HomeMy WebLinkAboutPermit Building 2003-11-04\
Building/Combination Permit
.,1 Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Ftx
541-7 26-37 69 Inspection Line
PERMIT NO: COM2003-00920ISSUED: 1110412003APPLIEDz 0911712003EXPIRES: 06/0812004VALUE: $ 120,000.00
SITE ADDRESS: 1661 Mohawk Blvd
ASSESSORTS PARCEL NO.: 1703253105800
PROJECT DESCRIPTION: Starbucks Coffee Company
Springfield TYPE OF WORK: Restaurant
TYPE OF USE: New Commercial
Owner: HAMMERBROTHERSLLC
Address: PO BOX 2266 EUGENE OR 97402
Contractor Type
Architect
General
Electrical
Mechanical
Plumbing
Contractor
FREIHEIT & HO ARCHITECTS INC
WESTERN CONSTRUCTION SERVICES
JB ELECTRIC
BEWLEY MECHANICAL SYSTEMS INC
D&DACQUISITIONSINC
License Expiration Date
63717
104929
63s82
87906
0u22t2004
03n4t2004
0u16t2005
12n9t2003
Phone
425-827-2100
360-699-s317
541-687-s770
503-626-8986
503-691-6166
# of Units:
Primary Occupancy Group:
Secondary Occupancy Group:
Primary Construction Type
Secondary Construction Type:
# of Bedrooms:
SETBACKS
Frontyard Setback:
Side I Setback:
Side 2 Setback:
Rearyard Setback:
Solar Setbacks:
Street Improvements:
Storm Sewer Available:
Special Instruction:
# of Stories:
Height of Structure
Type of Heat:
Water Type:
Range Type:
Lot Size:
Sq Ft lst Floor:
Sq Ft 2nd Floor:
Sq Ft Basement:
Sq Ft Garage/Carport
Sq Ft Other:
Impervious Surface Area:
t'rUtrce:
B
ANY 1
IHIS PIRM
AUIHONIZE E ,F THE WORK
II
D
Overlay Dist:
# Street Trees Rqd:
Paved Drive Rqd:
%o ofLot Coverage:
REQUIRED PARJflNG
Total:
Handicapped:
Compact:
Sidewalk Type:
DownspoutslDrains:
Notes:
Page I of4
NLJTI
G
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541-7 26-37 69 Inspection Line
PERMIT NO: COM2003-00920ISSUED: 1110412003APPLIEDT 0911712003EXPIRES: 06/0812004VALUE: $ 120,000.00
Description
Bid Amount
Tyne of Construction
Use Bid Amount
$ Per Sq Ft Square Footage
or multiplier or Bid Amount
$1.00 120,000.00
Total Value of Project
Amount Paid Date Paid
Value
$120,000.00
$120,000.00
Date Calculated
09n7t2003
Fee Description
Plan Review Comm/Ind/Public
PIan Review Fire & Life Safety
SDC MWMC Administration
SDC MWMC Improvement
SDC MWMC Reimbursement
SDC Sanitary/Storm Admin
SDC Transpo Admin
SDC Transpo Improvement
SDC Transpo Reimbursement
-Mechanical Issuance Fee-
+ l0o/o Administrative Fee
+ l0/o Administrative Fee
+ 1oh State Surcharge
+ 77o State Surcharge
Add, Alter, Extend Circ
Add, Alter, Extend Circ Ea Add
Addressing Assignment
Backflow Device
Building Permit
Fixture
Furnace - up to 100,000 btu
Gas Outlets 14
Minimun/Adjustment Mechanical
Sanitary Sewer - Improvement
Sanitary Sewer - Reimbursement
Temporary Occupancy
$409.92
$252.26
$r0.00
$1,211.13
$3,176.46
$83.72
$838.68
$10,414.39
$2,360.74
$10.00
$17.s0
$84.37
$12.25
$s9.06
$43.00
$132.00
$8.00
$14.00
$630.6s
$154.00
$24.00
$4.00
$17.00
$550.72
$724.48
$100.00
9n7t03
9n7t03
10/31/03
10/31/03
10/31/03
t0t3U03
10/31/03
10/31/03
10/31/03
tu4t03
tu4t03
tu4t03
tu4t03
tu4t03
tU4t03
tU4t03
tu4t03
tu4t03
tu4t03
tu4t03
tu4t03
tu4t03
tu4t03
ru4t03
tu4t03
t2lt7l03
Receipt Number
2200200000000001s42
2200200000000001542
2200200000000001708
2200200000000001708
2200200000000001708
2200200000000001708
2200200000000001708
2200200000000001708
2200200000000001708
1200200000000002416
1200200000000002421
1200200000000002416
120020000000000242r
1200200000000002416
1200200000000002421
1200200000000002421
1200200000000002416
1200200000000002416
1200200000000002416
1200200000000002416
1200200000000002416
1200200000000002416
1200200000000002416
1200200000000002416
1200200000000002416
2200200000000001891
Fees Pe
Total Amount Paid $21,342.33
Paee 2 of4
Plan Reviews
Valuation Description I
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541 -7 26-37 69 Inspection Line
PERMIT NO: COM2003-00920ISSUED: 1110412003APPLIEDz 0911712003EXPIRES: 06/0812004VALUB: $ 120,000.00
Fire Department Review 0912312003 10t22t2003 0K GRG
09fi7t2003 09123t2003 wE JMP
Plan Review: Starbucks coffee housc
(infill in two occupancy building
next to Subway). Job
#COM2003-00920. Occupancy
Classification : B. Construction
Type: V-N.3000 sq. ft.
Provide address numbers in
contrasting color from the
background positioned plainly
visible and legible from the street or
road fronting the property (1998
Oregon Structural Specialty Code
502 and 1997 Springfield Uniform
Fire Code 901.4.4\.
Fire Extinguishers: Plan Sheet A4.0
shows lire extinguisher to be located
in the workroom. Composite plan
note #13 states, I'Contractor to place
fire extinguisher in workroom per
fire inspector.rr Fire extinguisher
shall be rated at least a minimum of
2-A:10-B:C. Will verify on
inspection.
f0/8/03 - Plans received and
assigned to Steve Barnes for review.
KJV
Received 912312003 from Dave
Puent. JMP left a voice mail
message for Amanda Oberg on
9 123 12003 requesting missing
information.
Amanda emailed the remainder of
the missing information today.
JMP called Amanda Oberg in the
architectrs office to request
corrected Form 3a plus Chapter 3
forms and worksheets.
Initial Review
Planning Review
Public Works Review
Structural Review
Structural Review
SUB Review
SUB Review
09n5t2003
09t23t2003
09t23t2003
t012u2003
09t23t2003
091r7t2003
r0/08i2003
10n4t2003
t0t2U2003
10t06t2003
LLH
EMM
SB
JMP
JF
APP
APP
APP
APP
WE
t0t23t2003 10t23t2003 APP JF
To Request an inspection call the 24 hour recording at 726-3769. All inspection requested before 7:00 a.m.
will be made the same working day, inspections requested after 7:00 a.m. will be made the following work
day.
Page 3 of4
F
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541-7 26-37 69 Inspection Line
PERMIT NO: COM2003-00920ISSUED: 1110412003APPLIEDz 0911712003EXPIRES: 06/0812004VALUE: $ 120,000.00
I
2
3
4
5
6
7
8
9
10
11
t2
13
t4
15
t6
17
18
Framing Inspection: Prior to cover and after all rough in inspections have been approved.
Drywall: Prior to taping.
Ceiling Grid: After drywall approval but prior to cover.
Ceiling Insulation: Prior to coyer.
Final Fire Department. After all requirements of the Fire Department have been met.
Final Building: After all required inspections have been requested and approved and the building is complete.
Rough Plumbing: Prior to cover and including required testing.
Final Plumbing: When all plumbing work is complete.
Rough Mechanical: Prior to Cover
Final Mechanical: When all mechanical work is complete.
Rough Electric: Prior to Cover
Final Electric: When all electrical work is complete.
SUB Insulation Vapor Barrier: To be called for at the same time as the SUB framing inspection.
SUB Final: After all required energy inspections have been requested and approved.
SUB Plumbing: Following City Rough Plumbing inspection approval and prior to cover.
SUB Mechanical: Following City Rough Mechanical inspection approval and prior to any cover.
SUB Ceiling Grid: Interior Lighting
SUB Exterior Lighting
By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all
information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with
the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and
that NO OCCUPAI\CY will be made of any structure without permission of the Community Services Division, Building Safety.
I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project.
I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the
the card is located at the front of the property, and the approved set of plans will remain on the site at all
tz7<
Signature Date
Page 4 of 4
225 Fifth Street
Springfield, Oregon 97 477
541-726-3759 Phone
City df Springfield Official Receipt
Development Services Department
Public Works Department
#ate:lzl2:
coM2003-00920 Temporary Occupancy
Item Total:
100.00
$100.00
TypeofPayment PaidBy
CreditCard DEAN KNUDTSON
Received Batch Number Authorization Number How Received
DJB 0002s I 0t7t3t In Person
Payment Total:
Amount Paid
$100.00
$100.00