HomeMy WebLinkAboutPermit Building 1999-08-13SPFINGFIELD
AfiENTlOi'l:Oregon law reqtuires You to
ANY
follow ru tes adoPted bY the Oregon UtilitY
Notifi cation Center . Those rules are set lorthprtrrtNTrAL pERMrr AppLrcATroN
in OAR 952-001'001 0 through oAFl952'00 CITY OF SPRINGFIELD
0090 You maY obtain coPies of the rules bY comruNrry sERvrcEs DrvrsroN
calling the cente r. (Note: the telePhone BUILDING SAFETY
numberfg5 UtilitY Notification
, oR 97471
THIS PERMIT SHALL EXPIHE IFTHE WORK
AUTHORIZED UNDER THIS PEHMIT IS NOT
COMMENCED OR IS ABANDONED FOR
180 DAY PERIOD.
ilob Number:
office:
Inspection Line:
a
Page 1
990 I 95
726 -37 59
726 -37 69
Location of Proposed Work: 383L LONG RIDGE DR
Assessors Map #: 18020613
Lot: L2 Block:
Tax Lot #:
Subdivision:
09900
KEARNEY ACRES
OF SPilNGFIELT',CITY
Owner: HAYDEN HOMES
Address: 3258 PINYON STREET
Describe Work: S.F. RESIDENCE
Phone #: 744-6956
City/State/Ztp: SPRINGFIELD, OREGON 97478
NEW
ContracEor
ConsE.
ContracEor #Expires
o7/2e/ee
o7/02/oo
oe /27 / oo
o6/L0/oo
Phone
7 44- 6966
47 9 -2905
593-9353
36'7 -8250
Generaf:
Plumbing:
Mechanical
Electrlcal
HAYDEN OO922O8
2522 SW GLACIER PL #110 REDMOND OR
HAREBEINTNER OO8B2O1
6150 E STREET, SPRINGFIELD, OREGON
EFFICIENT HEATI OIL76B7
21,9001" E PERKINS RD KENNEWICK WA 99
ELITE ELECTRIC 0099758
38289 COURTNEY CREEK DR BROWNSVILLE
QUAD AREA: 3RSC
# OF UNITS: 1
CONSTR. TYPE: VN
SECONDARY HEAT: HP
INSUL PATH: SGC
-- OFFICE USE --
LAND USE: 1111
ZONING CODE: LDR
# OF BDRMS: 4
WATER HEATER: G
SQ FOOTAGE: 2396
# OF BLDGS: 1
OCCY GROUP: R3
HEAT SOURCE: FG
RANGE: E
To request an inspection, cafl the 24 hour recording aL 726-3769.
A11 inspections requested before 7:OO a.m. will be made the same working day,
inspections requested after 7:00 a.m. wi-11 be made the following work day.
--- REQUIRED INSPECTIONS ---
SITE - To be made after excavation but prior to setting forms.
FOOTING - After trenches are excavaLed.
FOITNDATION - After forms are erected but prior to concrete placement.
IINDERFLOOR PLUIIBING - Prior to insufation or decking.
ITNDERFLOOR MECHANICAL - Prior to insul-ation or decking.
POST AI.ID BEAI{ - Prior to f loor insul-ation or decking.
INSULATION - Floor; prior to decking Wa11/Ceiling; Prior to cover
WATER LINE - Prior to filling trench.
SA!{ITARY SEWER tINE - Prior to filling trench.
STORM SEWER IJINE - Prior to filling trench.
ROUGH PLITMBING - Prior to cover.
ROUGH MECIIANICAL - Prior to cover.
ROUGH ELECTRICAL - Prior to cover.
ELECTRICAL SERVICE - MusE be approved to obtain permanent power.
SHEAR WALL NAILING - Before covering sheathing with finish materials.
FRAMING - Prior to cover.
INSULATION - Floor; prior to decking Wall/Ceiling; Prior to cover
DRYWALL - Prior to taping.
CURBCUT - After forms are erected but prior to placement of concrete.
SIDEWALK - After excavation is complete, forms and sub-base material
in p1ace.
SPFINGFIELD
Job Number: 990895
CfiT OF SPruNGFIELD,
Page 2
FrNAL PLITMBING - When all plumbing work is complete.
FINAL MECHANICAL - When all mechanical work is complete.
FINAL ELECTRICAL - When aII efectrical work is complete.
FINAL BUILDING - When all required j-nspections have been approved and
the buifding is complete.
Lot Faces: W
Setbk From NPL: 29
House
Garage
Lot Sq. Ft.: 5025
Solar Approved: Y
Total HeighL: 24
Lot Type: INTERIOR
N
l4
),4
Setbacks
SW
15 37
28 18
E
10
38
Item
Main
Garage
Total- Value
Building Permit Fee
Surcharge/admin
TOTAI, FEE
BUILDING PERMIT
Square Feet x
20l.6
380
$/Square Feet
59 .64
18.34
(A)
Value
140,3 94.00
5 ,959 . OO
147,363.0O
541.00
43.28
584.28
PLI'MBING PERMIT
Item
Residential Bath(s)
Plumbing Permit
Surcharge/admin
TOTAL CHARGE
3
Fee
L92 .50
L92 .50
15 .44
207.91(c)
Furnace
Exhaust Hood
Vent Fan
Dryer Vent
HEAT PUMP
Mechanical Permit
Issuance
Surcharge/admin
TOTAI, PERMIT
MECHANICAL PERMIT
3
6.00
4.50
9.00
3.00
6.00
(D)
28.50
10.00
) )o
40.79
MISCELLA}iIEOUS PERMITS
Surcharge/admin
Sidewalk
Curb Cut
WILLA]VIALANE SDC
ELECTRICAL PERM]T
PLAN REVIEW FEE
SYSTEM DEVEL CHARGES
TOTAL MISCELLATiIEOUS PERMITS
0.00
60.00
50.00
1, 000 . oo
1,40 .40
80.00
2 , 452 .53
3 ,802 .93(E)
4 , 635 .9L(Excluding Electrical)
unless otherwise noted
TOTAL A.MOI'NT DUE - - -
(A, B, C, D, and E combined)
!sPR!I{GFIELD
Job Number: 990895
CITY OF SPilNGFIELD,a
Page 3
-.- BUII,DING VALUE, PLAIiI CHECK A}iID BUILDING PERMIT ---
This permit is granted on the express condition thaL the said construction
shal-l-, in all respects, conform to Lhe Ordinance adopted by the ClEy of
Springfield, including the DevelopmenL Code, regulating the construction and
use of buildings, and may be suspended or revoked at any time upon violation
of any provisions of said ordinances.
Received By:
Pl-ans Reviewed By: AL WARD
Building Site Reviewed By: LISA HOPPER
Date:08/02/99
--- ADDITIONAL COMMENTS ---
A & T DEFAULT AMOTINT USED FOR CITY CREDIT PURPOSES
ONLY. LOT NOT LISTED IN A & T AS OF 7/20/99
DRIVEWAY REQU]RED TO BE PAVED
2 STREET TREES REQUIRED
By signaEure, I statse and agree, Lhat I have carefully examined
the completed application and do hereby certify that all information hereon
is true and correct, and I further certify that any and al-I work performed
sha11 be done in accordance with the Ordinances of the City of Springfield,
and the Laws of the State of Oregon pertaining to the work described herein,
and that NO OCCUPANCY will be made of any structure without permission of the
Community Services Division, Building Safety. I further certify that only
conLractors and employees who are in compliance wiLh ORS 701.055 will be
used on thls project.
f further agree Lo ensure that all required inspections are requested at the
proper time, that each address is readable from the street, that the permit
card is located at the front of the property, and the approved set of plans
will remain on the site at all times during construction.
44-,/r=/n
Signature Date
--- VALID.A,TION ---
Receipt Number:
Date Paid:
Amount Received
Received By
%B.9{
JOURNAL C
ATTACHMENT A
CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE
WORKSHEET
NAME OR COMPANY il AY DE,')Uo*,6
LOCATION 3A 3l Lor'tc' Rr ob6 Dra-
YoB No. q4 o Aq{
DEVELOPMENT TYPE
BUILDING SVF,:
4rfL
ffi-
MPERViOUS SQ. FT. 4p_se_X $0.232 pER Se. FT
2. SAMTARY SEWER-CITY
LOT SIZE SQ. Ft.
$ +12, 3.{
$ z,24.<. zl
$ lt7, zc
Roof
D /U/
Z
\b
zovtt
\14waB
: 368? ,3a6
+ 3ao
L
1. STORM DRAINAGE
NO. OF PFU'S X$48.27 PER PFU $ ,'/o zt
(See Reverse Side)
3. TRANSPORTATION
NO OF TINITS X TRIP RATE X COST PER PM PEAK HOIJR TRIP
x tt0( x$486.73PERTRIP S 41a,e6,
X $486.73 PER TRIP S
4. SANITARY SEWER-MWMC
A. REIMBI.IRSEMENT COST :
NO. OF FEU'S I X Z4?,7L PER FEU S Z4Z,7e
B. IMPROVEMENT COST:
NO. OF FEU'S I X Z7 , O{PER FEU $ zz,o{
MWMC CREDIT IF APPLICABLE (SEE REVERSE)
MWMC ADMiMSTRATTVE FEE
<$ -L,7d >
s 10.00
TOTAL-MWMC SDC s z7z, tl
SUBToTAL (ADD ITEMS t,2,3 & 4)
5. ADMINISTRATTVE FEES:
BASE CHARGE (suBToTAL ABOVE) X .0s
SDC Coordinator
ATTACH'A.WPD
$ zlaz,S3
X
---r-
-Lo -??
TOTAL SDC
l
FIXTURE UNIT CALCULATION TABLE! NumberorNerv' turesXUnit Equivalent : Fixrure [Jnits(NOTE: For remodels, calculate only tl lI additional fixrures)
NUMBER OF
NEW FIXTURES
TOTAL FIXTURE LTNITS
LTNIT
EQUIVALENT
FIXTURE
TINITSFIXTURE TYPE
Drinking Fountain..
'-z>
Floor Drain..
2
1
2
J
6
2
6
6
I
J
2
I
2
2
I
6
4
7
+
za
Interceptors For Grease/Oil/Solids/Etc..
Interceptors For Sand./Auto Wash/Etc...
Laundry Tub/Clotheswasher/tr4op Sink.
Clotheswasher - 3 Or More............
Mobile Home Paik Trap (1 Per Trailer)..
Receptor For RefrigeratorAVater Station/Etc...........
Receptor For Commercial SinkDishwasher/Etc_.....
Shorver, Single Stall.
Shower, Gang............
S ink: Bar, Commercial, Resiclential Kitchen............
Urinal, Stall/Wall.....
Wash Basin/Lavatory, Single...........
Toilet, Public Installation..
Toilet, Private.......-..
Miscellaneous:
t
/Head
CREDIT CALCULA TION TABLE: Based on assessed value.If improvements occurred after annexation date in table, calculatecredits
Credit for Parcel or Land Only If Applicable X $ r(, p<,:a
(Rate X Assessed Value)
Improvement (if after annexation date) X $ _
(Rate X Assessed Value)
Residential...
Commerical.
Industrial.....
Governmental............... -,.....
Z,1D
CREDIT TOTAL :S 2,7 D
RUNOFF COEFFICIENTS FOR STORM DRAINAGE
(For Estimating purposes Only)
0.4
0.9
0.5
0.5
Year
Annexed
Rate per $ 1,000
Assessed Vaiue
Year
Annexed
Rate per S 1,000
Assessed Value
1979 or before
1980
1981
1982
1 983
1984
l 985
r986
1987
I 988
$4.47
4.38
4.32
4.20
4.03
3.88
3.68
3.38
3.03
2.62
r 989
r 990
1991
t992
r 993
r994
l 995
1996
2.18
1.7 5
1.35
t.t7
r.03
0.86
0.71
0.57
0.39
0.18
I
FIXUNM.WPD IMPERVIOUS AREA: TorAL Lor sIzE x RUNOFF COEFFICIENT
Z_
z-
3
lz-3
225 FIFTB STREET
SPRINGFTELD, oREGON 97477
INSPECf,ION REQLTEST. 726-3769
OFPICE: 726-3759
1 ON OF ONt#
6
Ffsktfr#i3o"x3il"
Tm FEPnnltqfiLtosxPtne
AUTHORIZED UNDER THIS P
FlINGFlELD
BLECTRICAL PERHIT
Ci ty Job Nurnber
COHPLETE FEE SCEEDIILE BELOV
Nev Residential-Single or
MuIti-FamiIy per dwelling unit.
Service Included:Items Cost
1000 sq.ft. or less t 5 B5.OO
Each additional 500
JOB DESCRIPTION
Permits are non-transf
if vork is not started
of issuance or if work
180 days.
3
A
Sumtf
2 . coNrRAcron rNsrALI ttfifiUEfudb ol
! : IBAN
EoNED#0B i i: . i :, :"ii il i "., ", "Electrical contractor {I,tlPrBAYEHfl[h. or Relocation:
Address lOl k vqL @-
Ci ty Loc€<rnf-- Phone (e88- 5v-t
Supervi-<or Li cense Number
sq. ft or portion jthereof
Each Hanuf'd Home. or
-tF 1{Ffl$H( 'Dwe11ing
enurfrts\ir,ff or Feeder
200 amps"or less
201 amps to 400 amps
-0ver 40L to 600 amps
0ver 600 amps or 1000 voTE
200 amps or Less lS 50;00
201 amps to 400 amps
-
S 60.00
401 amps to 600 amps
--
5100.00
601 amps to 1000 amps- 5130.00
over 1000 amps/volts
-
5300.00
Reconnect Only S 40.00
s 1s.00 N
s 40.00
ee i'8, a566=
Expiration Date
Constr Contr. N
Expiration Date
3SQ-.C Temporary Services or Feeders
Installation, Alteration or Relocationumber
)o- l-s
$
sss
40.00
55.00
80.00of Supervis
0vners Name
Address ?>CA 9.'.*'Y
3ll '^$A'rt/)
D. Branch Circui ts
Nev, Alteration or Extension Per Panel
trrc1'an
Ci ty
The ins ta
property
for sa1e,
OITNER INSTALI.NTION
Phone -6?dG One Circuit S 35.00
Each Addi tional
Circuit or vith Service
or Feeder Permit $ 2-OO
n requires you to E. Miscellaneous (Service/feeder not includedlity-Each installation
Pump or irrigation _Sign/0utIine Lighting_
Limited Energy/Res
Limi ted Energy/Comm
forth
0 through OAR 952-001-
SUBTOTAL OF ABOVE
52 State Surcharge
32 Admini.s trat ive Fee
TOTAL
,vne r s "
gfl
B3i[[,t1 [?":?"iJ t.il3,ffi :i:fr'r*: "
number for the Oregon Utility Notification
s 40.00
s 40.00
s 20.00
s 36.00
DATE:
RECEIVED B
5
(,
a
Willamalane ,\)OPark & Recreation District Job. No.
SYSTEM DEVELOPMENT CHARGE
WORKSHEET
PHONE:NAME:
ADDRESS:
LOCATION OF PROPOSED ING SITE:
Street Address:
Plat Name:
ype are on the
A Single-Family Detached
t Single Family home
NO. OF UNITS
srArE: s&71p, Q14J8
a)t
1.
Tax Numb
appropriate dwelling(s). SDC calculations and dwelling t
Manufactured home not in a park
X $1,000 per unit = $\DCO.()
B. Single-Family Attaehed
NO. OF UNITS X $924 per unit
C. Multi-Family Apartment
NO. OF UNITS X $692 per unit
D. Manufactured Home Park
NO. OF UNITS
WILLAMALANE SDC
2. SDC CREDtt (it applicable) SDC+ayer must tunrish proof of
Willamalane Credit approval. See SDC Credit Wotlcsheel
3. TOTAL WILLAMALANE NET SDC ASSESSED
(if SDC reduced for Credit)
Development Se
$
$
$X $699 per unit
@$
$
$
6
l_6_,
City of Springfield
e ment Date
oc)