HomeMy WebLinkAboutPermit Correspondence 1984-08-02SPRINGFIELE' CIIY OF SPRINGFMLD Department of Public Works August 2, 1984 Mr. Frank Krebs 610 East Broadway Eugene, 0regon 9740L RE: Occupancy Inspection at 1216 Mohawk Blvd., Springfield, Oregon Dear Frank, At your request the City of Springfield Building Safety Division conducted an inspection on July 17, 1984 of the forner Gingerbread House Restaurant and an adjacent vacant lease space formerly occupied as Phone Center. The intent of this inspection was to determine the current condition and suitability of this vacant lease space for your proposed occupancy as a restaurant and lounge fa- cility. The inspection revealed the following items for your consideration: STRUCTURAL AND FIRE SAFETY The proposed interior modifications do not appear to have any effect on the structural integrity of the building since proposed door openings are in wa1Is that are probably non-bearing. Prior to cutting in any new openings in these walls, however, it will be necessary for you to verify if the interior walls at those points are providing any support for the existing roof structure. If the wa1ls are non-bearing, a 4 x 4 or equivalent header is adequate for the proposed openings. If the wal1s are found to be bearing, it will be necessary to determine the contributary load at the proposed openings, and size headers accordingly. Please coordinate this work with the City Struc- tural Inspector, Dave Puent. Exit doors, hardware, illumination and signage shall comply with the require- ments outlined in Chapter 33 of the State Structural Specialty Code and Fire and Life Safety Regulations, 1983 Edition, for A-3 Occupancy classification. Have your architect coordinate these requirements with the City Plans Exaniner, Lorne Pleger, and Fire Marshal, Mike Hudman as remodel plans are being prepared. The condition of the existing smoke detection system shall be verified, and the system shall be restored to working order as required by the Fire Marshal. Coordinate recommended locations for fire extinguishers with the Fire Marshal prior to occupancy. 1 ) 3 4 225 North 5th Street a Springfield, Oregon 97477 a 503/726-3753 1 I.{r. Frank Krebs Occupancy Inspection 1216 Mohawk Blvd August 1, 1984 Page 2. PLUIUBING No problems were found in the existing plunbing system. Coordinate any proposed plumbing modifications or additions with City Plumbing Inspector, Denny Bordeaux. MECHANICAL No problems were found in the existing nechanical systems. Your anticipated addition of gas-fired kitchen equipment will require nodification of metering and gas piping within the existing building to serve this area. Coordinate anticipated gas piping and metering requirements with Northwest Natural Gas, and the City Mechanical Inspector, Denny Bordeaux. The lease space formerly occupied by the Phone Center and that of the former Ginger- bread House are served by different HVAC systems. Coordinate any anticipated nodi- fication to these systems and their controls with the Mechanical Inspector and the Building Owner to assure adequate service to these lease spaces as well as the other existing lease tenants who may also be served by the same unit. ELECTRICAL The existing electrical service and wiring is compatible with the proposed use, and appears to require only minor repair and maintenance. The former Phone Center space is served by a different electric panel than the forner Ginger- bread House. For this reason, it will be necessary for you to verify the existing seryice locations and circuitry to assure that ready access is pro- vided to all service equipment. If you anticipated changes in electrical service, circuitry, controls, etc. have your electrical contractor coordinate such changes with the City Electrical Inspector, Jim Matteson. ZONING CODE The City Zoning Code requires that one parking space be provided for every three (3) seats in a restaurant or bar. The former parking provision for the lease spaces you intend to occupy based on an occupant load of 176 persons for the former Gingerbread House, was never in compliance with the current Zoning Code. If you do not exceed the occupant load and parking demands of the former tenants, we will not require the provision of additional parking spaces at this time, however, if your occupant load exceeds that of the former tenants you will be required to provide additional parking for the increased demand based on the 1 space per 3 seat ratio. 1 1 1 Mr. Frank Krebs Occupancy Inspection 1216 Mohawk BIvd. August 1, 1984 Page 3. Permits and inspections are required for all of the above mentioned itens. Specific questions should be addressed to the appropriate inspector at 726-3753. Sincerely, Lorne W. Pleger Senior Plans Examiner cc: LWP/Ih Skip Fleek, 1335 Market Street Springfield, Oregon 97 477