HomeMy WebLinkAboutPermit Correspondence 1980-10-09,UBLIC WORKS CIltrY OIF- SPF,IIiIGFIEIJD SPRINGFIELD. OREGON 97477 October 9, 1980 346 MAIN STREET 726-3753 CERTIFIED LETTER Ms. Lo11y Morris, Loan Officer c/o Department of Veterans' Affairs Farm and lome Loans 1500 Valley River Drive Suite 1.00 Eugehe, Oregon g74OO RE: Inspection Results of Plurnbing system at 1028 Mi11 Street Dear I{s. Ivlorris : On September 29, 1980, City of Springfield Plumbing Inspector, Roy Bordeaux, perfo^rmed a courtesy plunbing inspectio_n dt 1028 [{i11 Street, Springfield, br"gon as required ty-the Department of Veterans' Affairs. Most of the fol- loring items occur as a result of current remodeling on the structure. The followi-ng deficiencies were noted during this inspection: 1) The water heater has been enclosed by partition wal1s with no access pro- vided. The access is to be a ninimum of 24 inches wide and of a suffi- cient size to be able to remove the water heater per applicable codes (1g76 oregon State Plumbing speciality code, section 1311). 2) The water heater does not have a drain pipe. In order to comply with applicable codes the drain pipe needs to be- 3/4 inch in size and con- tinuous fron the pressure refi-ef valve to the outside (1'976 Oregon State Plunbing Speciality Code, Section 605) ' S) The automatic washing machine has been relocated so that the plumbing con- nections for the hot and cold water connection and the stand pipe drain are made by extended hoses running through an intervening wal1' This causes the plumbing connections to be unaccessible in the laundry (1976 Oregon State Plumbing Speciality Code, Section 604) ' 4) The vent connection pipe for the clothes dryer is laid across the floor of the laundry room and terminates at the inside of a window. This vent needs to be installed per the manufactures instructions and all applicable require- ments of the 1S7^S 6regon State Mechanical Speciality Code and Fire and Life Safety Code. 5) A portion of the kitchen wall is open around a shampoo bow1. This opening- n"ud, patched in an approved *urrrr", in order to comply with applicable codes (7g76 oregon state Plumbing Speciality code, section 309(a)). trls. Lolly l'lorris Courtesy Plumbing InsPection 1028 l'Iil1 Street october 7, 1980 Page 2. b)The kitchen sink leaks around the riru because of a bad seal. This seal will need to be replaced in order to meet the requirements of the 1976 Oregon State Plumbing Speciality Code, Section 309(1), and the 1973 Uniform Housing Code, as adopted by the City of Springfield, Section 504(9). If you have any questions concerning this matter please contact the City of Spring- field Building Division at 726-3753. Sincerely, Tom Sheirbon Permit Coordinator cc Ronald B. Clark, Superintendent of Building Richard James Falls, Owner 1028 Mi11 Street Springfield, 0regon 97477 {a rs/ Ij 1001. .1a