HomeMy WebLinkAboutPermit Building 2003-09-18CITY OF SPRINGFTELD
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541-7 26-37 69 Inspection Line
PERMIT NO: COM2002-01391ISSUED: 0911812003APPLIEDz 1211912002EXPIRES: 06/0812004VALUE: $ 298,000.00
SITE ADDRESS: 1657 Mohawk Blvd
ASSESSORTS PARCEL NO.: U03253105800
PROJECT DESCRIPTION: Subway + additional restaurant
Springfield TYPE OF WORK: Restaurant
TYPE OF USE: New
Owner: HAMMERBROTHERSLLC
Address: POBOX2266 EUGENE OR 97402
03t2u2005
09t30t2004
04t30t2004
t2n8t200s
03t07t200s
Commercial
Phone
541-485-4963
541-501-s985
541-686-0905
541-686-4482
54t4614821
541-988-0868
541-451-5141
Contractor Type
Architect
General
Electrical
Landscape
Mechanical
Plumbing
Sewer
Contractor
ROBERT SHAW
MARK DORMAN CONSTRUCTION LLC
ROSE CORPORATION
DAKOTA LANDSCAPE AND IRRIGATION
COMMERCIAL AIR INC
EUGENE EXCAVATION & PLUMBING
MORSE BROS INC
License Expiration Date
147257
s443r
7430
I 10075
r38003
CONTRACTOR INFORMATION
BUILDIN(
# of Units:
Primary Occupancy Group:
Secondary Occupancy Group:
Primary Construction Type
Secondary Construction Type:
# of Bedrooms:
SETBACKS
Frontyard Setback:
Side I Setback:
Side 2 Setback:
Rearyard Setback:
Solar Setbacks:
# of Stories:
Height of Structure
Type of Heat:
Water Type:
Range Type:
Energy Path:
Overlay Dist:
# Street Trees Rqd:
Paved Drive Rqd:
Yo ofLot Coverage:
Lot Size:
Sq Ft lst Floor:
Sq Ft 2nd Floor:
Sq Ft Basement:
Sq Ft Garage/Carport
Sq Ft Other:
Impervious Surface Area:
A-3
B
VN
VN
3,000
Street Impro"t*Sll$E:-- ----r-- iliSFtnt'lttr
3[:liffi:ffiffi;2,7,
Notes: ANY 180 DAY
s H ALhfilfifi 6Jf"JtlE W0 RK
ui'iDERlild P'r-nMt ls NoT
tn rs ABANDoNED FoR
PERIOD.
Sidewalk Type:
Downspouts/Drains:
REQUIRED PARKING
Total:
Handicapped:
Compact:
DEVELOPMENT INFORMATION
PUBLIC IMPROVEMENTS
Pase I of8
To Storm Sewer
IlBtrS,O
trL
i L)i
oogl rpies of the rules t
te: the telePhone
UtilitY Notilication
$2-2344)-nurn:
Building/C ombination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541-7 26-37 69 Inspection Line
PERMIT NO: COM2002-01391ISSUED: 09/18/2003APPLIED: 1211912002EXPIRES: 06/0812004VALUE: $ 298,000.00
Description
Bid Amount
Paving
Tvpe of Construction
Use Bid Amount
Use Bid Amount
$ Per Sq Ft
or multiplier
$1.00
$1.00
Square Footage
or Bid Amount
240,000.00
58,000.00
Value
$240,000.00
$58,000.00
$298,000.00
Date Calculated
12n9t2002
04n8t2003
Amount Paid
Total Value of Project
Date Paid
Fee Description
Plan Review Comm/Ind/Public
-Mechanical Issuance Fee-
+ l0o/o Administrative Fee
+ l0Yo Administrative Fee
+ l0o/o Administrative Fee
+ 7oh State Surcharge
+ 77o State Surcharge
Addressing Assignment
Air Handling Unit Up to 10,000
Building Permit
Curbcut - Additional Driveway
Curbcut Permit
Encroachment Permit
Fixture
Furnace - up to 100,000 btu
Gas Outlets 1-4
Paving
Plan Review Comm/Ind/Public
Plan Review Fire & Life Safety
Sanitary Sewer - lst 50 Feet
Sanitary Sewer - Improvement
Sanitary Sewer - Reimbursement
Sanitary Sewer Each Addtl 100'
SDC MWMC Administration
SDC MWMC Improvement
SDC MWMC Reimbursement
SDC Sanitary/Storm Admin
SDC Transpo Admin
SDC Transpo Improvement
SDC Transpo Reimbursement
Sidewalk Repair Permit
Storm Drainage Impervious Area
Storm Sewer - lst 50 Feet
Storm Sewer Each Addtl 100'
Temp Power 200 amps or less
Receipt Number
1200200000000000434
1200200000000001068
1200200000000001068
1200200000000001068
r200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
r200200000000001068
1200200000000001068
r200200000000001068
r20020000000000r068
r200200000000001068
$663.42
$10.00
$s.00
$40.19
$160.57
$3.50
$84.27
$8.00
$24.00
$698.90
$30.00
$7s.00
$120.00
$210.00
$36.00
$4.00
$401.8s
$-86.61
$3s4.96
$45.00
$957.03
$1,259.13
$28.00
$10.00
$241.57
$4,062.34
$384.27
$9s3.46
$13,039.28
$2,955.24
$10.00
$4,230.00
$45.00
$42.00
$50.00
t2n9t02
4t2st03
4t2st03
4t25t03
4t25t03
4t25t03
4t25/03
4t25t03
4t25t03
4125103
4t25t03
4t2st03
4t25t03
4t25t03
4tzst03
4t25t03
4t25t03
4t2st03
4t25t03
4t25t03
4t25t03
4t25t03
4t2st03
4t2st03
4t2st03
4t2st03
4t25t03
4t25t03
4t25t03
4t2st03
4t25t03
4t2st03
4t25t03
4t25t03
4t25t03
Fpps Peid
Pase 2 of 8
\ffi-
ValuationDeseriBtioil
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541-7 26-37 69 Inspection Line
Building/C ombination Permit
PERMIT NO: COM2002-01391ISSUED: 0911812003APPLIEDz 1211912002EXPIRES: 06/0812004VALUE: $ 298,000.00
Vent Fan
Water Line - lst 50 Feet
Water Line - Each Addtl 100'
+ l0oh Administrative Fee
+ 7Vo State Surcharge
Add, Alter, Extend Circ Ea Add
Perm ServiFdr 201 to 400 amps
Refund - Admin Fee
+ l0oh Administrative Fee
+ 7%o State Surcharge
Add, Alter, Extend Circ
Add, Alter, Extend Circ Ea Add
+ l0oh Administrative Fee
+ 77o State Surcharge
Backllow Device
Minimum/Adjustment Plumbing
Total Amount Paid
$12.00
$45.00
$14.00
$16.50
$11.55
$90.00
$7s.00
$-40.19
$11.s0
$8.05
$43.00
$72.00
$4.s0
$3.1s
$28.00
$17.00
4t25103
4t25t03
4t25t03
5/8/03
5/8/03
5/8/03
s/8/03
5n2t03
9/18/03
9/18/03
9/18/03
9/18/03
t2t8t03
t2t8t03
t2t8t03
12l8t03
1200200000000001068
r200200000000001068
1200200000000001068
1200200000000001 148
1200200000000001 148
1200200000000001 148
r200200000000001 148
voucHER#61998
2200200000000001544
2200200000000001544
2200200000000001s44
2200200000000001544
1200200000000002571
1200200000000002571
1200200000000002s71
1200200000000002571
$31,566.43
Plan Reviews
Paee 3 of 8
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541-7 26-37 69 Inspection Line
PERMIT NO: COM2002-01391ISSUED: 0911812003APPLIEDz 1211912002EXPIRES: 06/0812004VALUE: $ 298,000.00
Fire Department Review 1212312002 0112712003 OK GRG
Initial Review 12t20t2002 12t23t2002 APP LLH
Plan Review of proposed Subway
restaurant. Additional restaurant
plans not included. A-3 occupancy;
V-N construction. 3,000 sq. ft.
Provide exit signs meeting the
requirements of 1998 Oregon
Structural Specialty Code 1003.2.8.
Provide means of egress lighting
meeting the requirements of OSSC
1003.2.9.
Egress lighting shall be maintained
at a minimum of 1 footcandle at
floor level per 1998 OSSC 1003.2.9.
On the main exit door, provide sign
stating "THIS DOOR MUST
REMAIN UNLOCKED DURING
BUSINESS HOURS." (OSSC
1003.3.1.8, exception 1)
Post address numbers visible from
the street (OSSC 502; Springfield
Uniform Fire Code 901.4.4)
Provide 2-A:10-B:C rated fire
extinguisher within 75 feet of travel
distance within the restaurant.
(suFC r002.1)
Needed to verify location and
address assignment with Jim
Donovan.
Planner is Jim Donovan, DRC
2002-070226. Site Plan Review is
not complete yet as of l2l3ll02,
Site Plan Not Complete
Site Plan Not Comptete
THE ASSOCIATED PUBLIC
IMPROVEMENT PROJECT
MUST BE COMPLETE AND
ACCEPTED BY THE CITY
BEFORE ISSUING OCCUPANCY
PERMIT
Initial Review
Planning Review
Public Works Review
Public Works Review
Public Works Review
03fi2t2003
12t2312002
12t23t2002
03n7t2003
04nU2003
03n7t2003
12t2612002
03t20/2003
04nu2003
APP LLH
PEND
PJO
PJO
PJO
WE
WE
APP
Paee 4 of 8
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-7 26-37 69 lnspection Line
PERMIT NO: COM2002-01391ISSUED: 09/18/2003APPLIEDz 1211912002EXPIRES: 06/0812004VALUE: $ 298,000.00
Revised Plan Review - Fir 0410312003 0411712003 OK GRG
Revised Plan Review - Fir 0711712003 07t3U2003 OK GRG
Plan Review revisions. Subway
restaurant portion only. Job
#COM2002-01391. A-3 occupancy,
V-N construction, 3,000 sq. ft.
Exit signs described and shown on
plans. Will verify on inspection
Means of egress lighting described
on plans. Verify on inspection.
The I footcandle requirement for
egress lighting described on plans;
will require a special inspector to
verify and submit report to
Springfield Fire Marshal's Office
Main exit door sign "THIS DOOR
TO REMAIN OPEN DURING
BUSINESS HOURS" described in
plans. Will verify on inspection.
Address numbers will need to be
applied only to Subway restaurant.
Other restaurant will require
separate address per Lisa Hopper.
Fire extinguishers shown on plans;
rating listed; height detail shown.
Verify on inspection.
Plan Review: 2nd revision of
Subway + shell for second tenant.
Job #COM2002-01391.
Plan review comments on lst
revision still apply. 2nd revision
plans show second address number
for shell portion of building. WiIl
verify on inspection.
Revised grading/storm drainage
plan
Revised grading/storm drainage
plan
Revised PIan Review - Pu
Revised Plan Review - Pu
Revised Plan Review - Str
Revised Plan Review - Str
04t03t2003
04t08t2003
04t03t2003
04t08t2003
04t2u2003
04nU2003
04n4t2003
04n4t2003
APP
APP
DON
APP
PJO
PJO
JMP
JMP
Paee 5 of 8
-iqt
\
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541-7 26-37 69 Inspection Line
Building/C ombination Permit
PERMIT NO: COM2002-01391ISSUED: 0911812003APPLIEDz 1211912002
EXPIRES: 06/0812004YALUE: $ 298,000.00
Revised Plan Review - Str 0711712003 07t30t2003 WE JMP
Revised Plans Received/Ro
Revised Plans Received/Ro
Structural Review
Structural Review
Structural Review
Structural Review
Structural Review
12t26t2002
0ur5t2003 01/08/2003 ro
02t07t2003
03n7t2003
02t07t2003 WE JMP
03t2U2003 WE JMP
06t05t2003 06/05/2003 APP JMP
Entire package was revised. AII
elevations have changed. Details
have been added and others deleted.
Dry wells (inadequate) and berm
required at dumpster confirmed by
Public Works. Called Robert Shaw
and told him I had asked the
building inspector to check for the
additional hold downs required by
the revisions to the south wall. Also
told him that I am still missing the
documentation saying that the roof
trusses have been checked for snow
drifting.
Revised grading/storm drainage
plan
Assigned to Dave Puent for decision
on plan reviewer. Decision will be
made on 12126102 and plans will be
fed ex'd or routed on that day
Received revised restaurant
equipment drawings dated 10-22-02
(3 sheets) and equipment details
dated 11-01-02 (3 sheets).
Faxed letter to Robert Shaw
21712003 with 6 requirements.
Faxed 2nd Review document to
Robert Shaw today. See attached
document.
Robert Shaw submitted a memo
appealing for a relaxation of the
standard requiring a rated North
wall based on the premise that the
closest building to this wall will be at
least a quarter of a mile away. Dave
Puent has approved the two 11'
windows in this wall as nonrated but
that the wall continue to be rated as
shown on the drawings. John
Pearson called Robert Shaw and
Robert gratefully accepted this
decision.
04t03t2003
04/08/2003
APP
APP
LLH
LLH
Paee 6 of 8
SPR}HGFITLD
Building/C ombination Permit
Status Issued
225 Fifth Street, Springlield, OR
541-726-3753 Phone
541-726-3676Fax
541-7 26-37 69 Inspection Line
PERMIT NO: COM2002-01391ISSUED: 0911812003APPLIEDz 1211912002EXPIRES: 06/0812004VALUE: $ 298,000.00
Structural Review
SUB Review
SUB Review
SUB Review
SUB Review
12t23t2002
03n7t2003
0u13t2003
03t2u2003
06t20t2003 06t20t2003 wE JMP Tom Marx delivered 2 truss
drawings and 4 calculation sheets. I
reviewed and called Robert Shaw
and asked that he supply a
document from the engineer of
record that the proposed trusses
have been reviewed to carry the
snow drift loads, as well as
equipment and piping loads. Also
notified Tom Marx.
See Attached Documents.
Document Faxed lll312003
Corrected and accurate IMC
information submitted. Pass IfVAC
code review.
Pass Building Envelope. Incomplete
information submitted on oboslete
code forms was provided for HVAC
equipment RL Shaw Architect, is to
forward HVAC equipment specs
curretn energy code forms by next
week. No current accurate lighting
information has yet been provided.
Received updated lighting
information. Pass energy code
review
WE JF
POK JF
03fi7t2003 03n9t2003 POK JF
04n7t2003 0411712003 APP JF
To Request an inspection call the 24 hour recording at 726-3769. All inspection requested before 7:00 a.m.
witl be made the same working day, inspections requested after 7:00 a.m. will be made the following work
day.
I
)
3
Ufer Electrical Ground: Install ground rod at footing and call for inspection in conjunction with footing and/or
foundation inspection.
Footing: After trenches are excavated.
Slab: To be made after all inslab building service equipment, conduit piping and other equipment items are in
place but prior to concrete.
Shear Wall Nailing: Before covering sheathing with finish materials.
Framing Inspection: Prior to cover and after all rough in inspections have been approved.
Wall Insulation: Prior to cover.
Ceiling Insulation: Prior to cover.
Roofing: Prior to installing any roof covering.
Drywall: Prior to taping.
Masonry:
Bolts Installed in Concrete: To be done by a State Certilied Special Inspector. Provide inspection test reports to
City Building Inspector.
Roof Sheathing/|.lailing: Before covering sheathing with finish material.
Glu-Lam Beams: Inspection Certificate by an approved agency to be provided to City Building Inspector prior to
placement.
Paee 7 of 8
4
5
6
7
8
9
10
11
l2
13
Reorrired fnsnections
L.
CITY F
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541 -7 26-37 69 Inspection Line
PERMIT NO: COM2002-01391ISSUED: 09/18/2003APPLIED: 1211912002EXPIRES: 06/0812004VALUE: $ 298,000.00
14 Ceiling Grid: After drywall approval but prior to cover.
15 Hold Downs Installed: Special Inspection performed prior to placement of concrete. Provide report to City
Building Inspector.
16 Final Fire Department. After all requirements of the Fire Department have been met.
17 Final Building: After all Conditions have been completed as required on Development Agreement.
18 Final Building: After all required inspections have been requested and approved and the building is complete.
19 Rough Grading: After gravel is in place but prior to placing concrete.
20 Final Paving: After paving is complete.
2l Underground Plumbing: Prior to filling the trench and including required testing.
22 Rough Plumbing: Prior to cover and including required testing.
23 Water Line: Prior to filling trench and including required testing.
24 Sanitary Sewer Line: Prior to filling trench and including required testing.
25 Storm Sewer Line: Prior to filling trench.
26 Final Plumbing: When all plumbing work is complete.
27 Rough Mechanical: Prior to Cover
28 Final Mechanical: When all mechanical work is complete.
29 Rough Electric: Prior to Cover
30 Electric Service: Approval required prior to utility company energizing service.
31 Final Electric: When all electrical work is complete.
32 Rough Grading: After gravel is in place but prior to placing concrete.
33 Final Paving: After paving is complete.
34 SUB Concrete Slab: Prior to and following pour.
35 SUB Insulation Vapor Barrier: To be called for at the same time as the SUB framing inspection.
36 SUB Framing: Following City Framing inspection approval
37 SUB Final: After all required energy inspections have been requested and approved.
38 SUB Plumbing: Following City Rough Plumbing inspection approval and prior to cover.
39 SUB Mechanical: Following City Rough Mechanical inspection approval and prior to any cover.
40 SUB Ceiling Grid: Interior Lighting
4l SUB Exterior Lighting
42 Temporary Electric: Approval required prior to Utility Company energizing pole.
43 Backflow Device: Prior to covering and provide a copy of the test report on site at the time of inspection.
By signature,I state and agree, that I have carefully examined the completed application and do hereby certify that all
information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with
the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and
that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety.
I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project.
I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the
street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all
times during construction.
Owner or Contractors Signature
Page 8 of8
Date
ral
225 Fifth Street
Springfield, Oregon 97 477
541-726-3759 Phone
City of Springfield Official Receipt
Development Services Department
Public Works Department
Receipt #: 120020000000000257 1 Date: 1210812003 3:03:41PM
coM2002-01391
coM2002-01391
coM2002-01391
coM2002-01391
Backflow Device
Minimum/Adj ustrnent Plumbing
+ 7Yo State Surcharge
+ l0%o Administrative Fee
28.00
17.00
3. l5
4.50
Item Total:$52.6s
Type ofPayment Paid By Received By Batch Number Authorization Number How Received Amount Paid
Check DAKOTALANDSCAPE dlm 683 In Person
Payment Total:
$52.6s
$52.65
225 FIFTH STREET . SPRINGFIELD, OR97477 . PH:(541)726-3753 o FAXi
E LE CTRI CAL P E RM IT APP LI CATI O N
Ciry Job Number 0*n-AnB.-otz1 t Date a tt -03 Zonins
.ir9l
the following
la nd use
ljrte _
1 3
lb1'l n'\^ lun-> tc
LEGAL DESCRIPTION
11'o3. 7ca. 3t D S-ro-D
A.
C.
D.
E.
JOB DESCRIPTION
in;t riot: lx: ,rd*ry
Permits are non-transferable urJ{*pi." if work is
not started within 180 days of issuance or if work is
Suspended for 180 days.
Service Included
1000 sq. ft. or less
Each additional 500 sq. ft. or
portion thereof
Each Manufact'd Home or
Modular Dwelling Service or
Feeder
200 Amps or less
201 Amps to 400 Amps
401 Amps to 600 Amps
601 Amps to 1000 Amps
Over 1000 Amps/Volts
Reconnect Only
Installation, Alteration or Relocation
200 Amps or less
201 Amps to 400 Amps
401 Amps to 600 Amps
Over 600 or 1000 Volts see "B" above.
New Alteration or Extension Per Panel
One Circuit I
Each Additional Circuit or with
Service or Feeder Permit
$106.00
$ 19.00
$s0.00
,
Electrical Contractor Reynolds Electric
Address 2175 w 2rfi
City !\:Sene Phone 343-7297
Supervisor License Number 25205
Expiration Date IO-I-04
Constr. Contr. Number 17252
Expiration Date 2-8-05
Signature of Supervising Electrician
Name
Address ,o
City Phone
owNERrNsrALLArroN N[TlcE:
s 63.00
$ 7s.00
$125.00
s 163.00
$375.00
$ s0.00
$ 50.00
$ 69.00
$100.00
Pump or irrigation
Sign/Outline Lighting
Limited Energy/Residential
$ 43.00
$ 3.00
$ s0.00
$ 50.00
s 25.00
4:
a
rhe installation is being made on p'op[H]$ I'hitf,,ilt$HAlL EXFiSEdEil*d&WOftlGrcid $ 4s.00
is not intended for sale, lease or rent. AU [H0RIZED UNDFfl,trHS,ffi&MI[il&Alg Tnspection Fee is $45.00 * Surcharges
Owners Signature:
COMMENCED OR II
ANY 180 OAY PERI
os7%6 State Surcharge
10% Administrative Fee
TOTALInspection Request: 726-3769
S
Shared Driv{T:/Building Forms,/Electrical permit Application l{3.doc
CITY OF OREGON
. ,ST'ALI;4?IIO}T "LOCAT'ION OFT!
$+-n-r^ " ,, PArstkur-r-
-Q
New'iResid ential'' iii ngle or,Multi,.Fa,mill: pnr d wel I i n[ u n i t.
z4
CO}{TRACTORINS,?HIL.{,4ruOIrSNE.Y B.Services or Feeders - Ilrstallalinn. Alterations or Relocafion:
Temporarf S*rr.ices or FCederi
Ilrirnch Circuits
o
,[fiscellarreous ({i'ervice/feā¬der not hrclnderl} :-Eu*n Iirstallation
x
ll .60
5(\7+.
225 Fifth Street
Springfield, Oregon 97 477
541-726-3759 Phone
City of Springlield Official Receipt
Development Services Department
Public Works Department
Receipt #:2200200000000001544 Date: 0911812003 8:41:48AM
coM2002-01391
coM2002-01391
coM2002-01391
coM2002-0r391
Add, Alter, Extend Circ
Add, Alter, Extend Circ Ea Add
+ lYo State Surcharge
+ l|oh Administrative Fee
43.00
12.00
8.05
I 1.50
Item Total:$134.ss
Type of Payment Paid By Received By Batch Number Authorization Number IIow Received Amount Paid
CreditCard ALLEN REYNOLDS lkw 6777 018545 In Person
Payment Total:
$134.ss
$134.s5
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541-7 26-37 69 Inspection Line
GFIELD
Building/Combination Permit
PERMIT NO: COM2002-01391ISSUED: 0911812003APPLIED: 1211912002EXPIRES: 03/1812004VALUE: $ 141,000.00
SITE ADDRESS: 1657 Mohawk Btvd
ASSESSOR'SPARCELNO.: 1703253105800
PROJECT DESCRIPTION: Subway + additional restaurant
Springfield TYPE OF WORK:
TYPE OF USE:
Restaurant
New Commercial
Owner:
Address:
HAMMER BROTHERS LLC
PO BOX 2266 EUGENE OR 97402
Contractor Type
Architect
General
Electrical
Mechanical
Plumbing
Sewer
Contractor
ROBERT SHAW
MARK DORMAN CONSTRUCTION LLC
ROSE CORPORATION
COMMERCIAL AIR INC
EUGENE EXCAVATION & PLUMBING
MORSE BROS INC
License Expiration Date
147257
54431
110075
r38003
03t2U2005
09t30t2004
12n8t2005
03t07t200s
Phone
541-485-4963
54r-501-s985
541-686-0905
5414614821
541-988-0868
541-451-5141
CONTRACTOR INFORMATI(
# of Buildings:
Primary Occupancy Group:
Secondary Occupancy Group:
Primary Construction Type
Secondary Construction Type:
# of Bedrooms:
SETBACKS
Frontyard Setback:
Side I Setback:
Side 2 Setback:
Rearyard Setback:
Solar Setbacks:
Street Improvements:
Storm Sewer Available:
Special Instruction:
# of Stories:
Height of Structure
Type of Heat:
Water Type:
Range Type:
Energy Path:
Overlay Dist:
# Street Trees Rqd:
Paved Drive Rqd:
oh of Lot Coverage:
A-3
B
VN
YN
Lot Size:
Sq Ft lst Floor:
Sq Ft 2nd Floor:
Sq Ft Basement:
Sq Ft Garage/Carport
Sq Ft Other:
Impervious Surface Area:
3,000
REQUIRED PARKING
Total:
Handicapped:
Compact:
Sidewalk Type:
Downspouts/Drains: To Storm Sewer
Notes:
)r
Page I of8
Fullv Improved
Yes
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541 -7 26-37 69 Inspection Line
PERMIT NO: COM2002-01391ISSUED: 0911812003APPLIED: 1211912002EXPIRES: 03/1812004VALUE: $ 141,000.00
Description
Bid Amount
Paving
Type of Construction
Use Bid Amount
Use Bid Amount
$ Per Sq Ft
or multiplier
$1.00
$1.00
Square Footage
or Bid Amount
240,000.00
58,000.00
Value
$240,000.00
$58,000.00
$298,000.00
Date Calculated
12119t2002
04n8t2003
Amount Paid
Total Value of Project
Date PaidFee Description
Plan Review Comm/Ind/Public
-Mechanical Issuance Fee-
+ l0o/o Administrative Fee
+ l0o Administrative Fee
+ 10'J6 Administrative Fee
+ 7Vo State Surcharge
+ 7Vo State Surcharge
Addressing Assignment
Air Handling Unit Up to 10,000
Building Permit
Curbcut - Additional Driveway
Curbcut Permit
Encroachment Permit
Fixture
Furnace - up to 100,000 btu
Gas Outlets 1-4
Paving
Plan Review Comm/Ind/Public
Plan Review Fire & Life Safety
Sanitary Sewer - lst 50 Feet
Sanitary Sewer - Improvement
Sanitary Sewer - Reimbursement
Sanitary Sewer Each Addtl 100'
SDC MWMC Administration
SDC MWMC Improvement
SDC MWMC Reimbursement
SDC Sanitary/Storm Admin
SDC Transpo Admin
SDC Transpo Improvement
SDC Transpo Reimbursement
Sidewalk Repair Permit
Storm Drainage Impervious Area
Storm Sewer - lst 50 Feet
Storm Sewer Each Addtl 100'
Temp Power 200 amps or less
Receipt Number
1200200000000000434
1200200000000001068
1200200000000001068
r200200000000001068
1200200000000001068
1200200000000001068
120020000000000r068
1200200000000001068
1200200000000001068
1200200000000001068
r200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
r200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
r200200000000001068
120020000000000r068
1200200000000001068
r200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001068
$663.42
$10.00
$s.00
$40.19
$160.57
$3.50
$84.27
$8.00
$24.00
$698.90
$30.00
$7s.00
$120.00
$210.00
$36.00
$4.00
$401.8s
$-86.61
$354.96
$4s.00
$9s7.03
$1,259.13
$28.00
$10.00
$241.57
$4,062.34
$384.27
$9s3.46
$13,039.28
$2,955,24
$r0.00
$4,230.00
$4s.00
$42.00
$50.00
t2n9t02
4tzst03
4t25t03
4t2st03
4t2st03
4t2st03
4t2st03
4t25t03
4tzst03
4t25t03
4t2st03
4t25t03
4t2st03
4125103
4t25t03
4t2st03
4t25t03
4125t03
4t2st03
4t25t03
4t25t03
4t25t03
4t25t03
4/2st03
4t25t03
4t25t03
4t25t03
4t2st03
4t25103
4t2st03
4tzst03
4t25t03
4tzst03
4t25103
4t25t03
Fpps Peid
Paee 2 of 8
\tI
Valuation Description I
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541 -7 26-37 69 Inspection Line
PERMIT NO: COM2002-01391ISSUED: 0911812003
APPLIEDz 1211912002
EXPIRES: 03/1812004VALUE: $ 141,000.00
Vent f,'an
Water Line - lst 50 Feet
Water Line - Each Addtl 100'
+ l[Vo Administrative Fee
+ 7oh State Surcharge
Add, Alter, Extend Circ Ea Add
Perm Serv/Fdr 201 to 400 amps
Refund - Admin Fee
+ l0oh Administrative Fee
+ 7o/o State Surcharge
Add, Alter, Extend Circ
Add, Alter, Extend Circ Ea Add
Total Amount Paid
$12.00
$4s.00
$14.00
$16.50
$11.55
$90.00
$75.00
$-40.19
$11.50
$8.05
$43.00
$72.00
$31,513.78
4t2st03
4t2st03
4t25103
5/8/03
5/8/03
5/8/03
5/8/03
sn2t03
9/18/03
9/18/03
9/18/03
9fi8t03
1200200000000001068
1200200000000001068
1200200000000001068
1200200000000001 148
120020000000000r r48
1200200000000001 148
r20020000000000r 148
voucHER #61998
2200200000000001544
2200200000000001544
2200200000000001544
2200200000000001544
Plan Reviews
Fire Department Review 1212312002 0U27t2003 0K GRG Plan Review of proposed Subway
restaurant. Additional restaurant
plans not included. A-3 occupancyg
V-N construction.31000 sq. ft.
Provide exit signs meeting the
requirements of 1998 Oregon
Structural Specialty Code 1003.2.8.
Provide means of egress lighting
meeting the requirements of OSSC
1003.2.9.
Egress lighting shall be maintained
at a minimum of I footcandle at
floor level per 1998 OSSC 1003.2.9.
On the main exit door, provide sign
stating'TTHIS DOOR MUST
REMAIN UNLOCKED DURING
BUSINESS HOURS.'' (OSSC
1003.3.1.8, exception 1)
Post address numbers visible from
the street (OSSC 502; Springfield
Uniform Fire Code 90f .4.4)
Provide 2-A:10-B:C rated fire
extinguisher within 75 feet of travel
distance within the restaurant.
(surc 1002.r)
Paee 3 of 8
--'_:
Status Issued
225 Fifth Street, SPringfield' OR
541-726-3753 Phone
541-726-3676Fax
541-726-37 69 Inspection Line
Building/Combination Permit
PERNIIT NO: COM2002-01391
ISSUED: 09/18/2003
APPLIEDz lzll9/2002
EXPIRES: 03/18/2004VALUE: $ 141,000.00
Initial Review
Initial Review
Planning Review
0311212003
12t23t2002
12t23t2002
03n7t2003
04fiu2003
03n7t2003
12t26t2002
03t2012003
04nu2003
APP LLH
PEND
12t20/2002 12t23t2002 APP LLH Needed to verify location and
address assignment with Jim
Donovan.
Planner is Jim Donovan, DRC
2002-070226. Site PIan Review is
not complete yet as of l2l3ll02.
Site Plan Not Complete
Site Plan Not Complete
THE ASSOCIATED PUBLIC
IMPROVEMENT PROJECT
MUST BE COMPLETE AND
ACCEPTED BY THE CITY
BEFORE ISSUING OCCUPANCY
PERMIT
Plan Review revisions. Subway
restaurant portion only. Job
#COM2002-01391. A-3 occupancy,
V-N construction,3,000 sq. ft.
Exit signs described and shown on
plans. Will verify on inspection
Means of egress lighting described
on plans. Verify on inspection.
The I footcandle requirement for
egress lighting described on plansl
will require a special inspector to
verify and submit report to
Springfield Fire Marshal's Office
Main exit door sign TTTHIS DOOR
TO REMAIN OPEN DURING
BUSINESS HOURS" described in
plans. \ilill verify on inspection.
Address numbers will need to be
applied only to Subway restaurant.
Other restaurant will require
separate address per Lisa Hopper.
Fire extinguishers shown on plans;
rating listed; height detail shown.
Verify on inspection.
WE
WE
APP
PJO
PJO
PJO
Revised Plan Review - Fir 0410312003 04n7t2003 OK GRG
Pase 4 of 8
h
Public Works Reyiew
Public Works Review
Public Works Review
F PRIN
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541 -7 26-37 69 Inspection Line
PERMIT NO: COM2002-01391ISSUED: 0911812003APPLIEDz 1211912002EXPIRES: 03/1812004VALUE: $ 141,000.00
Revised Plan Review - Fir 0711712003 07t3U2003 OK GRG
Revised Plan Review - Pu
Revised Plan Review - Pu
Revised Plan Review - Str
Revised Plan Review - Str
Revised Plans Received,/Ro
Revised Plans Received/Ro
Structural Review
Structural Review
Structural Review
Structural Review
12t26t2002
0u15t2003 01/08/2003 Io
Plan Review: 2nd revision of
Subway + shell for second tenant.
Job #COM2002-0r39r.
Plan review comments on lst
revision still apply. 2nd revision
plans show second address number
for shell portion of building. WilI
verify on inspection.
Revised grading/storm drainage
plan
Revised grading/storm drainage
plan
Entire package was revised. AII
elevations have changed. Details
have been added and others deleted.
Dry wells (inadequate) and berm
required at dumpster confirmed by
Public Works. Called Robert Shaw
and told him I had asked the
building inspector to check for the
additional hold downs required by
the revisions to the south wall. Also
told him that I am still missing the
documentation saying that the roof
trusses have been checked for snow
drifting.
Revised grading/storm drainage
plan
Assigned to Dave Puent for decision
on plan reviewer. Decision will be
made on 12126102 and plans will be
fed ex'd or routed on that day
Received revised restaurant
equipment drawings dated 10-22-02
(3 sheets) and equipment details
dated 11-01-02 (3 sheets).
Faxed letter to Robert Shaw
21712003 with 6 requirements.
Faxed 2nd Review document to
Robert Shaw today. See attached
document.
04103t2003
04t08t2003
04103t2003
04/08t2003
02t07t2003
03n7t2003
04t2u2003
04fiU2003
04n4t2003
04n4t2003
04103t2003
04t08t2003
02t07t2003
03t2u2003
DON
APP
PJO
PJO
Revised Plan Review - Str 0711712003 0713012003 wE JMP
APP
APP
JMP
JMP
LLH
LLH
JMP
APP
APP
WE
WE
Paee 5 of 8
JMP
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541-7 26-37 69 Inspection Line
Building/C ombination Permit
PERMIT NO: COM2002-01391ISSUED: 0911812003APPLIEDz 1211912002EXPIRES: 03/1812004VALUE: $ 141,000.00
Structural Review
Structural Review
SUB Review
SUB Review
SUB Review
SUB Review
06t0st2003 06/0s/2003 APP JMP
06t20t2003 06t20t2003 WE JMP
Robert Shaw submitted a memo
appealing for a relaxation of the
standard requiring a rated North
wall based on the premise that the
closest building to this wall will be at
least a quarter of a mile away. Dave
Puent has approved the two 111
windows in this wall as nonrated but
that the wall continue to be rated as
shown on the drawings. John
Pearson called Robert Shaw and
Robert gratefully accepted this
decision.
Tom Marx delivered 2 truss
drawings and 4 calculation sheets. I
reviewed and called Robert Shaw
and asked that he supply a
document from the engineer of
record that the proposed trusses
have been reviewed to carry the
snow drift loads, as well as
equipment and piping loads. Also
notilied Tom Marx.
See Attached Documents.
Document Faxed lll3l2003
Corrected and accurate IfVAC
information submitted. Pass IfVAC
code review.
Pass Building Envelope. Incomplete
information submitted on oboslete
code forms was provided for HVAC
equipment RL Shaw Architect, is to
forward IMC equipment specs
curretn energy code forms by next
week. No current accurate lighting
information has yet been provided.
Received updated lighting
information. Pass energy code
review
12t23t2002
03n7t2003
0U13t2003
03t2u2003
WE JF
POK JF
03n7/2003 03n9t2003 POK JF
04n7t2003 04n7t2003 APP JF
To Request an inspection call the 24 hour recording at 726-3769. All inspection requested before 7:00 a.m.
will be made the same working day, inspections requested after 7:00 a.m. will be made the following work
day.
I Ufer Electrical Ground: Install ground rod at footing and call for inspection in conjunction with footing and/or
f oundation insPection.
2 Footing: After trenches are excavated'
Paee 6 of 8
Renuired fnsnecfions
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541-7 26-37 69 Inspection Line
PERMIT NO: COM2002-01391ISSUED: 0911812003APPLIED: 1211912002EXPIRES: 03/1812004VALUE: $ 141,000.00
3 Slab: To be made after all inslab building service equipment, conduit piping and other equipment items are in
place but prior to concrete.
Shear Wall Nailing: Before covering sheathing with finish materials.
Framing Inspection: Prior to cover and after all rough in inspections have been approved.
Wall Insulation: Prior to cover.
Ceiling Insulation: Prior to cover.
Roofing: Prior to installing any roof covering.
Drywall: Prior to taping.
Masonry:
Bolts Installed in Concrete: To be done by a State Certified Special Inspector. Provide inspection test reports to
City Building Inspector.
Roof Sheathing/l{ailing: Before covering sheathing with finish material.
Glu-Lam Beams: Inspection Certificate by an approved agency to be provided to City Building Inspector prior to
placement.
Ceiling Grid: After drywall approval but prior to cover.
Hold Downs Installed: Special Inspection performed prior to placement of concrete. Provide report to City
Building Inspector.
Final Fire Department. After all requirements of the Fire Department have been met.
Final Building: After all Conditions have been completed as required on Development Agreement.
Final Building: After all required inspections have been requested and approved and the building is complete.
Rough Grading: After gravel is in place but prior to placing concrete.
Final Paving: After paving is complete.
Underground Plumbing: Prior to filling the trench and including required testing.
Rough Plumbing: Prior to cover and including required testing.
Water Line: Prior to filling trench and including required testing.
Sanitary Sewer Line: Prior to filling trench and including required testing.
Storm Sewer Line: Prior to filling trench.
Final Plumbing: When all plumbing work is complete.
Rough Mechanical: Prior to Cover
Final Mechanical: When all mechanical work is complete.
Rough Electric: Prior to Cover
Electric Service: Approval required prior to utility company energizing service.
Final Electric: When all electrical work is complete.
Rough Grading: After gravel is in place but prior to placing concrete.
Final Paving: After paving is complete.
SUB Concrete Slab: Prior to and following pour.
SUB Insulation Vapor Barrier: To be called for at the same time as the SUB framing inspection.
SUB Framing: Following City Framing inspection approval
SUB Final: After all required energy inspections have been requested and approved.
SUB Plumbing: Following City Rough Plumbing inspection approval and prior to cover.
SUB Mechanical: Following City Rough Mechanical inspection approval and prior to any cover.
SUB Ceiling Grid: Interior Lighting
SUB Exterior Lighting
Temporary Electric: Approval required prior to Utility Company energizing pole.
4
5
6
7
8
9
10
11
t2
13
l4
t5
16
17
18
19
20
2l
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
4t
42
Pase 7 of 8
LD
Building/Combination Permit
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676Fax
541 -7 26-37 69 Inspection Line
PERMIT NO: COM2002-01391ISSUED: 0911812003APPLIEDz 1211912002EXPIRES: 03/1812004VALUE: $ 141,000.00
By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all
information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with
the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and
that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety.
I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project.
I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the
street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all
times during construction.
Owner or Contractors Signature Date