Loading...
HomeMy WebLinkAboutPermit Building 2002-10-24Status: Issued 225 Fifth Street, SpringfieH, OR 541-726-3753 Phone 541-726-3676 Fax 541:726-37 69 Inspection Line TY OF Buildin g/C ombination Permit PERMIT NO: COM2002-01239ISSUED: 1012412002APPLED: 1012412002E)0IRESz 0412412003VALUE: $ 7,590.00 SITE ADDRESS: l4l4 MOHAWK BLVD ASSESSOR'S PARCEL NO.: 1703253309900 PROJECTDESCRIPTION: Reroof Owner: FORD GRILL CAFE Address: l4l4 MOIIAWK BLVD SPRINGFIELD OR 97477 Springfield TYPE OF TYPE OF USE: ReRoof Repair Commercial Phone 541-746-s000 Contractor Type General Owner Contractor RIVER ROOFING INC FORD GRJLL CAFE License 79016 Expiration Date 0U06t2006 CONTRACTOR INFORMATI( BUILDING INFORMATI(r0 # of Buildings: Primary Occupancy Group: Secondary Occupancy Primary Construction Type Secondary Construction # of Bedrooms: SETBACKS Frontyard Setback: Side I Setback: Side 2 Setback: Rearyard Setback: Solar Setbacks: # of Stories: Height of Type of #Trees Paved Drive Rqd: oh ofLot Coverage: Size: Ft lst Floor: 2nd Floor: Basement: Ft Other: pervious Surf'ace REQUIRED PARKING Total: Handicapped: \t Type: poutVDrains \6 Street Storm Sewer Awilable: Special Instruction: Notes: Description Type of Construction $ Per Sq Ft Square Footage Total Value of Project lof2 tNFO LIC Value Date Calculated Valuation Description I Status: Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541:126-37 69 Inspection Line CITY OF SPRINGFIELD Building/C ombination Permit PERMIT NO: COM2002-01239ISSUED: 1012412002APPLIEDz 1012412002E)PIRES: 0412412003VALUE: $ 7,590.00 ['ees Paid Fee Description + 7%o State Surcharge + 87o Administrative Fee Building Permit Amount Paid Date $6.43 $7.34 $91.80 Receipt Number 1200200000000000125 1200200000000000125 1200200000000000125 Received By diu dib dib 10t24t2002 10t24t2002 t0t24t2002 Total Amount Total Fees Paid Prior ta 9130/02 $105.57 Plan Reviews To Request an inspection call the24 hour recording at 726-3769. All inspection requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following work day. I Roof Sheathing/l{ailing: Before covering sheathing with finish material. 2 Roofing: Prior to installing any roof covering. nsnecf ions By signature, I state and agree, that I have carefully examined the completed application and do hereby certiff that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. or Date io2''/-oL 2of2 Wtoffio,- liccnscNo.79016 -bondNo.130517 - lnsurcd 1484 5,. , REET 9rR.lNGFlELD, O? 97 477 (541) 7 +6-5OOO rAX (54r) 7 47 -7159 www.riv crroof in4,com 'LANE COII{TYS OLOE5T ROOFING COMPANY'il1CE1971 RIVER ROOFlr.rc. ll.rc. Pltinosal aird Contact Ford Attn:Cole 1 2002 Name 1414 Mohawk, Springflreld, Or 97477 FLAT ROOF AREAS 1. Tear off old roofing, clean grounds and gutters. 2. Replace vents and pipe flashings. 3. Install new scupper drain flashings. 4. Install new cap metal flashings. 5. Reflash walls as necessary. 6. Install four-ply hot mopped built up roof system with white mineral surface cap sheet. 7. Remove all Date i)PTION A: .Continued on next page.. 1AjtD Price good for 30 days. Workmanship guaranteed for two (2)-years. Manufacturer's roofing warra-nty is as stated above. During demolition debris may sift into attic areas, please take measure to cover valuables. For Visa-Mastercard, please add 3lo. Payment to be made as follows: fl fotat due upon completion. ffi Deposit of l0Vo with the balance due upon completion Any rotten material that needs replacing will be charged at cost plus 15%. Labor is charged at $40 per man per hour. Any alteration or deviation from the above specifications involving extra cost of material or labor wrll only be executed upon written or oral orders, and will become an extra charge over the sum listed above. River Roofing is not responsible if damage occurs during reroof ing due to roof vibration. ln the event that it becomes necessary to institute a lawsuit or to employ an attorney to collect any payment due River Roof ing ior labor or materials f urnished under thrs agreement or any modif ication to thii agreement, then you shall be liable to River Roofing for court costs and attorney's fees. A late payment charge of 2o/o will be added to past due accounts. A rebilling charge of $ 1 5 will be added to all past-due statements. flCOPY Respectf ully submitted,8-/'o -- te Acceptance You are hereby authorized to furnish all materials and labor required to complete the work specified in the above proposal. I agree to pay the amount specified above, according to the terms of this contract. AccePted bY, A d5 % Date Approved Price a/ Job Address Dear Customer, We propose to furnish all materials and perform all labor necessary to complete the following: siffi JohnsManville Specification 4GlC Four Ply Mineral Surlaced Fiber Glass Built-Up Boof. For use over JM insulation, approved decks or other approved insulations, on inclines of %" to 6" per foot (20.8 to 500 mm/m). For Begions 1,2 and 3 Materials per lfi) sq. ft. (9.3 m'?) oI Rool Area Concrete Primer lf required 1 gallon (3.8 liters) Felts: GlasPly Premier or GlasPly lV GlasKap or GlasKap Plus Asphalt (lnterply): Trumbull or other JM Approved Asphalt lncline per foot Asphalt Nominal Weight Up to 1"(25 mm) 170"E Type ll, Flat 92 lbs. (42 kgl 1"to 3" (25 to 76 mm) 190"F, Type lll, Steep 92 lbs. (a2 kg) $to 6" (76 to 152 mm) 220F,fype lV, Special Steep 92 lbs. (42 kg) 0 to 6"(0 to 152 mm) Perm{lop 92 lb.s. (42 kg) Approximate installed weight *74 .,2l8Jbs, {79 - 99 kg). .{ General This specification is for use over any type of approved structural deck which is not nailable and which offers a suitable surface to receive the roof. Poured and pre-cast concrete decks require priming with JM Concrete Primer prior to application of hot asphalt. Thrs specification is also for use over JM roof insulations or other approved rigid roof insulations, which are not nailable and which offer a surtable surface to install the roof. Specific written approval is required for any roof insulation not manufactured or supplied by JM. lnsulation should be installed in accordance with the appropriate JM lnsulation Specification detailed in the current JM Commercia/lndustrial Boofing Systems Manual. This specification can also be used in certain reroofing situations. Refer to the "Reroofing" section of the JM Commercial/ lndustrial Roofing Systems Manual. This specification is not to be used directly over poured or pre-cast gypsum or lightweight, insulating concrete fills. Design and installation of the deck and/or substrate must result in the roof draining lreely and to outlets numerous enough and so located as to remove water promptly and completely. Areas where water ponds for more than 24 hours are unacceptable and are not eligible to receive a JM Roofing Systems Guarantee. Note: All general instructions contained in the current JM Commercial/ lndustrial Roofing Systems Manual should be considered part of this s pecification. Flash ings Flashing details can be found in the "Bituminous Flashings" section of the JM Commercial/lndustrial Roofing Systems Manual. Application Note: 0n roof decks with slopes up to l" per foot (83.3 mm/m), the roofing felts may be installed either perpendicular or parallel to the roof incline. 0 n slopes over l' per foot (83.3 mm/m), ref e r to Paragraph 6.1 t of this section for special requirements. Using GlasPly Premier or GlasPly lV apply a piece 12"(305 mm)wide, then over that, one 24" (610 mm) wide, then over both, a full width piece. The following felts are to be applied full width, over-lapping the preceding felts by 24%" (627 mm) so that at least 3 plies of felt cover the base felVsubstrate at all locations. lnstall each felt so that it is firmly and uni- formly set, without voids, into the hot asphalt (within t25"F [t l4'C] of the EW) applied lust before the felt at a nominal rate of 23 lbs. per square (1.1 kg/m'?) over the entire surface. lnstallation over porous substrates such as roof insulation may require up to 33 lbs. per square (1.6 kg/m') of hot asphalt. Surfacing Prior to application of GlasKap, cut the cap sheet into handleable lengths (.l2 - l8 [3.66 m - 5.50 m]). Laythe material outonthe roof and allow itto relax and flaften. To accommodate a full width sheet, apply a mopping of hot asphalt, approximately 20'F (1 1'C) above the EVf, at a nominal rate of 23 lbs. per square (1.1 kg/m?). (The higher temperature of asphalt maximizes the bonding of the cap sheet to the ply felts.) Then flop the cap sheet into the hot asphalt. 0n subsequent courses, the cap sheet is positioned upside down, directly over the sheet in the preceding course such that the side lap area of the preceding sheet is exposed. Care should be taken to maintain 2" (51 mm) side laps and 6" (152 mm) end laps. Asphalt is applied in the same manner as before, making sure to also cover the 2" (51 mm) exposed side lap. Asphalt may also be applied to the exposed "upside down" cap sheet, prior to "flopping" it into the hot asphalt. The cap sheet must be firmly and uniformly set, without voids, into the hot asphalt with all edges and laps well sealed. Asphalt Asphalt should meet the requirements of ASTM D 3,l2. JM Guarantees require the use of Trumbull asphalt or another JM Approved Asphalt. Check with a JM Technical Services Specialist for special asphalt requirements in hot climates. For an identical copy of this specification, ask for RS-2046 3 plies I plv Asphalt Cap Sheet GlasKap or GlasKap Plus Mineral Surfaced End Laps Slaggered 3'Aparl (Min.) GlasPly Premier or GlasPly lV 11 r/i'Exposure 2" lap 6" End Lap -1 .q o I I 4Gl Non-Nailable Deck or Approved lnsulation Concrele Pramer (lf Required) 6-23 | ,u,oro Specifications t,tfil lohnsManville Class A 1. Deleted. 2.+Deck:C.15/3?-,, ...", lncline: I :-:visirrrr tn"u;r165qffiffilrAhffiift'ft'frftWmmmore layers Lotrns Manvitld*"Fieico". "Fesco-Foam-.'Fiber,Slgss Roof lnsu-lqtion", "lS0 1", "E'NRG'Y-2" or any UL Classified polyisocyanurate insulation. hot mopped or mechanically fastened in combindtion (optional) with l/2 in. " Betro-Fit" c ove r b o a rd, o r 3/*dnc#f€sq6.i, .over .polystyre n e.I Base Sheet One ply Type Gl 'rGlasPly Neor "GlasPJtt Premier", or Type G2 "Glas-Base" or "Ventsulaton", or,lDynaBase" (modified bitumen), nailed or hot mopped PIy Sheet Two or more plies Type Gf*Glasety U'1.1'GlasPly Premier", hot mopped. Surfacing: Gravel, crushed stone or sla$ithd hot roofing asphalt. 3 Deck: C-3i4 lncline:3 lnsulation (0ptional): Any thickness, one 0r more layers Johns Manville "Fesco", "Fesco-Foam", "Fiber Glass Roof lnsulation", "lS0 1", "E'NRG'Y-2" or any UL Classified polyisocyanurate insulation, hot mopped or mechanically fastened in combination (optional)with 1/2 in. ' -*--tetrq{if cover board, or 3/4 in. "Fesco" over polystyrele. .Jf;- Base Sheet: Type G2 "PermaPly 28" , "GlasBase" or "Ventsulation", or "DynaBase" (modified bitumenL nailed or hot mopped. Ply Sheet Two or more plies Type G1 "GlasPly lV", "GlasPly Premier", hot mopped. Surfacing: Gravel, crushed stone or slag and hot roofing asphalt. 4. Deck C-3/4 lncline:3 lnsulation (0ptional): Any thickness, one or more layers Johns Manville "Fesco", "Fesco-Foam", "Fiber Glass Roof lnsulation", "lS0 1 ", "E'NRG'Y-2" or any UL Classified polyisocyanurate insulation, hot mopped or mechanicallyfastened in combination (optional) with 1/2 in. "Retro-Fit" cover board, or 3/4 in. "Fesco" over polystyrene. Ply Sheet Three or more plies Type Gl "GlasPIy IV", "GlasPly Premier", nailed or hot mopped. Surfacing: Gravel, crushed stone or slag and hot roofing asphalt. 5. Deck NC lncline: l-U2 lnsulation(0ptional):Anythickness,oneormorelayersJohnsManville"Fesco","Fesco-Foam","FiberGlassRoof lnsulation","lS0 I", "E'NRG'Y-2" or any UL Classified polyisocyanurate insulation, hot mopped or mechanicallyfastened in combination (optional) with 1/2 in. "Retro-Fit" cover board, or 3/4 in. "Fesco" over polystyrene. Base Sheet: Type G2 "PermaPly 28" , "GlasBase" or "Ventsulation" or "DynaBase" (modified bitumen). nailed or hot mopped. Sur{acing: Type G3 "GlasKap", hot mopped. 6. Deck NC lncline: 1-1/2 lnsulation (0ptional): Any thickness, one or more layers Johns Manville "Fesco", "Fesco-Foam", "Fiber Glass Roof lnsulation", "lS0 1", "E'NRG'Y-2" or any UL Classified polyisocyanurate insulation, hot mopped or mechanically fastened in combination (optional) with 1/2 in. "Retro-Fit" cover board, or 3/4 in. 'Fesco" over polystyrene. Ply Sheet Two or more plies Type Gl "GlasPly lV". "GlasPly Premier", nailed or hot mopped. Surfacing: Type G3 "GlasKap". 7. Deck C-15132 lncline: I lnsulation (0ptional): Anythickness. one or more layers Johns Manville "Fesco", "Fesco-Foam", "Fiber Glass Roof lnsulation", "lS0 1", "E'NRG'Y-2" or any UL Classified polyisocyanurate insulation, in combination (optional)with l/2 in. "Retro-Fit" cover board, or 3/4 in. "Fesco" over polystyrene. Base Sheet: One ply Type Gl "GlasPly Premier" or "GlasPly lV", or Type G2 "PermaPly 28" , "GlasBase" or'Ventsulation", or "DynaBase" (SBS modified bitumen). mechanically attached or hot mopped. Ply Sheet One or more plies Type Gl "GlasPly Premier", "GlasPly lV", hot mopped. Surfacing: Type G3 "GlasKap", hot mopped. B Deck: C 15132 lncline: 1 lnsulation: Any thickness, one or more layers Johns Manville "Fesco", "Fesco-Foam", "Fiber Glass Roof lnsulation", "lS0 1", "E'NRG'Y 2" or any UL Classified polyisocyanurate insulation. 0ne layer of 112in. "Retro-Fit Board" may be placed on top of the above insulations but is not acceptable by itself. Base Sheet "PermaPly 28" , "GlasBase", "Ventsulation", "DynaBase", "GlasPly lV", "GlasPly Premier", nailed. Ply Sheet "DynaPly" or "DynaBase", hot mopped. Surfacing: Type G3 "GlasKap", hot mopped. 13-3