HomeMy WebLinkAboutPermit Building 2019-11-27OREGON
Web Address: www.sprinqfield-or.9ov
Building Permit
Residentia! 1 & 2 Fam Dwelling (New Only)
Permit Number: 811-19-002485-DWL
IVR Number: 811039699021
City of Springfield
Development and Public Works
225 Fifth Street
Springfield, OR 97477
547-726-3753
Email Address: permitcenter@springfield-or.gov
SPRINGTIELD
Permat Issued: November 27, 2OL9
Category of Construction: Single Family Dwelling Type of Work: New
Calculated Job Value: $230,922.88
Description of Work: New SFD Lot 1 Bridlewood SAME AS 4211 Horace
Worksite Address
4230 HORACE ST
Springfield, OR 97478
Parcel
180205240630 1
Owner:
Address:
BRUCE WIECHERT
CUSTOM HOMES INC
3073 SKWIEW LN
EUGENE, OR 97405
Busaness Name
BRUCE WIECHERT CUSTOM
HOMES INC - Primary
OREGON CUSTOM PLUMBING INC
COMFORT FLOW HEATING CO
L&EELECTRICINC
Lacense
CCB
ccB
ccB
ccB
License Number
LOt7L7
19 1 104
460
L05475
Phone
541-686-9458
541-434-Lt46
541-726-0100
541-933-2598
permits expire if work is not started within 180 Days of issuance or if work is suspended for 18O Days or longer depending on
the issuing agency's policy.
All provisions of laws and ordinances governing this Wpe of work will be complied with whether specified herein or not'
Granting of a permit does not presume to give authority to violate or cancel the Provisions of any other state or local law
regulating construction or the performance of construction.
ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center' Those rules are set
forth in OAR 952-OO1-OO1O through OAR 952-OO1-OO9O. You may obtain copies of the rules by calling the Center at (503)
232-1987.
All persons or entities performing work under this permit are required to be licensed unless exempted by ORS 7O1.O1O
(Structural/Mechanical), ORS 479.54O (Electrical), and ORS 593.O1O-O2O (Plumbing).
printed on: Ltt27/Lg page 1 of 5 C:\myReports/reports//production/01 STANDARD
h-r-t
t$
TYPE OF WORK
JOB SITE INFORMATION
LICENSED PROFESSIONAL IN FORMATION
PENDING INSPECTIONS
Permit Number: 81 1-19-O02485-DWL
Inspection
2999 Final Mechanical
3999 Final Plumbing
4999 Final Electrical
9504 Curbcut - Standard
9508 Sidewalk
1530 Exterior Shearwall
1260 Framing
2300 Rough Mechanical
3170 Underfloor Plumbing
4500 Rough Electrical
LO2O Zoning/Setbacks
1090 Street Trees
1110 Footing
1120 Foundation
1160 UFER Ground
1220 Underfloor Framing/Post and Beam
1410 Underfloor Insulation
1430 Insulation Wall
1440 Insulation Ceiling
1520 Interior Shearwall
1999 Final Building
2200 Underfloor Mechanical
2250 Gas Piping/Pressure Test
3130 Footing/Foundation Drains
3200 Sanitary Sewer
3300 Water Service
3400 Storm Sewer
3620 Backflow Device
3650 Shower Pan
4000 Temporary Power Service
4220 Electrical Service
Page 2 of 5
Inspection Group
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
Public Works
Public Works
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1 2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
1_2 Famdwell
Inspection Status
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Pending
Various inspections are minimally required on each project and often dependent on the scope of work. Contact
the issuing jurisdiction indicated on the permit to determine required inspections for this project.
Prinled on: lll27l79 page 2 0f 5 c:\myReports/reports//production/01 STANDARD
SCH EDULING INSPECTIONS
Permit Number: 81 1-19-OO24a5-DWL
Schedule or track inspections at www.build ing permits.oregon. gov
Call or text the word "schedule" to 1-888-299-2821 use IVR number: 811039699021
Schedule using the Oregon ePermitting Inspection App, search "epermitting" in the app store
Page 3 of 5
C :\myReports/reports//production/01 STAN DARDPage 3 of 5Printed on: 11/27l19
Permit Number! 81 1-19-002485-DWL Page 4 of 5
Fee Description
Residential wiring
Technology Fee
Air conditioner
Clothes dryer exhaust
Decorative gas fireplace
Furnace - up to 100,000 BTU
Gas fuel piping outlets
Range hood/other kitchen equipment
Ventilation fan connected to single duct
Water heater
Single Family Residence - Baths
Address assignment - each new or change requested externally, per each
SDC: Reimbursement Cost - Local Wastewater
SDC: Total MWMC Administration Fee - Local
SDC: Total Transportation Administration Fee
SDC: Total Sewer Administration Fee
SDC: Total Storm Administration Fee
SDC: Administrative Fee - MWMC Regional Wastewater SDC
SDC: Compliance Cost - MWMC Regional Wastewater SDC
SDC: Improvement Cost - MWMC Regional Wastewater SDC
SDC: Reimbursement Cost - MWMC Regional Wastewater SDC
SDC: Improvement - Transportation SDC
SDC: Reimbursement - Transportation SDC
SDC: Reimbursement Cost - Storm Drainage
SDC: Improvement Cost - Storm Drainage
SDC: Improvement Cost - Local Wastewater
Fire SDC - New Res Construction Sq Ft fee - enter sq ftg
Master plan review - second and subsequent reviews
Structural building permit fee
Willamalane fees - Single Family Detached, per unit
State of Oregon Surcharge - Bldg (12olo of applicable fees)
State of Oregon Surcharge - Elec (12olo of applicable fees)
State of Oregon Surcharge - Plumb (L2o/o of applicable fees)
State of Oregon Surcharge - Mech (t2o/o of applicable fees)
Curb cut and Sidewalk construction - multiple permit discount
Curb cut fee - enter # of cuts
Sidewalk construction - permit, first 90 linear feet
Ptinted oil Lll27l79 Page 4 of 5
Quantity
2158
1
1
1
1
4
1
3
1
3
1
4433
89.48
190.09
330.84
85.31
10
22.82
1620.85
135.93
36LL.72
190.06
695.91
10 10.34
2t83.74
2158
1
Fee Amount
$294.00
$167.93
$19.00
$13.00
$ 19.00
$23.00
$e'00
$19.00
$39.00
$19.00
$613,00
$s4.00
$4,433.00
$89.48
$190.09
$330.84
$8s.31
$10.00
$22.82
$1,620,85
$ 13s.93
$3,6Lt.72
$ 190.06
$695.91
$1,010.34
$2,L83.74
$129.48
$338.00
$ 1,691.56
$3,805.00
$202.99
$3s.28
$73. s6
$19.20
$-42,00
$12s.00
$12s.00
1
1
1
1
C: \myReports/reports//production/01 STAN DARD
PERMIT FEES
Permit Number: 81 1-19-002485-DWL
Total Fees:
Page 5 of 5
$22,402.09
Construction Type
P(inted oni ll/27 179
Occupancy Type
R-3 1&2family
U Utility, misc.
U Utility, misc. -
half rate
Unat Amount
L,674.O0
484.00
96.00
Unit
Tota! Job Value:
Job Value
$2O4,998.O4
$23,585.32
$2,339,52
$230,922.88
C :\myReports/reports//production/0 1 STAN DARD
Unit Cost
$L22.46
$48.73
$24.37
Sq Ft
Sq Ft
Sq Ft
VB
VB
VB
Page 5 of 5
VALUATION I]{FORMATIOI{
SPRINGTIELD
,&
Transaction Receipt
B',,1-19-002485-DWL
IVR Number: 81 1039699021
Receipt Number: 473139
Receipt Date:11127119
City of Springfield
Development and Public Works
225 Fifth Street
Springfield, OR 97477
54t-726-3753
permitcenter@springfield-or. govOREGON
www.springlield-or. gov
Worksite address: 4230 HORACE ST, Springfield, OR 97478
Parcel: 1 802052406301
Payment Method: Check number: 31827 Payer: BRUCE WIECHERT
CUSTOM HOMES INC
Payment Amounl:
Amount not applied to fees
$12,564.09
$12,564.09
Cashier: Katrina Anderson Receipt Total:$12,564.09
Printed: 1 l/27119 9118 am Page 1 of 1 Fl N_Transactron Receipt_pr
SPRIi{GFIELD
,#
OREGON
www.springfield-or gov
Worksite address: 4230 HORACE ST, Springfield, OR 97478
Parcel: 1802052406301
Transaction Receipt
811-19-002485-DWL
IVR Number: 81 1039699021
Receipt Number: 473140
Receipt Date:11127119
City of Springfield
Development and Public Works
225 Fifth Street
Springfield, OR 97477
541-726-3753
permitcenter@springfield-or.9ov
Transaction Units
date
11127 t19 1.00 Ea
11127119 2,158.00 SqFt
11t27t19
11t27 t19 135.93 Amount
11t27t19
11t27 t19 22.82 Amount
11t27 t19 190.09 Amount
't1t27t19 89.48 Amount
11127119 1.00 Aty
11127 t19 100Ea
11127t19 1.00 Ea
Description
Structural building permit fee
Residential wiring
SDC: Compliance Cost - MWMC
Regional Wastewater SDC
SDC: Administrative Fee - MWMC
Regional Wastewater SDC
SDC: Total Transportation
Administration Fee
SDC: Total MWMC Administration Fee
- Local
Curb cut fee - enter # of cuts
Curb cut and Sidewalk construction -
multiple permit discount
Sidewalk construction - permit, first 90
linear feet
Fees Paid
Account code
224 -00000-425602- 1 030
224 -00000 -4261 02- 1 033
434-00000-448027-8800
433-00000-448024-88 1 0
433-00000-448025-88 I 0
433-00000-426607-88 1 0
7 1 9-00000-426604-8800
7 1 9-00000-426604-8800
201 -00000-428060-1 069
201 -00000-428060-1 069
201 -00000-428060-1 069
3,611.72 Amoun SDC: lmprovement - Transportation
SDC
Fee amount
$1,691 56
$294 00
$3,61'l .72
$135,93
$1,620,85
$10 00
$85.31
$330.84
$190.09
$89 48
$ 12s.00
$(42.00)
Paid amount
$1,691.56
$294 00
$794 19
$135.93
$1,620 85
822.82
$10.00
$85.31
$330 84
$190 09
$89 48
$125 00
$(42.00)
$1 25 00
SDC: Reimbursement Cost - MWMC
Regional Wastewater SDC
1,620.85 Amoun SDC: lmprovement Cost - MWMC
Regional Wastewater SDC
11127 t19 10.00 Amount 61 I -00000-426604-8800
11t27t',tg 85.31 Amount SDC: Total Storm Administration Fee 719-00000-426604-8800
11t27 t19 330.84 Amount SDC: Total Sewer Administration Fee 719-00000-426604-8800
Printed: l1l27l19 9 19am Page 1 of 2
$125.00
Fl N_Tra nsactionReceipt_pr
$22.82
Transaction Receipt
811-'t 9-002485-DWL
Receipt number: 473140
Transaction Units
date
11127119 1.00 Ea
Description
Address assignment - each new or
change requested externally, per each
Wllamalane fees - Single Family
Detached, per unit
Fees Paid
Account code
11t27 t19 1.00 Automatic Technology Fee
11127t19 1.00 Qty
224 -00000 - 425602-0000
20 4 -00000 - 425605-0000
82 1 -00000-2 1 5023-0000
Fee amount
$54.00
$ 167.93
$3,805.00
Paid amount
$54 00
$167 93
$3,805 00
Payment Method: Credit card
authorization. 02329d
Payer: BRUCE WIECHERT
CUSTOM HOMES INC
Payment Amount:$9,500 00
Cashier Katrina Anderson Receipt Total:$9,500,00
Printed: 1 1/27119 9:'l 9 am Page 2 oI 2 Fl N_Tra nsaction Receipt_pr
ClTy or Spnn tcFIELD,roREGoN
Structural Permit Application
Savno &S Ll t-tt H o "o.-fi
otLlr-
i;ffi Oru1
225 Fifth Sfreet 0 Springfield,ORg7477 .PH(541)726-1753 . FAX(541 )726-3689
This permit is issued under OAR 918-460-0030. Permits expire if work is not started within 180 days of
suspended for 180 days.
or if work is
o\-
o
DEPARTMENT USE ONLY
permirno.: 11- OOaUe5-
Date: \ \'{rg
LOCAL GOVERNMENT APPROVAL
This project has final land-use approval.
Signaturet Date:
This project has DEQ approval.
Signature:Date:
ENoZoning approval verified: E Yes
Property is within flood plain: I Yes E No
CATEGORY OF CONSTRUCTION
tResidential I Government I Commercial
JOB SITE INFORMATION AND LOCATION
Job site address:fS.cC-L
city: Jgf r]state:0 fv ZIP:
Cr,Subdivision:Lotno.: I
Reference:Taxlot:
PROPERW OWNER
llame: ?rW C tl
Address:a-)o 3
cry, C,:le.^1-State:o 4,,ZtP:fl je
ptrone,sYft ob S-of O Fax:
4s t.> v e?E-mail:t +
Building Owner or Owner's agent authorizing this application
Sign here:
! This installation is being madc on residential or farm property owned
by me or a member of my immediate family, and is exenrpt from
licensing requirenrcnts under ORS 701.010.
CONTRACTOR INSTALLATION
Business name: f,\1 J(
Address:
City:Statc:ZTP:
Phone:Fax:
E-mail:
CCB license no.:0l ()
Print name:lewtCtt-S
Sisnaturc: CrU hn-'
FEE SCHEDULE
1. Veluation informrtion
(a) Job description:
Occupancy
Construction q4pe:,
Square feet \
Cost per square foot:
Other information:
Type of Heat:
EnergrPath: Z A
I new flalteration ! addition
(b) Foundation-only pcrmit? fl Yes E No
Total valuation:$
2. Building fees
(a) Perrnit fee (use valuation table):$
(b) Investigative fee (equal to [2a]):$
(c) Reinspection ($ per hour):
(number of hours x fee per hour)$
(d) Enter 12% surcharge (.12 x [2a+2b+2c]):$
(e) Subtotal of fees above (2a through 2d):$
3. Plan revierv fees
(a)Planreview@ s338.oi
(b) Fire and lifdzsafety (65% x permit fee [2a]):$
(c) Subtotal of fees above (3a and 3b):$
4. Miscellaneous fees
(a) Seismic fee, lo/o (.01 x permit fee [2a]):$
O) Tech fee,5oh (.05 x permit fee[2a]+PR fee [3c])$
[OTAL fees and surcharges (2e+3c+4a+b):$
SUB.CONTRACTOR INFORMATION
Name CCB License #Phone
ElectricalL+€tot17{
Plumbing
Ov" Cosh-r'.01u*b,,\ Rll4
Mcchrnlcel I
Corn&zt (b'n luo
Last cdired 5-5-201 9 BJones
404Cq^^^t-
13"
CITY OF SPRIN{GFIELD, OREGON
Electrical Permit tion tPtnaofrll-0
225 fifth Strssttspringtleld, OR g4n aPE;lS/.!)T 26-37 S3oFAX(54r)26'3689
This permit is issued under OAR 9r&309-0000. permits are nontransferable. Permits erpirc if work is not started within 1E0
days ofissuance or ilwork is suspended for 180 days.
L
LOCAL APPROVAL
Zamng approval verifi ed?flYes ENo
GATEGORY OF CONSTRUCTIONvResidentialE Government E Commercial--JoB strE tNFoRMATtoN AND LocATloN
Job site address:
ctty,flntJ..Jv ;-!-)State:zw..
t"r;"? rv Taxlot:Ob3 O I
OF WORK
PROPERTY OWNER
Narne: i). f ^'lf -
Address:
CiU:State:ZIP:
Phone:
E-mail:
This installation is being made on residential or farmproperty
owned by me or a member of my immediate family. This
property-is not intended for sale, exchange, lease, or rent. OAR
479.540(1) and 479.560(l).
Signature:
INSTALLATION
Business name:
Address:() {\€-S
crg: 6OCtA State:O1--<aP:a-1H-?8
puoneSl{i- 5zt -Yrq e)ro54[-533 -a5"tE
E-mail:r (z-k t dc vrauden o,
CCB license no.: \ D6 ui-I 6 BCD license no.: ZO - 39,:
Signrqgsupervisor'slicenseno.: L{ lYt-{- 5
Print name of rypgrvtsor EA De-n Ou&eo
ofsigning supcrvisor:
FEE SCHEDULE
Number oflnspcctions Pcr item ( )Qty-Cost
Ge.
Total
cost
Residential, per unit, service included:
1,ffi0 sq. ft. or less (4)$1E6.00 $
Each additional 500 sq. ft. or portion
tbereof s36.00 $
Limited energy (2)$44.00
Each manufactured home or modular
dwelling service or feeder (2)$E9.00 $
Scrvices or feedersz installation, ahemtion, relocation
200 amps or less (2)$1r2.00 $
201 to 4O0 amps (2)$131.00 $
401 to 600 stps (2)$221.00 $
601 to 1,000 amps (2)$2E5.00 $
Over I,O00 amps orvolts (2)$654.00 s
Recoonect only (2)$E9.00 $
Temporary scrvices or feedcrs: hstallation, alteratioq relocation
200 amps or less (2)$89.00 $
201 to 400 amps (2)$122.00 $
401 to 600 arrtps (2)$r77.00 $
Over 600 mps or 1,000 volts, see services or feeden section above
Branch clrculb: new, alteration, actension W Wnel
a Fee for brarch circuits with purchase ofa service or feeder fee:
Each branch circuit $E.00 $
b. Fee for branc.h circuits without purchase ofa service or feeder fee:
First branch circuit @)$89.00 $
Each additional branch circuit $8.00 $
Misccllaucous fees: semice or/eeder not included
Each pump or irrigation circle (2)$19.00 $
Each sign or outline lighting (2)$89.00 $
Signal circuit or a limited-energy panel,
alteration, or extension (2)$E9.00 $
Erch addltional lnspccdon: (l)$r02.00 $
DEPARTMENT USE
(A) Entersubtotal ofabove fees
(Minimum Permlt Fec $102.fl))$
@) Enter l2%o surcharge (. t2 x [A])$
(C) Techoolog5r Fee (5% of[A])$
TOTAL fees and surcharges (A through D):$
DEPARTMENT USE ONLY
Permit no.: \9 -gfe q 9S-[
Date: It I glz+t1
Lost editcd 7 lll20l9 B,Jote
Fax:
CONTR
l\v. {-cr r
tAr>1, iierur
$
SPRINGFIELD
OREGON
www. springfl eld-or. gov
Worksite address: 4230 HORACE ST, Springfield, OR 97478
Parcel: 1802052406301
Transaction Receipt
81 I -19-002485-DWL
Receipt Number: 472911
Receipt Date: 11/6/19
b
City of Springfleld
Development and Public Works
225 Fifth Street
Springfield, OR97477
54t-726-3753
permitcenter@spri ngfi eld-or. gov
Fees Paid
Transaction date
11t6t19
Units
1.00 Ea
Description
Master plan review - second and subsequent
reviews
Account code
224-00000425602-1030
Fee amount
$338.00
Paid amount
$338.00
Payment Method:Credit card authorization:
03108d
Payer: BRUCE WECHERT CUSTOM HO Payment Amount:$338.00
Cashier: Katrina Anderson Receipt Total:$338.00
Printed: 1 1/6/19 12:08 pm Page 1 of 1 Fl N_TransactionReceipt_pr
lr -r-
JOURNAL ORJOB NUMBER:
NAME OR COMPANY:
I,OCATION:
TAX I-OTNUMBER:
DEVET,OPMENT TYPE:
NEW DWELUNG UNITS
IMPERVIOUS AREA
DIRECT RUNOFF TO CITY STORM SYSTEM
A. REIMBURSEMENT COST
IMPERVIOUS S.F.
2312.00
B. IMPROVEMENT COST
IMPERVIOUS S.F.
2312.00
ITEM I TOTAL - STORM DRAINAGE SDC
2. SANITARY SEWER- CITY
A. REIMBURSEMENT COST:
NUMBER OFDFLIs
26
B. IMPROVEMENT COST:
NUMBER OF DRJ's
26
COST PER S.F.
s0.301
COST PER S.F.
$0.437
COST PER DFU
$170.50
COST PER DFU
s83.99
NUMBER OFUNITS
I
NUMBER OF UNITS
I
COST PER FEU
$ l 35.93
COST PER FEU
$ 1,620.85
ADM. FEE RATE
5%
AREA DRAINING TO
DRYWELL
0
0
s1,706.26
$6,616.74
COST PER TRIP
19.86
COST PER TRIP
s377.40
s1,789.60
$13,914.38
CTIARGE
9695.72
CHARGE
$695.91
CIIARGE
$'l,010.34
NEW TRIP FACTOR
1.00
NEW TRIPFACTOR
1.00
CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT WORKSHEET
l9-002485-DWL
BRUCE WEICTIERT CUSTOM HOMES
4230 HORACE ST
Residence
x
ITEM 2 TOTAL. CITY SANITARY SEWER SDC
3. TRANSPORTATION
A. REIMBURSEMENT COST:
ADT TRIP RATE
x
x
x
xx
B. IMPROVEMENT COST:
ADT TRIP RATE
9.57
xx
ITEM 3 TOTAL - TRANSPORTATTON SDC
4. SANITARY SEWER. MWMC
A. REIMBURSEMENT COST:
NUMBER OF FEU'S
I
B. IMPROVEMENT COST:
x
x
xNUMBEROFFEU's
I
C. COMPUANCE COST:
NUMBER OF FEU's
I
MWMC CREDIT IFAPPUCABLE (SEE
MWMC ADMIMSTRATIVE FEE
ITEM 4 TOTAL. MWMC SANITARY SEWER SDC
SUBTOTAL (ADD ITEMS I,2,3, & 4)
x
TOTAL STORM ADMINISTRATION FEE
TOTAL SEWER ADMINISTRATION FEE:
TOTAL TRANSPORTATION ADMINISTRATION FEE:
TOTAL MWMC ADMINISTRATION FEE - I,OCAL
SlZE SZEI
MAX
$695.91
s135.93
$22.82
$89.48
$14,5r0.r0
l09l
1092
1093
1094
1054
1055
l 054
I 056
079
077
078
aql
oO
&rjlFa
E)
COST PER FEU
$22.82
SUBTOTAL
PREPARED BY Steven Petersen DATE ty25/20r9
TOTAL SDC CHARGES
x
x
ri 13.914.3 8
l.7E
DRAINAGE FIXTURE UNIT CALCULATION TABLE
NUMBER OFNEW FIXTURES x LINIT EQUIVALENT: DRAINAGE FXTURE UNITS
FOR CAI-CUI.{TE ONLY THE NET ADDITIONAL
NO. OF FIXTURES
UNIT
FIXTURE TYPE NEW OLD
MISCELLANEOUS DFU TYPE NUMBEROF EDU'S
TOTAL DRAINAGE FIXTURE UNITS
lsa toa unit set at 167
MWMC CREDIT CALCULATION TABLE: BASED ON COUNTY ASSESSED VALUE
20
DRATNAGE
FIXruRE
UNITS
0
2
1979
*EDU
$5.29
$5.1 I
$5.1 2
$4.98
$4.80
$4.63
$4.40
$4.07
$3.67
$3.22
$2.73
$2.25
$1.80
IS LAND ELGIBLE FORANNEXATION CREDIP
(Enter 1 for Yes, 2 for No)
IS IMPROVEMENT ELGIBLE FOR ANNEX. CREDIT?
(Enter 1 for Yes, 2 for No)
BASE YEAR
CREDIT FOR LAND (IF APPLICABLE)
2
VALUE / 1OOO
$0.00
CREDIT RATE
$s.29x
CREDIT FOR IMPROVEMENT (IF AFTER ANNEXATION)
VALUE / 1OOO CREDIT RATE
$0.00 x $5.29
TOTAL MWMC CREDIT$1.s9
$1.45
$1.25
$1.09
$0.e2
$0.72
$0.48
$0.28
$0.09
$0.05
BATHTUB 3103
DRINKING FOUNTAIN 0 0 1 0
FLOOR DRAIN 0 0 3 0
INTERCEPTORS FOR GREASE / OIL / SOLIDS / ETC 0 0 3 0
INTERCEPTORS FOR SAND / AUTO WASH / ETC 0 0 6 0
LATINDRY TUB 0 0 2 0
CLOTHESWASHER / MOP SINK 1 0 3 3
CLoTHESWASHER - 3 OR MORE (EA)0 0 6 0
MOBILE HOME PARK TRAP (1 PER TRAILER)0 0 12 0
RECEPTOR FOR REFRIG / WATER STATION / ETC.0 0 1 0
RECEPTOR FOR COM. SINK / DISHWASHER / ETC.1 0 3 3
SHOWER, SINGLE STALL 1 0 2 2
SHOWER, GANG (NUMBER OF HEADS)0 0 2 0
SINK: COMMERCIAL/RESIDENTIAL KITCHEN 1 0 3 3
SINK: COMMERCIAL BAR 0 0 2 0
SINK: WASH BASIN/DOUBLE LAVATORY 0 0 2 0
SINK: SINGLE LAVATORY/RESIDENTIAL BAR 3 0 1 3
URINAL, STALL/WALL 0 0 5 0
TOILET, PUBLIC INSTALLATION 0 0 6 0
TOILET. PRIVATE INSTALLATION 3 0 3 I
26
YEAR
ANNEXED
CR-EDIT 1,000
ASSESSED VALUE
BEFORE 1979
1979
1980
1981
1982
I 983
I 984
1985
r986
1987
I 988
1989
I 990
l99l
1992 00
1993
1994
1995
t996
1997
1998
1999
2000
2001
Aept-nactLl- E NtE frc-'< t4 g*<crF=g g
ENEBGY EFFICIENCY
rABLE NI101.1(2)
ADDITIONAL MEASUHES
Por SI: I square foot = 0.093 m2, 1 watt per square foot = 1 0,8 \Wmz,
a' Appliances located within the building thermal envelope shall have seaied combustion air installed. Corabustion air shall be ducted directly from the
outdoo$.
b. All ductjoints and searns sealed wi0r listed mastic; tapo is oDIy allowcd at appliance or equipment conuections (for service and replacement). Mect sealing
criteria oiPerformalce Tesled Comfort Systenn program adnrinistered by the Boaneville Po*erAdminislratioa @PA).
o. Resideotial water henters l6ss tban 55 gallon storago volume.
d' A totalof 5 perccnr of an }IVAC systern's ductwork shall be permitted to be tocated outside of the conditioneil spaca Ducts localed oulside the conditioued
space shall havo insulation iostalled as required in this eode.
e, Tfiemaximumvaultedceilingsurfaceareashallnotbegreaterthan50percentofthelotatiealedspacefloorareaunlcssvaultedareahasaU-faclornogreater
than U-0.026.
f. Continuous air barrier. Additional reqrirement for sealing of all interior yertical wall covering to top plate framing. Sealing rvith foam gaskeL caulk or other
approved sealant listed forsealing wall covering material to structursl nlatedal (example: gypium Uoard to wood sfud framing)
g. Tabie Nl104' l(1) Standard base caso design, Code UA shall bc at least 8 percent less than the Proposed UA, Buildings with fenestration lcss than 15 pelcent
oftlte total verlical wallarea rnay adjust lhe Code UA to trave 15 percent ofthe wall ar€a as fenestiation.
Hlgh errlciency r,rallsi
Brterior walls-U-0.045/R-21 cavity insulation + R-5 coltinuous
Upgraded features
@ Exterior walls-U-0.0571R-23 intermediate or R-2 I advanced,
Fraured fl oors-U-0.026,rR-38, and
\Yindows-U-0.28 (averagc UA)
Upgraded fealures
3 Exterior rvalls-U-0.0551It-23 intermediate or R-2 t advanced,
Flat ceilinge-U-0.0171R-60, aad
Framed {Ioors-U-0.026/R-38
Super lnsulsled Windolvs and Attic OR Frarned Floors
4 Windorvs-U.0.22 flriple Pane Low-e), and
FIat ceiling'-U-o.017/R-60 or
Fram ed fl oors-U-0, 026/It-3 I
Air sealing home and ducts
5 or ASHRAE 62.2, and
and
High olllclency lhermal onvelope UAs
o
EoocG
u
ooIo
Eut
oco
6
6 Gas-fired furnaee or boiler AFUB 947o, or
Air source heat punrp HSPF 9,5/I5.0 SEER cooling, or
Ground source heat pump COP 3,5 or Encrgy Slar iated
High efflclency HVAC systema
B All ducts ald air handlers cortained wl&in building
Comotbe conbitud with lteasure 5
Ducted HyAC systems yrllhln condllloned space
Ductless hoat pump
C
Ducdess hcat.pump HSPF I0.0 in primary zone of dwclhing
High elfi.lency !,rater
o
o(!oE
D Natural
Electric
gas/propane water heater rvith
hentpump rvater lreaterTiet 1
rrEF0.85 0R
Northern Climate Specifi calion Product
2017 OBEGON HESIDENTIAL SFECIALTY CODE 435
andat
AII ducts and air haudlers
All ducts soalcd with
Proposed UA is 89o lower lhan the code UA
I
1 120 Arthur Street
Eugene, Oregon97402
Office: 541-357'5532
Cell:541-556-1248
Ammon@WoodChuckEngineering.com
November 6,ZOtg Proiect:19.298
Bruce Wiechert
3073 Skyview Lane
Eugene, Oregon 97405
Subject: Engineering calculations
Bridlewood Plan
Eugene, Oregon
PROJECT DESCRIPTION
This project consists of analyzing the foundation, framing and lateral bracing systems for the proposed
single-family residence at the subject location.
DESIGN CALCULATIONS
Descriptioq Pages
Shearwall plans
Design criteria and seismic response
Lateral load calculations
Framing and foundation analysis
Connections
DESIGN CRITERIA
RoofDead Load = 15 psf Floor Dead Load = 12 psf
Roof Live Load = 25 psf [Snow) Floor Live Load = 40 psf
Vurt,120-mph [3-second gust) I": 1.0
Site Class: D [default) Soil Bearing: 1500-psf
Seismic Category: D S,: 0.702
Sr: 0.40L Sos: 0.58
ASCE 7-16, 2014 OSSC fbased on 2012 IBC)
Thank you for the opportunity to be of service. Please call if you have any questior:s.
Respectfully,
1.-2
3-7
B-14
L5-41.
42
aC-"","-/-r4 NE
Ammon Luke, E.l.T.
WoodChuck Engineering /*t\-/
65+76PE'
11
by Chuck
l:14:51
oi Fault
{8',0G ^
(
)ires: 't 2-31-19
C
t'
,;
Y6a
('t
c,N{ol
(,o -a)or
Fc{ i^
@
io
c{(o
t)(o
"?ts0
io6
e
NI
lr,
q
F.!l"
io!.
-6
.irt
in
,?
F(r)
k)(e
q(\(>
6bg3
oslOFEc{
gR
;irl
*ruiAr6-€ ag8o- 5c);^
r: ^=- d n-
6 O q= F
---EobheSga-3:;69o X-E --- trt!"!2i'ii!-'o:#DO(o=Otlo [)-o--^ l-6iJ=E-ib
E E B**o g^-o -.o. *ooaJ&1,S S &.*^ai
s s-5 EB
r?pT iqo i'€
^^-II
^-^.^,
o^---J t
o@o!
E E T*58Eno:=OE:ETEEhL'&o:x
oqoiP gG coooi
Eoo.!u () > al
a;t,3.I
irl Io b io i., in b irr k ir, b io in k, b e ;o b b io A'rr b io'n b b io ir'V I Y * A; I E * ii ;i ;( ; ; ; ;'r - N - ^; i' a T ^i r r ry r. $uiri'ib.rc.iT:ry
zSdp *t60! 1,'601 -'18:0et
btg
e^00
t-E
e
o
@
ZI
U)
UJo(foo
E
V,o
TL
ula
3F
l.r.o0
:()
a
p,
!Qo
?
t0
c)o
q
I
GIt-
Go
a
@v,.x
o3?oo3
ai'-(o
I
(o
F
I*
f.-(o
"sbIv
lf
i.*(o
I
I
Gtoo-c
Q
@ox
o3
13oo3
eF,
tlc :r'i:,
-..|i
!
oO
o
,gE
c
{J
O
u
u
N
$
6f\
\32
E.
O
f,
- 0'0
i
t-
i0tN
:b
l!F
Gg(ooo
Lrtt,
o
O,a
1/ 42
rt
^-(o
t
t-t. :'
t"-
fiI
ax,o
Ol
(tN{N
-)oo
b b ir,-
^i qI FCdN.\Ir,t..,tb/)6$:oO !a
.l 5J.+rl:oPff-q
F-
an
io
ft)
a$t
(f,
bc,
a?
N(\
^iog:
€, ra,
o(\lgNo:
6N.g ioI r.-oFt-@S
^a -
= of ;^CL.oO'i;^=: Sr! (4 s= -Oll-tro-iEo;
3 tr-d g g
o y-E+?
Ea;.'#*:t+t(l o ^o^-- ,x
EOL;.Jooo:;!.h-F;sOooO-
'E .s .C F/o
s siPE,
^l^
-
a-v ','-{\l9r<3 &d,'r g
^it-^^^?
6
.3 3^ ^^ ^t
--.o--Fg.9EE"0s6:;sisE-
=oX=o
S E: E.(49.Qfivv'L6=A
EEU*Eooaoxo o cE @oeoo.!LLr,r()>O
q
.15loqI ..I_Y
b$
t,f,fr
{
{
,;
{
i, ir)T?
i
e{"{5
:4
-sbcna_i.r
NNN,N
io io b in k, irl b iro io io b io io k b io inrfNrf;oGiotsNGiNFniF
tt6O({Cd
6
t
zi,a
IIJo
(f,o
3
x.o
lJ-
ui
3FIl.oq
Nv
Iq
ao
(f)
oo(')
iq
Ntt
[6e Z,'EZL Z (,8'
I 19 -,.68t r 68t ,8 ,9t
-tffitoor *rz\f ri *s!ml
8?gt *zzB
lr,vlr)
I
g
c
6o
o
@9'
o
3!o(,e
{r
9,
a[i
(E
$-ca
@v,l(
o3!,oo3
-0862
!a0 c{
:El!N
9;(ooOJ
.o
.)
t
,..: '
L-y
t.- I
'l'
2/42
l,
4
lL
ASCE ASCE 7 Hazards Report
Address:
Eugene
Oregon,
Wind
Standard; ASCE/SEI 7-16
Risk Category: ll
Soil Class; D - Default (see
Section 11.4.3)
Elevation= 427.44 ft (NAVD 88)
Latitude: 44.04992
Longitude: -123.08854
| 1,
Results:
Wind Speed:
1O-year MRt
25-year MRI
SO-year MRI
'1OO-year MRI
Data Source:
Date Accessed:
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure c category, baserl on tinear -interpolation between, contours. wind speeds are interpoirt"i in u."ordance with the 7- t6 siandaro vViricj speeds-correspond to approximately a 7o/" probability of exceedance in 50 years (annual exceeoance probability-= - -0.00143, MRI = 700 yearS). veqr o \qr rr rudr e^uee
-
site is not in a hurricane-prone region as defined in ASCEisEI 7-16 sectio n 26.2.
Mountainous terrain, gorges, ocean promontories, and special wind regions should be examined for unusual windconditions.
96 Vmph
66 Vmph
72Ymph
76 Vmph .
81 Vmph
ASCE/SEI 7-16, Fig. 26.s-18 and Figs. CC.2-1_CC.2,4
Thu Oct 242019 ' .
httos ://asceThazardtool.online/Page 1 of 3 Thu Oct 24 2019
3/42
i*
I
I
.. r,
e.-
'l'.trr
.l
-tb:
Lr:ii'trl
'rl r
r*vi*
"a-
AMERICAI,I SOCIEIY OF CII'IL E!\GINEEES
Seismic
Site SoilClass:
Results:
D - Default (see Section 11.4.3)
Ss : 0.702 So, : N/A
Sr : 0.401 Tr : 16
F" : 1.238 PGA : 0.334
Fu r N/A PGA Nr : 0.423
Sus : 0.87 Fpae : 1.266
Snr, : N/A l" : 1
Sos : 0.58 C, i 1.151
Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 1 1 .4.8.
Data Accessed: Thu Oct 242019
Date Source: USGS Seismic Design Maps
:
https://asceThazardtool.online/
Page 2 ol 3 Thu Oct 24 2019
4/42
WoodWorks@ Shearwalls SOFTWARE FOR WOOD DESIGN
WoodWorks@ Shearwalls 1 1.1
06 final.wsw Oct. 24, 2019 08:46:25
Project lnformation
COMPANY AND PROJECT INFORMATION
DESIGN SETTINGS
ITE TION
1
Comoanv Proiect
Woodchuck Engineering
1120 Arthur St
Eugene, Oregon
Bruce Wiechert
Bridlewood Plan
10 ?oQ
A NT,
Design Code
IBC 2015/AWC SDPWS 2015
Wind Standard
ASCE 7-10 Directional (A1I heights)
Seismic Standard
ASCE 7_10
Load Combinations
For Design (ASD) For Deflection (Strength)
0.70 Seismic + 0.60 Dead 1.0C Seismlc + 0.90 Dead
0.60 Wlnd + 0.60 Dead 1.00 Wind + 0. 90 Dead
Building Code Capacity Modification
Wind Seismic
1.40 1.00
Service Conditions and Load Duration
Temperature Moisture Content
Range Fabrication Service
T<=100E <-Ig,; <=19;
Duration
Factor
1. 60
Max Shearwall Offset [ft]Plan Elevation
(within story) (between stories)
4.00 4.00
Maximum Height-to-width Ratio
Fiberboard Lumber
Wind Seismic Blocked Unblocked
Gypsum
5
Wind
]E
Wood panels
Seismic
lgnore non-wood-panel shear resistance contribution..
Wind Seismic
Never Always
Collector forces based on...
Hold-downs
Drag struts
Applred loads
Applied loads
Shearwall Relative itidWaff c
3-5uation 4Perforated shearwall Co factor:SDPWS E
t for material te e
nNo cal-identi lsmateria construand onction sheathe rl lne:At-.Iowe d
Deflection Equation 4-term from SDPWS C4.3,2-2
he j-ghtDrift limit fo rwind design: 1 / 500 stor
Wind
ASCE 7-10 Directronal ts)(Al1 hei
Design Wind Speed
Serviceability Wind Speed
Exposure
Enclosure
Min Wind Loads: Walts
120 mph
1-00 mph
Exposure B
Enc-Iosed
16 psf
Risk Category
Structure Type
Building System
Design Category
Site Class
Categoiy II - AII others
Regu Ia y -
Bearing Wall
D ^--- , _^-.-^
D.
:orce Procedu:e
Spectral Response Acceleration
Ses-mic_ -
rvalent Later.af
51:0.40
ASCE 7-10 12.8
- Ss: o- 7(,
Topographic lnformation [ft]
Height Length
n:-
Shape
S
Fundamental Period
T Used
Approximate Ta
Maximum T
E.W
0.215s
0.215s
0. 30ls
Elev: Oft Avg Air
Rigid bulldin
0765 1b,zcu ft
analys isStati c
density:0
Factor R 6.50 6.50Res
Case 2
Eccentricity (%)
Loaded at
E-W loads
15
15 t
N-S loads
15
Fai 1.24 Fv: 1. 60
s/42
N-S-----
0.21-5-s- -
0.215s
0.301s
WoodWorks@ Shearwalls 06 final.wsw Oct.24,2019 08:46;25.-
Structural Data
INFORMATION
2
Elev lftl
Story Wall
Heiqht Iftl
Floor/Ceiling
Deoth linl
Ceiling
Level 2
Level 1
Foundation
0
l2
72
0
0
0
11.00
1. 00
0. 00
9
9
00
00
20.00
Roof PanelsBlock
Block 1
Location X,Y =
Extent X,Y =
Ridge Y Location, Offset
St
0
29
l4
00
33
25
0.00
28.50
0.00
E-W Rldgeory
North
South
East
Side
Side
cable
33.1
11 1
90.0
2
2
2
00
00
00
Block 2
Location X,Y =
Extent X,Y =
Ridge Y Location, Offset
29.33
22 .00
11.00
E-w Ridge
0.00
22.00
0.00
1 Story
North
South
East
Side
Side
Gable
18.4
18.4
90. O
2
2
2
00
00
00
Block 4
Location X,Y =
Extent X,Y =
Ridge X Location, Offset
8.33
2t.a0
18.83
N-S Ridge
-3.66
3 .66
0.00
2 Story
North
South
East
Joined
Gabfe
Side
746.3
90.0
2
2
2
00
00
00
Block 5
Location X,Y =
Extent X,Y =
Ridge X Location, Offset
12.00
,? ??
N-S Ridge
28. s0
8.00
0.00
1 Story
North
South
East
Gable
Gabfe
Side
2
0
2
00
00
00
0
90.0
33.7
90
Block 6
Location X,Y =
Extent X,Y =
Ridge X Location, Offset
-2.00
2.00
0.00
15.50
s.00
1.00
1 Story N-S Ridge
North
South
East
Gabfe
Gable
Side
90.0
90.0
90.0
0
0
0
00
00
00
Block 7
Location X,Y =
Extent X,Y =
E-W Ridge
-8.66
5.00
2 .50
1 Story
E
Ridge Y Location, Offset
o 21
2L.00
-3 .66
North
South
East
Side
Side
Gable
90. 0
18.4
90.0
0.00
2 .00
2.0i' - - -
6/42
WoodWorks@ Shearwalls 06 final.wsw Oct.24, 2019 0E:46:25
Level Mass Story Shear flbsl Diaphragm Force Fpx [bs]
2
,|
Alt
3251 I
51 L34
49712
912.8
1406.8
4153
3833
7 987
4153
3833
7 987
4153
66t2
4153
66t2
Flexible Diaphragm Seismic Design
Legend:
1
on ly for drag struf forces, see
Redundancy Factor p (rho):
E-W t.00, N_S 1.OO
Automatically calculated according to ASCE 7 12.3.4.2.
Vertical Earthquake Load Evtv=02sdsD; Sds=058; Ev=0116Dunfactored; 0081 Dfactored; totar deadroadfactor: 0.6-o.og1 =0.51gtension, 1.0+9.961 =1.0g.1
compression.
24 7 /42
Area
lso-ftl
(l
Materials
Bridlewood Plan
Eugene, Oregon
MATERIALS WALL
Legend:
Grp - Wall Design Group number, used to reference wall in other tables
Ratng - Spon rating, see SDPWS Table C4.2.2.2C
Ply - Number of plies (or layers) in construction of plywood shee*
Or - Orientation of longer dimension of sheothing panels
Type - Fastener type from SDPWS Tables 4.3A-D: Nail - common wire nail lor structurol panels ond lumber.
See SDPWS Table A1 - 8d common nail L = 2-1/2", Dio. = 0.131", H = .281"
70d common nail L = 3", Dio. = 0.148", H = .312"
Size - Common, box, and casing nails: refer to SDPWS Table 41 (casing sizes = box sizes).
Blkg - Sheathing is nailed to blocking at oll panel edges; Y(es) or N(o)
Wall Type - Perforated (Perfl, Segmented (Seg)
Notes:
3 - Shear capacity for current design has been increased to the volue for 15/32" sheathing with same nailing becquse stud spacing is 16,' max or ponel orientation is
horizontal. See SDPWS 74.3A Note 2 and IBC 72305.3 Note d.
SCHEDULE
Surface
Sheathing
I
natins
I '1;'- I orMaterial :1 rvpe
I 'lf" | 'llo | ''u'
Fasteners Apply
Notes
Wall
Type
f-bolt spacing 16d common nail sill plate
nailing Iin.)
1 Ext Struct Sh OSB 24/76 7 /t6 Vert Bd Nail 6 72 Y 3 Perf 7/2" Dia.x48" o.c.1Z
lcroup\
\Name/Holdown Anchor End
Stud
A HDU2 SSTBl 6 (Z) 2x6
B HDU4 SSTB2O (Z) 2x6
C cs16 20-10d 2x6
D MST37 2Z-16d (2) 2x6
E HTS24 20-1 0d (2)zx6
F (2) HTS24 20-1.0d (2) 2x6
@
FN
Client: Bruce Wiechert
Project: 19.298 WoodChuck Engineering 10 /25 /2019
f{#+rBFHJ J,FJJ JWoodChuck
Eno-if,Efirtr-a
v
#-mr ,rylt J
I"gg9-c.h.u'""\
Wind Shear Results
Bridlewood Plan
Eugene, Cregon
Legend:
IJnless otherwise noted, the value in the tablefor q sheorline is the one for wall on the line with the critical design response.
Wall group.
For Dir - Direction ofwind force along shearline.
V - ASD loctored shear force. For shearline: total sheorlineforce. For wall: force taken by total oJall segments on walL
vmax - Base shear = ASD foctored sheor force per unit full height sheathing, divided by perforation factor Co as per SDPWS eqn 4,3-B = V/FHS/Co
v - Design shear force = ASD foctored shiqr force per unit t'ull height sheqthing, For wall, it is the largest force on any segment.
Co - PerJordtion focLor from SDPWS Table 4.3.3.5.
C-sheathingcombinotionrule,A=Addcdpacities,S=Strongestsideonly,X=Strongestsideortwiceweakest.
Total-CombinedinLandext.unitshearcqpacityinc.perJorotionJoctor.
-^- --
V-Forwall:Sumofcombinedshearcapacitiesforollsegmentsonwall.Forshearline:sumofallwallcapdcitiesonline. - ---- -
Crit Resp - Critical response = v/Totql = design sheqr force/unit shear capacityfor critical segment on wall or shearline.
"5" indicates thot the seismic design criterion was critical in selecting wall. - - .
Refer to Elevation View diagrqms for individual level for uplift anchorage force t for perforated wolls given by SDPWS 4.3.6.4.2,4.
Allowable shear volues hove been reduced to 140a/o of published values.
Client: Bruce Wiechert
Project 19.298
North-South
Shearlines \r'For
Dir u lu-*
Shear Force
v flbsl I v/L
lplq
I v/nns
Allowable Shear IplfJtnt I rxt I co I rotut I vttrrl
Crit,
Resp.J-bolt spacing
16d nail
spacing
Wall 1-1
Wall T-2
Wall 1-3
Wall4-2
Wall 4-3
Ln5, Levl
s-> N
N ->S
S.> N
N->S
s->N
N->S
S->N
N.>S
s->N
N->S
s->N
N->S
'149.7
151.5
149.7
151.5
t49.1
151.5
19A.9
203.8
217.8
223.t
53.B
53.9
1,49.7
151.5
149.1
151.5
149.1
151.5
226
23t.5
277.A
223.t
58.1
54.2
23lt
2349
745
754
1193
1212
367 4
37 65
1415
1450
980
980
510
510
510
510
510
510
510
510
510
510
510
510
O.BB
0.88
1
1
0.93
0.93
510
510
510
510
510
510
449
449
510
510
472
472
7899
7499
2548
254A
4077
4077
8247
82A7
3372
3372
8590
8590
0.29
0.3
0.29
0.3
0.29
0.3
0.44
0..15
0.43
0.44
0.11
0.11
1/2" Di,a.x48"
l/2" Dia.xLA"
1/2" Dta.x 4A"
1/2" Dia.x4A"
7/2" Dia.x4A"
l/2" Dia.x 4A"
I /2" Dia. x 4A"
L/2" Dia.x36"
l/2" Dia.x4A"
1/2" Dia.x 4A"
7 /2" Dia. x 4A"
l/2" Dia.x 48"
o.c.
o.c.
o,c,
o.c.
o,c,
o,c,
o.c,
o.c.
o,c,
o,c,
o,c.
o,c,
t2
t2
12
l2
12
1,2
11
9
11
11
12
L2
E-W
Shearlines GD
For
Dir , I u-"*
AsD Shear Force [plfl
v llbsl I vmax I v
Allowable shear [plflt.t I r*t I co I rot"t I vltu.l
Crit.
ResD.I-bolt sDacins
16d nail
sDacins
Wall A-1
WallA-3
Wall A-4
Wallc-1
WallC-2
LnD, Levl
w->E
E->W
W.>E
E->W
W.>E
E->W
Both
W->E
E->W
w->E
E->W
t73.2
t77.2
l7 5.7
L79.8
160.3
L64.1
0
9l
89.6
230
230.t
1',73.2
777.2
203.9
20a.6
244.6
295.3
91
49.6
329.3
329.4
1442
L476
2226
2274
597
0
2002
1972
27 5A
27 59
510
510
510
510
510
510
510
510
510
510
510
1
1
0.85
0.86
0.56
0.55
I
1
I
0.7
0.7
510
510
439
439
243
243
510
510
510
356
356
4245
+245
5563
5553
1019
1019
ttztt
t12tt
4264
4264
0.34
0.35
0.4
0.47
0.57
0.58
0.18
0.18
0.65
0.65
1/2" Dia. x 48" o.c.
1,/2" Di,a.x48" o.c.
l/2" Dia.x 48" o.c.
l/2" Dia.x48" o.c.
1,/2" Di,a.x36" o.c.
l/2" Di,a.x36" o.c.
7/2" Dia.x48" o.c.
L12" Dia.x 48" o.c.
1/2" Dia. x 30" o.c.
1 /2" Dia. x 30" o.c.
72
72
1.1
11
B
B
t2
t2
7
7
North-South
Shearlines GD
For
Dir u | ,-u"
Shear Force
v lbsl I v/L
lplrl
I v/rss
Allowabletntlrxtl co
shear [plflI r"tut I vlu'l
Crit.
Resp.I-bolt sDacine
16d nail
soacing
Lnl,Levz
Ln4,Lev2
S.>N
N->S
S->N
N->S
t2t.6
t21.7
80.5
80.6
121.6
t2t.7
82
42.1.
2344
2347
2351
510
510
510
510
1
1
0.98
0.98
510
510
500
500
9942
9942
14588
14588
o.24
0.24
0.16
0.76
L2
t2
l2
l2
E-W
shearlines GP
For
Dir r I r-u*
ASD Shear Force [plf]
v tlbsl I vmax I v
Allowable shear [plf]rntlrxtl co I r"tut lvlurl
Crit.
ResD.l-bolt spacins
16d nail
sDacing
Wall A-1
WallA-2
WaU A-3
LnD, Lev2
E.>W
W->E
E->W
W.>E
E->W
W->E
E->W
tto.2
172.7
777.5
180.6
140.1
1.42.4
83.5
770.2
772.1
186.3
189.5
t40.7
142.4
92.1
92.t
918
934
622
632
7Al
794
19+9
1950
510
510
510
510
510
510
510
510
7
1
0.95
0.95
I
I
0.91
0.91
510
510
446
446
510
510
462
462
4245
4245
t701,
7707
2447
2441
10746
70746
o.22
0.22
0.37
0.37
o27
o.2a
0.18
0.18
12
72
72
12
12
12
l2
t2
WoodChuck Engineering r0 /2+ /20t9
e /42
1
1.
1
1
1
1
1
1
1
1
1
1
1
1
1
I
1
1
L
1
7
L
1
Seismic Shear Results
Bridlewood Plan
Eugene, Oregon
Legend:
IJnless otherwise noted, the vqlue in the table for a shearline is the one for woll on the line with the criticol design responY.
Wollgroup.
For Dir - Direction ofwindforce along shearline.
V - ASD fdctored shearJorce. For sheorline: total sheqrline force. For woll: force taken by total ofdll segments on wall
vmdx - Base shear = ASD factored shear force per unitfull height sheathing, divided by perforation foctor Co qs per SDPWS eqn. 4.3-B = V/FHS/Co.
v - Design sheor force = ASD foctored shear force per unit full height sheqthing. For woll, it is the lorgest force on any segment,
Co - PerforationfactorJrom SDPWS Table 4.3.3,5.
C-Sheathingcombinationrule,A=Addcapocities,s=Strongestsideonly,X=SilongestsideortwiceweakesL
Totol - Combined inL and ext. unit sheqr capacity inc. perforationfqctor'
V - For wall: Sum of combined shear capacitiesfor qll segmenB on wqll. For shearltne: sum ofoll wall capdcities on line.
Crit Resp - Criticql response = v/Totql - design shear force/unit shear capacity for critical segmenton wall or shearline.
"5" indicates that the seismic design criterion was criticol in selecting woll.
Notes:
Refer to Elevation View diagrams for individual tevel for uplift onchorage force tfor perforated wolls given by SDPWS 4.3.6.4.2,4.
Allowable shear values have been reduced to 140% ofpublished values.
E
North-South
shearlines \w7\Gr'
lor
Dir , | ,-r*
Shear Force lptrl
I vTrnsv tlbsl I v/L
Atlowable Shear [plf]
rnt I rxt I co I rotal I vlur1
crit.
Resp.l-lrolt spacing
16d nail
spacing
Wall 1-1
Wall 1-2
Wall 1-3
Wall4-2
Wall4-3
Ln5. Levl
Both
Both
Both
Both
Both
Both
76.8
76.4
76.8
1_11.7
122.3
29.9
76.4
76.4
126.9
t22.3
32.2
1190
344
614
2064
795
543
260
260
260
260
260
260
1
7
1
O.BB
1
0.93
260
260
260
)79
260
241
4030
1300
2080
4224
1690
4383
0.3
0.3
0.3
0.49
0.47
0.12
Lf2" Dia.x48" o.c.
1f2" Dia.x 48" o.c.
1/2" Dia.x 48" o.c.
l/2" Dta.x48" o.c.
L12" Dia.x 48" o.c.
1/2" Dia.x48" o.c.
t2
72
l2
L2
72
E-W
Shearlines Gp
For
Dir I ,-r*
AsD shear Force [plfl
V flbsl I vmax I v
Allowable Shear Iplf]
rnt I txt I co I tot"t I vtrurl
Crit.
Resp.I-bolt spacins
16d nail
spacing
WallA-1
WallA-3
Wall A-4
WallC-1
WallC-2
LnD, Levl
7
1
1
1
1
Both
Both
Both
Both
Both
Both
177.5
719.2
1OB,B
0
42.2
148.5
71,7.5
138.4
195.8
42.2
9'19
1511
392
0
924
tTal
1
1
1
1
1
1
260
260
260
260
260
260
1
0.86
0.56
I
1
0.7
260
224
744
260
260
ta2
21.66
2B3B
520
5720
2177
0.45
0.53
0.7 5
0.76
o.a2
l/2" Dia.x48" o.c.
7/2" Dia.x48" o.c.
1,/2" Dia.x48" o.c.
1/2" Dia. x 48" o.c.
l/2" Dta.x48" o.c.
72
t2
11
72
11
North-South
shearlines Gp
For
Dir r I u-"*
Shear Force
v ltbsl I v/L
lplfl
I vTrus
Allowable Shear Iplfl
rnt I rxt I co I rotut I v1ru.1
Crit.
Resp.J-bolt spacing
16d nail
sDacing
Ln1, Lev2
Ln4,Levz
I
1
Both
Both
77.9
51.4
77.9
52.3
1409
t49A
7
1
260
260
1
0.98
260
255
5093
7443
0.28
0.2
t2
l2
E-W
shearlines GD
For
Dir , | ,-"*
AsD shear Force [plfl
v tlbsl I vmax I v
Auowable shear [plf]
rnt I rxt I co I rotrt I v1tu.1
Crit.
Resp.l-bolt spacing
16d nail
sDacins
WallA-1
WallA-2
WallA-3
LnD, Lev2
Both
Both
Both
Both
74.2
1.79.6
94.3
57.6
74.2
t2s.4
94.3
63.5
618
419
526
1345
260
260
260
250
1
0.95
I
0.91
260
244
260
236
2).66
B6B
1450
5503
0.29
0.48
0.36
0.2+
72
12
t2
l2
Client: Bruce Wiechert
Project:19.298 1-O/24/201,9
t0/42
WoodChuck Engineering
1
1
1
1
1
1
1
1
d&
Y"9"99.r*q[
Note: This table includes tension holddown forces only.
Dead load contribution to combined force is factored ty 0.50 load combination factor
Tensile Results - lvl 1
Bridlewood Plan
Eugene,0regon
Line"
wall Posit'n
Tensile ASD [wind)
Holddown Force Ubsl
Force (mil.)
Tensile AsD (seismic)
Hotddown Force Ibs]
Force (max.)v Hold-down Anchor bolt
lnro'*\\ tauet /I- Bolt Spacing
1-1
t-2
t-2
1-3
+2
4-2
+3
+3
5-1
5-1
A-1
A-3
A-3
A-4
A-4
c-2
c-2
D-1
D-1
L
l, End
R End
R End
L End
R End
L End
R End
L End
R End
L End
R End
L End
R End
L End
R End
L End
R End
L End
366
1650
1674
2536
1443
1505
2173
2923
757
1059
985
3saa
2454
1454
1931
823
423
1078
4A4
444
L124
1451
420
420
332
212
2428
11.08
986
986
1
1
1
1
1
I
1
1
1
1
1
1
1
1
L
1
1
1
l
1
HDU2
HDU2
HDU2
HDU2
HDU2
HDU2
HDU2
HDU2
HDU2
HDU2
HDU2
HDU2
HDU4
HDU2
HDU2
HDU2
N/R
N/R
N/R
N/R
ssTB16
SSTB15
SSTB16
SSTB15
SSTB15
ssTB16
ssTB16
ssTB16
ssTB16
ssTB16
SSTB15
ssTB16
ssTB20
ssTB16
ssTB16
ssTB16
N/R
N/R
N/R
A
A
A
A
A
A
A
B
A
A
1/2" Dia. x 48" o.c.
1/2" Dia. x 48" o.c.
L12" Dia.x 48" o.c.
1/2" Dia. x 48" o.c.
r/2" Dia.x 48" o.c.
1,/2" Dia.x 48" o.c-
7 /2" Dia. x 48" o .c.
l/2" Dia.x48" o.c.
1/2" Dia.x 48" o.c.
7 /2" Dia. x 48" o .c.
1, /2" Dia. x 48" o.c.
l/2" Dia.x48" o.c.
l/2" Dia.x48" o.c.
1,/2" Dia.x 48" o.c.
l/2" Dia.x 48" o.c.
l/2" Dia.x 48" o.c.
1,/2" Dia.x 4A" o.c.
7/2" Dia.x48" o.c.
1/2" Dia.x48" o.c.
Dia. x 48"
Clienti Bruce Wiechert
Projecr 19.298
10/24/20t9
tt/42
WoodChuck Engineering
#ffi
WoodChuck
Tensile Resuls - lvl 2
Bridlewood Plan
Eugelre, Oregon
2nd floor fo rce
Note: This tqble includes tension holddown forces only.
Dead lood contribution to combined force is foctored by 0.60 load combinotion factor
Client: Bruce Wiechert
r0/24/207e
12/42
Line-
Wall Posit'n
Tensile ASD (wind)
Holddown Force [bs]
Force (max.)
Tensile ASD (seismic)
Holddown Force [bs]
Force (max.)Hold-down
1r--G
\ label /
16d common nail sill
plate nailing (in.)
1-1
1-1
4-7
4-7
A-1
A-1
A-3
A-3
A-2
A-2
D-1
D-1
L End
R End
L End
R End
L End
R End
L End
R End
L End
R End
L End
R End
14Zl
7464
646
688
447
1 156
1168
1 190
2266
2450
731
777
326
169
765
759
759
1455
1575
7
7
1
7
7
1
1
1
1
1
1
7
cs16 20-10d
cs15 20-10d
cs].6 20-10d
cs16 20-10d
cs16 20-10d
cs16 20-10d
cs16 20-10d
cs16 20-10d
MST37 22-t6d
MST37 22-r6d
C
C
C
C
C
C
C
C
D
D
12
1_2
72
72
72
1,2
L2
12
12
12
t2
t2
Project: 19.298 WoodChuck Engineering
v
tr&
lYggf9,tlq\
1 1 20 Arthur Street
Eugene, Oregorr 97402
541 -357-5532
Proiect address
€*rc*(0i?-
Date Proiect #
ta /23 /rl 11. Z16
Corlrvecrro>r Ctt.n* ,n-T [errn Fl-c..n
Wlur Lt hrf A
6J'A,
w*?r
0 6 - Yn'
qas lb * lls* 15
llla rL "!- 3s8& it
2trt t tL
rt; sa tt
\,\,.&
lpr'"$
lt/*u. Lr*q; A &
b\r\F-b
|;n t*,t>
f -aw
w"t €
!-,tOU 1 rrlrl SS-T El Ir O Far*n* tlTr E p
W' r-L
Sf,*r>
gu\ t";11
S --a Lr*,
w-+ r
Tb'rft L Upu F?
/e\ fi")?.ti sratrP
$?*afnrr'r;"
5le!p
O rr-rr#;l lL &rf:
] llz'' x r, Vat Br*\
hDus h,, SSrg 2,
firszv
'TU O Jl'tT
$?vD B flot-
6 nIELY
SX?{E{&to(t
?6 r{.y *{
Srr*P S
$'rx4?Frrq
S *l t tl Fa"r'1
; ll ?a" PS*tr
73 /42
1
It^I
I 120 Arthur Street
Eugene, Oregon 97402
541 -357-5532
Proiect address
tCI125 I t1
Proiect #
t1. zl b
Date
CovecdP P*"tro (E*.rr",ce. "rtc>r\i
TtrugS '?"-tA F|\r) Z.y& rr\.
O'. t't p r?c h, 2,1 '
Ff.rrF.f C0Arstlrverter-.
yr l2 e)
^^pft
fi|.s rle
tab* tv
tJ,.,ast>
> P&","1
f\lc|'vA L
r ts,D.
PdAPe*rOl(uur{ & I
Prpgrler :
frqr prp)(s) :
( $n pr6'){rz'} :qE
J-
foa-{ g r}J Filf€ Bcicf F
atn.o, 3ri* {Wr, \| 'Z'4 ?otar )
T; rJU erllL 3
r)f[:q1t lv -../Vost
t.
I
I
I'.*.>
I 1
IZ b3 \L
C*pnt rr.r Far ilq" +Lrq Sr&rtt^,abb rbs
* See Atrr(- f?-\x.l-!aL-t F rL LA€\ SCf.ehJ
\)vvtF'T
TASLT
\E PST
? . tz- A 1r., 11r; laf tt
tz " sPel
b8 PLr
{ta ?LFJ { o' l*\i?? 1L ^^:^fr;F^i^^^^^
Laq srrfte)
p.1: fi.f .
fJqra S"r\
fsj?'
&
{L
(z') 3t,,*" +
Tu dx&
Lseq Pei;r c4s @ ErAq ?a Ps{?
t4/42
ffi&
Xgr$9.t^,lqI
1,.," *
i
Member Member Section Material Remarks
H201,Sawn 4xB DI.'-1, No. 2
H101 5.125" x12"24F-V4 DF/DF Glulam
H102 Sawn 4x10 DF-L, No. 2
H103 3.125" x 15"24F-V4 DF/DF Glulam
H104 Sawn 4xB DF-L, No. 2
##+r:;s--1.3*3-r-a
!{er$9.1,,!*h
Header Schedule
Bridlewood Plan
Eugene, Oregon
Header Schedule
Client: Bruce Wiechert
Project: 19.29B tT/6/201e
ts/42
WoodChuck Engineering
l7
#h
WoodClrirc(
Header Loads
Bridlewood Plan
Eugene, Oregon
a
Client: Bruce Wiechert
Project:19.298
Member Length, ft,
Uniform Loads
L",0.1 D."dl u".l I
rrc"l wiatn, n.l Load, plfl Load, plrlt.orJ ro
Point Loads
t*.1 *.o,,ol Location
H20L
5.00 Roof DL
RoofSL
16.3
16.3
x=
276.31
406.3
0 6.0 Sawn 4xB DF-1, No.22'16.31 406.3
lt 101
9.50 RoofDL
RoofSL
Wall DL
16.3
t6.3
8.0
'rr.rl 406.3
0
0
0
0
2.7
2.7
2.7
9.5
H201
H201
829.0
1219.4
2.7',
2.7',
5.125" x 12"
24F-V4 DF /DF
Glu lam356 3l 406.3
H 102
5.00 Roof Dt
RoofSI-
Wall D[
16.3
t6.3
8.0
t=
'rr.rl 406.3
0 6.0 Sawn 4x10 DILL, No.2356.31 406.3
H 103
16.00 Roof Dt
RoofSt
13.0
13.0
22t.ol
325.0
0 16.0 3.125" x 15"
24F-V4 DF /DF
Glulam22 L.Ol 325.O
H 104
4.50 Roof Dl,
Roof SL
5.0
5.0
t=
Bs ol
125.0
0 4.5 Sawn 4xB I)f-1, No. 2Bs.ol 12s.0
11/6/20re
1,6/42
WoodChuck Engineering
Member Member Section Material Remarks
B 101 8.75" xL2"24F-V4 DF/DF Clulam
81,02 Sawn 4x12 DF-1, No. 2
B103 Sawn 6x12 DF-1, No. 2
BL04 3.5" x7.25"1.3E LSL
B 105 Sawn 4xB DF-1, No. 2
#-Trrrrj---:u*r_.j
P,g'g9.c.tr.,{ql:
Beam Schedule
Bridlewood Plan
Eugene, Oregon
Beam Schedule
Client: Bruce Wiechert
Proiect:19.298 1r/6/20L9
17 /42
WoodChuck Engineering
d-hrl'+ q!!w
'fu.i,i-aciri,"(
Clienti Bruce Wiechert
Proiect:19.298
Beam Loads
Bridlewood Plan
Eugene, Oregon
1,2
Floor 40
25
Member Lensth. ft ,","1 -,.*t'*i -*=i',"".trr1... J ..
Point Loads
r-"1 *.o.,ol Location
Member specifications
Section Material
8101
20.20 Roof DL
Floor DL
Floor LL
10.0
10.0
,,3 31
400.0
0 20.2 8.7 5" x 12"
24F-V4 DF /DF
Glulami20.01 400.0
B1 02
4.00 Floor DL
Floor LL
3.5
3.5
t=
4201
140.0
0 4.0 Sawn 4xl2 DF-1. No.2qz.ol r4o.o
8103
6.33 Roof DL
Roof Sl,
4.2
4.2,-
71.41
105.0
0 6.3 Sawn 5x12 DILl,, No.271.41 ros.o
B1C4
6.00 Roof DL
RoofSL
Wall DL
8.0
8.0
8.0
'ra.al 200.0
0
0
0
0
3.7
3.7
3.7
6.0 3.5" x7.25"1,38 LSLn2.ol 2oo.o
8105
7.50 Roof DL
Roof sL
8.0
8.0
136.01
200.0
0 7.5 Sawn 4x8 l)l-1, No.2136.01 2oo.o
t|l6/207e
t8/42
WoodChuck Engineering
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon 97402
541-357-5532
0
0
Wood Beam Software ENERCALC, rNC. 1983-201 Build:'12.'19.8.31
Lic. #: KW-06009596
DESCRIPTIO H201 - master bedroom
CODE REFERE'VCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set: IBC 2018
Material Properties
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
900 psi
900 psi
350 psi
625 psi
Prll
Perp
Fb+
Fb-
Fc-
Fc-
Fv
Ft
1 80 psi
575 psi
E : Arlodulus of Elasti
Ebend- xx 1600ksi
Eminbend - x 580ksi
Density 31 .21pcf
4063
4x8
Span = 6.0 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Loads on all spans...
Uniform Load on ALL spans
DES'GN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
Load Combination
Location of maximum on span =
Span # where maximum occurs =
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
D = 0.0170, S = 0.0250 ksf, Tributary Width = 16.250 ft
0.89s 1
4x8
1,202.00psi
1,345.50psi
+D+S
3.000ft
Span # 1
Maximum Shear Stress Ratio
Section used for this span
0.469 : 1
4x8
97.18 psi
207.00 psi
+D+S
0.000 ft
Load Combination
Location of maximum on span =
Span # where maximum occurs =
1 074 >=360
0 <360
639>=240
it <240
-Spbn#1
0.067 in Ratio =
0.000 in Ratio =
[.'l 'l f, ip Ratio =
0.000 in Ratio =
Maximum Forces & Stresses for Load Combinations
Load Combination
Segment Length SPan #
Max Stress Ratios Moment Va[,eq'Snear Values
MV C6 Crn, C; Cr Cm Ct CL M fb E''b Vfv-F'v
D Only
Length = 6.0 ft 1 0.462 0.243
+D+S
Length = 6.0 ft 1 0.893 0.469
+D+0.750S
Length = 6.0 ft 1 0.760 0.400
+0.60D
Length = 6.0 ft 1 0.156 0.082
Overall Maximum Deflections
0 90
.60
.00
.00
.00
.00
.00
.00
.00
00
00
00
00
00
00
00
.300
.300
.300
.300
.300
.300
.300
1
1
1
1
1
1
1
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.24
J.U /
2.61
0.75
- c.30
- 16?.C0
- ,0.u0
207.00
0.00
207.00
0.00
288.00
- 0]00
486.52- 1053.00
0.00
1,202.00 1345.50
0.00
1 ,023.13 1 345.50
0.00
291 .91 1872.00
- J.3X 0.00
0.6-7 39.34-0{0 0.00
1 .64 97.'l B0.00 0.00
1.40 82.720.00 0.00
0.40 23.60
1.15
1.15
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
0.000+D+S 0.1126 3.022 0.0000
79/42
Analysis Methoa\llowable Stress Design
Load CombinatlBC 2018
Wood Species Douglas Fir-Larch
Wood Grade No.2
I
./
WoodChuck Engineering
1'120 Arthur Street
Eugene, Oregon97402
541-357-5532-0
DESCRIPTIO H201 - master bedroom
Vertical Reactions Support notation : Far left is #'Values in KIPS
Load Combination Support 1 Support 2
gverall MAXrmum
Overall MlNimum
D Only
+D+S
+D+0.750S
+0.60D
S Only
2.O48
1.219
0.829
2.048
1.743
0.497
1.219
2.O44
1.219
0.829
2.048
1.743
0.497
1.219
20/42
Wood Beam Build:12.19.8.31SoftwareINC.
WoodChuck Engineering
'l 120 Arthur Street
Eugene, Oregon 97402
541-357-5532
0
0
ood 2.EN
DESCRIPTIO H101 - living room
CODE REFERETVCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set: IBC 2018
Material Properties
Analysis lVlethoAllowable Stress Design Fb +
Load CombinatlBC 2018 Fb -
Fc - Prll
Wood Species DF/DF Fc - PerP
Wood Grade 24F-V4 Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
s(1 219)
3.1 25x1 0.5
Span = 9.50 ft
2,400.0 psi
1,850.0 psi
1,650.0 psi
650.0 psi
265.0 psi
'1 ,1 00.0 psi
E : lrlodulus of Elasti
Ebend- xx 1 ,800.0 ksi
Eminbend - x 950,0ksi
Ebend- yy 1 ,600.0 ksi
Eminbend - y 850.0ksi
Density 31.210pcf
o(o.27625\ S(0.40625)f r---ii--E--a
D(0.8288) g(0r09)' 'fr-T--rr--r
I
:
D(1.443 L(3.024)
99
)(o.27625\ S(0,40625)
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Load for Span Number 1
Uniform Load: D = 0.0170, S = 0.0250 ksf, Extent = 0.0 -->> 2.70ft, TributaryWidth = 16.250 ft, (Roof load)
Point Load : D = 0.8288, S = 1 .219k @2.7Oft,(H201)
PointLoad : D =0.8288, S = 1.219k@8.70ft, (H201)
Uniform Load : D = 0.010 ksf, Extent = 0.0 -->> 2.70 ft, Tributary Width = 8.0 ft, (Wall load)
Uniform Load : D = 0.010 ksf, Extent - 8.70 ->> 9.50 ft, Tributary Width = 8.0 ft, (Wall load)
Point Load : D = 1 .443, L= 3.024k @ 6.50ft, (B101)
Uniform Load: D = 0.0170, S =0.0250 ksf, Extent- 8.70 ->> 9.50ft, TributaryWidth = 16.250ft, (Roof load)
DES'GN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
Load Combination
Location of maximum on span =
Span # where maximum occurs =
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
0.940 1
3.125x10.5
2,256.79psi
2,400.00psi
+D+L
6.484ft
Span # 1
Maximum Shear Stress Ratio
Section used for this span
' 0.577
3.125x10.5
1
r Sa.Oo is;
265.00 psi
Load Combination
Location of maximum on span =
Span # where maximum occrJrs :
793 >=360
,-i <360
355 >=240
a: <240
. +D+L
0 144 in Ratlo =
0.000 in Ratio =
0.320 in Ratio =
0.000 in Ratio =
Maximum Forces & Stresses for Load Combinations
Load Combination
Segment Length Span #
Max Stress Ratios Moment Values Shear Values
M V C6 Crnr C; Cr Cm Ct CL M fb F'b VtuF'v
D Only
Length = 9.50 ft
+D+L
Length = 9.50 ft
+D+S
Length = 9.50 ft
0.00
962.90 2160.00
0.00
2,256.79 2400.00
0.00
1,611.52 2760.00
1
1
1
0.446
0.940
0.584
0.316
0.577
0.484
0.90
1.00
1.15
.00
.00
.00
.00
.00
00
00
00
00
00
4.61
10.80
7.71
0.00
238.50
0.00
265.00
0.00
304.75
1.000
1.000
1.000
1.000
1.000
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.00
t.oD
0.00
3.35
0.00
3.22
0.00
75.30
0.00
153.00
0.00
147.42
2t/42
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon 97402
541-',357-5532
0
0
Bea 1
DESCRIPTIO
Load Combination
Segment Length
H101 - living room
Max Stress Ratios [\/oment Values Shear Values
Span# M V C6 Cpru C; Cr Cm Ct CL M fb F'b V fv F'v
+D+0.7501
Length=9.50ft 1 0.644 0.390
+D+0.750L+0.750S
Length = 9.50 ft 1 0.829 0.532
+0.60D
Length=9.50ft 1 0.150 0.107
Overall Maximum Deflections
1.000
1.25 1.000
1.000
1.15 1.000
1.000
1.60 1.000
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
.00
.00
.00
.00
.00
.00
9.25
10.95
2.76
0.00
2.83
0.00
3.55
0.00
0.99
0.00
129.35
0.00
162.13
0.00
45.1 8
0.00
331.25
0.00
304.75
0.00
424.00
0.00
1,933.32 3000.00
0.00
2,289.03 2760.00
0.00
577.74 3840.00
Load Combination Span Max. 'L" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+0.7501+0.750S
Vertical Reactions
0.3204 4.889
Support notation : Far left is #'
0.0000
Values in KIPS
0.000
Load Combination Support 'l Support 2
Overall MAXimum
Overall MlNimum
D Only
+D+L
+D+S
+D+0.750L
+D+0.7501+0.750S
+0.60D
L Only
S Only
4.120
1.930
1.956
2.911
3.886
2.672
4.120
1.174
0.955
1.930
5.391
1.930
2.392
4.461
4.322
3.943
5.391
1.435
2.069
1.930
22/42
1
WoodChuck Engineering
1120 Arthur Street
Eugene, Oregon 97402
541-357-5532
0
0
Wood Beam INC. 1 Build:12.Software
DESCRIPTIO H102 - rear entry
CODE REFERENCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set : IBC 20'18
Material Properties
Analysis MethoAllowable Stress Design Fb +
Load CombinatlBC 2018 Fb -
Fc - Prll
Wood Species Douglas Fir-Larch Fc - Perp
Wood Grade No.2 Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
900.0
900.0
1,350.0
625.O
180.0
575.0
psi
psi
psi
psi
psi
psi
E : tulodulus of Elasti
Ebend- xx 1 ,600.0 ksi
Eminbend - x 580.0ksi
Density 31.210pc'f
4x 10
Span = 6,0 ft l
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.010 ksf, Tributary Width = 8.0 ft, (Wall load)
Uniform Load : D = 0.0170, S = 0.0250 ksf, Tributary Width = 16.250 ft, (Roof load)
DES'GTV SUMMARY
Maximum Bending Stress Ratio
Section used for this span
Load Combination
Location of maximum on span =
Span # where maximum occurs =
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
0.664 1
4x10
824.96psi
1,242.00psi
+D+S
3.000ft
Span # 1
Maximum Shear Stress Ratio
Section used for this span
0.381 : 1
4x10
78.91 psi
207.00 psi
+D+S
0.000 ft
Siran#1--:-.
0.032 in Ratio =
Q.QQQ in Ratio =
0.061 in Ratio =
0.000 in Ratio =
Load Combination
Location of maximum on span =
Span # where maximum occurs =
2231 >=360
(i<360
1189>=240
t) <240
Maximum Forces & Stresses for Load Combinations
Load Combination
Segment Length Span #
Max Stress Ratios MomentValue" - --Snear Value+ ^ -
M V Cd Crnr C; Cr Cm Ct CL M fb -F'b Vfv-F'v
D Only
Length = 6.0 ft
+D+L
Length = 6.0 ft
+D+S
Length = 6.0 ft
+D+0.750L
Length = 6.0 ft
+D+0.750L+0.750S
Length = 6.0 ft
+0.60D
Length = 6.0 ft
1
1
1
1
0.397
0.357
0.664
0.286
0.576
0.1 34
0.228
0.205
0.381
0.164
0.330
0.077
0.90
1.00
1.15
1.25
1.15
1.60
.00
.00
.00
.00
.00
.00
.00
.00
.00
.00
.00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
.200
.200
.200
.200
.200
.200
.200
.200
.200
.200
.200
1
1
1
1
1
1
1
1
1
1
1
1.00
1.00
1.00
'I .00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
'---f,:00
385.43 - 972.00
0.00
385.43 1080.00
0.00
824.96 1242.00
0.00
385.43 1350.00
0.00
715.08 1242.00
0.00
231 .26 1728.00
o.JJ-- 0.00 --cc0
o.BQ- 36.87: -ie?.eo
0 r0 0.00 ' +00
o.b0- 36.87 18o.oo0.00 0.00 0.00
1.70 78.91 207 .000.00 0.00 0.00
0.80 36.87 225.000.00 0.00 0.00
1.48 68.40 207.OO0.00 0.00 0.00
0.48 22.12 288.00
.00
.00
.00
.00
.00
.00
.00
.00
.00
.00
.00
1
1
1
1
1
1
1
1
1
1
1
1.60
1.60
3.43
1.60
2.97
0.961
1.00
1.00
.t.00
1.00
23/42
I
Desiqn 0K
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon 97402
541-357-5532
0
0
- rear
Overall Maximum Deflections
Load Combination Span Max. "-" Defl Location in Span Load Combination Max.Defl Location Span
+D+S 1 0.0606 3.022
VertiCal ReaCtionS Support notation : Far left is #'
0.0000
Values in KIPS
0.000
Load Combination Support 1 Support 2
Overall MAXimum
Overall MlNimum
D Only
+D+L
+D+S
+D+0.7501
+D+0.7501+0.750S
+0.60D
L Only
S Only
2.288
1.219
1.069
1.069
2.288
1.069
1.983
0.641
2.288
1.219
1.069
1.069
2.288
1.069
1.983
0.641
1.219 1.219
24/42
Wood Beam Build:12.19.8.31INC.Software
WoodChuck Engineering
1120 Arthur Street
Eugene, Oregon97402
541-357-5532
0
0
DESCRIPTIO H103 - garage door
CODE REFERENCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set: IBC 20'1 8
Material Properties
Analysis lVethoAllowable Stress Design Fb +
Load CombinatiBC 2018 Fb -
Fc - Prll
Wood Species DF/DF Fc - PerP
Wood Grade 24F-V4 Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
2,400.0 psi
1,850.0 psi
1,650.0 psi
650.0 psi
265.0 psi
1 ,1 00.0 psi
E : Modulus of Elasti
Ebend- xx 1,800.0ksi
Eminbend - x 950.0ksi
Ebend- yy 1,600.0ksi
Eminbend - y 850.0ksi
Density 31.21OpcI
aa4
3.125x'15
Span = 16.0 ft
.lt_
T
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Loads on all spans...
Uniform Load on ALL spans
DES'G'V SUMMARY
Maximum Bending Stress Ratio
Section used for this span
Load Combination
Location of maximum on span =
Span # where maximum occurs =
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
D = 0.0170, S = 0.0250 ksf, Tributary Width = 13.0 ft
0.648 1
3.125x15
1 ,789.1 3 psi
2,760.00psi
+D+S
8.000ft
Span # 1
lvlaximum Shear Stress Ratio
Section used for this span
ffi
0.388 : 1
3.125x15
1 18.35 psi
304.75 psi
+D+S
. 14.774ft ---- Span#1
Load Combination
Location of maximum on span =
Span # where maximum occurs =
.305 in Ratio =
.000 in Ratio =
.512 in Ratio =
.000 in Ratio =
630 >=360
I <360
375>=240
a <240
0
0
0
0
Maximum Forces & Stresses for Load Combinations
Load Combination
Segment Length SPan #
lt/ax Stress Ratios Moment Values Snear Values
M V Cd Crw C; Cr Cm Ct CL IM fb F'b Vfv-F'v
D Only
Length = 16.0 ft 1 0.335 0.201
+D+S
Length = 16.0 ft 1 0.648 0.388
+D+0.750S
Length = 16.0 ft 1 0.552 0.331
+0.60D
Length = 16.0 ft 1 0.113 0.068
Overall Maximum Deflections
0.90
1.15
1.15
1.60
.00
.00
.00
.00
.00
.00
.00
00
00
00
00
00
.000
.000
.000
.000
.000
.000
.000
1.00
1.00
7.O7
17.47
14.87
4.24
C.JC'
1.50
0.90
3.lU
0.00
3.'15
0.00
0.90
0.00
47.90
0.00
1 18.35
0.00
100.74
0.00
28.74
-c.c3
':33 q0-{00
304.75
0.00
304.75
0.00
424.00
00 1.00
00 1.00
00 1.00
00 '1 .00
00 1.00
00 1.00
00 1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
- --J:00
724.1: -2t3X.00
0.00
1,789.13 2760.00
0.00
1,522.89 2760.00
0.00
434.50 3840.00
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
0.000+D+S 0.5119 8.058 0.0000
2s/42
Wood Beam Build:12.19.8.31Software
1
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon97402
541-357-5532
0
DESCRaPTIO H103 - garage door
Vertical Reactions Support notation : Far left is #'Values in KIPS
Load Combination Support 1 Support 2
uverall MAXtmum
Overall MlNimum
D Only
+D+S
+D+0.750S
+0.60D
S Only
4.36U
2.600
1.768
4.368
3.718
1.061
2.600
4.36E
2.600
1.768
4.368
3.718
1.061
2.600
26/42
Wood Beam Software Build:12.
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon 97402
541-357-5532
0
0
DESCRIPTIO H104 - front entry
CODE REFERE'VCES
Calculations per NDS 2015, IBC 2015, CBC 2016. ASCE 7-10
Load Combination Set : IBC 2018
Material Properties
Analysis MethoAllowable Stress Design Fb +
Load CombinatilBC 2018 Fb -
Fc - Prll
Wood Species Douglas Fir-Larch Fc - Perp
Wood Grade No.2 Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
psi
psi
psi
psi
psi
psi
0
0
0
0
0
0
900
900
,350
625
180
575
E : Modulus of Elasti
Ebend- xx 1,600.0ksi
Eminbend - x 580.0ksi
Density 31.210pcf
4xB
Span = 4.50 fi
.l
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Loads on all spans...
Uniform Load on ALL spans
DES'GN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
Load Combination
Location of maximum on span =
Span # where maximum occurs =
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
D = 0.0120, L = 0.040 ksf, Tributary Width = 5.0 ft
&.22G 1
4x8
257.57psi
1 ,170.00psi
+D+L
2.250ft
Span # 1
Maximum Shear Stress Ratio =
Section used for this span
r
Load Combination
Location of maximum on span =
Span # where maximum occurs =
51 73 >=360
.t <360
3979>=240
;<240
W
0-142:1
4x8
25.49 psi
180.00 psi
+D+L
:3.909tt-' Span#1-:-'
0.010 in Ratio =
Q.QQQ ip Ratio =
0.014 in Rutio =
0.000 in Ratio =
Maximum Forces & Stresses for Load Combinations
Load Combination
Segment Length SPan #
Max Stress Ratios
M
[\,4oment Valucs Shear Value:
V C6 Crru C; Cr Cm C t CL M fb 1-rb
D Only
Length = 4.50 ft 1 0.056 0.036
+D+L
Length = 4.50 ft 1 0.220 0.142
+D+0.7501
Length = 4.50 ft 1 0.142 0.092
+0.60D
Length = 4.50 ft 1 0.019 0.012
Overall Maximum Deflections
0.90
1.00
1.25
1.60
.00
.00
.00
.00
.00
.00
.00
.300
.300
.300
.300
.300
.300
.300
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.15
0.66
0.53
0.09
59.4+
257.57
208.04
35.66
Ji0
1oJi.00
0.00
1 170.00
0.00
1462.50
0.00
1872.00
O.UU
0.10
0.00
0.43
0.00
0.35
0.00
0.06
0.00 J.co
5.88 -f62.CJ
0.00 - f.00
25 49 180.000.00 0.00
20.59 225.O00.00 0.00
3.53 288.00
Load Combination Span lVlax. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
0.000+D+L 0.0136 l.zoo 0.0000
27 /42
Wood Beam Software INC.Build:'12.
fv F'v
1.00
1.00
1.00
1.00
1.00
1.00
'1 .00
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon 97402
541-35t-5532
0
0
Vertical Reactions Support notation : Far left is #'Values in KIPS
Load Combination Support '1 Support 2
Overall [t/AXimum
Overall MlNimum
D Only
+D+L
+D+0.7501
+0.60D
L Only
0.585
0.450
0.1 35
0.585
0.473
0.081
0.450
0.585
0.450
0.1 35
0.585
0.473
0.081
0.450
28142
Wood Beam tNc. 1Software
WoodChuck Engineering
1120 Arthur Street
Eugene, Oregon97402
541-357-5532
0
0
DESCRIPTIO 8101 - floor beam @ 10'o.c.
CODE REFERE'VCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set :ASCE 7-16
Material Properties
Analysis MethoAllowable Stress Design Fb +
Load CombinatASCE 7-16 Fb -
Fc - Prll
Wood Species DF/DF Fc - PerP
Wood Giade 24F-V4 Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
8.75x12
Span = 20.50 ft
2,400.0 psi
1,850.0 psi
1,650.0 psi
650.0 psi
265.0 psi
1 ,100.0 psi
E : Modulus of Elasti
Ebend- xx 1 ,800.0 ksi
Eminbend - x 950.0ksi
Ebend- yy 1 ,600.0 ksi
Eminbend - y 850.0ksi
Density 31.210pcf
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Loads on all spans...
Uniform Load on ALL spans : D = 0.0120, L = 0.030 ksf, Tributary Width = 9.833 ft
DES'GN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
0"574 1
8.75x12
1,308.01 psi
2,280.48 psi
+D+L
'10.250ft
Span # 1
Maximum Shear Stress Ratio
Section used for this span
0.218:1
8.15x12
57.75 psi
265.00 psi- +D+L - -.' 0.000[t -:- Qfqn#1 . --
Load Combination
Location of maximum on span =
Span # where maximum occurs =
lVlaximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Load Combination
Location of maximum on span =
Span # where maximum occlrrs =
0.520 in Rutio =
0.000 in Ratio =
0.768 in Ratio =
0 000 in Ratio =
473 >=360
I <360
324>=240
, <240
Maximum Forces & Stresses for Load Gombinations
Load Combination
Segment Length SPan #
lVlax Stress Ratios Ir4oment Values Shear Varues
M V Cd Crnr C; Cr Cm Ct CL M fb -F,b '/--^ fv f'r'
D Only
Length = 20.50 ft 1 0.206 0.078
+D+L
Length = 20.50 ft 1 0.574 0.218
+D+0.7501
Length = 20.50 ft 1 0.381 0.145
+0.60D
Length = 20.50 ft 1 0.069 0.026
Overall Maximum Deflections
0.90
1.00
1.25
1.60
0.950
0.950
0.950
0.950
0.950
0.950
0.950
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
'1 .00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
'1 .00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
.00
.00
.00
.00
.00
.00
.00
7.39
22.89
19.O2
4.44
0.00
1.31
0.00
4.04
0.00
3.36
0.00
0.78
u.00
422.51 2052.43
0.00
'1 ,308.01 2280.48
0.00
1,086.63 2850.60
0.00
253.51 3648.77
0.00 i.6J
18.65 233.50
0.00 0.00
57.75 265.00
0.00 0.00
47.98 331 .25
0.00 0.00
11.'19 424.00
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+L 0.7679 10.325 0.0000
)q lL)
Wood Beam Software copyright ENERCALC, lNC. 1983-2019, Build:12.19.8.31ffiffi#ffixffiffiri$
1
1
1
1
1
1
1
1
0.0001
WoodChuck Engineering
'l 120 Arthur Street
Eugene, Oregon 97402
541-357-5532
0
DESCR!
Vertica! Reactions
o.c.
Support notation : Far left is #'Values in KIPS
Load Combination Support 1 Support 2
Overall [\/AXimum
Overall MlNimum
D Only
+D+L
+D+0.7501
+0.60D
L Only
4.466
3.024
1.443
4.466
3.710
0.866
3.024
4.466
3.024
1.443
4.466
3.710
0.866
3.024
30/42
Wood Beam Build:12.19.8.31INC.
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon97402
541-357-5532
0
0
DESCRIPTIO 8102 - near stairs
CODE REFERETVCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set : IBC 2018
Material Properties
Analysis lVlethoAllowable Stress Design Fb +
Load CombinatlBC 2018 Fb -
Fc - Prll
Wood Species Douglas Fir-Larch Fc - Perp
Wood Grade No.1 Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
900.0 psi
900.0 psi
1,350.0 psi
625.0 psi
180.0 psi
575.0 psi
E : Alodulus of Elasti
Ebend- xx 1 ,600.0 ksi
Eminbend - x 580.0ksi
Density 31.210pcf
&a
4x12
Span = 4.0 ft l
Applied Loads Service loads entered. Load Factors will be applied for calculations
Loads on all spans...
Uniform Load on ALL spans
DES'G/V SUMMARY
Maximum Bending Stress Ratio
Section used for this span
Load Combination
Location of maximum on span =
Span # where maximum occurs =
Maximum Deflection
Max Downward Transient Deflection
Ivlax Upward Transient Deflection
Max Downward Total Deflection
l\ilax Upward Total Deflection
D = 0.0120, L = 0.040 ksf, Tributary Width = 3.50 ft
0.06& 1
4x12
59.1 6 psi
990.00psi
+D+L
2.000ft
Span # 1
0.041 : 1
4x12
7.39 psi
180.00 psi
+D+L
3.066 ft
Sean # 1 --
fi/laximum Shear Stress Ratio
Section used for this span
0.001
0.000
0.002
0.000
in Ratio =
in Ratio =
in Ratio =
in Ratio =
Load Combination
Location of maximum on span =
Span # where maximum occurs =
39321 >=360
it <360
30?47 >=240
l: <240
Maximum Forces & Stresses for Load Combinations
Max Stress Ratios Moment Values S.rear VaruesLoad Combination
Segment Length SPan #M V Cd Crnr C1 Cr Cm Ct CL M fb Fh'V fv -F'v
D Only
Length = 4.0 ft
+D+L
Length = 4.0 ft
+D+0.7501
Length = 4.0 ft
+0.60D
Length = 4.0 ft
0.015
0.060
0.039
0.005
0.90
1.00
1.25
1.60
'1 .00
'1 .00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.011
0.041
0.027
0.004
1 .100
1 .100
1 .100
1.100
1.100
1 .'1 00
1 .100
0.08
0.36
o.29
0.05
. Q.QQ
0.04
- 0.0rr-0.trI
0.00
0.16
0.00
0.03
.00
.00
.00
.00
.00
.00
.00
0.00
13.6q -B-eJ J0
0.00
59.16 990.00
0.00
47.79 1237.50
0.00
8.'19 1584.00
0.00 - 0.0-0
1.71 162.00
o.oo- '
b.c,:
7 .39 180.000.00 0.00
5.97 225.000.00 0.00
1.O2 288.00
Overall Maximum Deflections
Load Combination Span Max. "-" Defl Location in Span Load Combination Ivlax. "+" Defl Location in Span
0.000+D+L 0.0016 2.015 0.0000
31./42
Wood Beam
1
1
1
1
1
1
1
1
WoodChuck Engineering
1120 Arthur Street
Eugene, Oregon97402
541-357-5532
0
0
Vertical Reactions
- near stairs
Support notation : Far left is #'Values in KIPS
W-rtad0hiiek,lE.rngin€srind
Load Combination Support '1 Support 2
OVeialITAXlmum
Overall MlNimum
D Only
+D+L
+D+0.750L
+0.60D
L Only
0.364
0.280
0.084
0.364
0.294
0.050
0.280
0.364
0.280
0.084
0.364
0.294
0.050
0.280
32142
Wood Beam Software copvriqht ENERCALC, lNC. 1983-2019. Build:'12.19.8.31
WoodChuck Engineering
1120 Arthur Street
Eugene, Oregon 97402
541-357-5532
0
0
DESCRIPTIO 8103 - front patio
CODE REFERE'VCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set: ltsC 2018
Material Properties
Analysis MethoAllowable Stress Design Fb +
Load CombinatilBC 2018 Fb -
Fc - Prll
Wood Species Douglas Fir-Larch Fc - Perp
Wood Grade No.2 Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
6x12
Span = 6.330 fi
900.0 psi
900.0 psi
1,350.0 psi
625.0 psi
180.0 psi
575.0 psi
E : llodulus of Elasti
Ebend- xx 1 ,600.0 ksi
Eminbend - x 580.0ksi
Density 31.210pcf
Applied Loads Service loads entered. Load Factors will be applied for calculations
Loads on all spans...
Uniform Load on ALL spans
DES'GIV SUMMARY
Maximum Bending Stress Ratio
Section used for this span
Load Combination
Location of maximum on span =
Span # where maximum occurs =
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
D = 0,0170, S = 0.0250 ksf, Tributary Width = 4.20 ft
0.084 1
6x12
87.46psi
1 ,035.00 psi
+D+S
3.165ft
Span # 1
[\4aximum Shear Stress Ratio
Section used for this span
W
0'045 : 'l
6x12
9.28 psi
207.00 psi
+D+S
5.383 ft- Snan#1
Q.QQ!, i6 Ratio =
0.000 in Ratio =
o.oo6 in Rutio =
0.000 in Ratio =
Load Combination
Location of maximum on span =
Span # where maximum occurs =
222A5>=360
, <360
1321V >=240
a <240
Maximum Forces & Stresses for Load Combinations
[\,4ax Stress Ratios lVloment Values Sqear VatuesLoad Combination
Segment Length SPan #M V C6 Crnr C; Cr Cm Ct CL lV fb V fv -F'v
D Only
Length = 6.330 ft 'l 0.044 0.023
+D+S
Length = 6.330 ft 1 0.084 0.045
+D+0.750S
Length = 6.330 ft 1 0.072 0.038
+0.60D
Length = 6.330 ft I 0.015 0.008
Overall Maximum Deflections
0.90
1.15
1.15
1.60
1.000
1.000
1.000
1"000
1.000
1.000
1.000
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.36
O.BB
0.75
0.21
Q.00 --0.16
-0.0F -
o.-Jq -
0.00
0.33
0.00
0.1 0
.00
.00
.00
.00
.00
.00
.00
00
00
00
00
00
. - 0.00
35.40 -810C0
0.00
87.46 1035.00
0.00
74.44 1035.00
0.00
21 .24 1440.00
0.00 0.Q0
3.76- -1q'_00
0.00 - 0.c0
s.28 ,O7.OO0.00 0.00
7.90 207.000.00 0.00
2.25 288.00
Load Combination Span [/lax. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
0.000+D+S 0.0057 J. too 0.0000
33/ 42
Wood Beam Build:12. 19.8.31SoftwareINC.
I
1
1
1
1
1
1
1
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon97402
541-357-5532
0
0
DESCRIPTIO 8103 - front patio
Vertical Reactions Support notation : Far left is #'Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum
Overall MlNimum
D Only
+D+S
+D+0.750S
+0.60D
S Only
u.556
0.332
0.226
0.558
0.475
0.1 36
0.332
U.5bU
0.332
0.226
0.558
0.475
0.1 36
0.332
34/42
Wood Beam Software copyright ENERCALC, lNC. 1983-2019, Build:12.19.8.31
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon 97402
541-357-5532
0
0
Wood Beam ENERCALC, lNC. 1 983-201 I, Build:'12.19.8.31Software
DESCRIPTIO 8104 - front patio supporting upper floor
CODE REFERENCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set : IBC 2018
Material Properties
Analysis trlethoAllowable Stress Design Fb +
Load CombinatlBC 2018 Fb -
Fc - Prll
Wood Species iLevel Truss Joist Fc - Perp
Wood Grade TimberStrand LSL 1.3E - Beam/Col Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
3.5x7.25
Span = 6.0 ft
'1,700.0 psi
1,700.0 psi
1,400.0 psi
680.0 psi
400.0 psi
1,075.0 psi
E : Arlodulus of Elasti
Ebend- xx 1,300.0ksi
Eminbend - x 660.75ksi
Density 45.010 pcf
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Load for Span Number 1
Uniform Load : D = 0.0'10 ksf, Extent = 0.0 -->> 3.660 ft, Tributary Width = 8.0 ft, (Wall load)
Uniform Load: D = 0.0170, S = 0.0250 ksf, Extent= 0.0 -->> 3.660 ft, TributaryWidth = 8.0 ft, (Roof load)
DES'G'VSUMMARY W
Maximum Bending Stress Ratio =
Section used for this span
=
Load Combination
Location of maximum on span =
Span # where maximum occurs =
Maximum Deflection
lt/ax Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
0.269 1
3.5x7.25
526.72psi
1,955.00psi
+D+S
2.s40ft
Span # 1
0.104 : 1
3.5x7.25
48.01 psi
460.00 psi
+D+S
0.000fr
Span # 1
Maximum Shear Stress Ratio
Section used for this span
0.027 in Ratio =
Q.QQQ in Ratio =
0.057 in nutio =
0.000 in Ratio =
Load Combination
Location of maximum on span =
Span # where maximum occurs =
2629 >=360
i) <360
1264>=240
r'<240
Maximum Forces & Stresses for Load Gombinations
Load Combination
Segment Length SPan #
Max Stress Ratios Moment Values Shear Values- -
M V Cd Crru C; Cr Cm Ct CL M fb F'b V- fv - F'v
D Only
Length = 6.0 ft 1 0.179 0.069
+D+S
Length=6.0ft 1 0.269 0.104
+D+0.750S
Length=6.0ft 1 0.237 0.092
+0.60D
Length = 6.0 ft 1 0.060 0.023
Overall Maximum Deflections
900
1.60 1
5
(
.00
.00
.00
.00
.00
.00
.00
.00
.00
.00
.00
.00
00
00
00
00
00
.000
.000
.000
.000
.000
.000
.000
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.70
1.35
1.18
0.42
-0-00
273.49'1530.00
0.00
526.72 1955.00
0.00
463.42 1955.00
0.00
164.09 2720.00
o.oo 0.00--- o.qo
- 0.4?- 24.93- 360.(,0oro- 0.00 ---C'.OO
0.81 48.01 460.000.00 0.00 0.00
0.71 42.24 460.000.00 0.00 0.00
0.25 14.96 640.00
1.00
1.00
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
0.000+D+S 0.0569 2.869 0.0000
35/42
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon 97402
541-357-5532
0
Vertical Reactions
8104 - front patio supporting upper
Support notation : Far left is #.Values in KIPS
Load Combination Support 1 Support 2
Oteiellj\,1-Mimum
Overall MlNimum
D Only
+D+S
+D+0.750S
+0.60D
S Only
1.058
0.509
0.549
1.058
0.931
0.330
0.509
o.464
0.223
0.241
0.464
0.409
0.145
0.223
36/42
DESCRIPT!O
Wood Beam Software copyright ENERCALC, lNC. 1 983-201 9, Build: 1 2.'t 9.8.31
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon97402
541-357-5532
0
0
Build:12.1INC.Software
DESCRIPTIO 8105 - back patio
CODE REFERENCES
Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set : IBC 2018
Material Properties
Analysis MethoAllowable Stress Design Fb +
Load CombinatlBC 2018 Fb -
Fc - Prll
Wood Species Douglas Fir-Larch Fc - Perp
Wood Grade No.2 Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsional buckling
1
900 psi
900 psi
350 psi
625 psi
1 80 psi
575 psi
E : Modulus of Elasti
Ebend- xx 1600ksi
Eminbend - x 580ksi
Density
D
4xB
Span = 7.50 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Loads on all spans...
Uniform Load on ALL spans
DES'GN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
Load Combination
Location of maximum on span =
Span # where maximum occurs =
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
D = 0.0170, S = 0.0250 ksf, Tributary Width = 8.0 ft
0.687 I
4x8
924.61psi
1,345.50psi
+D+S
3.750ft
Span # 1
0.302 : 1
4x8
62.52 psi
207.00 psi
+D+S
6.898 ft
Soan # 1
Maximum Shear Stress Ratio
Section used for this span
0.081 in Ratio =
0.000 in Ratio =
0.135 in Ratio =
0.000 in Ratio =
Load Combination
Location of maximum on span =
Span # where maximum occurs =
1117>=360
<360
665 >=240' <240
Maximum Forces & Stresses for Load Combinations
Design OK
Load Combination
Segment Length SPan #
Max Stress Ratros
M
Moment Values
C6 Crru C; Cr Cm Ct CL M fb - F'p V fv F'v
D Only
Length = 7.50 ft 1 0.355 0.156
+D+S
Length = 7.50 ft 1 0.687 0.302
+D+0.750S
Length = 7.50 ft 1 0.585 0.257
+0.60D
Length = 7.50 ft 1 0.120 0.053
Overall Maximum Deflections
0.90
1.15
1.15
1.60
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.300
1.300
'1 .300
1.300
1.300
1.300
1.300
'1 .00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.96
2.36
2.01
0.57
00
00
00
00
,00
.00
00
0,00
374.25 '053-00
0.00
924.61 1345.50
0.00
787.02 1345.50
0.00
224.55 1872.00
0.0q 0.00 o-.80
0.43 25.31 162.00-0.09- 0.00- 0.rr0
1n6 - 62.52 2ut .OO0.00 0.00 0.00
0.90 53.22 207.000.00 0.00 0.00
0.26 15.18 288.00
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
0.000+D+S 0.1 353 3.777 0 .0000
37 /42
Wood Beam
31.21pcf
- - ^
- SnearVitues -
1
WoodChuck Engineering
1 120 Arthur Street
Eugene, Oregon97402
541-357-5532
0
0
DESCRIPTIO 8105 - back patio
Vertical Reactions Support notation : Far left is #'Values in KIPS
Load Combination Support 1 Support 2
OveaelITAXlmum
Overall MlNimum
D Only
+D+S
+D+0.750S
+0.60D
S Only
1.260
0.750
0.510
1.260
1.073
0.306
0.750
1.260
0.750
0.510
1.260
1.073
0.306
0.750
38/42
Wood Beam Build:'12.19.8.31SoftwareINC.
fl?vK r r llls,MEMBER REPORT
Level, J101
1 piece(s) LL 7 lA" TJI@.110 @ 16" OC
O',rerall Lenqth: 11' 5"
I
3'8
All locations are measured from the outside face of left suppoft (or left cantilever end). All dimensions are horizontal.
. Deflection criteria: LL (Ua80) and TL (U2a0).
. Overhang deflection criteria: LL (2V0.2") and TL (2U2a0).
. Top Edge Bacing (Lu): Top compression edge must be braced at 7'4" o/c unless detailed othemise.
. Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 11" o/c unless detailed othemir.
. A structural analysis of the deck has not been performed.
. Deflection analysis is based on composite action with a single layer of 23132" weyerhaeuser Edge'n Panel (24" Span Rating) that is glued and nailed down.
. Additional considerations for the Tl-Pro'" Rating include: None.
Supports
Bearing Length LGds to Supports {lbs)
AccessoriesTotalAvailableRequiredD€d Fl@r Live Total
1 - Stud wall DF s.s0'5.50"3.50',301 458 759 Blocking
2 - Stud wall - DF 3.50'2.25',t.75"-11 2061-50 2061-6r 1 U4" Rim Board
Grry the member being designed.
. Blocking Panels are assumed to carry no loads applied direcuy above them and the full load is applied to the member being designed.
Vetical Loads Lcation (Side)spacing
Dead
(0.e0)
Floor Live
(1.O0)Comments
1 - Uniform (PSF)0 to 11' 5'16"12.0 40.0 Default Load
2 - Point (lb)0 N/A 106
;;
PASSED
System:Flmr
l,lember Type : Joist
Building Us : Residential
Building Code : IBC 2015
Design Methodology : ASD
t,
Design Results AcUIal @ LGtion Allow€d Result LDF L@d: Combination (Pattern)
Member Reaction (lbs)7s9 @ 3'10 3/4'2350 (5.25'.)Passed (32olo)1.00 1.0D+1.01(AllSpans)
Shear (lbs)361 @ 3',8'1560 Passed (23olo)1.00 1.0D+1.01(AllSpans)
Moment (Ft-lbs)-941 @ 3' 10 3/4"3160 Passed (300/o)1.00 1.0D+1.01(AllSpans)
Live Load Defl. (in)0.035 @ 0 0.200 Passed (2V999+)1.0 D + 1.0 1(Alt Spans)
Total Load Defl. (in)0.079 @ 0 0.390 Passed (211999+)1.0D+1.0 1(AltSpans)
Tl-Pro'" Rating 67 50 Passed
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeusr product literature and installation details ?efer t,
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design lcds, dimensions and support information have been provided by ForteWEB Software Operator
A Srirt*^r,,,o*o'*,,*,,*,u,
Ammon Luke
WoodChuck Engineering
(s41) 3s7-3031
ammon@woodchuckengineering.com
Weyerhaeuser
LVsl20t9 8:44:59 PM UTC
ForteWEB v2.1, Engine: V7.3.2.309, Datai V7.2.0.2
rite Namei?d%s
Pane) l)
ForteWEB Software Operator fob Notes
E
Ultimate Loads and Weights of Footings
Bearing Capacity (Assumed) of Soil
q = 1,500 Psf
q= Q
B*L
Uniform Load D Criteria:
Footing Loads
Bridiewood Plan
Eugene, Oregon
B i^t.
D
B in..
24 in.
322 plf
L
B
Client: Bruce Wiechert
Project: 19.298 1.1./6/201,e
40/42
Floor DL 12 psf
Floor LL 40 psf
17 psfRoof DL
25 psfRoof SL
WallDL 12 psf
Strip Footing
North
perimeter
South
perimeter
East
perimeter
West
perimeter
Garage -
north
perimeter
Garage - east
perimeter
Trib. Areap,,ul =16.3 ft.16.3 ft.3.0 fr.3.0 fr.11.0 rt.3.0 ft.
Trib. Arearno =1.0 ft.3.5 ft.5.0 ft.5.0 fr.
Trib. Areayoln =10.0 fr.3.5 fr.1.51r.1.5 ft.4.0 ft.4.0 ft.
Trib. Areary"11 =17.0 ft.17.0 ft.17.0 fr.17.0 fr.9.0 it.9.0 ft.
Width = B L6 in.16 in.16 in.16 in.16 in.16 in.
Length = L 1.2 in.1,2 in.12 in.12 in.1.2 in.1.2 in.
Depth= D B in.B in.B in.B in.B i^t.
24 in.2* in.Stem Wall
Heieht [in.l
24 in.24 in.24 in.
Bin B in.I i4,Stem Wall
Width tin.l B in.8 in.
QF'oottng 322 plf 322 plf 322 plf 322 plf 322 ilf
Qr.r-ing 1,247 plf 1,,079 plf 593 plf 593 plf 6O-pli 3B3plf
Qtorut 1,569 plf 1,401plf 915 plf 915 plf 991 plf 705 plf
Qallo-abte 2,000 plf 2,000 plf 2,000 plf 2,000 plf 2,000 plf 2,000 plf
WoodChuck Engineering
c'6AFu_rr-L-l-rl
WoodChuck
#^hrr)-[r)
IYeg99.h.rq{
Ultimate Loads and Weights of Footings
Bearing Capaciry (Assumed) of Soil
q = 1,500 Psf
q= Q
B*L
Spread Footing Loads
Bridlewood Plan
Eugene, Oregon
D
L
B
Min. Req'd. Sq.
Dim.
23 in.21, in.21, in.1. L in.1L in.25 in.
Reccomend Sq.
Dim.30 in.24 in.24 in.16 in.16 in.30 in.
1.72tb.',98 lb.
F16r
Footing Schedule
Designation Footing Size Reinforcement
F1,6t 1,6" x 16" x 12" (2) #4 Bars Each Way
F24 24"x24" xB" (3J#4BarsEachWay
F30 30" x 30" x 10" (4) #4 Bars Each Way
Client: Bruce Wiechert
Project: 19.298 t1,/6/201.9
47/42
Spread Footing
H 101 B 101 H103 B 103 8105 Girder truss
DL 2392 1,443 L768 452 510 2465
LL 2069 3024
SL 1930 2600 664 750 3625
5,391Ib.4,467lb.4,368 lb.1,1 16 lb L,260lb.6,090Ib.
Depth = D 10 in.L0 in.10 in.10 in.B in.B in.
Stem Wall Height 24 in.24 in 24 in.24 in
Stem Wall Width B in.B in.B in.B in.
Qrooting 949 lb.677 tb.677 lb.215 lb
Qto,"t 6,340Ib.5,144 lb 5,045Ib.1,331Ib.t,43Zlb.6,8BB Ib
Q"lto*"blu 9,375|b.6,000 lb 6,000 lb.2,667 lb,2,667 tb.9.375 lb
Mark +F16r
WoodChuck Engineering
Q-cuat
F30 F24 F30
Design Method:l allowable Stress Design (ASD)V
Connection T1'perl Lateral loading V
Fastener T1'pe I Laq Screw v
Loading Scenario I Srngle Shear V
Main Member Type Hem-Fir V
Main Member Thickn 5.5 in V
Main Member: Angle ol
Load to Grain hs
Side Member T1'pe V
Side Nlentber Thickn 3.5 in.V
Side Member: Angle
Load to Grain
Whsher Thickness 1/8 in V
Nominal Diameter in V
Length 8in V
Load Duration C-D = 1.6 V
Y
End Grain = 1.0 V
Temperature Factor C-t = 1.0 V
Connection Yield Modes
Im 1604 lbs.
Is 2421 lbs.
II II lbs
IIIm 845 lbs.
IIIs
lbs.IV
. Lag Screw bending yield strength of45000 psi is assumed.
. The Adjusted ASD Capacity is only applicable for lag screws with adequale 'r,ri
distance. edge distance and spacing per NDS chapter ll'
While every ellbrt has been made to insure the accuracy of the infonnation presetrted. and
special etlbrt has been made to assure that the intbrmation ret'lects the state-of:the-art.
neither the American Wood Council nor its members assume any responsibility ti'r anl'
particular design prepared from this on-line Connection Calculatol. Those using this on-hne
Connection Calculator assume all liability fi'om its use.
The Connection Calculator was designed and created by Cameron Knudson. Mict.r.e.
Dodson and David Pollock at Washington State University. Support fbr developrne,rt ol'the
Connection Calculator was provided by Anrcrican \&ixxl Council.
Ad.iusted ASD Capacity lbs.
42/42
Hem-Fir
\1et Service Factor I C_M = 0.7
lltozz tus.
WIECHERT- BRIDLEWOOD
Date:10/10/19LR HEADER
Selecflbn
CondNons
Data
Aftributes
Actual
Critical
Slatus
Ratio
Values
Adjustments
Pt loads:
= 5000
C = 1728
D * 1728
5.118x 12 GLB lrtF-V4 OF/DF Lu r 0.0 Ft
Min Bearing Area R1= 12.6 ina fl!= $.$ ipa
TL Defl
Fb Fv E x Fcl
Uniform TL: 570 = A
3.0
1,0
7.0
R1 = 8200 H2 = 5813
SPAN = 9.5 FI
Unilorm and partial unilorm loads are lbs per lineal ft.
Beam Span
Beam Wt per ft
Bm Wt lncluded
Max Moment
TL Max Defl
s.5 ft
14.94 #
142 #
18523 #
Ll24A
Reaction I TL
Maximum V
Max V (Reduced)
TLActualDefl
8200 #
8200 #
7615 #
L/432
Reaction 2 TL 5813 #
123.00
92.61
OK
75%
61.50
60.12
OK
98%
0.26
0..+8
OK
55%
Base Values
Base Adjusted
2404
24AA
190
190
1.8
't.8
650
650
Cv Volume
Cd Duration
Cr Repetilive
Ch $hear $tress
Cm Wet Use
1.000
1.00
't.00
1.00
1.00
1.00
1.00 1.00 1.00
Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0-0
Point TL Distance
Uniform Load A
Dr\
Beamci*ia!ftl;-i-"A",k*;"Aiii; CrAi*bi --- :
E
BeamChek v2.4 ticensed to: Kace Allen Reg # 6464-635
WIECHERT. BRIDLEWOOD
BACK PORCH BEAM Date: 10/10119
Selection
Canditions NDS'91
Min Bearing Area
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Rl= 2.5 in2 R2= 2.5 inz
4xB HF #2 Lu = 0.0 Ft
Beam Span
Beam Wt per ft
Bm Wt lncluded
lVlax Moment
TL Max Defl
8.0 ft
6:t7 #
49#
2049',#
L/240
Reaction 1 TL
Nlaximum V
Max V (Reduced)
TL Actual Defl
1025 #
1025#
870 #
L/589
Reaction 2 TL 1025 #
TL Dell
Fb Fv E XM Fcl
Uniform TL: 250 = A
R1 = 1025 R2 = 1025
SPAN = 8 FT
Unilorm and partial uniform loads are lbs per lineal ft.
30,66
22.26
OK
-7nol
25.38
17.40
OK
69%
0.16
0.40
OK
41"/"
Base Values
Base Adiusted
850
1105
75
75
't.3
1.3
405
405
CF Size Factor
Cd Duration
Cr Repetitive
Ch Shear Stress
Cm Wet Use
'1.300
1.00
1.00
1.00
1.00
1.00
1.00 1.00 1.00
Cl Stability '1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform Load A
BeamChek v2.4 licensed to: Kace Allen Reg # 6464-635
wiechert- bridlewood
entrylliving rm beam Date: 10/10119
Selection
Conditions NDS'91
Min Bearing Area
Data
Attributes
Actual
Crilical
Status
Batio
Values
Adiustments
Loads
R1 = 524
R1= 1.3 in2 R2= 1.3 in2
Fv
4x12 HF #2 Lu = 0.0 Ft
Beam Span
Beam Wt per ft
Bm Wt lncluded
Max Moment
TL lvlax Defl
5.0 ft
9.57 #
48#
655'#
Lt240
Reaction 1 TL 524 # Reaction 2 TL
Maximum V 524 #
Max V (Reduced) 327 #
TLActual Defl L/ >1000
524 #
Section Shear TL De{l
Fb E x mil Fcl
Uni{orm TL: 200 = A
SPAN = 5 FT
Uniform and partial uni{orm loads are lbs per lineal ft
R2 = 524
73.83
8.41
OK
11"/o
39.38
6.55
OK
17Yo
0.01
0.25
OK
ao/
Base Values 850 75
75
1.3
1.3
405
405BaseAdjusted 935
CF Size Factor
Cd Duration
Cr Repetitive
Ch Shear Stress
Cm Wet Use
1 .100
1.00
1.00
1.00
"t.00
1.00
1.00 1.00 1 .00
Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform Load A
il, r\, ra r E lll&itr
System : Floor
Member Type : Jolst
Buikling U'e : Residential
Building Cod€ : IBC 2015
Design t{ehodology : ASD
UEUBER REP4ORT
Level, Floor: loist
1 piece{s) LrT la'TJI@ 110 @ 16" oC
Clirall -er6:h: ?' 11'
t-',;
7
E
4
E
L,t
All locations are measured from the outside face oi left support (or left cantilever end). All dimensions are horizontal.
. Deflection criteria: Lt (u4t,0) and TL (u240).
. Top Edge Bracing {Lu): Top compBion edqE must be braced at 6'6" o/c unless detaihd otheilise.
. Botom Edge Eracing (Lu): Bottom compresss edge must be braced at 9' 9" olc unless detailed otlErwise.
. A stnrtunl arplysis of ttle deck has not been performed.
. Def,ection anabrsis is based m composite action witfi a single la!€r of 23/32' Weyerhaeuser Edge'" Panel (24" Span Ratir€) that is glued and nailed down.
. Additftrnal cmiderations for the TJ-Pro'" Rating inCude: None,
Supports
Loads to Support$ l
AccessoriesTotalAvailableDeadTotal
1 - Stud nall - SPF 3.50"2.25',1.75"79 264 343 I 1/4' Rirn Board
2 - Stud wall - SPF 3.50"2.25',1.75"79 264 143 1 1/4" Rim Board
Rim is assumed to carry all diredy above it, bypassing
Locatior (5ide)
Dead
(0,e0)
Floor Live
(1"oo)Conr ments
1 - Uniform (PSF)0 to 9' 11"16"12.0 40.c DaFault LGd
Design Results Actual @ Location .Allowed Result LDF Led: Combination (Pattem)
Member Reaction (lbs)337 @ 2 712'1041 (2.2s')Passed (32olo)1.00 1.0D+1.01(AllSpans)
Shear (lbs)324 @ 3 712"1560 Passed (21olo)1.00 1.0D+1.01(AllSpans)
Moment (Ft-lbs)782 @ 4'. 7r r/2"3160 Passed (25olo)1.00 1.0D+1.01(AllSpans)
Live Load Defl. (in)0.040 @ 4' lt u2"0.237 Passed (L/999+)1.0D+1.01(AllSpans)
Total Load Defl. (in)0.475 Passed (V999+)1.0 D .r 1.0 L (All Spans)
TJ-Pro'' Ratinq 63 50 Passed
www. weyerhaeuser.com/$,oodproductsldocu rnent{ibrary.
The product application,loads, dimensions and support information have been provided by FortetffE8 Software Operator
- ^l-^
^du e SUSIAINASTE FORESfi'/ I NIIIAIM
'rif4etraiuier
1O/t012019 7:45:17 PM UrC
FofteWEB v2.1, Engine: V7.3.2.309, Data: V7.2.0.2
File Name: wiecheft-bridlewood
PanAl /1
Knce Allen
Kace Allen Oesjgns(fil) s05-1532
kace@kaceallendesigns-com
Fo; tewEB Software Otlerator Not€s
Bearing Length
Required Floor LiYe
Vertical Load spacing
It I MEMBEN RTPORT
Level, Floor: loist
1 piece(s) LL718" TJI@ 110 @ 16" OC
C,,erall :erglh: 11' [-'
System : Roor
MemberTlpe ; Joist
Building Use : Residential
Building Code : IBC 2015
D6ign l4ethodology : ASD
+
0;
t3
V
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
. Defltrtim criteria: LL (Va80) aftd TL (U2a0).
. OverharE deflecuon crit€ria; LL {2V0.2") and TL (21/240).
. Top Edge Bracing (Lu): TopemprGsim edge mst be braced at 7'4" o/c unless detailed otheruise.
. Bottom &9e BGcing (Lu): Sottom comFression edge must be braced at 7'4" o/c unle5s detail€d otherwise.
. A structural analysis of Ul€ deck has not been Frformed.
. Deflectiom analysis is based on composite actbn vrith a single hyer of 23132" W€yedaeuser Edge" PaBel (24" Span Raung) that is grued ard naihd down.
. Additional cosiderations for ttre Tl-Pro" RatirE indude: None.
Accessories1'otal Available Required Dead Floor LiYe Total
1 - Stud wall - SPF 3.50"2.25't.75"48 2t1/-45 2S9l-46 1 1/4" Rim Board
2 - Stud wall - SPF 3.50"3.50"3.50"136 455 591 Blocking
. Rim Board is assumed carry all loads applied dirsciy above it, bypassing the member being
. Bltrking Panels are assumed to carry no loads applied dir(Uy above theil and the full load is applied to the member being designed.
I
Desiqn Results Actual @ Location Allowed Resutt LDF Load: Combination (Pattern)
Member Reaction (lbs)591 @ 7',8 1/4"1e3s (3.s0")Passed (319o)1.00 1.0D+1.01(AllSpans)
Shear (lbs)302 @ 7'6 U2"7716 Passed (18%)1.00 1.0D+1.01(AllSpans)
Moment (Ft-lbs)-504 @ 7',8 U4"3160 Passed (150/o)1.00 1.0D+1.01(AllSpafls)
Live Load Defl. (in)0.033 @ 1l',6"0.200 Passed (21/999+)1.00+1.01(AltSpans)
Total Load Defl. (in)0.038 @ 11'6"0.381 Passed (21/999+)1.0D+1.01(AltSpans)
Tl-Pro"" Ratinq 67 50 Passed
Vertical Loads Lcation (Side)Spacing
Dead
(0.s0)
Floor Live
( 1.00)
Roof Live
(non-snou 1,25)Comments
1 - Unif0rm (PSF)0 io tl' 6"1b 12 0 40.0
2 - Uniform (PLF)0 NIA 40.0
lat
-E9R-11
'^lanufacturedP:duct-
repg(s.
prgduct application, inBit design lcds, dimssims and support informauon have been ForteWEB Sofhvare Ope€tor
www. weyshaeus€r.com/woodproducts/docu mentiibrary.
F(, teWEB Software OpeGtor Job Notes
Kace Allen
Kace Allen Deigns
(s4r) 505-1532
kace@kaceallefi designs.com
a nsTAff4E fOREsTr,', !$ljru\r]:
lUeyerhaeuser
La/fi/20L9 8:28:26 PM UTc
ForteWEB v2" 1. Engine: W.3.7.309, Data: Y7.2.0.2
File Name: wiechert-bridlewood
Panal /1
fi
tl
Supports
Bearing Length Loads to Supports (lt s)
I Default Lodcl
BeamChek v2.4 licensed to: K.ace Allen Reg # 6464-635
WIECHERT- BRIDLEWOOD
2ND FLOOR BEAM Date: 11101119
Selection
Conditions
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adiustments
Loads
8-314x 12 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Min Bearing Area R1= 8.2 in2 H2= 8.2 ine
Beam Span
Beam Wt per It
Bm Wt lncluded
Max lvloment
TL tt/ax Defl
20.25 tl.
25.52 #
517 #
26937',#
L1240
Reaction 1 TL
Maximum V
Max V (Reduced)
TL Actual Defl
5321 #
5321 #
4795 #
L1278
Reaction 2 TL 5321 #
Section Shear TL Defl
Fb Fv E ix Fcl
Uniform TL: 500 = A
Rl = 5321 R2 = 5321
SPAN = 20.25 FT
Uniform and partial uniform loads are lbs per lineal ft.
210.00
141 .57
OK
67%
105.00
37.86
OK
36%
0.88
1.0'l
OK
86%
Base Values
Base Adjusted
2440
2283
190
190
1.8
1.8
650
650
Cv Volume
Cd Duralion
Cr Repetitive
Ch Shear Stress
Cm Wet Use
0.951
1.00
1.00
1.00
'l.00
1.00
1.00 1.00 1.00
ClStabrlity 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform Load A
BeamChek v2.4 licensed to: Kace Atlen Reg # 64G1.035
WIECHERT. BRIDLEWOOD
FRONT DOOR HDR Date:10/10/19
Beam Span
Beam Wt per ft
Bm Wt lncluded
Max lt/oment
TL Max Defl
4.5 ft
6.17 #
28#
1155 '#
Lt 240
Reaction 1 TL 1026 # Reaction 2 TL
Maximum V 1026 #
Max V (Reduced) 751 #
TLActual Defl L/>1000
1026 #
Selection
Conditions NDS'91
Min Bearing Area
Data
Attributes
Actual
Critical
Status
Ratio
Section
Values
Adiustments
Loads
R1 = 1026
R1= 2.5 inz R2= 2.5 inz
4x8 HF #2 Lu = 0.0 Ft
TL Defl
Fb Fv E X
Uniform TL: 450 = A
SPAN = 4.5 FT
Uniform and partial unilorm loads are lbs per lineal lt.
Fcl
R2 = 1026
30.66
12.54
OK
41"/"
25.38
15.02
OK
59%
0.03
0.23
OK
13y"
Base Values
Base Adjusted
850
'1105
75
75
1.3
1.3
405
405
CF Slze Factor
Cd Duration
Cr Bepetitive
Gh Shear Stress
Cm Wet Use
1.300
1.00
1.00
1.00
1.00
1.00
1.00 1.00 1.00
ClStability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Uniform Load A
ffirr 1r,rl r 1;;| tlt;lt !I{EME8&, REPORT
Level, Floor: Flush Beam
1 piece(.g) 3 tlz" x7 ll4" 1.3E TimberStrand@ LSL
'i;rrall .eng:h: ;'
1
System : Fbor
l,lemberTyp€ : Flush Beam
Building Us : Residential
tsuilding Code : IBC 2015
Design Methodology : ASD
;;
l-;tti
I
1',6"
A,l locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal,
. Deflecticn criterb: LL (V,180) and TL (U2.t0).
. Top Edge Bracing (Lu): Top compressiofi edge must be bra€ed at 6 11" o/c untess detaaled othemise.. Eottom EdqE Bracing (Lu): Bottom compressiofl edg€ m6t be braced at 5' 11" o/c ur{ess detailed otheili*.
is assumed to carry lGds treing
l-
POR'H BEAM
Design Results Actual 6) Location Allowed Result LDF LGd: Combination (Pattern)
Member Reaction (lbs)453 @ 6' 11"3347 (2.25")Passed (14oi;,)1.0D+1.01(AliSpans)
Shear (lbs)442 G) 6'5"5950 Passed (7olo)1.00 1.0D+1.01(AllSpans)
Moment (Ft-lbs)1147 @ 3'8"4550 Passed (25olo)1.00 1.0D+1.01(AllSpans)
Live Load Defl. (in)0.046 @ 3',8"0.169 Passed (U999+)l.0D+1.01(AllSpans)
Total Load Defl. (in)0.064 @ 3',8'0.338 Passed (L/999+)1.0 D + 1.0 1(All Spans)
Supports
Bsring Length L6ds to Supports (lbs)
Accessori6TotalAvailableRequiredDeadFloor Live Total
1 - Shrd wall - SPF 3.50',2.25"1.s0"126 315 441 1 L/4" Rim Board
2 - Stud wall - SPF 1.50'2.25"1.50"130 328 458 1 1/4" Rim Board
Vertical Loads Location (Side)Trit utary Width
Floor Live
(1.0o)Comm€nts
0 - Self Weight (PtF)I 114" to 6' 11 314"NIA 7.4
1 - Uniform (PSF)0 to 7' 1" (Front)12.0 40.0 Default L@d
2 - Point 0b)3'8" (Top)N/A 120 350
ResultAllowedTapered End Heel Height Cut Length Cut Slope
Right End 3 3t4"10 r/2"4112 6' 3 3/4"-4,t2 5950 Passd (7S,)
Vrleyerhaeuser Notes
m.weyerhaeuser.om/wmdtrod(tsldocument-li brary......
The goduct apdication, ingjt desrgn loads, dirn€nsiof,s ard support informatim h3ve been poided by ForteWEB Software Ope€t$
Fo:i€WEB Software Operator fob Notes
Kace Allen
Kace Allen Designs
(s4r) s05-153?
kace@kacealhndesqns.com
ST]STAINAEE F@ESIRY :,ITIT',{
l\tyerhaeuser
10/10/2019 B:15:35 PM UTC
FofteWEB v2.1, Englne: V7.3.2.309, Data: V7.2.0.2
File Name: wiechert-bridlewood
A
D*d
(0.eo)
l.'
Shear (lbs)
Locati0n Actual
BeamChek v2.4 licensed ta: Kace Allen Reg # 6464-6Ss
wiechert- bridlewood
porch beam 2
Selection
Date; 10/10/19
4xB HF #2 Lu = 0.0 Ft
Conditions NDS'91
Min Beari
Data
Attributes
Actual
Critical
Slatus
Ratio
Values
Adjustments
Area Rl= 1.7 inz R2= 1 .2 inz
Shear TL Defl
Fb Fv E x Fcl
Beam Span
Beam Wt per ft
Bm Wt lncluded
Irrlax lvloment
TL Max Defl
6.5 ft
4.68 #
30#
1073 '#
L/240
Reaction 1 TL
Maximum V
Max V (Reduced)
TL Actual Defl
687 #
687 #
639 #
L/550
Reaction 2 TL
17.65
11.65
OK
66%
19.25
12.79
OK
66%
0.14
0.33
OK
44%
Base Values 850
1105
75
75
1.3
1.3
405
405BaseAdjusted
CF Size Factor
Cd Duration
Cr Repetitive
Ch Shear Stress
Cm Wet Use
1.300
1.00
1.00
1.00
1.00
1"00
1.00 100 1,00
Cl Stability 1.0000 Bb = 0.00 Le = 0.00 Ft Kbe : 0.0
Point TL Distance
Uniform TL: 100 = A
B=480 1.8
SPAN = 6.5 FT
Uniform and partial uni{orm loads are lbs per lineal ft.
Pt loads
R] = 687 R2 = 473
Uniform Load A
B
BoamChek v2.4 lbenseil ta: Kace Allen Reg # 6464-635
wiechert- bridlewood
porch beam 3
Selection
Date: .10110119
4x 6 HF#2 Lu : 0.0 Ft
Conditions NDS'91
f\Iin Bearing Area
0ata
Aftributes
Actual
Critical
Status
Hatio
Rl= 1.2 in2 R2= 0.7 ina
Shear TL De{l
Fb Fv E X
Unifornr TL: 40 = A
= 480 1.8
SPAN = 6.5 FT
Uniform and partial uniform loads are lbs per lineal ft.
Fcl
Values
Adiustments
Pt loads
Rl - 492 n2 - 2V8
Beam Span
Beam Wt per ft
Bm Wt Included
iltlax l\itoment
TL ftrlax Deil
6.5 fr
4.68 #
30#
817'#
L/24CI
Heaction 1 TL
lVlaximum V
Max V {Reduced)
TL Actual Defi
492# Reaclion 2 TL
492 #
472 #
1t753
278 #
I /.OJ
8.87
OK
50"k
19.25
9.44
OK
49%
0.10
0.33
OK
32,k
Base Values
Base A{usted
850
'1105
7c:
AE
'1.3
1.3
405
405
CF Size Factor
Cd Duration
Cr Flepetitive
Ch Shear Stress
Cm Wet Use
1.300
1.00
1.00
1,00
1.00
1.00
1"00 1.00 1.00
ClStability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe : 0.0
Point TL Distance
Unitorrn Load A
D
Section
BeamChek v2 4licensed to: Kace Allen Reg # 6464-635
wieche( - bridlewood
porch beam 4
Selection
Date:10/1O/19
4x6 HF#2 Lu = 0.0 Ft
Data
Conditions NDS'91
Min Bearing Area
Attributes
Actual
Critical
Status
Ratio
Section
Values
Adjustments
R1= 1.0 in2 R2= 1.'l in2
Shear TL Defl
Fb Fv E X Fcl
Beam Span
Beam Wt per ft
Bm Wt lncluded
Max lr/oment
TL tvtax Defl
6.5 ft
4.68 #
30#
1052 ',#
Lt240
Reaction 1 TL
lVaximum V
Max V (Reduced)
TL Actual Deil
387# Reaction2TL
461 #
435 #
L/611
461 #
17.65
11 .43
OK
65Y"
19.25
8.70
OK
45/"
0.1 3
0.33
OK
39%
Base Values
Base Adjusted
850
't105
75
75
1.3
1.3
405
405
CF Size Factor
Cd Duration
Cr Repetitive
Ch Shear Stress
Cm Wet Use
1.300
1.00
1.00
1.00
1.00
1.00
1.00 1 .00 1.00
ClStability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0
Point TL Distance
Uniform TL: 52 = A
B=480 3.75
SPAN = 6.5 FT
Uniform and partial uniform loads are lbs per lineal tt.
Pt loads:
R1 = 367 R2 - 461
Uniform Load A
B
,Ji F&&rFt"Iru f, E Ld.3i MgM&C$r WXv*Wt
Level, Flmr: Flush Bearn
I pie@s) 3 ll!" x ?" 1.88 Parallann& F$L
f,rrerail Length; f:' ?"
A,l locatiDns are mea$ured trsrn lhe outside face of lefi- silpport (or left cantilever end), Arll dimcnsions sre honeontsl.
{ sEflcction siteria; tL (V480) and TL (U240}.
. Top EdSe Braring {Lu}: Top ctrnpr€ssiofi edgE tfiusl ba l,acd at 6 5' o/c rrdess det&il€d otheeise.
. Bottorn fdge Eracing (Lu): 8oeofir csnFresisn edge must be bruoed at 6'5" {}lt uilh5:s detsiM othe&iss-
{anY
f{iltewEa Sofinjere Oserabr ,ob l{oe$
Kaae ASen
l(ace AU€n Dest ns
(54O 505-153?
|(ace@ka{eaileDdesigns,corr
*
!9
pa\qFx;
System l Root
f,4ember Type : ftush Bean
Building Use : Residentjal
8lilding Code : IBC 2ol5
0esign l*1elio'd$lsgy : ASD
t)
F
&fr.*s.lS] sL:s:irt.r*Lt\"r*:i!5l*Y lFnitdr"rl
1U5/2019 7:??;35 PM UTC
ForteWEB vZ.X, Engine: W,3.2.309, Data: W,?.0.?
File ilame: wiechert-bridlewood
Fagel/1
Mernber Reaction (lbs)100L @ 2"jJat tt,z) I Passed {30%)1.0 O + 1.0 Lr {All spans}
986 @ 10 112',4696 Passed (21%)L<1,0 0 + 1.0 tr {All Spans}Shear {lbs}
Mornent {Ft-lbs}1481 @ z',2 ry16'7qn1 Fassed (19V0)1.8 S * 1.0 Lr {All $pans)
Uve Load Defl. (in]0.046 @ 3'1 11/16"0.156 Passed (t"r999+)1.0D+ tr.0k(AltSpans)
Total Load Defl, fin)0.065@3',113/16"U.JIJ Pass€d {U999+l 1.$ D + 1.8 Lr trA{l Spansl
1 - 5&S $,all - SPf
Supports . oy,
1.50'
.AYryry
z.t>
eeqlrtud
: qn'297 r)t ?ffi 1135 t U4'Rirn &ard
59:l. 1#'Rim BoBxd2 - Stud wall - SPF t,50'186 13?374
tfertica! {-trado
0 - Seli We'qirt (PLf)
LHtOn (siOC,,
I I/4" to 6' 5 3/4'
trihetsry lNifldt{r
NIA 7.S
flser Lixe &&ilft,u.s
{nw-$lyi r,1?l !iii1lY
I - Uniform (P5R 0 t! 6'7'{Frunu 1 12.S Default l-0ad
2 - P0int (lb)3'8" {rrotrt}N/A 115
3 - Point (lb)1'8" {Fmnt}filA f&
diresis$and infsmali$ hare bffi p#ided by FortevltEB Sottwe OpeBtorpmdlKt applietion, input dsign
ul
tt
il
,.,1f
:::
,.t.rl.
ili
wq'!r$e{II
Smi&m Rec$lts A{tudl & [e6adon &,lrswdd ,tesrdt ,-sr L$6dr Somlrlna$srl {P&M!}
&@f tr{a tmt
tr}e&d
{srss}
TSE
Engineering
Tri-State Engineering,
12810 NE 178th Street
Suite 218
Woodinville, WA 98072
425.481.6601
lnc.
Re: J1047743
Bruce Wiecherl Custom Homes
The truss drawing(s) referenced below have been prepared by Tri-State Fngineering under my direct supervision
based on the parameters provided by The Truss Company (Eugene).
Pages or sheets covered by this seal: I13017071 thrul130l7085
My license renewal date for the state of Oregon is December 31,2020.
6 IN E
1 1822PE
OREOON
7'1 6'82
October 11.2019
Terry Powell
The seal on these drawings indicate acceptance of professional engineering responsibility solely for the
truss components shown. The suitability and use of this component for any particular building is the
responsibility of the building designer, per ANSI/TPI 1.
1047743 EL-
lr.,.r rvoe-
lcoMMoN
GTRDER
lo', l"', lBruce Wiechert Custom Homes ng'17,l1l,l I 2 lroo*",","n"",o,non,,,
The Truss Company MiTek lnduslries. lnc. Wed Oc1 16 17t49.232019
I D:zezdcWaqVmpfQ lf PZi0YmwySm../G tsCxDxDzYWHn4aT5VTWxipSx_OGd?BUY?
-1 56-15
4x6 ll
"
'18
8x8 =
HUS26
Scale - '1r47 3
I
I
l
l-
eoo lit
4x4 lz
2
4x4 :\
4
IJ
14
HUS26
15 g 17
HUS26
16
gxa ll HUS26
19 7 206 21
HUS26 6x6 = 3x8 ll HUS26
HUS26
HUS26 6*io .-
22
6x10 /z
HUS26 HUS26
oel. t6 0-4-12.0-1-81. t8:0-4-0 0-4-81. l9:O-4-12.0-1 0-3-5, Edqel, 12:0-A-12.0-1 -121. l3:O-2-12.0-2-01,4:O A 12 O 1 121. 15:0-3-5.
SPACING- 2-O-O
Plate Grip DOL '1.'15
Lumber DOL 1 15
Rep Stress lncr NO
Code lRC2015/TPl20'14 Matrix-l/lSH
cst.
TC 087
BC 492
wB 0.63
DEFL.
Vert(LL)
vert(cT)
Hoz(CI)
in (loc) Udefl L/d
-0.15 6-8 >999 360
-0.24 6-8 >999 240
0.08 5 nla nla
5.6-15 10s-0
4-11-1
'15-5,'1
4-11-1 56-15
LOADING (psf)
TCLL 250
(Roof Snow=25.0)
IQDL 8,0
BCLL O.O
PLATES
tvtT20
GRIP
220t195
RENEWS:12t31t20
October 17,2019
LUMBER.
TQP CHORD
BOT CHORD
WEBS
7.O
2x4 DF No.2
2x6 DF 1800F 1 6E
2x4 DF Stud "Except'
3-8: 2x4 DF No.2
BRACING-
TOP CHORD
BOT CHORD
Weight: 229 lb FT = 2Oo/.
Structural wood sheathing directly applied or 3-1-2 oc puriins
Rigid ceiling directly applied or 10-0-0 oc bracing.
OREGON
?It 6182
WEDGE
Left: 2x4 SP No.3 , Right: 2x4 SP No 3
REACTIONS. (lb/size) 1=6707/0-5-8,5=6082/0-5-8
Maxlorz 1=148(LC22)
Max Uprift 1=-865(LC 8), 5=-784(LC 9)
FORCES. (lb) - [rax. Comp./lv]ax. Ten - All forces 250 (lb) or less except when shown.
TOP CHORD 1 -2=-9363h212, 2-3=-6292ta65, 34=-62921865, 4-5= -93Uh21 2
BOT CHORD 1 -9=-10381777 1, 8-9=-1038/7771, 6-8=-94317769, 5$=-94317769WEBS 3-8=-864i6582, 4-8= -32701537 , 4-6=-39013279, 2-8=-32721537 .2-9=-38913275
NOTES-
1 ) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows.
Top chords connected as followsr 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc
Webs connected as follows 2x4 - '1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section Ply to ply connections have been
provided to distribute only loads noted as (F) or (B), unless otheMise indicated.
3) Wnd: ASCE 7-10t Vult=120mph (3-second gust) Vasd=95mph; TCDL=4.8psf; BCDL=4.2psf, h=25ft, Cat. ll, Exp B, Enclosed, IVIWFRS (envelope) gable end
zonet cntilever left and right exposed ; end vertical left and right exposed, Lumber DOL=1.60 plate grip DOL=1 .60
4) TCLL: ASCE 7-10t Pf=25.0 psf (flat roofsnow)i Category ll, Exp B; Partially Exp., Ct=1.10
5) This truss has been designed for a 'l 0.0 psf bottom chord live load nonconcurrent with any other live loads.
6) . This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6,0 tall by 2-0-0 wide will fit between the bottom
chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1 00 lb uplift at joint(s) except 0t=lb) I =865, 5=784
8) Use USP HUS26 (Wth '1 4-1 6d nails into Girder & 6-'1 6d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 0-1 1 -4 from the left end to 18-11-4 lo
connect truss(es) to back face of bottom chord
9) Fill all nail holes where hangeils in contact with lumber.
LOAD CASE(S) Standard
'1) Dead + Snow (balanced) Lumber lncrease='1 15, Plate lncrease=1 15
Uniform Loads (plf)
Vert:'l-3=€6, 3-5=€6, 1-5=-14
Concentrated Loads (lb)
Vert:11=-1111(B)14=-1111(B)15=-1111(B)16=-1111(B)17=-1111(B) 18=-1111(B)19=-1111(B)20=-1111(B)21=1111(B)22=-1111(B)
/fu *rarc*ti - X.*y d6$&s psses*str s$# #i:4, /r$?li:$ tll$ ?litJs ,4ld# ttift###S 6{fi:{ JlrF}IEEecf $i,## tdli'1.d;} ffrr,{s llss.
Design valid for use only wilh l\4iTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of desion paramenters and proper incorporation of component is responsibilily of building designer - not truss designer. Bracing shown
is for tateral supporiof tndividual web members only Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure rs the responsibility of lhe burlding designer For general gurdance reS_qr-dlng_ _. -fabrjcarion. quatiiy controt, storage, dativery, erecrion and bracing, consult ANSUTPII Quilry CdElis, DSB49 8nd BCSI1 Buildlng Componsnt
Saftty lnbmdon available frbm Truss Plate lnstitute 583 D'Onofrio Drive, Madison. Wl 53719.
I
,nrl,&
theTRUS$co.ll.'rc.
Job
r 5$-15 r 10€-0 | 15-5-1 21-0-A
56-15 4-11-1
3
5
Job lTruss
lcrcr
I
lius rype
lonar-r
lo', l"', lBruce wiechert Custom Homes
h | 1 l-
--- t13017072
I I Uob Referen@ (optonal)
1047743
The Truss Company (Eugene), Eugene, OR - 97402,8 320 s Oct I 2019 MiTek lndustries. lnc. Wed Ocl 16
lD:2a\./wni0h0HG!-'!xKD5KKVyUgySnsg'6K8wkC7yR3Gv7LsY 1 nM3N7pimgjg7hvN96xh5rySm[il
214-O
15
Scale = 1:48.9
4\4
I
118
4x47
e.oo lrI
5
3
'18
2iIo
1
I:
25 24 23 22 21
'19
3x6
17
3x4 -
3x4 //
Ilatrix-IVSH
csr.
TC
BC
WB
031
022
009
DEFL.
Vert(LL)
Vert(CT)
Hoz(CT)
in (loc)
-oo2 18-24
-0.04 18-280.01 16
l/defl
>999
>999
nla
L/d
360
240
nla
SPACTNG- 2-O-0
Plate Grip DOL 1 15
Lumber DOL 1 15
Rep Stress lncr YES
Code lRC2015/TP12014
1 5-0-8
LOADING (psf)
TCLL 25.0
(Roof Snw=25.0)
TQDL 8,0
BCLL O,O
BCDL 7.O
LUMBER.
TQP CHORD
BOT CHORD
WEBS
OTHERS
PLATES
t\rT20
GRIP
220t195
2x4 DF No.2
2x4 DF No 2
2x4 DF Stud
2x4 DF Stud
BRACING-
TOP CHORD
BOT CHORD
JOINTS
Weight 131 lb FT = 20ak
Structural wood sheathing directly applied or 6-0-0 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
'1 Brace at Jt(s): 12
REACflONS. All bearings 96-8 except (jt=length) 16=0-5-8.
(lb) - irax Horz 2=-176(LC 6)
Max Uplift All uplift 1 OO lb or less at loint(s) 20, 21, 22, 23, 24, 25. 2 e\cepl 16=-1 08(LC 9)
Maxcrav Allreactions25Olborlessatjoint(s)2'1,22,23,24,25except16=642(LCl),20=526(LC1),20=526(LC1),2=329(LCl),
2=329(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOPCHORD 15-16=$1On2.1O-2O=465t145,10-12=-463/166,12-14=4341149,14'15=4171138
BOTCHORD 18-20=01430,'16-18=0/430
NOTES.
1)Wind:ASCE7-10;Vult='l2Omph(3-secondgust)Vasd=95mph;TCDL=4.8psf;BCDL=4.2psf,h=25ft;Cat.ll ExpB,Enclosed,IVIWFRS(envelope)gableend
zone; cantilever left and right exposed , end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1 60
2)Trussdesignedforwindloadsintheplaneofthetrussonly. Forstudsexposedtowind(nomaltotheface),seeStandardlndustryGableEndDetailsas
applicable, or consult qualified building designer as per ANSI/TPl 1.
3) TCLL: ASCE 7-10, Pf=25 0 psf (flat roof snow) Category il, Exp B, Partially Exp., Q1=1 16
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat r@f load of 25 0 psf on overhangs non{oncurrent wlth other live
loads
5) All plates are 1 5x4 MT20 unless otheMise indi€ted
6) Gable studs spaced at 1 -4-0 oc
7) This truss has been designed for a 10.0 psl bottom chord live load nonconcurent with any other live loads
8) . This truss has been designed for a live load of 2o.Opsf on the bottom chord in all areas where a rstangle 36-0 tall by 2-0-0 wide will fit betlveen the bottom
chord and any other members.
g) Provide mechanicl connection (by others) of truss to bearing plate capable of withstanding 1 00 lb uplift at joint(s) 20,21 ,22, 23,24, 25,2,2 except 0t=lb)
16=1 08.
1 O) Graphi€l purlin representation does not deprct the size or the orientation of the purlin along the top and/or bottom chord.
RENEWS:12t31t20
October 17,2019
OfiEGON
ill6t82
I WaANWe - Vnig d6t$ papi,*ft *d READ NOrES ON TU(S AND ltlCLUA€D MITEK R€F€RENCE PAOE Mlp74n AEFOR€ L]98.
Design valid for use onty with MiTek conneclors This desagn is based only upon paramelers shown, and is for an individual building componenl
Applicability of design piramenters and proper incorporation of componenl is responsibility of building designer - nol kuss designer' Bracing shown
is%riaterelsupporiofindividuatwebmembersonly. Additionaltemporarybracinglornsurestabrlilyduflng_construclronrstheresponsibillityolthe
ereclor. Additional permanent bracang of the overail structure is the responsability of the buildmg desrgn-er lor genqal_guidance regarding
tabricaron ouatitvconlrot.sloraoe.c,etrvery erecnonandbractnq,consu[ ANSUTF|IOuafnyCduile,DSB-E9mdBCSllBu{dlngComponent
Salatylnbmistoi avaiiablefr"om T'ussPlatelnstnute 5S3DOnokioDrive liladrson w 5J/19
A
theTRUS$co. ttlc.
4x8 =
20
6
4
Job
lEr cr
I
lTruss
TyOe
lCommon
Supported Gable
lo', 1",, iaiuceffi1 | 11 113017073
I l-oo n"r"rence (oouolat)
)1047743
(Eugene), Eugene, OR - 97402,8 320 s Ocl 9 2019 MiTek ndustries. nc. Wed Oct'16 17 49:262019
ID
5-1 1 -8
17
13-1 '1-0
Scale = 1:30 1
4x4
eoo Fz 84
I
10
J
2 T\
Y
1118151413123x4 \\
11-11-0
3x4 /z
11 -11 -O
LOADING (psf)
TCLL 25.0
(Roof Snow=25.0)
IQDL 8.0
BCLL O,O
BCDL 7.O
LUMBER-
TQPCHORD 2x4DFNo.2
BOI CHORD 2x4 DF No.2
OfHERS 2x4 DF Stud
PLATES
tvtT20
GRIP
220t195
BRACING-
TOP CHORD
BOT CHORD
Weight: 64 lb FT = 20%
Structural wood sheathing directly applied or 6-0-0 oc purlins.
Rigid ceiling directly applied or 1 0-0-0 oc bracing.
REACTIONS. All bearings'11-'11-0.
(lb) - lrax Horz 2=-112(LC 6)
lrax Uplift All uplift 100 lb or less at joint(s) 2, 10, 16, 17, 18, 14, 13, 12
lvaxGrav All reactions250 lborlessatjoin(s)15, 16,17,1A.M,13,12ex@pt2=291(LC1), 10=291(LC1)
FORCES. 0b) - NIax Comp /lvax. Ten - All forces 250 (lb) or less except when shown
NOTES.
1)Wnd:ASCE7-10;Vult='l20mph(3-secondgust)Vasd=gsmph,TCDL=48psf;BCDL=4.2psf,h=25ft,Cat ll,ExpB;Enclosed,MWFRS(envelope)gableend
zonet €ntilever left and right exposed , end vertical left and right exposed, Lumber DOL=1.60 plate grip DOL=1 60
2)Trussdesignedforwindloadsintheplaneofthetrussonly. Forstudsexposedtowind(normaltotheface),seeStandardlndustryGableEndDetailsas
applicable, or consult qualified building designer as per ANSI/TPl 1.
3) TCLL: ASCE 7-10, Pf=25.0 psf(flat roofsnow); Category ll, Exp B, Partially Exp; Ct=1.'10
4) This truss has been designed for greater oi min roof live load of 16 0 psf or 1 00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live
loads.
5) All plates are '1.5x4 MT20 unless otheruise indi€ted
6) Gable requires 6ntinuous bottom chord bearing
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 1 0.0 psf bottom chord live load nonconcurrent with any other live loads
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom
chord and any other members.
1 0) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1 00 lb uplift at joint(s) 2, 10, 16 17 , 18, 1 4, 13 12.
RENEWS: 12131120
October 17,2019
.0-'l -81. I10:0-2-0 0-1-
SPAC|NG- 2-O-O
Plate Grip DOL 1.15
LumberDOL '1.15
Rep Stress lncr YES
Code lRC2015/TP12014
cst.
TC
BC
WB
[y'atrix-SH
0.14
003
DEFL.
Vert(LL)
Vert(CT)
Hoz(CT)
in
o.o2
0.01
000
(loc)
11
11
10
l/defl Ud
nlt 120
nlr 90
nla nla
7t16t82
3fu iylmliN*-*nryds$&r$6lwss&r$,fillidrl#${}*}}}iJ#A$r:$,lt:;#Lil€*r\4n*;{S$firr?rrYf*i{A$S&llt}"{l3$$Sftrf?J$g.
Design valid for use only with MaTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of componeni is responsibilily of building designer - not truss designer. Bracing show!
is for lateral supporaof individual web members only Additional temporary bracing to insure stability during conslruction ls the responsibillity of the
erector. Additional permanent bracing of the overall stuctu re is the responsibility of lhe bul]qrng qeiig lgr For gentra I guidance regarding
fabrication, quatity controt, storage, d;livery. erection and bracing, consult ANSUTPI1 Quilily Cttleds, DSB{9 sd BCSI1 Bullding Component
Sahty lnbmatbir available frcm Truss Plate lnstitute 583 D'Onofrio Drive, Madison, wl 53719.
AA
theTRUS$co" ruc.
7
5
3
1047743
ITL=
llruss lype
lcorron Supported Gable
I
lo'' lt', lBruce Wiechert Custom HomesIr | 11 113017074
| | lJob Referene ropnonarrCompany(Eugene), Eugene,lnc. Wed Oct 16 17:45:07 2019
'14-3-0
4x4 Scale = 1:62.7
12
11 13
10 14
9
'16I
15
eoo lit
'17
6
43 42 41 40 39 38 37 36 35 u 33 g2 31 3ozg
JXb -
18
19
4 2A
3 21
22N{o1
N
T+
3x4 /z 3x428 27 26 25 24
28S-0
286-0
LoADING (psO
TCLL 25.O
(Roof Snow=25.0)
rcDL 8.0
BCLL O,O
BCDL 7.0
PLATES
[/T20
GRIP
220t195
Weight: 224 lb FI = 20%
LUMBER.
IqP CHORD 2x4 DF No.2
BOT CHORD 2x4 DF No.2
OTHERS 2x4 DF Stud "Except*
1 2-34, 1'1 -35, 1 0-36, 1 3-33,1 4-32: 2x4 DF No.2
BRACING-
TOP CHORD
BOT CHORD
WEBS
Structural wood sheathing directly applied or 6-0-0 oc purlins
Rigid ceiling directly applied or 1 0-0-0 oc bracing.
1 Row at midpt 12-34, I 1-35, 13-33
REACTIONS. All beanngs 28-6-0.
(lb) - Max Horz 2=228(LC7)
MaxUplift Allupliftl00lborlessatjoint(s)22,34,35,36,37,38,39,40,41,42,43,33,32,30.29,28,27.26,25,24,2
Max Grav All reactions 250 lb or less at join(s) 34, 35, 36, 37, 38, 39, 40, 41, 42, 43.33,32, 30,29, 28,27, 26,25, 24 excepl
22=29o(LC 1), 2=290(LC 1 )
FORCES. (lb) - Max. Comp./Vlax. Ten - All forces 250 (lb) or less except when shown.
NOTES-
1) Wnd: ASCE 7-10, Vult=120mph (3-second gust) Vasd=95mph, TCDL=4.8psf, BCDL=4.2psf: h=25ft; Cat. ll; Exp B; Enclosed; MWFRS (envelope) gable end
zone, cantilever lett and nght exposed , end vertical left and right exposed, Lumber DOL='I.60 plate grip DOL=1.60
2) Trussdesignedforwindloadsintheplaneofthetrussonly. Forstudsexposedtowind(nomal totheface),seeStandardlndustryGableEndDetailsas
applicable, or consult qualifled building designer as per ANSI/TPl 1
3) TCLL: ASCE 7-10; ff=25.0 psf (flat roof snow); Category ll; Exp B; Partially Exp , g1=1 1g
4) This truss has been designed for greater of min roof live load of 1 6.0 psf or '1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live
loads
5) All plates are 1 5x4 [ilT20 unless otheruise indi€ted
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 1 -4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads.
9) . This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will flt between the bottom
chord and any other members.
1 0) Provide mechanical connection (by others) of truss to bearing plate €pable of withstanding 1 00 I b uplift at joint(s) 22, 34. 35, 36, 37, 38, 39, 40, 4 1 , 42, 43, 33,
32, s0, 29, 28, 27, 26, 25. 24, 2.
RENEWS:12t31t2a
October 17,2019
OREGON
7'1 6'82
3S lv*;tx'iscrs-l'**&&&eSs#ffi$s##*d#iit*&sls${iq:}1,$,{$Sitl#t#r}t#3,rr}f{f;s{s$#ti##ri{##3dii-L?rr$*:l###itif-
Design valid for use on y with MiTek connectors Thls deslgn is based only upon parameters shown and is for an individual building component
Applicability of design paramenters and p.oper incorporation of component is responsibility of building designer - not russ designer Bracing shown
s for lateral suppor[of ndividual web members only Additional temporary bracing to insure stability during conslruction is the responsibillity of the
erector.AdditionalpermanentbracingoftheoverallstructureistheresponsibilityofthebuitdingdesignerForgensal_guidanceJgs_Cr-d]]19..- _
fabricarion, quatiry controt, storage, dativery, erection and bracrng, consult ANSUTPII Ousliry Cdteris, DSB{g and BCSI1 Building Componenl
Sabty Inhmat'Dn available from Truss Plate lnstitute, 583 D'Onofrio Drive, [,4ad]son, Wl 53719
Aa
the?RUS5co.lxc"
Job
286 0 , 306-0 ,14-3-0 -14-3-0
7
5
2
lvlatrix-SH
csr.
TC 026
BC 0.14
WB O08
DEFL.
Vert(LL)
Vert(CT)
Hoz(CT)
in (loc) Udefl L/d
OO2 23 nlr 12O
0 0'l 23 nh 90
0.01 22 nla nla
SPAC|NG- 2-O-O
Plate Grip DOL '1 15
Lumber DOL 1.15
Rep Stress lncr YES
Code lRC2015/TPl20'14
Job
H
Truss Type
]corro,
lotvIJl047743
Plv lBruce Wiechert Custom Homes
I 113017075
lJob Reference {ootronall
1
The Truss Company (Eugene), Eugene, OR -
I D 2:\./wni0h0HgHxKD5KKVyUgysnsg-pzDHGo'1 Z4wOvnHqCTpkPbe'l RLLDT
-2-O-O
2-A-0
2
2A$-A 306-0
6
7 -3-15
aoo FI
Scale = 1:65 14x5 ll
4
N
do.
1 5x4 \\
17 18
1.5x4 //
5
21 22
N
_r+/o
10
3x4 =
2098
3x4 :
19
3x5 \
3x5 /z
9-7-10 9-2-12 9-7-10
LOADING (psf)
TCLL 25.O
(Roof Snow=25 0)
TQDL 8,0
BCLL O.O
BCDL 7.0
PLATES
l./tT20
GRIP
220t195
Weight: 134 lb Ff = 20%
LUMBER-
rQP CHORD 2x4 DF No.2
BOT CHORD 2x4 DF No.2
WEBS 2x4 DF No.2 tExcept.
5-8,3-'10: 2x4 DF Stud
BRACING-
TOP CHORD
BOT CHORD
Structural wood shealhing directly applied or 4-2-4 oc purlins.
Rigid ceiling directly applied or 1 0-0-0 oc bracing.
REACTIONS. (tblstze) 2=127210-5-8, 6=127210-5-8
Max Hotz 2=22a(LC 7)
Max Uplift 2=-178(LC 8), 6=-178(LC 9)
FORCES. (lb) - liax Comp /Max. Ten. - All forces 250 (lb) or less except when shown
TOP CHOR D 2-3= -1 6a1 t2o5, 3-4= -1 538 127 5. 4-5= -1 538t27 5. 5-6=-1 68'l /205
BOT CHORD 2-10=-19311472. 8-10=-15/950, 6-8=-67/1332
WEBS 4-A=-162fi56,5-A=-4421245,4-10=-1621756,3-10=-442445
NOTES-
'1) Wnd: ASCE 7-10; Vult=12omph (3-second gust) Vasd=95mph; TCDL=4.8psf, BCDL=4.2psf; h=2sft Cat ll, Exp B; Enclosed; MWFRS (envelope) gable end
zone; €ntilever left and right exposed , end vertical left and right exposed; Lumber DOL= 1 .60 plate gnp DOL=1.60
2)TCLL: ASCET-'10; Pf=25.0psf (flatroof snow),Categoryll; ExpB,PartiallyExp.; Ct=1 '10
3) This truss has been designed for greater of min roof live load of 1 6.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live
loads
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) 'This truss has been designed for a live load oi 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will flt between the bottom
chord and any other members, with BCDL = 7 opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1 00 lb uplift at joint(s) except (]t=lb) 2='1 78, 6=1 78.
OftEGON
7t16t82
RENEWS: 'tzt31t20
October 17,2019
3S lV*;,W1ru: " ys*ri. r{s&r feede&r5 6ad #e4# id{}iS$ #S ?r{JS ntr# ,ld#i&SSS &9iv$g l$iSlllltiii{## pd *g &$r,-74V5 AX$*A€ t"}SE.
Design valid for use only with MiTek connectors This design is based only upon parameters shown, and is for an individual building component
Applicability of design paramenters and proper incorporation of component is responsibil[y of building designer - not russ designer. Bracing shown
sforlateraisuppor[ofindividualwebmembersonly. Additionaltemporarybracingtoinsurestabilityduringconstructionistheresponsibillityofthe
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer For gentral guidance regarding
id b, c ano. ouatrlv contror. sior aqe detrvery e, ecnon ano oracrnq cor su lt ANSUTPI1 Ouallry CdEIls, DSB{9 8nd BCSI1 Buildlng Componsnt
Sabtylnbmathn avarlablefrbm lrussplatel^slrlLle 58JD'0nofiroDrrve lMadrson Wl 53/'9.
IA
theTRUSSco.tNc"
3
SPACTNG- 2-O-0
Plate Grip DOL 1 15
Lumber DOL 1.15
Rep Stress lncr YES
Code lRC2015/TP12014 lMatrix-[4SH
cst.
TC
BC
WB
0.58
0.68
0.29
in (loc)
-0.24 8-10
-0.31 8-10
0.04 6
l/defl
>999
>999
nla
Ltd
360
240
nla
DEFL.
Vert(LL)
Vert(CI)
Hoz(CT)
Job
Ie
lTruss
ryoe
lCommon ruJ1047743
Plv ce Wiechert Custom Homes
1 t'13017076
| -2-0-o 7 -3-15 1 4-3-0
8.320 s oct I 2019 MiTek lndustries, lnc. Wed Oct 16 17:49:09 2019 Page 1
I D:zezdcWaqVmpfQlfPZi0YmwySmvG-lAnfTS2BrDWmP0PPhWCel sZcT lZjvrKUnAUNtBySmMO
| 21-2-1 t 2a-2-14
6-11 1
1.5x4 //
5
19 8 7 20 21
7-O-13
4x5
18
5x53x6
JX43x5 /z
Scale:3/16"=1
eoo lz' 1.5x4 \\
3
ts
do1
l.e
'16 17
3x4 =
SPACTNG- 2-O-0
Plate Grip DOL 1.'15
Lumber DOL '1 '15
Rep Stress lncr YES
Code lRC2015/TP12014 M atri x- N,4 S H
csr.
TC 0.58
BC 0.69
WB 0,29
DEFL.
Vert(LL)
Vert(CT)
Hoz(CT)
in
-0.25
0.04
(loc) l/defi L/d
7-9 >999 360
7-9 >999 240
6 n/a nla
28-2-14
9-2-12
LOADING (psf)
TCLL 250
(Roof Snow=25.0)
TQDL 8.0
BCLL O.O
LUMBER-
TQP CHORD
BOT CHORD
WEBS
PLATES
t\,1T20
GRIP
220t195
BRACING.
TOP CHORD
BOT CHORD
Weight: 131 b Fr = 20%
Structural wood sheathing directly applied or 4-2-6 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
2x4 DF No.2
2x4 DF No.2
2x4 DF No.2.Except*
5-7,3-9: 2x4 DF Stud
WEDGE
Right: 2x4 SP No.3
REACTIONS. (lb/size) 6='112sllvlechanical, 2=1266/0-5-8
Max Horz 2=218(LC 5)
Max Uplift 6=-136(LC 9), 2=-178(LC 8)
[Iax Grav 6=1 1 38(LC I 7), 2=1 266(LC 1 )
FORCES. (lb) - Max. Comp /Max Ten. - All forces 250 (lb) or less except when shown
TOP CHOR D 2-3= -1 669 1205, 34= -1 526127 5, 4-5= -1 5O7 t 2ao, 5-6=-1 653/209
BOT CHORD 2-9=-21411447 7-9=-371924. 6 7=-BA|12AO
WEBS 4-7=-1671724.5-7=-4251247,4-9---1621760,3-9=441t245
NOTES.
'l)Wnd:ASCE7-1O,Vult=120mph(3-secondgust)Vasd=95mph,TCDL=4.8psf,BCDL=4.2psf,h=25ftiCat ll;ExpB,Enclosed;IVWFRS(envelope)gableend
zone, mntilever left and right exposed ; end vertical left and right exposed, Lumber DOL=1.60 plate grip DOL=I .60
2) ICLL: ASCE 7-10; Pf=25.0 psf (flat roofsnow), Category ll, Exp B; Partially Exp., Ct=1.10
3) This truss has been designed for greater of min roof live load ol 1 6.0 psf or 1 OO times flat roof load of 25.0 psf on overhangs non-concurrent with other live
loads.
4) This truss has been designed for a 1 0.0 psf bottom chord live load nonconcurrent with any other live loads
5) - This truss has been designed for a live load of 2o.Opsf on the bottom chord in all areas where a rectangle 36-0 tall by 2-0-0 wide will fit between the bottom
chord and any other members, with BCDL = 7 opsl
6) Refer to girde(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1 00 lb uplift at Joint(s) except (jt=lb) 6= 1 36, 2='1 78.
RENEWS:12t31t2o
October 17,2019
7t16t82
dk Wr+eet;,V*,txll.rlB$4is.r,restrard#ilq$lJ6lS$#s:!l$,4&r/dfl.ilgt::{rl5!itftlqflV*#;1d$;:i{lr-Id7:sl:lrl;riJ$S.
Deslgn valid for use only with lvtiTek conneclors. This design is based only upon parameters shown, and is for an lndividual building componenf.
Applicability of design paramenters and proper incorporation of component is responsibilily of buildlng designer nol truss designer Bracing shown
is'for lateral suppon"of individuat web members only. Additional temporary bracing to insure stability during construction is the responsib lLily of the
erector Additional permanent bracing of the overail sfucture is the responsibildy of the burldlng des gner For general guidafce_rgS^qr-dl]S.. .-
tabilcarion. ouatrrv cortrot storaqe oetrverv erecrion and bra( .q, consulr ANSUTPI1 Qutlity CriGda, DSB39 and BCSI1 BuildinO Component
SSfetylnbmSfpn ava,labelr-omTrussdldlellslrlule.5SJD0lo'rroD-ivPvadsonWl 5'l/lq
IA
theT*U$Sco"lxc.
4
2
6
Job II fuSS
I
A4GE
I
lTruss Type
borrnon Suooorted Gablet"
lo', l"', lBruce Wechert Custom Homeslr | 11 113017077
I I lJob Referene (optronat)
J1047743
The Truss Company (Eugene), Eugene, OR
r -2-0{ |14-3-0
E 320 s oct 9 2019 MiTek lndustnes lnc Wed Ocl 16 17:49:11 2019 Page 1
lD:zerdcW:q\,hpfQlfPZi0YmwySmvG-EYvPuq3RNqmUekYnoxlTDHf'l eYM2Bt3nEUzTy4ySmM M
28-2-14
24-O
2
14-3-0 13-11-14
S€le ='1 61.84x4
11 13
'10 14
I 15
a.oo Fz '16
7
186
5
42 41 40 39 38 g7 36 3s 34 33 32 3t go 29 ze
3x6 =
19
4 20
21
22
rg
Nirol
3x4 /z 3x6 |27 26 25 24 23
28-2-14
LOADING (psO
TCLL 25O
(Roof Snow=25.0)
TQDL 8,0
BCLL 0.0 '
LUMBER-
TQP CHORD 2x4 OF No.2
BOT CHORD 2x4 DF No.2
OTHERS 2x4 DF Stud.Except'
12-33,'1 'l -34,10-35,13-32,14-31. 2x4 DF No2
WEDGE
Right: 2x4 DF Stud
PLATES
MT2O
GRIP
2201195
BRACING.
TOP CHORD
BOT CHORD
WEBS
Weight: 220 lb Fr = 20%
Structural wood sheathing directly applied or 6-0-0 oc purlins.
Rigid ceilang directly applied or 10-0-0 oc bracing
lRowatmadpt 12-33,11-34,13-32
REACTIONS. All beanngs 28-2-14.
(lb)- Max Horz 2=219(LC 5)
MaxUplift Allupliftl00lborlessatjoint(s)33,34,35,36,37,38,39,40,41,42,32.31,29,2a,27,26,25,24.23,2,22
MaxGrav Allreactions2S0lborlessatjoint(s)33,34,35,36,37,38,39,40,41,42,32,31,29,24,27.26,25,24,23,22
except 2=291 (LC 1)
FORCES. (lb) - Max Comp./Ma. Ten. - All forGs 250 (lb) or less except when shown.
NOTES-
1)Wind:ASCE7-'10,Vult=120mph(3-secondgust)Vasd=gsmph,TCDL=4.8psf,BCDL=4.2psf;h=25ft;Cat.ll ExpB,Enclosed;MWFRS(envelope)gableend
zone; €ntilever left and right exposed , end vertical left and right exposed, Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only For studs exposed to wind (normal to the face), see Standard I ndustry Gable End Details as
applieble, or consult qualified building designer as per ANSI/TPl 1.
3) TCLL: ASCE 7-10, ff=25 0 psf (llat roof sntr), Category ll, Exp B. Partially Exp.; 61='1 19
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live
loads.
5) All plates are 1.5x4 MT20 unless otheMise indi€ted
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurent with any other live loads.
9) ' This truss has been designed for a live load of 20 opsf on the bottom chord in all areas where a rectangle 3S-0 tall by 2{-0 wide will fit between the bottom
chord and any other members.
1 O) Provide mechani€t connection (by others) of truss to beanng plate epable of withstanding 1 00 lb uplift at joint(s) 33, 34. 35, 36, 37, 38, 39, 40, 41. 42.32. 31
29, 24,27. 26, 25, 24. 23, 2,22
RENEWS:12t31t20
October 17,2019
SPAC|NG- 2-O-O
Plate Grip DOL 1.15
Lumber DOL '1.15
Rep Stress lncr YES
Code lRC2015/TP12014
csr.
TC
WB
Matrix-SH
o.26
0.14
0.08
DEFL.
Vert(LL)
Vert(CI)
Hoz(CT)
in
001
000
0.01
(loc) Udefl Ud
1 nlt 12O
1nh90
22 nla nla
lt't6t82
$ Wa?Uttte - V*W tl#.bt paryr8*,g &|,t r€4O #OrgS OtJ ??lr$ ANA INC\UA&t ,nffE/. rlrFrRF,lfi:S FAer #l/- 74n &€Ft;*E USE.
Design valid for use only with lVaTek connectors. This design is based only upon parameters shown, and is for an individual buildang component.
Applicabi!ity of design paramenters and proper incorporation of componenl is responsibility ol building designer - not truss designer. Bracing shown
is for lateral suppon of individual web members only. Additional temporary bracing to insure stabilily during construction is the responsibillity of the
ereclor Addflronal permanenl bracrng of lhe overall struclure is lhe responsibrlrly ol lhe burldrng desrgner For genelal gurdancejqS-qldinS_ -.
tabricatron. quatrry aontot. storage. d6livery eredon and bracrng consull ANSUTPI1 Oully Cribtb, DSB40 4d BCSII Bddhg CompoHt
Sshylnbmsdon availablekbmTrussPlatelnsttule,5S3D'OnokioDflve,Madison.Wl 53719
A
theTRUSSco.tNc.
8
3
Jrruss
IV5GE
lTruss Type
lcaaLr
lo', lt', lBruce Wiechert Custom HomesIr I 11 11s017078
I I lJob Referen@ (oohonar)
J1047743
Job
The Truss Company Eugene, OR - 97402 lvliTek lnc.Oct 16
-2-0{
24-0
S€le='l:13.1
3x4 --
too lz
7
2
g
q
4x1O =63x4
gxa ll 5
4€-0
43
3x4
LOADING (psf)
TCLL 25.O
(Roof Snow=25 0)
TCDL
PLATES
MT2O
GRIP
220t195
8.0
0.0 'BCLr
LUMBER.
TOP CHORD 2x4 DF No.2
BpT CHORD 2x4 DF No.2
WEBS 2x4 DF Stud
Weight: 23 lb FT = 2oo/o
Structural wood sheathing directly applied or 4-'10-0 oc purlins, except end ve(icals
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 6=159/Mechanical, 2=352/0-5-8
Max Horz 2=69(LC 7)
Max Uplift 6=-30(LC 10),2=-124(LC 6)
Max Grav 6=184(LC 17J,2=359(LC 17)
FORCES. 0b) - Max. Comp./Max. Ten - All forces 250 (lb) or less ex@pt when shown.
NOTES-
vertiGl left and right exposed; Lumber DOL=1.60 plate gnp DOL=1.60
2)Trussdesignedforwindloadsintheplaneofthetrussonly. Forstudsexposedtowind(nomaltotheface),seeStandardlndustryGableEndDetailsas
applicable, or consult qualified building designer as per ANSI/TPl I
3)TCLL:ASCE7-10;Pf=25.0psf(flatroofsnow) CategorylliExpB,PartiallyExp;Ct=110
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.OO times flat roof load of 25.0 psf on overhangs non-concurent with other live
loads
6) Gable studs spaced at 1-4-0 oc
7) This truss has been desiqned for a 10.0 psf bottom chord live load nonmncurent with any other live loads.
8) * This truss has been designed for a live load of 2o.Opsf on the bottom chord in all areas where a rectangle 36-0 tall by 2-0-0 wide will fit between the bottom
chord and any other members
9) Refer to qirde(s) lor truss to truss mnnections
1O) Provide mechani€l connection (by others) of truss to bearing plate capable o, withstanding '100 lb uplift at ioint(s) 6 exept (jt=lb) 2=124
RENEWS: 'tzt3'tt2o
October 17,2019
SPACTNG- 2-O-O
Plate Grip DOL 1.15
LumberDOL 1 15
Rep Stress lncr YES
Code lRC20'15/TP12014
cst.
TC
BC
WE]
Matrix-P
0 31
0.14
0.00
DEFL.
Vert(LL)
vert(cT)
Hoz(CT)
in
-o 02
-0.03
-0.00
(loc)
26
2-6
6
l/deff
>999
>999
nla
Ud
360
240
nla
OREGON
7'1 6'82
I waa,/lre-rr*xy{ri*&4rtr8{rese}dnEAoirorfsoivl}rr$r/Yr/r#r-{rpi:"oirr}5#fiFF€'r?FrvcFpA6e&*r-7dl3sE'F"oar"}s€
Design valid for use only with Mi1ek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
isforlateraisupportofindividualwebmembersonty. Additionaltemporarybracingtoinsurestabilityduringconstructionistheresponsibillityotthe
ereclor Additronal permanenl bracing ol the overalt struclure rs the responsibilrty ol the building desrgner For general gurdance_rgqqr.dIS_ ..
labncalron. ouatitv conlrot. storaae. ddlivery, erectron and bracino, consult ANSnPll OufU ClIsil., DSB{S md BCSII Bdding GompoMt
Slbly lnfunbto;r available fr;m Truss Plale lnst'tule. 583 D'onofrio Dnve. Madison wl 53719
A
theTRUSSco.tNc.
4S-0
4€-0
BRACING-
TOP CHORD
BOT CHORD
ruce Wiechert Custom Homes
r130170801047743NOPITCH
Type
1
Reference
The Truss Company lnc Wed Oct 16 17:49:282019
I D:2avwni0h0H gHxKDSKKV)/UgySncg E.lPqTeHo
2-8-O
2-8-0
3
3x4 ll
Scale = 1:9.8
4
aoo fi-10
o
N
2
J
Ji
6
3x4 5
3x4 ll
LOADING (psf)
TCLL 25.O
(Roof Snow=25 0)TQDL 8.0
BULL O,O
PLATES
[/]T20
GRIP
2201195
7.O Weight: 11 lb FT = 20o/o
Structural wood shealhing directly applied or 2-10-0 oc purlins, except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing
OfiEGON
7t16'82
LUMBER-
IgP CHORD 2x4 DF No.2
BoT CHORD 2x4 DF No.2WEBS 2x4 DF Stud
BRACING-
IOP CHORD
BOT CHORD
REACTIONS. (lb/size) 6=73/tvlechanical,2=28110-5-8
Max fiorz 2=45(LC 7)
lilax uprift 6=-12(Lc 7), 2=-1 1s(LC 6)
lrax Grav 6=83(LC 17),2=283(LC 17)
FORCES. (lb) - Max. Comp./Ma. Ten. - All forces 250 (lb) or less except when shown.
NOTES.
1)Wnd:ASCE7-'10;Vult=120mph(3-secondgust)Vasd=95mph,TCDL=4.8psf;BCDL=4.2psf,h=25ft,Cat ll,ExpB,Enclosed;IVWFRS(envelope)gableend
zone; cantilever left and right exposed , end verti€l leit and right exposed; Lumber DOL=1.60 plate grip DOL=1 .60
2) TCLL: ASCE 710; Pf=25 0 psf (flat roof snow); Category Il; Exp B, Partially Exp., Ct=1.10
3) Unbalanced snow loads have been @nsidered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or '1.00 times flat roof load of 25.0 psf on overhangs non-concurent with other live
loads.
5) This truss has been designed for a '10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) " This truss has been designed for a Iive load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom
chord and any other members.
7) Refer to girder(s) for truss lo truss connections.
8) Provide mechanicl connection (by others) of truss to bearing plate capable of withstanding 1 00 lb uplift at joint(s) 6 except 0t=lb) 2= 1 1 5.
RENEWS:12t31t20
October 17,2019
SPACTNG- 2-O-O
Plate Grip DOL 1 15
Lumber DOL 1.15
Rep Stress lncr YES
Code lRC2015/TP12014
csr.
IC
WB
lvl atri x- [4 P
o.25
o.07
000
DEFL.
Vert(LL)
Vert(CI)
Hoz(CT)
in (loc)
0.00 9
0.00 9-0.00 2
l/defl
>999
>999
nla
L/d
240
nla
*fo WX;U{** - U*iy @4 i&reos$ss ,&i .q,{IAS JVl-:,mS #S ${JC ANt} lfl1Lrr*; l^ ! *d dt t}'j{d/v*a p**# *4*r;,r,11 SS:};)d# iJ$$
DesignvalidforuseonlywithMiTekconnectors Thisdesrgnisbasedonlyuponparametersshown,andisforanindividualbuildingcomponent
Applicability of design paramenters and proper incorporalion of component is responsibility ol building designer - not truss designer Bracing shown
is for lateral suppoil of individual web members only. Additional temporary bracing to insure stability during constuction is the responsibillity of the
erector. Additiona permanentbracingoftheoverallstructureistheresponsibilityofthebuildingdesigner.Forgeneralguidanceregarding
labncanon, quaiily conlrol, slorage, delivery, erection and bracing, consult ANSITP|I Qu8lity C]ibrla, DSB-89 8nd BCSII Building Component
Ssfety ln omstion avarlable lrom Truss Plate lnstrlute, 583 D'Onofrio Drive, Nradison, wl 5371 I
-,a
,ru
theTRUSSco".rxc.
lo', Tt" lBrrce wt4 I 1l
I I lJob R.r"r"n""
1047743 113017081NOPITCH
Type
(oplional)
echert Custom Homes
Truss Company (Eugene), Eugene,8 320 s Oct I 20 19 MiTek
lD:2avwni0h0HgHxKD5KKVyUgysnsg mdtSFlG!clnCZBn
1-'10-0-2-0-o
2 0-0 iro{ -
Scale = 1:15 5
43x4 ll
3
eoo l1t
N
2
{
6
3x4 sx+ ll
LOADING (psO
TCLL 25.0
(Roof Snow=25.0)ICDL 8,0
BOLL O,O
LUMBER-
TQPCHORD 2x4DFNo2
BOT CHORD 2x4 DF No.2
WEBS 2x4 DF Stud
PLATES
Mr20
GRIP
220t195
BRACING.
TOP CHORD
BOT CHORD
Weight: 10 lb FT = 2oo/a
Structuralwoodsheathingdirectlyappliedor2-0-0ocpurlins exceptendverticals
Rigid ceiling directly applied or 10-0-0 oc bracing
OftEGON
7'1 6t82
REACTIONS. (lblsize) 2--277 10-5-8, 5='1o/lrechanical
Max Notz 2=62ltc 12)
Max Uprift 2=-73(LC 8), 5=-24(LC 14)
MaxGrcv 2=277(LC 1 ), 5=33(LC 4)
FORCES. (lb) - Irax. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES.
'1) Wnd: ASCE 7-10, Vult='120mph (3-second gust) Vasd=gsmph, TCDL=4 Spsf; BCDL=4.2psf; h=25ft; Cat. ll, Exp B, Enclosed; MVVFRS (envelope) gable end
zone; cantilever left and right exposed , end vertical left and right exposed, Lumber DOL='1 .60 plate grip DOL=1.60
2) TCLL: ASCE 7-10, Pf=25.0 psf (flat roofsnow), Category ll, Exp B, Partially Exp., Ct=1 10
3) This truss has been designed for greater of min roof live load of 1 6 0 psf or 1.00 times flat .oof load of 25.0 psf on overhangs non-concurent with other live
loads.
4) This truss has been designed for a '1 0.0 psf bottom chord live load nonconcurrent with any other live loads
5) . This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 36-0 tall by 2-0-0 wide will fit between the bottom
chord and any other members
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding '1 00 lb uplift at joint(s) 2, 5.
RENEWS:12t31t20
October 17,2019
SPAC|NG- 2-O-0
Plate Grip DOL 1 15
Lumber DOL 1.15
Rep Stress lncr YES
Code lRC2015/TPl20'14
csr.
TC
BC
WB
tu4 atrix- l\,1 P
o.26
0.09
0.00
OEFL.
Vert(LL)
Vert(CI)
Hoz(CT)
in
0.00
0.00
,0.00
(loc)
I
9
2
l/defl
>999
>999
nla
L/d
360
240
nla
Jfu fmrfil,i:.r;ai1-ds$*sS6s,w:wsddf$dilfd#I*:5*,q$t$11##&rtJ*;:#r.dllri(nliFisltliif*;F/1##l"d.i-;ctrs(F*a€tisf.
Design valid for use only with MiTek connectors. This deslgn is based only upon parameters shown, and is for an individual building component
Applicability of design paramenters and proper incorporation of component is responsibility of buildlng designer - not truss designer Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stabil[y during construction is the responsibillity of the
erector.Additionalpermanentbracingoftheoverallstructureistheresponsibilityofthebul]drlgqesigrlgrForgenqal_gurdancejgS-er,d]]lS... _
fabrication,quatitycontrot,storage,d;livery erectionandbracrng,consult ANSl/fPllQu8lilyCrib]h,DSBSgsndBCSllBuildingComponent
Ssrety lntomslbn available from Truss Plate lnstilule, 583 D Onofflo Drrve, l\,4adison, Wl 53719
el/llvt,74re
theTRUS$co"wc.
il;'
Job
5
FL=
I r russ rype
lcnaLr
I
lo"
l1
Jl047743
Job
fl::::
echert Custom Homes
113017082
Plv
1
(optional)
The Truss Company
-2-O4 6-0-0 120-0 14-O-O
3x4
4xB
S€le = 1:33 7
6
eoo Fz
3x4 //
3xa ll
4x8 /z
7
3
3x4 :\
3xa ll
B
3 t:
14 13 12 '11 '10 I4x8 :\
12-O-0
LOADING (psf)
TCLL 25O
(Roof Snow=25 0)
TCDL 8 O
BCLL O O
LUMBER.
TQP CHORD 2x4 DF No.2
BOI CHORD 2x4 DF No2
WEBS 2x4 DF Stud
OTHERS 2x4 DF Stud
PLATES
MT2O
GRIP
220t195
BRACING-
TOP CHORD
BOT CHORD
Weight: 77 lb FI = 20%
Structural wood sheathing directly applied or 6-0-0 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (tb/size) 2=610/0-3-8,8=610/0-3-8
lrax Horz 2=-104(LC 6)
Max Uplift 2=-102(LC 8), 8=-102(LC 9)
FORCES. (lb) - Max. Comp./Max Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-543151.3-4=469/73, 4-5=-489/98, 56=-495/96. 6-7=-473172,7-a=-548t51
BOT CHORD 2-14=01397.13-14=0/394, 12-13=0/390, 1'1-12=0/395, '10-11=0/399, a-10=ol4o2
WEBS 5-12=-75t421
NOTES.
'l) Wind: ASCE 7-lO; Vult=12omph (3-second gust) Vasd=gsmph, TCDL=4.8psf, BCDL=4 2psf, h=25ft, Cat. ll, Exp B, Enclosed, MWFRS (envelope) gable end
zone; €ntilever left and right exposed , end vertical left and right exposed, Lumber DOL=1.60 plate grip DOL=1 60
2)Trussdesignedforwindtoadsintheplaneofthetrussonly Forstudsexposedtowind(nomaltotheface),seeStandardlndustryGableEndDetailsas
appli€ble, or consult qualilied building designer as per ANSI/TPI 1
3) TCLLI ASCE 7-10, Pf=25.0 psf (flat roofsnow), Category ll; Exp B, Partially Exp., Ct=1.10
4) This truss has been designed lor greater of min roof live load of 16.0 psf or 1.OO times flat roof load of 25.0 psf on overhangs non-concurrent with other live
loads.
5) All plates are 1.5x4 MT20 unless otheMise indicated.
6) Gable studs spaed at 1-4-0 oc.
7) This truss has been designed lor a 1O.O psf bottom chord live load nonconcurent with any other live loads
8) * This truss has been designed for a live load of 2o.Opsf on the bottom chord an all areas where a rectangle 3$4 tall by 2-0-0 wide will fit between the bottom
chord and any other members.
9) Provide mechanicl connection (by others) oftruss to bearang plate €pable ofwithstanding '100 lb uplift atloinl(s) except (Jt=lb) 2=102. 8=102.
1O)Nonotchesallowedinoverhangand2OO0Ofromleftendand2OOOOfromnghtendor12"alongrakefroms€rf,whicheverislarger. Minimuml5x4tieplates
requiredat2-O-0o.c.maximumbetweenthestackingchords. Foredge-wisenotching,provideatleastonetieplatebetweeneachnotch.
RENEWS: 12t31t20
October 17,2019
DEFL.
vert(LL)
Vert(CT)
Hoz(CT)
in
-0 04
-0.06
0.01
(loc)
14
14
8
Udefl
>999
nla
Ud
360
240
nla
SPAC|NG- 2-O-O
Plate Grip DOL 1 15
LumberDOL 1 15
Rep Stress lncr YES
Code lRC2015/TP12014
csr.
TC
WB
Matnx-RH
0.30
0.46
0.14
1t16'82
OBEGON
A
theTRUSSco. txc.
4
2
W Rut.rc - VqW *lgt ,aanto/tr,,r dr.! AEAD ilOrES Ot T,llS Al@ NCLUO€O lllTEX REFERSiv6€ PA6 |LTTA BEF|RE tlsE'
S
ereclor
fabrcation qua ly
S8flty lntomslion
and
valid lor
1047743 D2
I rus9 I ype
lcorron lo', lt', lgruce wiecrtert custom HomesW I tl t13017083
I lroo *"r"rence (opronar)
lnc. Wed Oct 16 17:49:252019Company (Eugene)Eugene,
-2-04 12 0-O
6
'1.5x4 ll
6-0-0
12-O-0
3x4 \\
Scale = 1:30.2
4x4
aoo li,
4
J
2
I:
5
3x4 //
6-0-0
4:O-1-1
LOADING (psf)
rcLL 25.0
(Roof Snow=25.0)TCDL B,O
BCLL O.O
LUMBER-
TQP CHORD 2x4 DF No.2
BOT CHORD 2x4 DF No.2WEBS 2x4 DF Stud
PLATES
MT2O
GRIP
220t195
BRACING-
IOP CHORD
BOT CHORD
Weight: 48 lb FI = 20%
Structural wood sheathing directly appiied or 6-0-0 oc purlins
Rigid ceiling directly applied or 1 0-0-0 oc bracing.
REACTIONS. (lb/size) 2=61210-3-8,4=612/0-3-8
Max Hop 2=112(LC 7)
lvlax uprift 2=-99(Lc 8), a=,99(LC 9)
FORCES. (lb) - tulax Comp /lVax. Ten. - All forces 250 (lb) or less except when shown
TOPCHORD 2-3=-552t77,3-4=-552t76
BOTCHORD 2$=01372, 4-6=Ot372
NOTES.
'1) Wnd: ASCE 7-10, Vult=120mph (3-second gust) Vasd=gsmph; TCDL=4.8psf; BCDL=4.2psf, h=2sft; Cat. ll, Exp B; Enclosed, MWFRS (envelope) gable end
zone, €ntilever left and right exposed I end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL='1 60
2) TCLL: ASCE 7-10, Pf=25.0 psf(flat roofsnow); Category ll, Exp B, Partially Exp., Ct=1.10
3) This truss has been designed for greater of min roof live load of 1 6 0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live
loads
4) This truss has been designed for a 10.0 psf bottom chord live load nonmncurrent with any other live loads.
5) . This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom
chord and any other members.
6) Provide mechanical connection (by others) oftruss to bearing plate capable ofwithstanding 100 lb uplift atjoint(s) 2, 4.
RENEWS: 12t31t20
October 17,2019
SPAC|NG- 2-0.0
Plate Grip DOL 1.15
Lumber DOL 1.15
Rep Stress lncr YES
Code lRC2015/TPl20'14
cst.
IU
BC
WB
iMatrix-[4SH
032
0.25
007
DEFL.
vert(LL)
Vert(CT)
Hoz(CT)
in
0.03
-0 04
0.00
(loc)
6-9
6-12
4
l/defl
>999
>999
nla
L/d
360
240
nla
7t1 6182
lk *l.reltllr*'f*4C#i*4fiaw$w*eer*i?siq$Ssr?:S$l{;}rislllrlrr{:t#Sf$i-tl;-g{,i?Sl1{'lllil{s$f"{$6td&idf3$Si*6'flr$f
Design valid for use only with l\.4iTek connectors. This design is based only upon parameters shown. and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibilily of building designer - not truss designer. Eracrng shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
ereclor. Additional permanent bracing of the overall sruclure is the responsibility of the building designer. For general guidance regarding
fabrication, qualily control, storage, dalivery, erection and bracing, consull ANSYTPII OuElity CriEda, DSB89 8nd BCSI I Building Component
SEfuty lnfomslion available from Ttuss Plate lnstitute, 583 D'Onofrio Drive. l/adison, Wl 53719.
AlYl,E
theTRU$$cc. u'.tc.
3
1047743
-2-O-O 1 1 -0-0
Fffi:. Supported Gabre
lo', lt', lBruce Wiechert Custom Homesft | 11 113017084
i I lJob Rererence (optronat)
Truss
B,IGE
224-O 244-O
11{-0 ,nn-
S€le = 1 41.7
4x4
J
t.t-ldt
aoo fiT
I
'10
6
5 11
29 rz4
3 13
14
15 I;o
3x43x427262524232019 18
3x6 =
17 '16
22-O-O
LOADING (psf)
TCLL 25.O
(Roof Snow=25 0)
TCDL
BCLL
PLATES
lilT20
GRIP
220t195
8.0
0.0 '
LUMBER-
TOP CHORD 2x4 DF No.2
BOTCHORD 2x4DFNo.2
BRACING-
TOP CHORD
BOT CHORD
Weight: 100|b Ff = 20%
Structural wood sheathing directly applied or 6-0-0 oc purlins
Rigid ceiling directly applied or 1 0-0-0 oc bracing
OlHERS
REACTIONS.
0b)
2x4 DF Stud
All beanngs 22-0-0.
Max Hoz 2=62(LC 14)
MaxUplift All uplift'l00lborlessatjoint(s)23.24,25,26,27.21,20,18, 17, 16except2=-108(LC6),14.-117(LC7\
MaxGrav Allreactions25Olborlessatjoin(s)22,23.24,25.26,21,20,18,17except2=315(LC171,27'-25(lC1),16=296(LC1),
14=315(LC 18)
FORCES. (lb) - Max Comp /Max Ten. - All forces 250 (lb) or less except when shown
NOTES-
'1) Vvind: ASCE 7-10; Vult=120mph (3-second gust) Vasd=gsmph; TCDL=4.8psf; BCDL=4.2psf; h=25ft, Cat. ll, Exp B; Enclosed, MWFRS (envelope) gable end
zone; cantilever left and right exposed , end vertical lett and right exposed; Lumber DOL='1.60 plate grip DOL=1.60
2)Trussdesignedforwindloadsintheplaneofthetrussonly. Forstudsexposedtowind(nomaltotheface),seeStandardlndustryGableEndDetailsas
appli€ble, or @nsult qualified building designer as per ANSI/TPl 1.
3) TCLL ASCET-10; Pf=25.0psf (flatroof snw),Categoryll,ExpB,ParliallyExp;Q1=1 19
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 1 6.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live
loads.
6) All plates are 1.5x4 MT20 unless otheMise indi€ted.
7) Gable requires continuous bottom chord bearing.
8) Gable studs spaced at 1 -4-0 oc.
9) This truss has been designed for a '10.0 psf bottom chord live load nonconcurrent with any other live loads
10) * This truss has been designed for a live load of 2o.Opsf on the bottom chord in all areas where a r&tangle 36-0 tall by 2-0-0 wide will fit between the bottom
chord and any other members
11) Provide mechanical connection (by others) oftruss to bearing plate capable ofwithstanding 100 lb uplift atjoint(s)23,24,25,26,27,21,20, 18, 17, 16 except
tt=tb),2=1oe, fi=117
RENEWS: 't2t31t20
October 17,2019
SPAC|NG- 2-0-0
Plate Grip DOL 'l 15
Lumber DOL 1.15
Rep Stress lncr YES
Code lRC2015/TP12014
cst.
TC
BC
WB
Matnx-SH
o.25
o.12
0.05
OEFL.
vert(LL)
Vert(CI)
Hou(CT)
in
0.01
0.01
0.00
(loc)
15
15
14
l/defl Udnt 12onh 90
nla nla
7'1 6'82
il WenSSWe - Vnig tuign pana**a and P&4D,VOIES Of IrrS AND ll.tCLUD€D MtfEK REF€RENCE PACE Mll-7473 SEFOqE LiSE.
Design valid for use onty with MiTek connectors. This design as based only upon parameters shown, and is for an individual bualding component.
Appticabitiry of desiqn piramenters and proper incorporation of component as responsibiliiy of buildang designer - not truss designer. Bracing shown
isfortateraisupporiofindividualwebmimbersonly. Additionaltemporarybracingtoansurestabilityduringconstructionistheresponsibillityofthe
erector Addrtronat permanent bracing ol the ove,all structure rs the responsibility of the building desrgner For general gurdance reqar.djl1g_ .. _
tabncaron. ouatrv contot. sroraqe. ditrvery erection and bracrnq, consun ANS|IIPII Oulry Cdbt|a, DSB49 and BCSI1 Bladh[ Compoffil
Slhfy lnfumrioi available lrbm Truss plale Insllule. 583 D 0nokro Drive. t!'ladrson wl 53/19
A
theTRUSSco.tNc.
lob
8
7
2
Job
lrruss
t,,
lrruss lype
lcorron
I
lo', l"', lBruce Wiechert Custom Homes[r I rl 11301708s
I I lJob Referene rootronar)
J1047743
The 8.320 s Ocl 9 2019 l/iTek lnduslries, lnc Wed Oct 16 17:49:'13 2019 Page 1
lD:2avwni0h0HgHxKD5KKVyUgySnsg.A-x'l AJW5hvS0Cu2iAwNI KblikKyMz?flh4ioSal yySmMK
-2-04 5-1 0-1 4 1 1 -0-0
4x5
4
Scale = '1 :41.7
7
noo fiT
1.5x4 \\1.5x4 2
5
6
3
I;o
10 98
JXO -
3x4 =
3x4 JXC -3x5
144-12
7-74
LOADING (psf)
TCtL 250
(Roof Snow=25.0)
PLATES
l\ilT20
GRIP
220t195
TCDL
BCLL
80
0.0 '
LUMBER.
ToP CHORD 2x4 DF No.2
BOr CHORD 2x4 DF No.2
WEBS 2x4 DF Stud
BRACING-
TOP CHORD
BOT CHORD
Weight: 87 lb FT = 2O'/o
Structural wood sheathing directly applied or 4-1-2 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing
REACTIONS. (lblsize) 2=1O12lO-5-8, 6=1 01 2/0-5-8
iilax Hoz 2=62(LC 14)
Max Uprifl 2=-203(LC 6), 6=-203(LC 7)
FORCES. (lb) - Max. Comp /Max. Ten. - All forces 250 (lb) or less except when shown
TOP CHORD 2-3=-2063t291. 3-4= -17 981246. 4-5='17981246, 5$= -20631291
BOI CHORD 2-1 0=-25911 91 5, 8-1 0=-'1 1 3/1 288, 6-8=-203/1 9'1 5
WEBS 4-A=-771610.5-8=472h55.4'10=-771610,3-10=4721155
NOTES-
1)Wnd:ASCE7-10;Vult=12Omph(3-secondgust)Vasd=gsmph;TCDL=4.8psf;BCDL=42psf;h=25ft;Cat ll;ExpB;Enclosed,iilVVFRS(envelope)gableend
zone; mntilever left and right exposed , end vertical lelt and right exposed, Lumber DoL=1.60 plate grip DOL=1 60
2) TCLL: ASCE 7-1O, Pf=25 0 psf (flat roof snow), Category ll; Exp B, Partially Exp. Ct=1 10
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1 OO times flat roof load of 25.0 psf on overhangs non-concurent with other live
loads.
5) This truss has been designed for a 1O.O psf bottom chord live load nonconcurent with any other live loads.
6) 'This truss has been designed for a live Ioad of 2o.Opsf on the bottom chord in all areas where a retangle 3$-0 tall by 2-0-0 wide will fit between the bottom
chord and any other members
7) provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplitt at joint(s) except (Jt=lb) 2=203, 6=203
RENEWS: 12t3'1t20
October 17,2019
Matrix-l\rsH
csr.
TC
BC
WB
0.40
0.49
020
DEFL.
Vert(LL)
Vert(CT)
Hoz(CT)
in
-0.1 1
-0.18
005
(loc)
8-'10
8-'10
6
l/defl
>999
ola
Ud
360
240
nla
SPAC|NG- 2-0-O
Plate Grip DOL 1 15
Lumber DOL I 15
Rep Stress lncr YES
Code lRC2015/TP12014
7tl6'82
A
theTRUSSco.tNc.
3
2
shown
of the
Component
theTRUS$co. INc.
I
PI.ATE LOCATION AND ORIENTATION
' Plac location details available in MlTek Z)t120
softrrvam or upon l€gu€st
ISTERAL BRACI NG LOCATION
lndicated by symbol shown and/or
by text in the bracing section of the
output. Use T, I or Eliminator bracing
if indicated.
lndusry SEndards:
ANSI/TPl1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI 1: Building Component Safety lnformation,
Guide to Good Practice for Handling,
Symbols
PISTE SIZE
4x4
BEARING
g-1 d'
1
For 4 x2 orientation, locate
plates 0- lrrs" from outside
edge of truss.
lndicates location where bearings
(supports) occur. lcons vary but
reaction section indicates joint
number where bearings occur.
This symbol indicates the
required direction of slots in
connector plates.
The first dimension is the plate
width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
lnstalling & Bracing of Metal Plate
Connected Wood Trusses.
C]
WEBS
=B
Numbering System ,A ,Ggneral $afety Notes
| 6-a-8 t dlmenslons shown ln ft.ln.slxt€enths
;ailure to Fo,low Could Cause Property
Damage or Personal lnjury
(Drawings not to scale)
1, nldil,onal stabiltty braqirig,for truss system, e.g.
d,Jgc.rJl orX-braring,';alvays required. See BCS|1.
2 T-uss I racing nlj:tbe lesrgned by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative T, l, or Eliminator
bracing should be considered.
3. Nevcr exc?ec ttre de.ign loading shown and never
stack l,ratLnJls or. i radequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members lo bear tightly against each other.
2
TOP CHORDS
B
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWSE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-131 1, ESR-13s2, ER-5243, 96048,
9730, 95-43, 96-31, 9667A
NER-487, NER-561
951 10. 84-32, 96-67, ER-3901,94324
O 2006 MiTek@ All Rights Reserved
6. Place plates on each face of truss al each
joint and embed fully. Knots and wane at ioint
locations are regulated by ANSUTPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPl 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed .l9o/o at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber
1 0. Camber is a non-structural consideration and is lhe
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
1 1. Plate lype, size, orienlation and location dimensions
indicated are minimum plating requirements.
1 2. Lumber used shall be of the species and size, and
in all respects, equal to or better than thal
specified.
13. Top chords musl be sheathed or purlins provided at
spacing indicated on design.
14. Boltom chords require lateral bracing at l0 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
1 5. Connections not shown are the responsibility of olhers.
16. Do not cut or aller truss member or plate without prior
approval of an engineer.
17. lnstall and load vertically unless indicated otherwise.
1 8. Use of green or treated lumber may pose unacceptable
environmenlal, health or performance risks. Consull with
projecl engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufflcient.
20. Design assumes manufaclure in accordance with
ANSI/TPI 1 Qualily Criteria.
4
otro
=O
o_oF
ltr
-
IoF
DS
q67
l-l-T
L
1