incoming air; one filter on outgoing air to protect core
. Acoustical desrgn
. Polypropylene heat exchanger core
ERV
. Integrated airflow balancing pointst
. Integrated fumace interlock*
. High pressure blowers
. Onboard control for continuous highAow ventilator operation
. Energy saving defrost cyclei
. Cross-flow, counterflow heat exchangers
. One filter on incoming air; one filter on outgoing air to
protect core
. No-tools maintenance
. Enthalpic heat exchanger core
. ERVCRNVA model uses EAC terminals to interlock with furnace
blower for constant ventilation
tExcept ERVCRNVA
*+r o
o
o
o
ITRVCRLHBl25O
o
o
o
o
ERVCRLHBL2O0, HRVCRLHB1ls0, ITRVCRLHB12s0
39'(991 mm)
34'(864 mm)
1. Fresh air to house.
2. Exhaust air from house.
3. Fresh air from outside.
4. Exhaust air to outside.
35'(891 mm)
3014 (768 mm)
17rli (438 mm)
mm)
17'
6',
(152 mm)
17W (138 nml
o
(152 mm)
mm)
17',
412341
PHYSICAL & ELECTRICAL DATA
DEFROST OPERATION
ERV
o
o
o
o
HRV
CAPACTTY (LO-HD CORE
MODEL
CFM US
PORT
LOC.TYPE AIR FLOW
WEIGHT
LBS. [KGI VOLTAGE
MA)(
POWER
WATTS
MAX
AMPS
ERVCRLHBl2OO 80 - 198 38-93 Ends Enthalpic
transfer media Cross flow 76 [35]12016011 2N 2.1
HRVCRLHBl 150 66 - 163 31-77 Ends Polypropylene Cross flow 6s [30]120lml1 160 1.5
HRVCRLHBl25O 82-20/.39-96 Ends Polypropylene Cross flow 65 [30]1201ffi11 195 2.1
MODEL
OUTSIDE TEMPERATURE DEFROST CYCLE (l'rlN.)EXTENDED DEFROST CYCLES
(MrN.)
oc OF Dcfrosting
Operatlon Tlme
Betureen Each
Detrost Cycle
Defrosting
Operatlon Tlme
Between Each
Defrost Cycle
ERVCRLHBl2OO
-5
-15
-27
23
5
-17
10
10
t0
60
30
20
't0
't0
10
30
20
't5
HRVCRLHBl 150
-5
_15
-27
23
5
-17
7
7
10
50
25
20
't0
10
't0
30
20
15
HRVCRLHBl2SO
-5
-15
-27
23
5
-17
6
6
10
50
25
20
10
't0
10
30
20
15
5
_J\r
ERVCRNVAI090 (CONT.)
VENTILATION PERFORMANCE
DEFROST
This modd is NOT equipped with a deftost featurc. tt is desigDed only for use in IECC Climatc 7.onrsl thmugh 5, whictr EXCLIIDE
the following statcs in thcir entircty: Montana" Wyoming, North Dakotq Minnesot4 Wisconsin, Vermon! New Hampshire, Maine. - Do
not install this model in theee states.
The following states have some areas in Climate Tarre 5: Washington, Idaho, Utah, Colorado, South Dakotq Iowa, Michigan, Pennsylvania,
New Yorh Califomia. Prior to installing this model in these stats, rcfer to the IECC Climate Zone Map to ensur€ that the installation
location is within Climate Zones I through 5. (See Fig. 1.)
9
Return
Pressure
inches w.c.
Ext. Duct
Pressure
inc+les w.c.
ERV Fan Speed Setting
Low Medium Hlt
Supply Exhaust Supply Exhaust Supply Exhaust
{.1
0.1 74 69 104 122 12'l 148
o.2 60 58 99 110 116 139
0.3 58 51 94 101 1't2 128
0.4 87 92 107 120
0.5 69 72 111
4.2
0.1 93 62 120 116 136 143
0.2 86 51 115 104 133 132
0.3 71 110 94 127 122
o.4 60 101 86 123 112
0.5 96 76 119
0.6 89 67 115
0.7 83 111
0.8 76
0.9 70
't.0 E4
{t.3
0.1 110 il 135 110 150 137
o.2 104 130 98 147 127
0.3 91 126 88 142 116
0.4 81 113 81 133
0.5 71 109 70 't28
0.6 61 104 60 121
o.7 51 85 50 116
0.8 86
0.9 81
1.0 73
1.1 66
1.2 59
1.3 52
{.4
0.1 150 103 163 132
o.2 146 92 160 122
0.3 141 82 'r56 111
0.4 127 74 143 101
0.5 123 64 140
0.6 '114 55 133
o.7 108 128
0.8 102 124
0.9 93 116
1.0 86 110
1.1 79
1.2 71
1.3 64
1.4 57
h
ACCESSORIES
VENTILAIOR ACCESSORY NUMBER NOMENCI.AIURE
1234567t91011L2
KVACNOlOlCBA
Product
KV - Ventilator Accessory Kit
Series
A-Series
TYpe
AC01 - Accessory
CN01 - Conhol
TM01 - Timer
Control Description
CBA - C6r@ Basic Control
CI-A - C6r@ Latent Control
COA - C6r@ OneTouch Control
CSA - C6r@ Standard Control
Accessory DescriPtion
HCO - Hood Concentric
HOD - Intake Hood
KIT - Airflow Measuring Kit
6FM - Flow Collar 6-in.
7FM - Flow Collar 7-in.
8FM - Flow Collar 8-in.
Timer Description
CIA - 20 Minute Timer Kit
AC01 -
Package Quantity
01-Pack
54321
0
r,M3.*uih HEIE
,\cor
oo o
m
^,\cor
os (ormcuumr
@
,\co
(.'
a
u
JT
.,\cor
o
g
,\cf]
WHERE USEDKIT NUMBER DESCRIPTION#
Used with HRVS1I(/ACN0101CBA Standard Wall Control
Latent Wall Control Used with ERVS2l(/AcN0101Clr
Used with ERVs and HRVs as a main wall controlOneTouch Control3r(/AcNo101COA
Used with HRVsl(/AcNo101csA Basic Wall Control4
Used with ERVs and HRVs when 20 minut€ manual operation is required5I(/ATMo101CTA 20 Minuto Push Button Timer
13
i
I II
J
I
I
I
I
I
i
I
I
I
I
.J
t-
I I tii I I
I lL I r_l-I t
-+rri-+-;
il I
I
l
1-
I
I rrrlll4--+--F----t---F
lrrrll
I I
I
I
I !
i
---J-
I -+-+--r-
-t
I
I
I
I
I
rl ilri'll
I
riti
I
I
I llll
I
I
)ti
I
I
I
f-
Iii
i
--r-
I
ll
I I
-r,i I
i
J-l I I
f'-
lt
I
i rl i I
I