Loading...
HomeMy WebLinkAboutPermit Building 2019-08-28Building Permit Residential Structural Permit Number: 811-19-001972-STR IVR Number: 811048100229 City of Springfield Development and Public Works 225 Fifth Street Springfield, OR 97477 541-726-3753 Web Address: www.springfield-or.gov Email Address: permitcenter@springfield-or.gov Permit Issued: August 28, 2019 Project: 263 18th St Category of Construction: Single Family Dwelling Submitted Job Value: $56,900.00 Description of Work: Voluntary repair to existing foundation Type of Work: Repair Worksite Address 263 18TH ST Springfield, OR 97477 Parcel 1703362401300 Owner: Address: VANDYKE NOEL D & CAROL M 36243 ENTERPRISE RD CRESWELL, OR 97426 Business Name KEM LLC KEM LLC Ucense (PB) Plumbing Contractor CCB Ucense Number PB1269 146906 Phone 541-688-7177 541-688-7177 Inspection 1999 Final Building 1110 Footing Inspection Group Struct Res Struct Res Inspection Status Pending Pending Various inspections are minimally required on each project and often dependent on the scope of work. Contact the issuing jurisdiction indicated on the permit to determine required inspections for this project. Schedule or track inspections at www.buildingpermits.oregon.gov Call or text the word "schedule" to 1-888-299-2821 use IVR number: 811048100229 Schedule using the Oregon ePermitting Inspection App, search "epermitting" in the app store Permits expire If work Is not started within 180 Days of Issuance or If work Is suspended for 180 Days or longer depending on the Issuing agency's policy. All provisions of laws and ordinances governing this type of work wlll be complied with whether specified herein or not. Granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth In OAR 952-001-0010 through OAR 952-001-0090. You may obtain copies of the rules by calllng the Center at (503) 232-1987. All persons or entitles performing work under this permit are required to be licensed unless exempted by ORS 701,010 (Structural/Mechanlcal), ORS 479,540 (Electrical), and ORS 693.010-020 (Plumbing), Printed on: 8/28/19 Page 1 of 2 C:\myReports/reports//production/01 STANOARD F r o m : 0 B /2 8 /2 0 1 9 1 4 :0 0 #0 0 8 P .0 0 1 /0 0 3 Structural Permit Application CITY OF Sl'Rl'.\Cil ll LD. ORFCiO:-.' 225 Fifth Street• Springfield, OR 97477 • PH(S41)726-3753 • FAX(S41)726-3689 DEPARTMENT USE ONLY Permit no.: Date: This permit is issued under OAR 918-460-0030. Permits expire lfwork is not started within 180 days ofi,nance or if work is suspended for 180 days. ·. LOCAL GOVERNMENT APPROVAL This project has final land-use approval. Signature: Date: This project has DEQ approval. Sigtt_ature: I Date: Zoning approval verified: 0 Yes O No Property is within flood plain: D Yes D No 0 R esidential I O Governm ent R eference: Taxlot: . :PRQPERTY00W NER . '..: .•.. ·. Address: C ity: State: ZIP: Phone: Fax: E-m ail: Building Sign here lication: 0 This install.W on is being m ade on residential or farm property owned by m e or a m em ber ofm y imm ediate fam ily, and is exem pt from licensing requirements under O R S 701.010. . . . . , \ ·• .·· , :_ .··• FEE s~i:tEi>vLe : ' . . . ' • .. ' ' '·. -_ ~- '. ·, ' ·- . 1.Va111ationinformtion : '- : ., .\; .'. ':' ·\\. ' · ; ' {a)Jobdescription:u_,1!~~~ .••.. ._. "•'"A:Y' ~p~"Llh~,J. f':. - I L, __ 1 Occupancy T I J Construction type: Square feet: Cost per square foot: Other inform ation: Type of Heat: EnereyPatb: O new O alteration D addition {b) Foundation-only permit? 0 Y es 0 N o Total valuation: 5"G), q oo s 2.iiuUci:1.i,r~ >/'·\~·,:· ': , ; : ·, : · , ,_, {a) Permit fee (use valuation table): s {b) Investigative fee {equal to [2a]): $ (c) Reinspection (S per hour): $ {number of hours x fee per hour) {d) Enter 12% surcharge {.12 x [2a+2b+2c]): $ (e) Subtotal of fees above (la througb 2d): $ 3. ,~ •• :~li,wteeii \' , -, > ; , ',_ -. ... ' : -~ ·• . . ·:··.·.,_ :, . (a) Plan review (65¾ x perm it fee [2a]): $ {b) Fire and life safety {65% x permit fee (2a]): $ (c) Subtotal of fees above (3a and 3b): $ 4. Mis~euaneou'srees •· · • :' . ,··: ... \ ·:. ::.'·, <.·,,.>:.· (a} Seismic fee, 1% (.01 x permit fee [2a]): s {b) Tech fee, 5% {.OS x perm it fee(2a]+PR fee (3c]) $ JOT AL fees and surcharges (2e+3c+4a+b): sR1d- ,1-'-i Nam e CCB U cense# Phone Electrical Plum bing M echaaical Last edited 5-5-2019 BJones From: 08/28/2019 14:06 #009 P.002/003 AR E A T O B E RE M O V E D C ARPORT G R A D E B ACK F ILL D O WN A N O A WA Y F R O M F O U N D AT IO N N EW FO U N D A T IO N ' -¾" -~" HI 1 A O" -½" +½" -1 0 1/S K-2 m -1· -1½" ·. P O N D IN G WATE R (TYP ) -2½" E N T R Y C ) PLANNQJES FLO O R FR A M IN G W ILL B E P RO V ID E D AT T IM E O F LIF T . FOUNDATION REPLACEM ENT PLAN LEGEND -¾" - - - - FLO O R ELE V AT IO N S TAK E N BY RAM JACK O N 6/26/20 19 EB NORTH N O E L V A N DYKE 26318THST SPRINGFIELD, OR SHEET: SK-1 SCALE: 3132·-1·-o DATE: 08/22!.2019 From: 08/28/2019 14:07 #009 P.003/003 [ EXPIR ATION D ATE. 6/30.IU I EXISTING EXTERIOR W OOO FRAMED WALL MIN. 1x ·BELLY BAND· To MATCH EXISTING SIDING DEPTH u( (06. "~Cs tft( ~ u ·-o,c.... NEW FOUNDATION NOTE: - THE STRUCTURE MUST REMAIN SHORED UNTIL CONCRETE IS CURED. CONCRETE MIN. SIDE COVER =2•, MIN. TOP/BOTTOM COVER s3• GEOTECH BY OTHERS EXISTING FLOOR JOISTS BEAR ON FOUNDATION WALL J5•0 x 10• J-BOL TS @ 7'r O.C. AND 1'r FROM CORNERS WI BP WASHERS -,___ #4 VERTICAL @-48• O.C. W/4•HOOK ,..c ~ I I ~~ .•• >'~.,....:;~---- VAPOR BARRIER MIN. 3•0 SCHEDULE 40 PERF DRAIN LINE IN CLEAN ROUND ROCK. 1 % TRENCH SLOPE TO RELIABLE OUTLET (2) CONTINUOUS #4 BOTTOM BARS 01 NEW FOUNDATION DETAIL FOR CMU ASSEMBLY: F'm 11 1500 PSI USE 8"x8"x16• SOLID GROUTED REBAR: ASTM GRADE 60 FOR CONCRETE STEM WALL: F'c = 3000 PSI. USE s• WIDE W? 15• WIDE FOOTING NOEL VAN DYKE 26318TH ST SPRINGFIELD, OR SHEET: SK-2 SCALE: 3132·-1·-o DATE: 08/22/2019