Loading...
HomeMy WebLinkAboutPermit Correspondence 1986-04-16*d-- SPRINGFIELD CIIY OF SPRINGFIELD Office of Community and Economic Development April 16, 1986 Mr. John Gregor 975 Oak Street Suite 1010 Eugene, Oregon 974OL Subject: Courtesy Inspection aL 844 Mill Street, Springfield, Oregon. Dear [{r. Gregor: .{t the request of several of your tenants, The Springfield Building SafetyDivision conducted an inspection of your property at the above address. Theinspection revealed several items of concern tvhich do not meet the minimumCity Housing Code Requirements, and need to be comected. They consist of the foliorving: Steps at most of Lhe units have been ropaired by the use of plywood overthe existing stair tread. This creates a safety hazard by changing therelative height of the stair risers (wertical distance between steps). The )rousing code does not permit a difference greater than 3/8 inch betweenthe highest and the lowest risers in a stairway. The wood steps are cieteriorating in many locations, including those rnen- tioned in #1 above, and require repair or replacemenl. Structural settlement has occurred under landings and stair stringers, creating uneven surfaces in the following locations:a. Top landing and wood stair at unit #13-18 (The wood post and stringerare in direct contact with the ground, which contributes to the condition). b. The outside stair stringer at unit #9-10.c. The landing at urril #22-24. 4.Wood Supports are rotted or deteriorating rapidly in the following locations:a. Stair stringers at unit #13-18.b. Stair stringers at the right side of unit #E-Hc. Header is split at the top of the stair to unit #I-O.d. Ilandrail is leaning out at the front stair to unit #9-10.e. Header is rotted at the top of the front stair to unit #zz-24.f. Stair stringers are rotting and separating from the intermediateIanding of the front stair to unit #y-(B-z). 5.The handrail to unit #11 is missing a vertical rail, allowing an excessiveopening in the railing, which is potentially hazardous to children who may usethe stair. 1 2. 3. 225 North Sth Street Springfield, Oregon 97477 503/726-3753 Mr. John Gregor April 16, 1986 page 2 Due l.o the potentially hazardous nature of items # 1 and 2, those comections must be completed within the next 15 days, or procedures necessary to cause the buildings to be vacated may be initiated. The remaining items must be corrected within 30 days from the date of this letter. Permits will be required for the above repairs, and may be obtained from this office. Please direct all inquiries to the Springfield Building Safety Division aL 726-3759.trk* Structural Inspector cc.Dave Puent, Building Official