HomeMy WebLinkAboutPermit Correspondence 1996-03-13CITY OF OREGO'V SPRINGFIELf' D EVE LOP M ENT S ER VIC ES DE PARTM E NT 225 FIFTH STREET SPRINGFIELD, OR 97477 (541 ) 726-375s FAX (541) 726-368e March 13,1996 Douglas Weiss 413 West Grand Avenue Escondido, CA92025 Subject: Occupancy Inspection at 510 Mill Street, Springfield, Oregon. Proposed Use: Electronics repair Dear Mr. Weiss, At your request, the Community Servces Division/Building Safety conducted an inspection of the building at the above address. The purpose of the inspection was to determine the suitability of the building for the proposed use as indicated. Based on the proposed occupancy, the existing conditions which are mentioned below do not meet the minimum Building Safety Code requirements. Corrective measures must be taken prior to occupancy to install, repair, replace or modifu the following items in order for the building to conform to applicable safety codes: Structural Exterior walls less than 20 feet from the property line are required to meet one-hour fire resistive standards. The North wall of the structure is not in compliance with this requirement. Architectural barriers that limit the accessibility or use of the building shall be removed up to an expenditure of 25o/o of the total project cost. The net free attic ventilation area shall not be less than 1/150 of the area of the attic. walls shall be insulated to R-l1 and ceilings to R-l9. contact John McCoy at Springfield utility Board at744-3777 in regards to lighting requirements. Install one 2,A.-1OBC fire extinguisher. Electrical A separate electrical service or sub panel will be required for the structure. All electrical circuits shall be wired with a #12 wire and 20A circuit breakers. A separate 20A circuit shall be provided for any sign. The above items are requirements for the existing structure only. Other items such as parking, paving, site improvements, sidewalks, etc., have not been addressed as part of this inspection and may be required. Please contact the Planning Division of this ofFrce regarding any necessary improvements to the site. Building permits must be obtained for the above items which involve repairs or modifications to the structural, electrical, plumbing or mechanical systems of the building and for any additions or revisions you wish to make to the building. If you need any further information or have any questions regarding the above requirements, please contact me between the hours of 8:00-9:00 a.m., 1:00-2:00 p.m. or 4:00-4:30 p.m. at 726-3759. Y"tt' Jmq Tom Marx Building Inspector cc:Dave Puent, Community S ervices Manager/B uilding Official Bruce Bamforth, owner o .po 0)o a) o this Consult postmaster for fee. v Service EI Registered fPCertified E Express Mail E lnsured E Retum Beceipt lor Merchandise E COD 8. Addressee's and fee is paid) I also wish to receive thsrollowing services (for an extra lee): 1. E Addressee,s Address 2. E Resticted Delivery os o EoIo, Eoo a^(d url trlolol4 z\ trl 3lH rul trl Nuqlnsb ,au55 *tz vk* braYrd ftYI- Escry^atao ,uA otrct* 3.to: 5 BY: 6. x o fo JE6 .tr 5o o PS Form 11,1994 \ a,oto @ a-aooE First-Class Mail Postage & Fees Paid USPS Permit No. G-l0ill ll l Urureo Srnres Posru Senvrce ll'1,,f ,,, l,l,,ll,,,ll,,,l,ll,,i . Print your name, address, and ZIP Code in this box o DEYELOPM ENr SERY225 FIFTH STRE EI: $ L-.-- SPR'NGFI ELD, oR 97477 '/I:l 0 t