Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit Building 2019-06-13
SPRINGFIELD OREGON Web Address: www.springfield-or.gov Permit Issued: June 13, 2019 Building Permit Residential Manufactured Dwelling Permit Number: 811 -19 -000836 -MD IVR Number: 811063942362 City of Springfield Development and Public Works 225 Fifth Street Springfield, OR 97477 541-726-3753 Email Address: permitcenter@springfield-or.gov 1020 Zoning/Setbacks 5300 MH Setup 5240 Footing 6300 On-site Stormwater Facility 6303 Final On -Site Stormwater Facility 6301 On-site Stormwater Facility -Dig Out/Piping Struct Res TYPE OF WORK Mfd Dwelling Category of Construction: Manufactured Dwelling Type of Work: New Pending Submitted Job Value: $80,000.00 Pending Public Works Description of Work: New Manufactured Home Public Works Pending ]OB SITE INFORMATION Worksite Address Parcel Owner: ANDERSON JACK E 5550 A ST 1702334201300 Address: 915 SHERWOOD PL Springfield, OR 97478 EUGENE, OR 97401 LICENSED PROFESSIONAL INFORMATION Business Name License License Number Phone 3 A CONSTRUCTION LLC - Primary CCB 167959 971-218-3568 JESUS G ANDRADE (MDI) Manuf Dwelling Installer 1974MDI 971-218-3568 PENDING INSPECTIONS Inspection Inspection Group Inspection Status 5999 Final Manufactured Dwelling Mfd Dwelling Pending 1020 Zoning/Setbacks 5300 MH Setup 5240 Footing 6300 On-site Stormwater Facility 6303 Final On -Site Stormwater Facility 6301 On-site Stormwater Facility -Dig Out/Piping Struct Res Pending Mfd Dwelling Pending Mfd Dwelling Pending Public Works Pending Public Works Pending Public Works Pending 6302 On -Site Stormwater Facility -Soil and Public Works Pending Plantings SCHEDULING INSPECTIONS Various inspections are minimally required on each project and often dependent on the scope of work. Contact the issuing jurisdiction indicated on the permit to determine required inspections for this project. Schedule or track inspections at www.buildingpermits.oregon.gov Permits expire if work is not started within 180 Days of issuance or if work is suspended for 180 Days or longer depending on the issuing agency's policy. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. Granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain copies of the rules by calling the Center at (503) 232-1987. All persons or entities performing work under this permit are required to be licensed unless exempted by ORS 701.010 (Structural/ Mechanical), ORS 479.540 (Electrical), and ORS 693.010-020 (Plumbing). Printed on: 6/13/19 Page 1 of 2 C:\myReports/reports//production/01 STANDARD -0 N - N M > Y () n Ln O p 7 I, 01 0) N LO OL u 0O ^ v Cl) iL N w a v 'r rn 0 -p N N Ln C > C N Q1 n C N U C va E Ln Cl C O U a Y > v E a r c M O) O Oo _ 'cr O 'IT N O O v O a O O CD i '++ v Q 0 4 w Z rn � co O a N OO O O OD 6 4 6 n N r_: N a� r c M O) O Oo _ 'cr O 'IT N O O v O a O O CD O O O rn Nr co O O N OO O O OD 6 4 6 n N r_: N a� O_ C> O OD v= cm O O O rn L M LO C .a � O M LO M Q 0 "tv O'T 'T � 'T � IT 'gr IT 'Tv H 669 N IT K3 co aUi ER b4 Q N b9 M O O Ln 0 F C O Ln M O C9 O) O FO O O OC O V) N Lu. O 'a N M LL c .. 0 M N (7 O O p) O O Z O O O O O O d O O c O_ NN .O 45 N� C Z ;r IT M r c M O) O O _ 'cr O 'IT N O O co O a O O O O O O CD Nr co O O N OO O O N OD 6 4 6 n N r_: N 4 O_ C> O OD E cm O O O co L M LO O � O M LO M Q 0 "tv O'T 'T � 'T � IT 'gr IT 'Tv � 669 N IT K3 N aUi ER b4 O N b9 M b9 O O 696ck O O b9 O O C O O O 64 O O 64 O O O O O O O O O O O O 0 a O 09 O O O O O O O O O O O O O O O O O O O O W C ;r IT M M M M r d) Q (o co (o co Cl) �- Cl) Cl) i Cl) (O f- fl - � ci (Yi Z LL r C M O O : O _ � O Nr N O O co O 3 LO O O O O O OR lqr. OR O O N O O c .� OO OO It w U f- (V I -T m It OD E r Cl) co M V> Z _O � M O7 N (CO Hi D C4 V9, LO � (f} LO U 64 6% U U3 dGo (/I 0 64 U 0 o 0 m -7 j U _ (0 O O O LL ZZ (n 0 C 0 O_ >� O OOOOO c O O O O O O OO 7 co Op co 00 OO O 00 O OD 00 00 O 00 OD OO O OD 00 OD OO O 00 O O N OO N CN N O N O N n N CN N O N rl-O 0 O N C> O 0 0 O O E O 00 O O O O co O O O co O co O O (O O M O O co (O co Q 0 "tv O'T 'T � 'T � IT 'gr IT 'Tv Q v N IT v I N N N N N IT IT M 0 O O O O O O O O O O O O O O O C O O O O O O O O O O O O O O O O O O O O O O O O O O 09 O O O O O O O O O O O O O O O O O O O O O O O O C ;r IT M M M M r d) Q (o co (o co Cl) �- Cl) Cl) i Cl) (O f- fl - � ci (Yi E CL CL d ca rn y m U LL c .� U o c O m o •O) r' O c a)C 1° O) N L) y7 E `o D c o 2 U U (i LLL c c N O (/I 0 0 J U 0 o 0 m O j U _ (0 O O O ZZ (n 0 C 0 O_ >� O U>, O N O , H N N U O CI i i cm N a) o 'C C (`0 M UU 0 m 0 m U N 0 M N L •E 'E H Co c U C U C (o C U O U Co fD -O V ¢ a E c E c E c E m m c > `�° CA E E E E E E E o r- o U o 0 3 S o'o .0 o'o 'oo m 'oo Q U c (n in f a E m $ E a E a E w :? 0 0 0'i 0 0 0 0 0 d a c N O a) CL c c c c c c c c c c c c c 7 7 7 7 7 7 7 7 7 7 7 7 O O O O O O O O O O O O O E E E E E E E E E E E E E Q Q Q Q Q Q Q Q Q Q Q Q Q M O O O O N O O OD O O O O (O O O OR OR O O N OR OD OO IT (O I- N V O 't OO C N N r O (O O O �- O i Cl) � ci (Yi E CL O7 G r' O y7 N O O) O O O) O M O O O m O (M co ZZ C') co r m M (`0 M r m m .M- M r m c H Co (o (o (o (o (o (o to (o (o Co fD to d J ( 0 - q q q q @ @ -0 3 \ � \ \ k § ) / ± a to (D CD c c = o; -_ C { 0 / 2 2 - k a ' S+E /$ �o = r- > @ 6 ;a r- v CL (13 Cl CD on / \\ < § e a � o o z . ' Cn S& § k k k 0 k k � O 2 0 > m m m m; a _ c » CO @ 0 f 0to 0 E_ R # \ q $ �CD 0 _ \ ® _ w §,■ \ Cl) § \ m E { ® ` t_ \ u0 w 2/ C-nf 0 0 L # $ § CD ®S ECL CD § / \ ƒ ƒ I - J � / 0 \ £ A / f f © -n ® § § 7 m (D2 @ 2 _ © 0 ƒ 3 0 \ CDa f CD i © � CDQ _� 0 ' ■ ■ § 0 0 0 0 2 R CL 0CD W § - § Kj s (D k k k E 2 . § � � kML 0 0 0 0 � \ \ / ) 2 \ \ / \ / / / 0 0 0 0 \ k § \ \ / 0 -n 69 CD 4) V) 00 69q e 697 § m N f f / -4 2 \ d S G S t R S g \ fD o 0 3 < g 0£ r .. 2 2 E n a @p 2piq » /�kU-0 - f CA) e e� n �i\ 7 k $ E k$ q w§ 0§�/^ w w 0 7 N f R 9 9 o o W w / k b CA w o o # o c c \ 4 a, m 0 0 0 o o q j-& rL CITY OF ' ' 1OREGON SPRINGFIELD DEPARTMENT USE ONLY Permit no.: 225 Fifth Street ♦ SDrinefield. OR 97477 ♦ PH(5411726-3753 ♦ FAX(541)726-3689 Manufactured Dwelling/Recreational-Park Trailer Date: �- l 8 Placement Permit Application This permit is issued under OARS 918-500-0105 and 918-525-0370. Permits expire if work is not started within 180 days of issuance or if work is suspended for 180 days. LOCAL GOVERNMENT APPROVALS Zoning approval verified: ❑ Yes ❑ No Property is within flood plain: ❑ Yes ❑ No Sanitation approval verified: ❑ Yes ❑ No CATEGORY OF CONSTRUCTION ©G Residential 1 ❑ Government 10 Commercial JOB SITE INFORMATION AND LOCATION Job site addres i 5112ee' City: S ixol �� (n county: 9 7 y7 State: Q Q ZIP: C 7 Cf % Subdivision: Space/lot no.: Reference: Taxlot:/70.2 ?j 3112 / FcO DESCRIPTION OF WORK ,,,?O/ 60/ ) C,14r A"c_ 1,71 -em Year Manufactured: 2 C>,( '7 # Bedrooms: tl Sq. Ftg: / 517 / Value: 56P06 PROPERTY OWNER Name: M [ zL & Address: Z/ a.qe( j 40? City: `ey�v"U ` State: 6a ZIP: '17119f Phone: O 6 Fax: E-mail: Lp . 2E t 1 This installation is being made on residents or farm property owned by me or a member of my immediate family, and is exempt from licensing requirements under OAR 910010. Signature: ONTRACTOR INSTALLATION Business name: eG/YtE-- Address: /6 79w'?_ City: State: ZIP: Phone: - - Fax: - - E-mail: CCB license no.: / 6 7 % MDI license no.: / 9 -7 Print name: 5 �a Signature: _ /���� ` i - last edited 5/5/2017 BJones FEE SCHEDULE Description Qty. Cost each Total (1) Manufactured dwelling (a) Placement (includes placement, electrical feeder, water/sewer connection): $537.00 $ (b) Reinspection (no. of hrs. x fee per hr.): $99.00 $ Placement permit can only be obtained by homeowner or Oregon - licensed manufactured dwelling installer. (2) Recreational -park trailer (a) Installation (includes stand and lot preparation; support blocking; anchoring; temporary steps; plumbing, mechanical, and electrical): $537.00 $ (b) Reinspection (no. of hrs. x fee per hr.): $99.00 $ (c) Each additional inspection: (1) $99.00 $ Electrical service permit to be obtained only by homeowner performing work or signing supervisor of Oregon -licensed electrical contractor performing work. FEE SCHEDULE (3) Surcharge, 12% (.12 x total, equal to I or 2): $ (4) State administrative fee for manufactured dwelling (item 1) only, OAR 918-500-0105(5): $30.00 1 $30.00 (5) Technology Fee, 5% $ TOTAL fees and surcharges (3 + 4+5): $ E1 V G — . �. JOURNAL OR JOB NUMBER: NAME OR COMPANY: LOCATION: TAX LOT NUMBER: DEVELOPMENT TYPE: NEW DWELLING UNITS IMPERVIOUS AREA CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT WORKSHEET 19-000836 Monkey Hero LLC 5550 A St 170233421300 Single Family Residence BUILDING SIZE (; MAX 45% 1. STORM DRAINAGE NUMBER OF FEU s A. REIMBURSEMENT COST: DIRECT RUNOFF TO CITY STORM SYSTEM 1 $131.89 B. IMPROVEMENT COST: ADT TRIP RATE A. REIMBURSEMENT COST NUMBER OF UNITS AREA DRAINING TO COST PER TRIP x IMPERVIOUS S.F. x COST PER S.F. DRYWELL CHARGE 1512.00 $0.294 = 0 $444.53 $444.53 B. IMPROVEMENT COST B. IMPROVEMENT COST: 1 $22.82 IMPERVIOUS S.F. x COST PER S.F. x CHARGE x 1512.00 $0.424 = 0 $641.09 $641.09 ITEM 1 TOTAL - STORM DRAINAGE SDC $1,085.62 $366.41 2. SANITARY SEWER - CITY 1.00 = A. REIMBURSEMENT COST: NUMBER OF DFU's x COST PER DFU 25 $165.54 = $4,138.50 B. IMPROVEMENT COST: NUMBER OF DFU's x COST PER DFU 25 $81.54 = $2,038.50 ITEM 2 TOTAL - CITY SANITARY SEWER SDC = $6,177.00 3. TRANSPORTATION NUMBER OF FEU s A. REIMBURSEMENT COST: 1 $131.89 B. IMPROVEMENT COST: ADT TRIP RATE x NUMBER OF UNITS x COST PER TRIP x NEW TRIP FACTOR 1$1,597.44 9.57 1 19.28 x 1.00 = B. IMPROVEMENT COST: 1 $22.82 ADT TRIP RATE x NUMBER OF UNITS x COST PER TRIP x NEW TRIP FACTOR 9.57 1 $366.41 1.00 = ITEM 3 TOTAL - TRANSPORTATION SDC A. REIMBURSEMENT COST: NUMBER OF FEU s x COST PER FEU 1 $131.89 B. IMPROVEMENT COST: NUMBER OF FEUs x ICOST PER FEU 1 1$1,597.44 C. COMPLIANCE COST: NUMBER OF FEU's x COST PER FEU 1 1 $22.82 MWMC CREDIT IF APPLICABLE (SEE REVERSE) MWMC ADMINISTRATIVE FEE ITEM 4 TOTAL - MWMC SANITARY SEWER SDC SUBTOTAL (ADD ITEMS 1, 2, 3, & 4) $3,691.05 $1,638.15 $12,591.82 1070 1091 1092 1093 1094 _ $131.89 1054 $1.597.44 1055 $22.82 ($124.01 ern nn 5. ADMINISTRATIVE FEE: SUBTOTAL x I ADM. FEE RATE = CHARGE $12,591.82 1 5% $629.60 TOTAL STORM ADMINISTRATION FEE $54.28 TOTAL SEWER ADMINISTRATION FEE: 308.85 TOTAL TRANSPORTATION ADMINISTRATION FEE: $184.55 TOTAL MWMC ADMINISTRATION FEE - LOCAL 581.91 PREPARED DATE 5/16/2019 TOTAL SDC CHARGES = I $13,221.42 105, 1056 DRAINAGE FIXTURE UNIT (DFU) CALCULATION TABLE NUMBER OF NEW FIXTURES x UNIT EQUIVALENT = DRAINAGE FIXTURE UNITS (NOTE: FOR REMODELS, CALCULATE ONLY THE NET ADDITIONAL FIXTURES) _ FIXTURE TYPE NO. OF FIXTURES UNIT NEW OLD EQUIVALENT DRAINAGE FIXTURE UNITS BATHTUB 2 0 3 = 6 DRINKING FOUNTAIN 0 0 1 = 0 FLOOR DRAIN 0 0 3 = 0 INTERCEPTORS FOR GREASE / OIL / SOLIDS / ETC. 0 0 3 = 0 INTERCEPTORS FOR SAND / AUTO WASH / ETC. 0 0 6 = 0 LAUNDRY TUB 1 0 2 = 2 CLOTHESWASHER / MOP SINK 1 0 3 = 3 CLOTHESWASHER - 3 OR MORE EA 0 0 6 = 0 MOBILE HOME PARK TRAP (I PER TRAILER) 0 0 12 = 0 RECEPTOR FOR REFRIG / WATER STATION / ETC. 0 0 1 = 0 RECEPTOR FOR COM. SINK / DISHWASHER / ETC. 1 0 3 = 3 SHOWER, SINGLE STALL 0 0 2 = 0 SHOWER, GANG (NUMBER OF HEADS) 0 0 2 = 0 SINK: COMMERCIAL/RESIDENTIAL KITCHEN 1 0 3 = 3 SINK: COMMERCIAL BAR 0 0 2 = 0 SINK: WASH BASIN/DOUBLE LAVATORY 0 0 2 = 0 SINK: SINGLE LAVATORY/RESIDENTIAL BAR 2 0 1 1 1= 2 URINAL, STALL / WALL 0 0 5 = 0 TOILET, PUBLIC INSTALLATION 0 0 6 = 0 TOILET, PRIVATE INSTALLATION 2 0 3 = 6 MISCELLANEOUS DFU TYPE NUMBER OF EDU'S 20 = TOTAL DRAINAGE FIXTURE UNITS *EDU (Equivalent Dwelling Unit) is a discharge equivalent to a single family dwelling unit (20 DFU's) set at 167 gallons per day 0 25 MWMC CREDIT CALCULATION TABLE: BASED ON COUNTY ASSESSED VALUE YEAR ANNEXED CREDIT RATE/$1,000 ASSESSED VALUE $5.29 $5.29 $5.19 $5.12 $4.98 $4.80 $4.63 $4.40 $4.07 $3.67 $3.22 $2.73 $2.25 $1.80 $1.59 $1.45 $1.25 $1.09 $0.92 $0.72 $0.48 $0.28 $0.09 $0.05 IS LAND ELGIBLE FOR ANNEXATION CREDIT? 1 (Enter 1 for Yes, 2 for No) IS IMPROVEMENT ELGIBLE FOR ANNEX. CREDIT? 1 (Enter 1 for Yes, 2 for No) BASE YEAR 1979 CREDIT FOR LAND (IF APPLICABLE; VALUE/ 1000 CREDIT RATE $23.44 x $5.29 = $124.00 CREDIT FOR IMPROVEMENT (IF AFTER ANNEXATION) VALUE/ 1000 CREDIT RATE $0.00 x $5.29 = 0 TOTAL MWMC CREDIT = $124.00 BEFORE 1979 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 r ' Sem k I i I I e J A 7� I b0. aI I 152-1 57 Fr -- I I �,Or rZ0 i r i r i ! NoT a5 S Ewe o- 1 0 Q/13 00- a:L 1 u - l %^ .0 - Cr- + .. . . 0.1 ...... .... ...... ..... .... _ /00 ' ®i 3 � v - C • �o f � 3 � ,aap zdp. � • t • 67 � � _ 0 ii s rti �3' o Id L3 e4 � v - C 3 � • • 00 •••• l: PiEINC.PACI1�IC' 1 � ORTIINVEST ENGINEERING, N Cornerstone Foundation System LLC July ]1, 2018 140 Art Mill Lane Roseburg, OR 97471 PATENT No. US 9,109,355 Bl Re: Design Criteria Verification "Smart Foundation" Running Bond 54 (SFRB-54), Ledge Stone 60 (SFLS-60), Smooth 60 (SFS - 60), and "Poured in Place" Footing or "Poured Concrete Runners". Pre -cast Concrete PC -48 Footing (16" x 48" x 2 ';2"), Pre -cast Concrete Masonry Unit Footing (CMU 16" x 16" x 4"), Composite Board Footing (1 '/" x 6") or Pressure Treated Lumber Footing (2" x 6"). Dear Norris. At the request of Cornerstone Foundation System LLC, Pacific Northwest Engineering has reviewed the empirical testing perfon ned by Cornerstone Foundation System, as witnessed and documented by Umpqua Testing Services. It is my conclusion the test results and calculations prove that the "Smart Foundation" Running Bond 54 (SI,RB-54), Ledge Stone 60 (SFLS-60), Smooth 60 (SFS -60), and Pre -cast Concrete PC -48 Footing (16"x 48" x 2 'i2"), Pre -cast Concrete Masonry Unit Footing (CMU 16" x 16" x 4"), Composite Board Footing (1 '/" x 6") or Pressure 'Treated Lumber Footing (2" x 6") when used in conjunction with Cornerstone Foundation System is acceptable as a tie down, perimeter pier and permanent foundation system, with a lateral and vertical force resisting system for wind zones 1, II, and III with a "C" exposure and a seismic designs category "DII", Ss=1.384, Fa=1.0, R=5 lateral load. In addition, an 801b./ Sq. Ft. roof load and up to a 30" lateral soil loads may be resisted simultaneously. SFRB-54. SFS -60, and SFLS-60 also meet or exceed the design requirements of "poured in place" or "poured concrete runners" type foundation from the "Permanent Foundation Guidebook for manufactured Housing' 4145.1 Rev. 2 and 4150.1 Rev (1996) and also with the manufacturer pier point layout. The installation also meets or exceeds the design requirements of the HUD 7584 Handbook. This allows the SFRB-54, SFLS-60 and SFS -60 to meet foundation certification for all HUD, FHA and VA lending on Manufactured Housing provided that the SFRB-54, SFI>S-60 and SFS -60 installation instructions are followed. It also meets or exceeds the requirements of Section 1333, Chapter 2, Title 25 of the California Administrative Code and 18551 of the Health and Safety Code. Cornerstone Foundation System meets or exceeds the Oregon 2010 Manufactured Dwelling Installation Specialty Code and the Model Manufactured Housing Installation Standards. Cornerstone Foundation System can also be used in flood hazard areas except with composite board or pressure treated lumber footing which allows up to 40 lbs. roof load and 24" soil back fill. 'fest results and engineering calculations are available to authorities having jurisdiction when requested. 0000. '• •:AnditiokaNttorniaticn 00•0 • S Qntact Person: Norrisa Ahlgren (l` 0 •..'Cornersida(s4oundation System LLC' :••Pleone: (541JY33-544J • •' Eiliail: do ierstonefouticfationsysteni@yahoo.corn •• 1` WORK BIl.i.l NC. ('(iRKP:RS"T'l7Kl� l�C�'•• • 00f0 00000 ..r 0. • • 1 •••� ••�;�• 4242 Silver Falls Dr. N., Silverton, OR. 97381 ph # (503) 873-3184 fax # (503) 873-3907 P.E. # 13,676 P�N�E T � , i 1 AC1 FIC N OR'I'HN'I EST ENGINEERING' ! NC. wall panel tight to the bottom of rim joist. Three sets of evenly spaced wedges are required per precast concrete foundation wall panel. A wedge set is two, a set can be two wedges side by side or two wedges inverted on top of one another, or any combination to consist of six total wedges per precast concrete foundation wall panel. *See it edge Set Placement. PRECAST FOOTING ANCHORS CFS is designed to be used on various/multiple footing options: Precast Concrete Masonry Unit 16" x 16" x 4" thick footing pad, Composite Board (decking material) 1 '/"x 6" wide, ground contact approved pressure treated lumber 2"x S" wide, or CFS PC -48 16" wide x 48" long x 2 `h" thick. Each footing option is secured to the ground using '/," diameter 14" Linc plated steel lag bolt anchors. On a 12' singlewide manufactured home ground anchor placement is approximately 16" on center. For larger width homes ground anchor placement is approximately 24" on center. Test results show each 'h" diameter 14" zinc plated steel lag bolt anchor resists 1,566 lbs. PRESCRIPTIVE CODE FOOTINGS POURED IN PLACE or POURED CONCRETE RUNNERS Poured in place footing or Poured concrete runner footing used in conjunction with Cornerstone Foundation Systems' structural precast concrete foundation wall panel, provides simultaneous perimeter wall support for a manufactured home with a roof load up to 80 lbs. psf. Wind anchoring for zones 1, 11, and III, Exposure C, bracing for seismic design category D11, soil back fill and flood plain up to 30 inch on precast concrete foundation wall panel. *See Poured it? Placa Footing Installation Instructions ci Smart l-uundation RI3-54, S-60 and LS -60 Installation Instructions. PRECAST CONCRETE MASONRY UNIT (CMU) FOOTING PAD Precast concrete masonry unit (CMU) 16" x 16" x 4" thick footing pad used in conjunction with Cornerstone Foundation Systems' structural precast concrete foundation wall panel provides simultaneous perimeter wall support for a manufactured home with a roof load up to 80 lbs. psf., wind anchoring for zones 1, 11 and III, Exposure C, bracing for seismic design category D1I, soil back fill and flood plain up to 24 inch on precast concrete foundation wall panel. Precast CMU footing pad must be Predrilled at a vertical or slight angle hole reasonably centered in the CMU footin a ' " e CMI.I footing pad is.anchored ..19.the groudd with 14," diameter 14" zinc plated steel • • • Iag bolt a i'4or date-rs •through the '/," predrilled ;•' little of f'N'111,footinepaa into the ground. ,• *Sce Precast C'on"cr•etc; Masonry Unit (CMU) ••••16'x16;',.�Sq.turc> 4" 77iicic looting Pad 5ca'/� ... Jvgtallatiora htstrua•ti®yrs• cC Smart Foundation RP- _ • •� S-6(#.gAd LS -60 fnsrrf'lation Instructions. •••• •,•,•• 4242 Sihc>r Fails Dr. N., Silverton. 97381 plr # (503) 873-3184 fax # (503) 873-3907 P.E. # 13,676 .. PACIFIC 1'l ORTHNVEST ENGINEERING, 1, NC. MANUFACTURERS DESCRIPTION Cornerstone Foundation System is a precast concrete foundation system specifically designed for Manufactured I,iornes..The design objective was to develop a permanent structural foundation system for manufactured homes, which simultaneously functions as a tie -down and perimeter pier foundation system that not only supports the rim joist continuously in the same manner as a stem wall foundation, but also eliminates any unsecured gap at the top and bottom of the homes perimeter. Cornerstone Foundation System within its unique patented design is the only precast concrete permanent structural foundation system with versatile footing options i.e.; cast in place stab or poured runners, precast concrete footing and composite board or pressure treated lumber. Cornerstone Foundation System is installed atter the home is set or can be retrofit to an existing hone. In the approval process for the Authorities having jurisdiction it is important to note Cornerstone Foundation System, is a precast concrete foundation system that simultaneously provides: • Crawl space enclosure • Continuous perimeter support + Wind anchoring tie down • Seismic bracing • Water and rodent seal Cornerstone Foundation System is a unique custom design not specified in the Model Manufactured Home Installation Standards (MMHIS) therefore, it is classified as an alternative method of construction. The requirement for an alternative method of construction is to provide undeniable proof by empirical testing that the design will resist all anticipated loads. The load points and shear load designs for Cornerstone Foundation System are the same as a stem wall foundation or pony wall foundation. It is required by MMHIS fair a precast concrete structural member prefabricated or manufactured off site to have a quality control program that is monitored with quarterly inspections by an independent third party testing company. Umpqua Testing Service an accredited concrete • •testing cegivany is contracted by Cornerstone • •'PQundat op •Systema" t6 .rmaintain quality control • : : pro gran;. • • ...... j •• • �ornersic#'Ho •;oundation System takes pride in the ,r• ••rCl�entic4s I.ItLrsuit tp'41rt.improvement of quality, •performrace and style for manufactured home 4� .... ...... ...... ...... .... � • • Y Y • • • • 4242 Silver Falls Dr. N,, Silverton, OR. 97381 • • • • pli # (503) 873-3184 fax # (503) 873-3907 Y.E. # 13,076 CONNECTO12S INSIDE. & OUTSIDE WALL RIM JOIST- TOP OIS - TOP CONNECTOR SCREW 1/4"X2 1/4" INTO FLIM JOIST-- TOP OIS rTOP CONNECTOR PLATE --._- TOP CONNECTOR SCREW - 1/4'X2 1/4" INTO PANEL CONNECTORS INSTALLED INSIDE OF WALL BOTTOM CONNECTOR SCREW 1/4'X2 1/4" INTO PANE BOTTOM CONNECTOR PLA411 WEDGE S BOTTOM CONNECTOR SCREW 1/4'X2 INTO FOOTING FOOTING TOP & BOTTOM CONNECTOR PLATES IM JOIST SIDING -Bl16" SIDING TOP CONNECTOR SCREW 1/4"X2 1/4" NTO RIM JOIST OP CONNECTOR PLATE OP CONNECTOR SCREW 1/4"X2 1/4" INTO PANEL CONNECTORS INSTALLED OUTSIDE OF WALL ' BOTTOM CONNECTOR SCREW '/4'X2 1/4' INTO PANEL R"'TTOM CONNECTOR PLATE _ f)r F SET _ OM CONNECTOR SCREW 1/4"X2 1/4" FOOTING INTO FOOTING E4 Manufactured from hich tensile steel banding material 1 '/4"..0;1 thick at 5000 lb!, tensile. strength. Connector }dates are'punched and cut to size then `Linc dated. 9/64" holes l.. r 2 1/4" ZZ •••• •••••• •••••• •• •• 7/5" 0000 • • • l.. r 2 1/4" CORNERSTONE FOUNDATION SYSTEM, LLC. 140 AR -1 ALTER ATF FOOTING: CORNERSTONE FOUNDATION SYSTEM PRECAST CONCRETE_FOOTI LG PAD BRAND WAME PC -4R INSTAI I ATION 112 " THICK. 30„ PRFCAST CONCRETE FOOTING PAD BRAND NAM PC -49 INSTAI I ATION INSTRUCTIONS (SEE ALSO SMART FOUNDATION INSTALLATION INSTRUCTIONS) SwC I Fw1DF: MINIMUM 11' 6" 4) LONG WALLS: SMALL HAVE A DOURI FWIDF 20 FOOT AND LANDER AND AQUI TISFCTION HOM S (THREE OR MORE SECTIONS): • :i� :;ROOMED FLAT WITHOUT ABRUPT UNDULATIONS. • P.fair ='� r.:. T - if • PREDRILLING IS PERMITTEE •. E -i;�° f+ I WHEN DRILLING OR LAGGING ZINC PLATED LAG ZI 4112• X 14" 7JNC PLATED LAG BOLT i --- ? 1 / ' • DIAMETER HOLES • o- 1n• of 00 •• ••• ••• ••• i• •• •• • •• N•. •�- _..-__— REaRi t(o Y - X •! ' 2e _12 •B:_ -i • • • • y _ . l J - ypp PS -. F BED�ACR ESIGT REW�•••• ••• DIGPAD: ' I BUILDING IME SOS RE1AtEyE� AT1o4 •.•••• • ,�p106WBED;/t-. MINUS ••••• •- {���F-D 34 J . •••• •••••• •••••• • • •• • •••••• •• • • • •• 0000 • 0 0 CORNERSTONE FOUNDATION SYSTEM LLC. 140 441 _ B PRECAST CONCRFTF MASQ�y_LlNLT_.LCMU) 16"X16" SQUARE X4" THICK FOOTING PAD NSIALLATION DESIGtl PRECAST CONCRETE MASONRY UNIT (CMU ) _lfi"X16"X4" THICK FOOTING PAD INSTAI I ATION INSTRUCTION (SEE ALSO SMART FOUNDATION INSTALLATION INSTRUCTIONS) SINGLE -WIDE MINIMUM 11'6- OR WIDER DOUBLEWIDE ZOLM-M. EQ ZINC Mll TIS .TlQR—CTHR1=F OR MORF SECTIONS -1 • .r.._ I'. I• CAU, IC- .. 6 —7 112" X 14" ZINC PLATED LAG BUT r j k}'irj 5 311rf ., RE DRILL 1/ vcR'I AL's HOLEL ... e • • • e . ._._o -_r . • • • • • _--- • •�•- GApJ�ffY 15� . SOL • • • • • ____�----• —•': VE ALL VENATION BWWVPA�D •— U i,),STU�QeNATlN. SOIL • 3/4. MINUS so** • •fI *PAL`T see***l • e • ease • e e Future after partition 0 CV co O 1 ti T DATE RE. EI1/ED04/18/19 JOBNO.19-000836 ZONELDR OCCUPANCY + GROUP R3 UNFT OCCUPANCY LOAD 58'-0" STI OFUES TYPE CONSTRUCT10N MD };.;: LEGAL DESCRIPTION 170233421300 t'Y.+.4'Y.+. 4'r.+.4'N.t 4'.+.t 4'Y.+. 4'Y.+.4'~.+.••'1.1.4' �- _ _ _ _ -- 1 ADDRESS 5550 A ST P'ARC'EL : l'tC3pfised +• • 1 F OWNER MONKEY HERO LLC PARCEL 2: Permitted 5540 p Street 1 5550 A Street .'1'.'.'.'.-.'.'• .'1'.• 1 1 _.._._. , -THE CONTENTS EIERE ONHAVE BEEN REVIEWED,WrIH '" , ,AIS TE NATIONS NOTED ON THE PLANS OR BY ATI'ACEIMENT. :1: 1 f : CHANGES OR ALTERATIONS MADE TO `IM APPROVED 56' x 27' 4bd 2ba :: = :`•:X: :: : ' .;f;.; DRAWINGSOR PROJECTAFTER ME DATE BELOW SEIALL RE : ' : :; ;:;:;:;:':,:;:" •','•' 1521 sq ft house APPROVED BYTHE B'UMDING OFFICIAL. :1: + rff OF SPRINGFIELD, OREGON �• 1 AW ,• 1 :+: 1 .•1•.• 1 1 APPROVED BY DATE u X Z'0749 :r',FRIaPardn :n:;;Parking NOTICE: This permit shall expire if the work authorized under this Ma permit is not commenced or is abandoned for any 180 day period. ATTENTION: Oregon law requires you to follow rules adopted by the :�'k.N.A.: ' :�::: Oregon Utility Notification Center. Those rules are set forth in OAR Infiltration Rain _ 952-001-0010 through 952-001-0090. You may obtain copies of the rules Garden by calling the center. (Note: The administrative telephone number for the Oregon Utility Notification Center is 800 332 2344. 1 1 9 Y ( ) o Connect Sanitary Sewer to 4" service connection. Field verify rY Y :;.: 1 in location. 18x11 Connect Storm Sewer to on site rain garden facilities. , -----------------' MINIMUM SETBACKS- INTERIOR LOTS .; All measurements are from Property lines 100'-11° — -Front Yard to House 10 feet -Front Yard to Garage 18 feet Notes: Proposed lot line -Side Yard to House or Garage 5 feet 1. Setbacks are 10' front and back and 5' interior/side lines, denoted -Rear Yard to House or Garage 10 feet by dotted lines. P.U.E. MAY CHANGE SETBACKS ' 2. Utilities (Power, Sewer, Water) are set in a trench along the East side of the handle. ' 3. All utilities are in place for both parcels. There are two 4" inch, pipes for the sewer, one for each parcel. There are two separate water lines, being metered by SUB. A power junction box is across •+" the driveway in the easement on Parcel 1. • 4. Soil percolation tests were conducted by Branch Engineering. "" • • • } • 5. The hatched area represents the driveways for the properties. • • • • • .Jf • 6. The hatched and dotted area represents the proposed pl'ivate - •., .. / easement for utilities and ingress/egress to Parcel 2. •: / r 7 The handle of the driveway, as requested by the Fire Department, - • • is 8" compressed gravel. The driveway through the handle is 21' F wide. '�."' "'a'r • Pflwet TENTATIVE PARTITION PLAN �•' ••- •- r4-25'-0' Pole 5550 A STREET 1702334201300 A Street