Loading...
HomeMy WebLinkAboutBuilding Mechanical 1994-07-26COM M ERCIAL/ I N DUSTRIAL PERMIT APPLICATION 225 Fitlh Street, Springfield, Oregon 97477 SPRINGFlELO q//D:fJOB NUMBER INSPECTION LINE: 726-3769 OFFICE: 726-3759 LOCATION OF PROPOSED WORK:1565 Mohawk Blvd. (aAAQX{!Q'S) ASSESSORS MAP:rAX Lor: Odi!@' ADDRESS: 1782 N. Sth 72A-qR6RPHONE: Sprinqfield N.I.P.I. Corooration ztP: 97477STATE: oregonCITY: OWNER NEW - REMODEL ADDITION DEMOLISH OTHEFT VALUE: Replace 3 roof to p qas/electric uni-tsDESCRIPTION OF WORK ARCHITECT GENERAL: NAME ADDRESS PHONE ADDRESS EXPIRES PHONECONTRACTOR'S NAME PLUMBING: MECHANICAL: ELECTRICAL: CONST. CONTRACTOR # PLUMBING NO FEE CHARGE Single Fixture Relocated Bldg. (new fix. addtl) Water Service ft. Sanitary Sewer ft Storm Sewer t( Backf low Device TOTAL PERMIT MECHANICAL NN FFtr CHARGE Furnace/burner & vent < 100,000 BTUs Furnace/burner & vent > 100,000 BTUs Floor furnace and vent Suspended wall or f loor mounted unit heater Appliance Vent separate Stationary evap. cooler Vent Fan/Single duct Vent Sys from AC tem apart or htg. Mechanical exhaust hood and duct 3 replace 60,000 BTU I)/8uoo/ srsu ur rL PEElsuguu-- Permit lssuance Units $10.00 TOTAL PERMIT - OFFICE USE - ZONING HANDICAP ACCESS FLOOD PLAIN LIGHTING POWER BUDGET: LAND USE: OCCY GROUP: * OF STORIES: QUAD AREA: * OF BLDGS: CONSTR. TYPE: HEAT SOURCE: Y OF UNITS: WATER HEATER: SQ. FT.$/SQ. FT.VALUE TOTAL VALUE OF PROJ X X SQ. FTG MAIN SQ. FTG ACCESS SQ. FTG OTHER PLAN CHECK FEE RCPT#DATE BY ??,//. BUILDING PERMIT PLUMBING DEMOLITION 5% State Surcharge 5% State Surcharge MECHAN /trZ FENCEnnlue s s% Stat6- Surcharge )oN4 SIDEWALK FT. SUBTOTAL PERMITSPAVI N G CURBCUT FT. SYSTEMS DEVELOPMENT TOTAL PERMIT FEES EXCLUDING ELECTRICAL Cnmfor"t F] ow Heati ng 855 tnl- Fi rst , Frrgene , 0R 974O2 00460 6/27/95 342-8101 v. REQUtRED TNSPEcnoNS It is the responsibility of the permit holderto see that all inspections are made at the proper time. To request an inspection, call 726.3769 (recorder), state your City designated job number, job address, type of inspection requested and when you will be ready for inspection. Requests received before 7:00 a.m. will be made the same working day, requests made after 7:00 a.m. will be made the following work day. S|TE INSPECTION: To be ROUGH PLUMBING, PAVING: After gravel is in made after excavation, but ELECTRICAL & place but prior to placing prior to setup of forms. MECHANICAL: No work is to asphalt or concrete. be covered until these UNDERSLAB pLUMBING, inspections have been made SPECIAL INSPECTIONS: ln accordance ELECTRICAL & and approved. section 306 0f the state Specialty code MECHANICAL: To be made , a special inspector shall be employed before any work is covered. ATTIC DRAFT STOPS & by the Owner/ Contractor during CURTAIN WALLS construction of the following work. A FooTINGS & FoUNDATIoNS: E,bEn, A^E. r copy of the special testing reports shall To be made after trenches are FIREPLACE: Prior to plaqing be furnished to the Building Division. excavated and forms are facing materials and before erected, ail steel in place, but framing inspection' STRUCTURAL CONCRETE: ln prior to placing concrete. FRAMING: To be made after excess of 2500 P.S.l' (306 a'1) coNcRErE sLAB: ro be t["];:l ilJ'il'Jlfli,t]i ,^ srRUcruRAL wELDS: made after all inslab building place and all pipes, chimneys Performed on the lob. (2722f') service equipment, conduit, and vents are'complete andpiping, accessories and other the rough electrical, plumbing HIGH STRENGTH BOLTING: ancillary equipment items are and meLhanical are approved. During all bolt installation and in place but before any tightening operations. (306 concrete is placed. INSULATION & VApOR a.6) BARRIER: To be made after all UNDERGROUND: Plumbing, insulation and required vapor SPRAYED ON electrical, gas, sanitary sewer, barriers are in place but FIREPROOFING: U.BC. storm sewer, water and before any lath or gypsum Standards 43-8. drainage lines. To be made board interior wall covering is prior to covering or filling applied. SpECIAL GRAD;NG, ;::"j:,""R: p umb ns [;x1],f.'3*,Jfl]"g]* il;fut'iix-tli.:,5J:'j],"1 electrical, mechanical. To be according to plans. Chapter 29) made prior to installation of , ^?u Art^,A6 ^vDcrrir GLU.LAM BEAMS: lnspectionfloor insulation, decking or LATH AND'OR GYPSUM floor sheathing. BOARD: To be made after all Certificate by an approved lathing and gypsum board, agency' furnished to the City's posr & BEAM: To be made interiol and exierior, is in Building Division before prior to installation of floor fiace Uut before any beams are placed' (2501 U'B."' insulation, decking or f loor plastering is applied or before STDS' 25-10J1)' sheathing. Jvvr\rrrv gypsum board joints and fasteners are tiped and STRUCTURAL MASONRY: (306 FLooR TNSULATToN & finished' a'7\ VAPOR BARRIERS: To be made Prior to installation of decking or floor sheathing. MASONRY: Steel location, bond beams grouting or verticals in accordance with uBc 2415. SIDEWALK & DRIVEWAY: Required for all concrete paving within street right oi way, to be made after all excavating comPlete and form work and sub-base material in place. CURB AND APPROACH APRONS: After forms are erected but prior to placing concrete. *ln addition to the inspec- tions specified, the Building Official may make or require other inspections of any construction work to ensure compliance with the Building, City or Development Code. ROOF SHEATHlNG AND NAILING: Prior to installing any roof covering. By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information herein is true and correct,"and I further certify thit any and all work performed shall be done in accordance with the ordinances of the city of springfield, and the Laws of the state of oregon pertaining to the work described herein, and that No occuPANoY will be made of any structure without permission of the Building safety Division. I further certify that only contractors and employees who are in compliance with oRS 701.055 will be used on this project. requested at the proper time, that project address is readable f rom the property, and the approved set of plans will remain on the site at all Signature Date I further agree to ensure that all required inspections are street, that the permit card is located at t front of t times during constru ton ?e. yr/ VALIDATION ^?,AMOUNT RECEIVED: RECEIPT *:RECEIVED BY: DATE PAID: FINAL PLUMBING FINAL ELECTRICAL \FINAL MECHANICAL FINAL FIRE DEPARTMENT SITEPLANREVIEWBOARD:Mustberequested2daysinadvance of the date you wish inspection. All project conditions such as landscaping, parking lot stri ping, etc. must be completed before requesting this insPection. FINALBUILDlNG:Requestedafterthefinalplumbing,electrical, mechanical and Fire Department inspections are made and approved. No occupancy of the premises can be made until a iertificate of Occupancy has been issued by the Building Dlvision and Posted on the Premises. ADDITIONAL COMMENTS: PLANS REVIEWED BY DATE ?- 2 {-7L/ CITY OF SPR'A'GFIELD, OREGON rhe ro[owr ns. ffi, ffX,m*#f,"*225 FTII]H STREET zoning' and d< spRrNGprEID, OREGOII 97472roval' TNSPBCTIoNREOUESTz 726-3762*ng- CC , oPFrcE: 726-3759 r,,e-?iz3b,- 3. coupr,ETE EEE scEEDIILB BELoIT 1.LOCA,TION OF Nev Resident ial-Single orr55Multi-Famity per dvelling unit. Service Included:ftems Cost JOB DBSCRIPTTON 1000 sq.ft. or less Each additional 500 sq. ft or portion thereof Each Manuf'd Home or Modul-ar Dvelling Service or Feeder s 8s.00 Permits are non-transferable and expire if vork is not started within 180 days of issuance or if vork is suspended for 180 days. 2. CONTRACTOR INSTALI,ATION ONLY Electrical Contractor Address Ci Phone r1+l -AA3 b Superv i sor cense Num ber I lo9 ,\ Expiration Date lo-t-q5 Constr Contr. Number c I s4q Expiration Date q-t-q+ ure of SuPervising Electrician SPRllt GFIELD Services or Feeders Installation, Alterations or Relocation: Sum o B 200 amps or 1 201 amps to 4 401 amps to 6 601 amps to 1" ess 00 amps 000 amps_ s 1s.00 $ 40.00 100 130 300 40 $ 3s.00 $ 2.00 ) $ ) ) ) s 00 00 00 00 00 00 50 60 S Temporary Services or Feeders Installation, Alteration or Relocation 200 amps or less $ 40.00 over 4b1 to 600 amps - $ 80.00 Over 600 amps or 1000-toTTs see 'rB" above Branch Circuits Nev, Alteration or Extension Per Panel 35ao Ovners Name Address o Ci ty pnone rl kb'98bb OIJNER TION The installation is being made on property f ovn vhich is not intended for safe, ]ease or rent. Ovners Signature: DATE: Over 1000 amps/volts One Circuit I Each AdditionaL Circuit or vith Service or Feeder Permi t A SUBTOTAL OF ABOVE 52 State Surcharge 3Z Administrative Fee TOTAL C D0 -4rlo E. Miscellaneous (Service/feeder not included) -Each installation Pump or irrigation $ sign/outline Lighting- $ t imited Energy/Res - $ Limited Energy/Comm S 40.00 40.00 20.00 36.00 39'oo t^q5 t. t'l +A, t L.RECEIVED 5 mtrl,ucrntcAl, PERHTT APPLTCATToN city Job N*b", ?727-{ I,EGAL DESCRIPTION /"e7-2<^7// alFa-