Builders Statement tnsulsafe'sP Ef;,*"\\ts:fi3
Fiber Glass Blowing lnsulation
Homeowner Name / Jobsite Name
s
Home Address
/ Contractor (sign)Company Name Date
Builder (sign)Company Name Date
lnspected By (sign if required)
OPEN ATTIC APPLICATION
Date
H-VALUE
MINIMUM
BAGS PER 1OOO SO. FT.
MAXIMUM NET SO. FI.
PER BAG COVEBAGE
MINIMUM WEIGHT-
POUNDS PER SO. FT.
MINIMUM
INSTALLED THICKNESS
MINIMUM
SETTLED THICKNESS
To obtain a
thermal resistance
(R) ot:
Bags per
1000 sq. ft.
ol net area:
Contents of bag
shall not cover
more than: (sq. ft.)
Weight per sq. ft. of
installed insulation shall
not be less than: (lbs.)
lnstalled insulation
shall not be less than:
(in.)
Minimum settled insulation
shall not be less than:
(in.)
60 3'1 .4 31 .9 0.972 22.00 22.00
49 25.2 39.7 0.780 18.50 18.50
44 22.4 44.6 0.695 16.75 16.75
38 19.1 52.5 0.591 14.50 14.50
30
26
22
14.9
12.8
10.8
67.1
77.9
92.9
0.462
0.398
0.334
0.289
1'1 .75
10.25
8.75
7.75
o7(
7.75
19
13
11
OQ
6.2
5.3
107.4
161 .7
190.5
0.192
U,IOJ 4.50
5.25
4.50
B.VALUE THICKNESS NET AREA (SO. FT.)INSULSAFE SP 7)BAGS USED BATTS/HOLLS (/)
CEILINGS 3B lq,5 t
.]qo_35
WALLS
FLOOBS
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
. ln accordance with the chart above, you must install the minimum number of bags per 1,000 sq' ft' of net area for each
R-Value listed.
. The maximum net coverage must not exceed that specified for each R-Value'
. The insulation must be installed at or above the specified installed thickness for each R-Value'
. Failure to install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in
reduced R'Value.
. This product should not be mixed with other blown insulations or the thermal claims will become invalid'
DANGER: RECESSED LIGHT FIXTUHES_TO PREVENT OVERHEATING' DO NOT INSULATE-ON TOP OR WITHIN 3' OF
SUCHDEVICES.THISWARNINGDoESNoTAPPLYToTYPEIcLIGHTFIXTURESoRToFLUoRESCENT
FIXTURES WITH THERMALLY PROTECTED BALLASTS'
@2007 CertainTeed Corporation
A saint-Gobain ComPanY
go-24-2g1 Builders Statement 2/07
11.75
10.25
Manufacturer lnsulation Fact Sheet
This is CertainTeed Corporation InSUlSafe@ SP
CertairileedEl
Fiber Glass Blowing lnsulation
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
COVERAGE CHART-OPEN ATTIC APPLICATION
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in a horizontal open blow applicalion.
R-Values are determined in accordance with ASTM c6B7 and C518. complies with ASTM C764 asType 1 pneumaticApplication.
lnitial installed thickness, testing per ASTM c13.74 using Unisul VoluMatic lll; 4th gear; 15-inch gate opening; 150 fr. x4-inch diameter internally corrlrgated blowing hose.
COVERAGE CHART-CLOSED CAVITY RETROFIT (WAI-LS, FIOORS, CEITINCS) APPTICATIONSThe following thermal performances are achieved at the thicknesses, we.ights and coverages specified when insulationis installed with pneumatic equipment in sidewalls. Based on ,-JLrig, density of 1.6 pcf/25.6 Kg/m3.
R-VALUE
BEQUIRED OB MINIMUM
BAGS PER 1OOO SO. FT.
MAXIMUM NET SO. FT-
PEF BAG COVERAGE
MINIMUM WEIGHT-
POUNDS PER SQ. FT.
INSTALLED
THICKNESSTo obtain a
thermal resistance
of:
29
16
Bags per
1000 sq. ft.
of net area:
31.2
-t7.2
Contents of bao
shall not cover-
more than: (sq. ft.)
Weight per sq. ft. of
installed insulation shalt
not be less than: (lbs.)
lnstalled insulation
shall not be less than:
-
(in.)
15
14
1 6.1
15.1
62.0
66.4
0.533
0.500
0.467
4.00
3.75
3.50
R-VALUE
MINIMUM
BAGS PER lOOO SO. FT.
MAXIMUM NET SO. FT,
PER BAG COVEBAGE
MINIMUM WEIGHT-
POUNDS PER SO. FT.
MINIMUM
INSTALLED THICKNESS
MINIMUM
SETTLED THICKNESS
To obtain a
thermal resistance
(R) of:
Bags per
1 000 sq. ft.
of net area:
Contents of bao
shall not cover-
more than: (sq. ft.)
Weight per sq. ft. ol
installed insulation shall
not be less than: (lbs.)
lnstalled insulation
shall not be less lhan:
Minimum settled insulation
shall not be less than:
60 31.4 31.9 0.972 22.00 22.0049
44
38
JU
26
25.2
22.4
19.1
14.9
12.8
107
44.6
52.5
67.1
77.9
0.780
0.695
0.591
0.462
0.398
18.50
16.75
'14.50
'11.75
10.25
'18.50
'16.75
14.50
11.75
10.2522
19
'13
11
10.8
9.3
6.2
5.3
92.9
107.4
'161 .7
0.334
0.289
8.75
7.75
5.25
4.50
8.75
7.75
5.25
4.50
What you should know about R_Values.
The chart shows the R-Value of this insulatron. R means resistance to heat flow. The higher theR-value, the greater the insulating po*", compare in.l,r"jtn R-values before you buy.There are other factors to consider. The amount of insulation,you need depends mainly on theclimate you live in. Also, your fuel.uring. from insula-td'*irr o"b"n;G;;; ctimate, the typeand size of your house, the amount oi inisutatior. ,r1i;;Y- ir'yow house, and your fuel use patternsand family size' lf you buy too much iniulation, it wl-r clsi you more than what you,ll save on fuel.To get the marked R-value, it is essential that this insulation oe installed properly.
@007 CertainTeed Corporation A Saint-Gobain Company 30-24-298 Manufacturer Fact lnsulation Sheet 2/07
190.5
0.1 92
0.163