HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-09-06CertainTeedE{ Builders Statement tnsulsafe'sP Ef;,*"\\ts:fi3 Fiber Glass Blowing lnsulation Homeowner Name / Jobsite Name s Home Address / Contractor (sign)Company Name Date Builder (sign)Company Name Date lnspected By (sign if required) OPEN ATTIC APPLICATION Date H-VALUE MINIMUM BAGS PER 1OOO SO. FT. MAXIMUM NET SO. FI. PER BAG COVEBAGE MINIMUM WEIGHT- POUNDS PER SO. FT. MINIMUM INSTALLED THICKNESS MINIMUM SETTLED THICKNESS To obtain a thermal resistance (R) ot: Bags per 1000 sq. ft. ol net area: Contents of bag shall not cover more than: (sq. ft.) Weight per sq. ft. of installed insulation shall not be less than: (lbs.) lnstalled insulation shall not be less than: (in.) Minimum settled insulation shall not be less than: (in.) 60 3'1 .4 31 .9 0.972 22.00 22.00 49 25.2 39.7 0.780 18.50 18.50 44 22.4 44.6 0.695 16.75 16.75 38 19.1 52.5 0.591 14.50 14.50 30 26 22 14.9 12.8 10.8 67.1 77.9 92.9 0.462 0.398 0.334 0.289 1'1 .75 10.25 8.75 7.75 o7( 7.75 19 13 11 OQ 6.2 5.3 107.4 161 .7 190.5 0.192 U,IOJ 4.50 5.25 4.50 B.VALUE THICKNESS NET AREA (SO. FT.)INSULSAFE SP 7)BAGS USED BATTS/HOLLS (/) CEILINGS 3B lq,5 t .]qo_35 WALLS FLOOBS THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION . ln accordance with the chart above, you must install the minimum number of bags per 1,000 sq' ft' of net area for each R-Value listed. . The maximum net coverage must not exceed that specified for each R-Value' . The insulation must be installed at or above the specified installed thickness for each R-Value' . Failure to install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in reduced R'Value. . This product should not be mixed with other blown insulations or the thermal claims will become invalid' DANGER: RECESSED LIGHT FIXTUHES_TO PREVENT OVERHEATING' DO NOT INSULATE-ON TOP OR WITHIN 3' OF SUCHDEVICES.THISWARNINGDoESNoTAPPLYToTYPEIcLIGHTFIXTURESoRToFLUoRESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS' @2007 CertainTeed Corporation A saint-Gobain ComPanY go-24-2g1 Builders Statement 2/07 11.75 10.25 Manufacturer lnsulation Fact Sheet This is CertainTeed Corporation InSUlSafe@ SP CertairileedEl Fiber Glass Blowing lnsulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 COVERAGE CHART-OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow applicalion. R-Values are determined in accordance with ASTM c6B7 and C518. complies with ASTM C764 asType 1 pneumaticApplication. lnitial installed thickness, testing per ASTM c13.74 using Unisul VoluMatic lll; 4th gear; 15-inch gate opening; 150 fr. x4-inch diameter internally corrlrgated blowing hose. COVERAGE CHART-CLOSED CAVITY RETROFIT (WAI-LS, FIOORS, CEITINCS) APPTICATIONSThe following thermal performances are achieved at the thicknesses, we.ights and coverages specified when insulationis installed with pneumatic equipment in sidewalls. Based on ,-JLrig, density of 1.6 pcf/25.6 Kg/m3. R-VALUE BEQUIRED OB MINIMUM BAGS PER 1OOO SO. FT. MAXIMUM NET SO. FT- PEF BAG COVERAGE MINIMUM WEIGHT- POUNDS PER SQ. FT. INSTALLED THICKNESSTo obtain a thermal resistance of: 29 16 Bags per 1000 sq. ft. of net area: 31.2 -t7.2 Contents of bao shall not cover- more than: (sq. ft.) Weight per sq. ft. of installed insulation shalt not be less than: (lbs.) lnstalled insulation shall not be less than: - (in.) 15 14 1 6.1 15.1 62.0 66.4 0.533 0.500 0.467 4.00 3.75 3.50 R-VALUE MINIMUM BAGS PER lOOO SO. FT. MAXIMUM NET SO. FT, PER BAG COVEBAGE MINIMUM WEIGHT- POUNDS PER SO. FT. MINIMUM INSTALLED THICKNESS MINIMUM SETTLED THICKNESS To obtain a thermal resistance (R) of: Bags per 1 000 sq. ft. of net area: Contents of bao shall not cover- more than: (sq. ft.) Weight per sq. ft. ol installed insulation shall not be less than: (lbs.) lnstalled insulation shall not be less lhan: Minimum settled insulation shall not be less than: 60 31.4 31.9 0.972 22.00 22.0049 44 38 JU 26 25.2 22.4 19.1 14.9 12.8 107 44.6 52.5 67.1 77.9 0.780 0.695 0.591 0.462 0.398 18.50 16.75 '14.50 '11.75 10.25 '18.50 '16.75 14.50 11.75 10.2522 19 '13 11 10.8 9.3 6.2 5.3 92.9 107.4 '161 .7 0.334 0.289 8.75 7.75 5.25 4.50 8.75 7.75 5.25 4.50 What you should know about R_Values. The chart shows the R-Value of this insulatron. R means resistance to heat flow. The higher theR-value, the greater the insulating po*", compare in.l,r"jtn R-values before you buy.There are other factors to consider. The amount of insulation,you need depends mainly on theclimate you live in. Also, your fuel.uring. from insula-td'*irr o"b"n;G;;; ctimate, the typeand size of your house, the amount oi inisutatior. ,r1i;;Y- ir'yow house, and your fuel use patternsand family size' lf you buy too much iniulation, it wl-r clsi you more than what you,ll save on fuel.To get the marked R-value, it is essential that this insulation oe installed properly. @007 CertainTeed Corporation A Saint-Gobain Company 30-24-298 Manufacturer Fact lnsulation Sheet 2/07 190.5 0.1 92 0.163