Loading...
HomeMy WebLinkAboutPermit Building 2019-02-19THIS IS AN EXISTING SPRINT WIRELESS TELECOMMUNICATION FACILITY B4 UPGRADE \ Sprint` ® E U G 17 3 fiSPRINT PARKWAY OVERLANDPARK, KS66251 Sprint 11PP•#. ,392227 P063XCO12 / CCI SITE # 879620 - - '' TM .,CA TLE CONSTRUCTION DRAWINGS 1505 WESTLAKE AVE WA 989iTE 808 SEATTLE. WA 98109 F: S�� S MORRISON HERSHFIELD • PROJECT DATA PROJECT CONTACTS DRAWING INDEX' SHEET DESCRIPTION SITE ADDRESS: 333 58TH STREET GOVERNING CODES APPLICANT SPRINGFIELD, OR 97478SPRINT ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED SPECTRUM LP -JODI JONES 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING LATITUDE: 44°02'50.17" N 8305 SW CREEKSIDE PLACE, SUITE C T-1.0 TITLE SHEET BEAVERTON, OR 97007 Tel. 206 268.7370 CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES, LONGITUDE: -122°55'25.45" W NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK jodi.jones@sprintcom N-1.0 GENERAL NOTES www.mordsonhershfield.com NOT CONFORMING TO THESE CODES. N-2.0 GENERAL NOTES OREGON STATE AND LOCAL BUILDING CODES WITH THE FOLLOWING PROJECT MANAGER A-1.0 OVERALL SITE PLAN JURISDICTION: CITY OF SPRINGFIELD REFERENCE CODE: PARCEL NUMBER(S): 17023432-00100 CROWN CASTLE - AARON HOTTELL A-2.0 COMPOUND PLAN 1505 WESTLAKE AVE N, SUITE 800 �REp q Rcy 2014 OREGON STRUCTURAL SPECIALTY CODE ZONING CLASSIFICATION: PUBLIC LAND AND OPEN SPACE • 2014 NATIONAL ELECTRICAL CODE SEATTLE, WA 98109 A-3.0 ANTENNA CONFIGURATIONS PHONE: 206.336.3225 • 2014 OREGON MECHANICAL SPECIALTY CODE GROUND ELEVATION: 515 FT AMSL 2012 NFPA 101 LIFE SAFETY CODE aaron.hottell@crowncasde.com A-4.0 EXISTING & PROPOSED WEST ELEVATION ROBERT J . ,A • TOP OF TOWER: 85'-Q" CONSTRUCTION MANAGER Afi.O CONSTRUCTION DETAILSCROWN LL/ LARA OCCUPANCY GROUP: UTILITY CASTLE - DAVID WATKINS 1505 WESTLAKE AVE N, SUITE 800 E-1.0 GROUNDING DETAILS Licens # 5897 A.D.A. COMPLIANCE CONSTRUCTION TYPE: 11-B INSTALLATION IS UNMANNED AND NOT FOR HUMAN HABITATION. SEATTLE, WA 98109 N T F HANDICAP ACCESS IS NOT REQUIRED PER A.DA. PHONE: 541.784.5730 davtd.watklns@crowncastle.com 1PROPERTY 1T SHALL K LL EXPIRE IFTHE 1Npp� 01 .21 OWNER �1 THUURSTONSCHOOL DISTRICT 'ED UNDER HIS PERMIT NOT '��49:47-05� �O -IS 33358TH STREET ED Ufl IS AI3AI�IDOI�JED FOR SPRINGFIELD, OR 97478 fl FOF O PROJECT SUMMARY DRIVING DIRECTIONS a DAY PERIOD. ROBERT JERRY LARA REGISTERED ARCHITECT TOWER OPERATOR CROWN CASTLE USA 1505 WESTLAKE AVE N, SUITE 800 p 9 —i�Ya^ Q( DATE RECEIVED (! /19 JOB NO, 1 �scrl Cl`�� STATE OF OREGON 5897 SPRINT PROPOSES TO MODIFY AN EXISTING UNMANNED FROM PORTLAND INTERNATIONAL AIRPORT: TELECOMMUNICATIONS FACILITY 1. FOLLOW SIGNS TO I-205 S; MERGE ONTO I-2055 SEATTLE, WA 98109 SP1-- MH PROJECT NO.: 7170159 • REPLACE (3) PANEL ANTENNAS 2. AT EXIT 21 B, TAKE RAMP RIGHT FOR 1-84 WIUS-30 W TOWARD PORTLAND ZONE OCCUPANCY GROUP • INSTALL (3) RRH 3. TAKE RAMP LEFT FOR 1-5 S TOWARD BEAVERTON/SALEM 4. AT EXIT 194 A, TAKE RAMP RIGHT FOR OR -126 E TOWARD SPRINGFIELD ZONING &PERMITTING CONSULTANT UNIT OCCUPANCY LOAD RELEASE 5. KEEP STRAIGHT ONTO OR -126 E 6. USE THE LEFT 2 LANES TO TURN LEFT ONTO MAIN STIMCKENZIE HWY. CROWN CASTLE - ZACH PHILLIPS 1505 WESTLAKE AVE N, SUITE 800 STORIES TYPE CONSTRUCTION NO. DATE D C DESCRIPTION q 06/1671-7 BA 90% CD REVIEW 7. TURN LEFT ONTO 58TH ST. DESTINATION WILL BE ON THE RIGHT SEATTLE, WA 98109 PHONE: 503.708.9200 LEGAL DESCRIPTION I O Z 4 Z Q(' B 02/05/18 CW 95% CD REVIEW ADDRESS 3 5 C 04/18718 JA 987 CD REVIEW D 11/28/18 JA 99% CD REVIEW A&E CONSULTANT 55�� /� B� OWNER S P121(�l Fi SC 14DOL 0 12721718 JA 100% CD FINAL MORRISON HERSHFIELD _ L) i s �� G—/ V 1 ROY LORETE MANLIFf REQUIRED 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 THE CONTENTS HERE ON HAVE BEEN REVIEWED, WITH TEL: 206.268.7370 ALTERATIONS NOTED ON THE PLANS OR BY ATTACHMENT. CHANGES OR ALTERATIONS MADE TO THE APPROVED PROFESSIONAL OF RECORD MORRISON HERSHFIELD CORPORATION DRAWINGS OR PROJECT AFTER THE DATE BELOW SHALL SITE NUMBER G. LANCE COOKE BE APPROVED BY THE BUILDING OFFICIAL. p063XC012 PROJECT VICINITY MAP PHONE: 503.924.2515 CCI SITE # 879620 PROFESSIONAL OF RECORD CITY OF SPRINGFIELD, OREGON MORRISON HERSHFIELD CORPORATION SITE NAME E U G 173 ROBERT LARA, AIA PHONE: 954.577.4655 APPROVED BY qTE �� SITE ADDRESS 333 58TH STREET RF ENGINEER SPRINGFIELD, OR 97478 SPRINT rnn,a...p,vmw. O 1000124TH AVE SUITE 201 BELLEVUE, WA 98080 05 APPROVAL LIST SHEET TITLE PROJECT► TITLE SIGNATURE DATE PROPERTY OWNER TITLE SHEET SITE / , >0 SPRINT REPRESENTATIVE - PROJECT MANAGER COMPAL� N SITE ACQUISITION SHEET NO. ZONING =Mwa W E Know what's below. CONST, MANAGER T-1.0 Call before you dig. RF ENGINEER S www.call8ll.com AAV MANAGER THESE OUTLINE SPECIFICATIONS IN CONJUNCTION WITH THE SPRINT STANDARD CONSTRUCTION SPEanCATIONS, INCLUDING CONTRACT DOCUMENTS AND THE CONSTRUCTION DRAWINGS DESCRIBE THE WORK TO BE PERFORMED BY THE CONTRACTOR. SECTION 01 100 - SCOPE OF WORK SECTION 01 400 - SUBMITTALS & TESTS ALTERNATES: THE WORK- AT THE COMPANY'S REQUEST, ANY ALTERNATIVES TO THE MATERIALS OR SHALL COMPLY WITH APPLICABLE NATIONAL CODES AND STANDARDS, LATEST EDITION, METHODS SPECIFIED SHALL BE SUBMITTED TO SPRINTS CONSTRUCTION AND PORTIONS THEREOF. MANAGER FOR APPROVAL SPRINT WILL REVIEW AND APPROVE ONLY THOSE REQUESTS MADE IN WRITING. NO VERBAL APPROVALS WILL BE CONSIDERED. PRECEDENCE: SHOULD CONFLICTS OCCUR BETWEEN THE STANDARD CONSTRUCTION SPECIFICATIONS FOR WIRELESS SITES INCLUDING THE STANDARD CONSTRUCTION DETAILS FOR WIRELESS SITES AND THE CONSTRUCTION DRAWINGS , INFORMATION ON THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE. SITE FAMILIARITY: - CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING WITH CONSTRUCTION. ON—SITE SUPERVISION: THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. DRAWINGS, SPECIFICATIONS AND DETAILS REQUIRED AT JOSSITE: THE CONSTRUCTION CONTRACTOR SHALL MAINTAIN A FULL SET OF THE CONSTRUCTION DRAWINGS AT THE JOBSITE FROM MOBILIZATION THROUGH CONSTRUCTION COMPLETION. A. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. B. CONTRACTOR SHALL NOTIFY SPRINT CONSTRUCTION MANAGER OF ANY VARIATIONS PRIOR TO PROCEEDING WITH THE WORK. DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. C. MARK THE FIELD SET OF DRAWINGS IN RED, DOCUMENTING ANY CHANGES FROM THE CONSTRUCTION DOCUMENTS. METHODS OF PROCLDURE (MOP) FOR CONSTRUCTION: CONTRACTOR SHALL PERFORM WORK AS DESCRIBED IN A. COAX COLOR CODING SWEEPS AND FIBER TESTING TS -0200 AND EL -0568 B. CABLE LABELING EN -2012-00 C. APPLICABLE INSTALLATION MOPS IDENTIFIED ELSEWHERE IN THE CONTRACT DOCUMENTS SECTION 01 200 — COMPANY FURNISHED MATERIAL AND EQUIPMENT COMPANY FURNISHED MATERIAL AND EQUIPMENT IS IDENTIFIED ON THE RF DATA SHEET IN THE CONSTRUCTION DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR SPRINT PROVIDED MATERIAL AND EQUIPMENT TO ENSURE IT IS PROTECTED AND HANDLED PROPERLY THROUGHOUT THE CONSTRUCTION DURATION. CONTRACTOR RESPONSIBLE FOR RECEIPT OF SPRINT FURNISHED EQUIPMENT AT CELL SITE OR CONTRACTORS LOCATION. CONTRACTOR TO COMPLETE SHIPPING AND RECEIPT DOCUMENTATION IN ACCORDANCE WITH COMPANY PRACTICE. NOTICE TO PROCEED: NO WORK SHALL COMMENCE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEED AND THE ISSUANCE OF WORK ORDER. SITE CLEANLINESS: NESS: CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH. AT THE COMPLETION OF THE WORK, CONTRACTOR SHALL REMOVE FROM THE SITE ALL REMAINING RUBBISH, IMPLEMENTS, TEMPORARY FACILITIES, AND SURPLUS MATERIALS. TESTS AND INSPECTIONS: A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION TESTS, INSPECTIONS AND PROJECT DOCUMENTATION. B. CONTRACTOR SHALL ACCOMPLISH TESTING INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1. COAX SWEEPS AND FIBER TESTS PER LATEST VERSION OF TS -0200 ANTENNA LINE ACCEPTANCE STANDARDS. 2. AGL, AZIMUTH AND DOWNTiLT PROVIDE AN AUTOMATED REPORT UPLOADED TO SITERRA USING A COMMERCIAL MADE -FOR THE PURPOSE ELECTRONIC ANTENNA ALIGNMENT TOOL (AAT). INSTALLED AZIMUTH, CENTERLINE AND DOWNTILT MUST CONFORM WITH RF CONFIGURATION DATA. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL CORRECTIONS TO ANY WORK IDENTIFIED AS UNACCEPTABLE IN SITE INSPECTION ACTIVITIES AND/OR AS A RESULT OF TESTING. 4. ALL TESTING REQUIRED BY APPLICABLE INSTALLATION MOPS. C. REQUIRED CLOSEOUT DOCUMENTATION INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: 1. AZIMUTH, DOWNTILT, AGL FROM SUNSIGHT INSTRUMENTS - ANTENNALIGN ALIGNMENT TOOL (AAT) 2. SWEEP AND FIBER TESTS 3. SCALABLE BARCODE PHOTOGRAPHS OF TOWER TOP AND INACCESSIBLE SERIALIZED EQUIPMENT 4. ALL AVAILABLE JURISDICTIONAL PERMIT AND OCCUPANCY INFORMATION 5. PDF SCAN OF REDLINES PRODUCED IN FIELD 6. A PDF SCAN OF REDLINE MARK-UPS SUITABLE FOR USE IN ELECTRONIC AS -BUILT DRAWING PRODUCTION 7. LIEN WAVERS 8. FINAL PAYMENT APPLICATION 9. REQUIRED FINAL CONSTRUCTION PHOTOS 10. CONSTRUCTION AND COMMISSIONING CHECKLIST COMPLETE WITH NO DEFICIENT ITEMS 11. APPLICABLE POST NTP TASKS INCLUDING DOCUMENT UPLOADS COMPLETED IN SITERRA (SPRINTS DOCUMENT REPOSITORY OF RECORD) 12. CLOSEOUT PHOTOGRAPHS AND CLOSEOUT CHECKLISTS: SPRINT WILL PROVIDE SEPARATE GUIDANCE SECTION 11 700 - ANTENNA ASSEMBLY, REMOTE RADIO UNIITS AND CABLE INSTALLATION SUMMARY THIS SECTION SPECIFIES INSTALLATION OF ANTENNAS, RRH'S AND CABLE EQUIPMENT, INSTALLATION, AND TESTING OF COAXIAL FIBER CABLE. ANTENNAS AND RRH'S: THE NUMBER AND TYPE OF ANTENNAS AND RRH'S TO BE INSTALLED IS DETAILED ON THE CONSTRUCTION DRAWINGS. HYBRID CABLE: HYBRID CABLE WILL BE DC/FIBER AND FURNISHED FOR INSTALLATION AT EACH SITE. CABLE SHALL BE INSTALLED PER THE CONSTRUCTION DRAWINGS AND THE APPLICABLE MANUFACTURER'S REQUIREMENTS. JUMPERS AND CONNECTORS_: FURNISH AND INSTALL 1/2" COAX JUMPER CABLES BETWEEN THE RRH'S AND ANTENNAS. JUMPERS SHALL BE TYPE LDF 4, FLC 12-50, CR 540, OR FXL 540. SUPER -FLEX CABLES ARE NOT ACCEPTABLE, JUMPERS BETWEEN THE RRH'S AND ANTENNAS OR TOWER TOP AMPLIFIERS SHALL CONSIST OF 1/2 INCH FOAM DIELECTRIC, OUTDOOR RATED COAXIAL CABLE, MIN LENGTH FOR JUMPER SHALL BE 10'-0". MISCELLANEOUS: INSTALL SPLITTERS, COMBINERS, FILTERS PER RE DATA SHEET, FURNISHI!tD 5Y SPRINT. ANTENNA INSTALLATION: •. • . . THE CONTRACTOR SHALL ASSEMBLE ALL ANTENNAS ONSITE IN ACCORDA4E•WITH THE INSTRUCTIONS SUPPLIED BY THE MANUFACTURER. ANTENNA HEIGHT, AZIMUTH, AND FEED ORIENTATION INFORMATION SHALL BE A DESIGNATED ON THE CONSTRUCTION DRAWINGS. • a A. THE CONTRACTOR SHALL POSITION THE ANTENNA ON TOWER PIPE Ij0UNT!; SO THAT THE BOTTOM STRUT IS LEVEL. THE PIPE MOUNTS SHALL BE PLUMBsTQ WkTHIN 1 • DEGREE. s • • • B. ANTENNA MOUNTING REQUIREMENTS: PROVIDE ANTENNA MOUNTING HARDWARE AS INDICATED ON THE DRAWINGS. HYBRID CABLE INSTALLATION: A. THE CONTRACTOR SHALL ROUTE, TEST, AND INSTALL ALL CABLES AS INDICATED ON THE CONSTRUCTION DRAWINGS AND IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. B. THE INSTALLED RADIUS OF THE CABLES SHALL NOT BE LESS THAN THE MANUFACTURER'S SPECIFICATIONS FOR BENDING RADIUS. C. EXTREME CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE CABLES DURING HANDLING AND INSTALLATION. 1. FASTENING MAIN HYBRID CABLES: ALL CABLES SHALL BE INSTALLED INSIDE MONOPOLE WITH CABLE SUPPORT GRIPS AS REQUIRED BY THE MANUFACTURER. 2. FASTENING INDIVIDUAL FIBER AND DC CABLES ABOVE BREAKOUT ENCLOSURE (MEDUSA), WITHIN THE MMBTS CABINET AND ANY INTERMEDIATE DISTRIBUTION BOXES: a. FIBER: SUPPORT FIBER BUNDLES USING 1/2" VELCRO STRAPS OF THE REQUIRED LENGTH @ 18" OC. STRAPS SHALL BE UV, OIL AND WATER RESISTANT AND SUITABLE FOR INDUSTRIAL INSTALLATIONS AS MANUFACTURED BY TEXTOL OR APPROVED EQUAL. b. DC: SUPPORT DC BUNDLES WITH ZIP TIES OF THE ADEQUATE LENGTH. ZIP TIES TO BE UV STABILIZED, BLACK NYLON, WITH TENSILE STRENGTH AT 12,000 PSI AS MANUFACTURED BY NELCO PRODUCTS OR EQUAL. 3. FASTENING JUMPERS: SECURE JUMPERS TO THE SIDE ARMS OR HEAD FRAMES USING STAINLESS STEEL TIE WRAPS OR STAINLESS STEEL BUTTERFLY CLIPS. 4. CABLE INSTALLATION: a. INSPECT CABLE PRIOR TO USE FOR SHIPPING DAMAGE, NOTIFY THE CONSTRUCTION MANAGER. b. CABLE ROUTING: CABLE INSTALLATION SHALL BE PLANNED TO ENSURE THAT THE LINES WILL BE PROPERLY ROUTED IN THE CABLE ENVELOP AS INDICATED ON THE DRAWINGS. AVOID TWISTING AND CROSSOVERS. c. HOIST CABLE USING PROPER HOISTING GRIPS. DO NOT EXCEED MANUFACTURERS RECOMMENDED MAXIMUM BEND RADIUS. .. NSI •�p�int 6391 SPRINT PARKWAY OVERLAND PARK, KS66251 "'CROWN CASTLE 1505 WESTLAKE AVE N, SUITE 800 SEATTLE. WA98169 FPAIA MORRISON HERSHFIELD 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 www.monisonhershfield.com ARc'yi ROB ERT J. A L RA Licen i# 5897 • F •' J+ 2018.12.21 9:41-05�O`� '91p: ' 0 F 0 ROBERT JERRY LARA REGISTERED ARCHH'ECT STATE OF OREGON 5897 MH PROJECT NO.: 7170159 SITE NUMBER P063XCO12 CCI SITE # 879620 SITE NAME EUG173 SITE ADDRESS 333 58TH STREET SPRINGFIELD, OR 97478 SHEET TITLE GENERAL NOTES SHEET NO. N-1.0 CONTINUE FROM N -1A 5. GROUNDING OF TRANSMISSION LINES: ALL TRANSMISSION LINES SHALL BE GROUNDED AS INDICATED ON DRAWINGS. 6. HYBRID CABLE COLOR CODING: ALL COLOR CODING SHALL BE AS REQUIRED PER LATEST VERSION OF TS 0200. 7. HYBRID CABLE LABELING: INDIVIDUAL HYBRID AND DC BUNDLES SHALL BE LABELED ALPHA -NUMERICALLY ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE - EN 2012-001, REV 1 WEATHERPROOFING EXTERIOR CONNECTORS AND HYBRID CABLE GROUND KITS: A. ALL FIBER & COAX CONNECTORS AND GROUND KITS SHALL BE WEATHERPROOFED. WEATHERPROOFED USING ONE OF THE FOLLOWING METHODS. ALL INSTALLATIONS MUST BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY BEST PRACTICES. 1. COLD SHRINK: ENCOMPASS CONNECTOR IN COLD SHRINK TUBING AND PROVIDE A DOUBLE WRAP OF 2" ELECTRICAL TAPE EXTENDING 2" BEYOND TUBING. PROVIDE 3M COLD SHRINK CXS SERIES OR EQUAL 2. SELF -AMALGAMATING TAPE: CLEAN SURFACES. APPLY A DOUBLE WRAP OF SELF -AMALGAMATING TAPE 2" BEYOND CONNECTOR. APPLY A SECOND WRAP OF SELF -AMALGAMATING TAPE IN OPPOSITE DIRECTION. APPLY DOUBLE WRAP OF 2" WIDE ELECTRICAL TAPE EXTENDING 2" BEYOND THE SELF -AMALGAMATING TAPE. 3. 3M SLIM LOCK CLOSURE 716: SUBSTITUTIONS WILL NOT BE ALLOWED. 4. OPEN FLAME_ ON -JOB SITE IS NOT ACCEPTABLE. SECTION 11 800 - INSTALLATION OF MULTIMODAL BASE STATIONS (MMBTS) AND RELATED EQUIPMENT SUMMARY: A. THIS SECTION SPECIFIES MMBTS CABINETS, POWER CABINETS, AND INTERNAL EQUIPMENT INCLUDING BUT NOT LIMITED TO RECTIFIERS, POWER DISTRIBUTION UNITS, BASE BAND UNITS, SURGE ARRESTORS, BATTERIES, AND SIMILAR EQUIPMENT FURNISHED BY THE COMPANY FOR INSTALLATION BY THE CONTRACTOR (OFCI) B. CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND PROVIDE ALL LABOR REQUIRED FOR INSTALLATION EQUIPMENT IN EXISTING CABINET OR NEW CABINET AS SHOWN ON DRAWINGS AND AS REQUIRE BY THE APPLICABLE INSTALLATION MOPS. C. COMPLY WITH MANUFACTURERS INSTALLATION AND START—UP REQUIREMENTS DC CIRCUIT BREAKER LABELING A. NEW DC CIRCUIT IS REQUIRED IN MMBTS CABINET SHALL BE CLEARLY IDENTIFIED AS TO RRH BEING SERVICED SUMMARY: THIS SECTION SPECIFIES BASIC ELECTRICAL REQUIREMENTS FOR SYSTEMS AND COMPONENTS. QUALM ASSURANCE: A. ALL EQUIPMENT FURNISHED UNDER DIVISION 26 SHALL CARRY UL LABELS AND LISTINGS WHERE SUCH LABELS AND LISTINGS ARE AVAILABLE IN THE INDUSTRY. B. MANUFACTURERS OF EQUIPMENT SHALL HAVE A MINIMUM OF THREE YEARS EXPERIENCE WITH THEIR EQUIPMENT INSTALLED AND OPERATING IN THE FIELD IN A USE SIMILAR TO THE PROPOSED USE FOR THIS PROJECT. C. MANUFACTURER$. QF_EQUIPMENT: ALL MATERIALS AND EQUIPMENT SPECIFIED IN DIVISION 26 OF THE SAME TYPE SHALL BE OF THE SAME MANUFACTURER AND SHALL BE NEW, OF THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS. SUPPORTING DEVICES: A. ALL EQUIPMENT FURNISHED UNDER DIVISION 26 SHALL CARRY UL LABELS AND LISTINGS WHERE SUCH LABELS AND LISTINGS ARE AVAILABLE IN THE INDUSTRY, MANUFACTURERS OF EQUIPMENT SHALL HAVE A MINIMUM OF THREE YEARS EXPERIENCE WITH THEIR EQUIPMENT INSTALLED AND OPERATING IN THE FIELD IN A USE SIMILAR TO THE PROPOSED USE FOR THIS PROJECT. MANUFACTURERS OF_,EljUIPMENT: ALL MATERIALS—AND EQUIPMENT SPECIFIED IN DIVISION 26 OF THE SAME TYPE SHALL BE OF THE SAME MANUFACTURER AND SHALL BE NEW, OF THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS. SUPPORTING DEVICES: A. MANUFACTURED STRUCTURAL SUPPORT MATERIALS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY THE FOLLOWING. 1. ALLIED TUBE AND CONDUIT 2. B -LINE SYSTEM 3. SUNISTRUT DIVERSIFIED PRODUCTS 4. THOMAS & BETTS B. FASTENERS: TYPES, MATERIALS, AND CONSTRUCTION FEATURES AS FOLLOWS: 1. EXPANSION ANCHORS: CARBON STEEL WEDGE OR SLEEVE TYPE. 2. POWER -DRIVEN THREADED STUDS: HEAT-TREATED STEEL, DESIGNED SPECIFICALLY FOR THE INTENDED SERVICE. 3. FASTEN BY MEANS OF WOOD SCREWS ON WOOD. 4. TOGGLE BOLTS ON HOLLOW MASONRY UNITS. 5. CONCRETE INSERTS OR EXPANSION BOLTS ON CONCRETE OR SOLID MASONRY. 6. MACHINE SCREWS, WELDED THREADED STUDS, OR SPRING -TENSION CLAMPS ON STEEL, 7. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE SHALL NOT BE PERMITTED. 8. DO NOT WELD CONDUIT, PIPE STRAPS, OR ITEMS OTHER THAN THREADED STUDS TO STEEL STRUCTURES. 9. IN PARTITIONS OF LIGHT STEEL CONSTRUCTION, USE SHEET METAL SCREWS. SUPPORTING DEVICES: A. INSTALL SUPPORTING DEVICES TO FASTEN ELECTRICAL COMPONENTS SECURELY AND PERMANENTLY IN ACCORDANCE WITH NEC. B. COORDINATE WITH THE BUILDING STRUCTURAL SYSTEM AND WITH OTHER TRADES. C. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, FASTEN ELECTRICAL ITEMS AND THEIR SUPPORTING HARDWARE SECURELY TO THE STRUCTURE IN ACCORDANCE WITH THE FOLLOWING: D. ENSURE THAT THE LOAD APPLIED BY ANY FASTENER DOES NOT EXCEED 25 PERCENT OF THE PROOF TEST LOAD. E. USE VIBRATION AND SHOCK -RESISTANT FASTENERS FOR ATTACHMENTS TO CONCRETE SLABS. ELECTRICAL IDENTIFICATION: A. UPDATE AND PROVIDE TYPED CIRCUIT BREAKER SCHEDULES IN THE MOUNTING BRACKET, INSIDE DOORS OF AC PANEL BOARDS WITH ANY CHANGES MADE TO THE AC SYSTEM. B. BRANCH CIRCUITS FEEDING AVIATION OBSTRUCTION LIGHTING EQUIPMENT SHALL BE CLEARLY IDENTIFIED AS SUCH AT THE BRANCH CIRCUIT PLANELOAD. SECTION 26 200 - ELECTRICAL MATERIALS AND EQUIPMENT CONDUn': A. RIGID GALVANIZED STEEL (RGS) CONDUIT SHALL BE USED FOR EXTERIOR LOCATIONS ABOVE GROUND AND IN UNFINISHED INTERIOR LOCATIONS AND FOR ENCASED RUNS IN CONCRETE. RIGID CONDUIT AND FITTINGS SHALL BE STEEL, COATED WITH ZINC EXTERIOR AND INTERIOR BY THE HOT DIP GALVANIZING PROCESS. CONDUIT SHALL BE PRODUCED TO ANSI SPECIFICATIONS C80.1. FEDERAL SPECIFICATION WW --C-581 AND SHALL BE LISTED WITH THE UNDERWRITERS' LABORATORIES. FITTINGS SHALL BE THREADED - SET SCREW OR COMPRESSION FITTINGS WILL NOT BE ACCEPTABLE. RGS CONDUITS SHALL BE MANUFACTURED BY ALLIED, REPUBLIC OR WHEATLAND. B. UNDERGROUND CONDUIT IN CONCRETE SHALL BE POLYVINYLCHLORIDE (PVC) SUITABLE FOR DIRECT BURIAL AS APPLICABLE. JOINTS SHALL BE BELLED, AND FLUSH SOLVENT WELDED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CONDUIT SHALL BE CARLON ELECTRICAL PRODUCTS OR APPROVED EQUAL. C. TRANSITIONS BETWEEN PVC AND RIGID (RGS) SHALL BE MADE WITH PVC COATED METALLIC LONG SWEEP RADIUS ELBOWS. D. EMT OR RIGID GALVANIZED STEEL CONDUIT MAY BE USED IN FINISHED SPACES CONCEALED IN WALLS AND CEILING. EMT SHALL BE MILD STEEL, ELECTRICALLY WELDED, ELECTRO -GALVANIZED OR HOT -DIPPED GALVANIZED AND PRODUCED TO ANSI SPECIFICATION C80.3, FEDERAL SPECIFICATION WW -C-563, AND SHALL BE UL LISTED. EMT SHALL BE MANUFACTURED BY ALLIED, REPUBLIC OR WHEATLAND, OR APPROVED EQUAL. FITTINGS SHALL BE METALLIC COMPRESSION. SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE. r� E. LIQUID TIGHT FLEXIBLE METALLIC CONDUIT SHALL BE USED FOR FINa ("'.OIfNE�,TI(,l,N TO EQUIPMENT. FITTINGS SHALL HE METALLIC GLAND TYPE COMP ESFIO4I eFITTNES, MAINTAINING THE INTEGRITY OF CONDUIT SYSTEM. SET SCREW CONNE'CTPJNS SHALL " NOT BE ACCEPTABLE. MAXIMUM LENGTH ON FLEXIBLE CONDUIT SAALt I$'OT EX,EED ' 6—FEET. LFMC SHALL BE PROTECTED AND SUPPORTED AS REQUIRE BY NEC. MANUFACTURERS OF FLEXIBLE CONDUITS SHALL BE CAROL, ANACONDA METAL HOSE OR UNIVERSAL METAL HOSE, OR APPROVED EQUAL. w F. MINIMUM SIZE CONDUIT SHALL BE 3/4 INCH (21MM). HUBS AND BOXES: " A. AT ENTRANCES TO CABINETS OR OTHER EQUIPMENT NOT HAVING INTEGRAL THREADED HUBS PROVIDE METALLIC THREADED HUBS OF THE SIZE A'f CONFIGURATION REQUIRED. HUB SHALL INCLUDE LOCKNUT AND NEOpR AIE -RING SEAL. PROVIDE IMPACT RESISTANT 105 DEGREE C PLASTIC BUSHINGS' TO PROTECT CABLE INSULATION. e e• n w s e B. CABLE TERMINATION FITTINGS FOR CONDUIT 1. CABLE TERMINATIONS FOR RGS CONDUITS SHALL BE TYPE CRC BY 0—Z/GEDNEY OR EQUAL BY ROX TEC. 2. CABLE TERMINATORS FOR LFMC SHALL BE ETCO — CL2075; OR MADE FOR THE PURPOSE PRODUCTS BY ROXTEC. C. EXTERIOR PULL BOXES AND PULL BOXES IN INTERIOR INDUSTRIAL AREAS SHALL BE PLATED CAST ALLOY, HEAVY DUTY, WEATHERPROOF, DUST PROOF, WITH GASKET, PLATED IRON ALLOY COVER AND STAINLESS STEEL COVER SCREWS, CROUSE—HINDS WAB SERIES OR EQUAL. D. CONDUIT OUTLET BODIES SHALL BE PLATED CAST ALLOY WITH SIMILAR GASKETED COVERS. OUTLET BODIES SHALL BE OF THE CONFIGURATION AND SIZE SUITABLE FOR THE APPLICATION. PROVIDE CROUSE—HINDS FORM 8 OR EQUAL E MANUFACTURER FOR BOXES AND COVERS SHALL BE HOFFMAN, SQUARE "D", CROUSE—HINDS, COOPER, ADALET, APPLETON, 0—Z GEDNEY, RACO, OR APPROVED EQUAL. SUPPLEMENTAL GROUNDING SYSTEM A. FURNISH AND INSTALL A SUPPLEMENTAL GROUNDING SYSTEM TO THE EXTENT INDICATED ON THE DRAWINGS. SUPPORT SYSTEM WITH NON-MAGENTIC STAINLESS STEEL CLIPS WITH RUBBER GROMMETS. GROUNDING CONNECTORS SHALL BE TINNED COPPER WIRE, SIZES AS INDICATED ON THE DRAWINGS. PROVIDE STRANDED OR SOLID BARE OR INSULATED CONDUCTORS EXCEPTED AS OTHERWISE NOTED. B. SUPPLEMENTAL GROUNDING SYSTEM: ALL CONNECTIONS TO BE MADE WITH CAD WELDS, EXCEPT AT EQUIPMENT USE LUGS OR OTHER AVAILABLE GROUNDING MEANS AS REQUIRED BY MANUFACTURER; AT GROUND BARS USE TWO HOLE SPADES WITH NO OX_ C. STOLEN GROUND -BARS: IN THE EVENT OF STOLEN GROUND BARS, CONTACT SPRINT CM FOR REPLACEMENT INSTRUCTION USING THREADED ROD KITS. EXISTING STRUCTURE: A. EXISTING EXPOSED WIRING AND ALL EXPOSED OUTLETS, RECEPTACLES, SWITCHES, DEVICES, BOXES, AND OTHER EQUIPMENT THAT ARE NOT TO BE UTILIZED IN THE COMPLETED PROJECT SHALL BE REMOVED OR DE—ENERGIZED AND CAPPED IN THE WALL, CEILING, OR FLOOR SO THAT THEY ARE CONCEALED AND SAFE. WALL, CEILING, OR FLOOR SHALL BE PATCHED TO MATCH THE ADJACENT CONSTRUCTION, CONDUIT AND CONDUCTOR INSTALLATION: A. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON—PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. B. CONDUCTORS SHALL BE PULLED IN ACCORDANCE WITH ACCEPTED GOOD PRACTICE. `pint .111 SPRINT PARKWAY OVERLAND PARK, KS66251 CROWN CASTLE 1605 WESTLAKE AVE N. SUITE SW 1,= SEATTLE, WA 98109 I PAN MORRISON HERSHFIELD 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tet 206.268.7370 www.morrisonhershiieW.com ���RED A �cti � ROB ERT J. �A L RA Licens # 5897-I • F • �9 2018.12.21 GC= ROBERT JERRY LARA REGISTERED ARCHITECT STATE OF OREGON 5897 MH PROJECT NO.: 7170159 RELEASE NO. DATE D C DESCRIPTION q 06/16/77 BA 907 CD REVIEW B 0270-5/18-7-w-95% CD REVIEW C 04/18/1 JA 98% CD REVIEW D 11/28/18 JA 99% CD REVIEW 0 12/21 18 JA 100% CD FINAL SITE NUMBER P063XCO12 CCI SITE # 879620 SITE NAME EUG173 SITE ADDRESS 333 58TH STREET SPRINGFIELD, OR 97478 SHEET TITLE GENERALNOTES SHEET NO. N-2.0 (S ITE ZONING: LDR I I I I I I I I EXISTING zODRG• I I I I I I I __PERTY LINE (IYPL DRAWING LEGEND X X --- X 4q� SUBJEGi'i'�OFfitTYrIvE i I " s „• ADJACE£dT RCfPERTY-LINE l �� Int EXISTING FENCE 1— 6391 SPRINT PARKWAY OVERLAND PARK, KS68251 DETA16F ,RKEfi* � � �• � CROWN A-2 • • /r • �;,.,► CASTLE X ELEVATION M: RK� 1565 WESTLAKE AVE N, SUITE 809 SEATTLE, WA 96109 X SECTION MARKER* x xx ,NS OPERTY BOUNDARIES AND E OBTAINED FROM I—LINE MAPPING CIMATE. OT DISTURB OR DESTROY TREES ZONING: LDR I EXISTING BUILDING (TYP) STREET L` E N W E S �*_ �"­ 11'n MORRISON HERSHFIELD 600 STEWART ST, SUITE 2DO SEATTLE, WA 98101 Tel: 206.268.7370 w .morrisonhershfieldxom ARC' A/ ROBERT J. ,A W LARA n Licens # 5897 -� • T F • ,9 2018.12.21 o� ROBERT JERRY EARA REGISTERED ARCHITECT STATE OF OREGON 5897 MH PROJECT NO.: 7170159 RELEASE NO. DATE D C DESCRIPTION A 06/16/T7 BA 90% CD REVIEW B 02/05/18 CW 957 CD REVIEW C 04/18/18 JA 98% CD REVIEW D11/28 18 JA 99% CD REVIEW 0 12/27 1B JA 100% CD FINAL SITE NUMBER P063XCO12 CCI SITE # 879620 SITE NAME EUG173 SITE ADDRESS 333 58TH STREET SPRINGFIELD, OR 97478 SHEET TITLE OVERALL SITE PLAN SHEET NO. A-1.0 EXISPRINT MMBS ^"^'""T EXISTING GPS TO MMBS A-4.0 EXISTING SPRINT F [(3) TYPE 2 xrl 1'�` X x x IIS x_- _ X--1 �x , x— W/200A PPC, TELCO CABINET AND 200A METER W/DISCONNECT NOTE• ANTENNAS NOT SHOWN IN PLAN VIEW FOR CLARITY; SEE ELEVATIONS NOTE: NEW CONSTRUCTION WILL NOT DISTURB R,)EZTROY^ r EXISTING LANDSCAPING OR TREES CHAIN LINK FENCE a SPRINT BBU CABINET SPRINT ICE BRIDGE MONOPOLE N W E S Sprint � 6391 SPRINT PARKWAY OVERLAND PARK, KS66261 CROWN �:�CASTLE 1505 WESTLAKE AVE N, SUITE 800 - - SEATTLE, WA 98109 • I PAN MORRISON HERSHFIELD 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tek 206.268.7370 w .mordsonhersh6eldxom RED gRc'� ROBERT J. ',A W LARA � Licens # 5897-{ • F • 2018.12.21 91)5< 0 F () ROBERT JERRY LARA REGISTERED ARCHITECT STATE OF OREGON 6897 MH PROJECT NO.: 7170159 RELEASE NO. DATE D C DESCRIPTION A 06/16 17 BA 90% CD REVIEW g 02 05 18 CW 95% CD REVIEW C 04/18 18 JA 98% CD REVIEW D 11/28/18 JA 99% CD REVIEW O12 21 18 JA 100% CD FINAL SITE NUMBER P063XCO12 CCI SITE # 879620 SITE NAME EUG173 SITE ADDRESS 333 58TH STREET SPRINGFIELD, OR 97478 SHEET TITLE COMPOUND PLAN SHEET NO. A-2.0 MANLIFT REQUIRED NOTES: e w n e e 1. TOWER STRUCTURAL AND ANTENNA MOUNT ANALYSIS TO BE PERFORMED BY OTHERS. SPRINT INSTALLATION SHALL NOT START UNTIL ENGINEER RECEIVES COPY OF APPROVED STRUCTURAL ANALYSIS OR ASSESSMENT 2. CONTRACTOR RESPONSIBLE FOR PROVIDING TOWER RIGGING PLANS, SUBJECT TO OWNER APPROVAL 3. REFER TO STRUCTURAL ANALYSIS FOR APPROVED HYBRID COAX CABLE PLACEMENT 4. COORDINATE WITH CONSTRUCTION MANAGER FOR CURRENT RFDS PRIOR TO CONSTRUCTION 5. COORDINATE FINAL LOCATION OF RRUs WITH CONSTRUCTION MANAGER 6. ALL PROPOSED PANEL ANTENNAS SHALL BE MOUNTED ON NEW 2-7/8" O -D. SCH 40 GALV. PIPE EXISTING SPRINT PANEL ANTENNA T o PROPOSED SPRINT of [RFS APXVSPPI8—C—A20] 0 n PANEL ANTENNA[KMW ETCR-654L12H6] TO BE REMOVED a Q N EXISTING (1) OPTIC FIBER AND EXISTING (1) OPTIC FIBER AND RRH (1) POWER TO REMAIN JUNCTION CYLINDER (1) POWER JUNCTION CYLINDER EXISTING SPRINT [SAMSUNG RRH RR EXISTING SPRINT RRH (TYP OF 3, 1 PER SECTOR) A [SAMSUNG RRH—C4] 3, 1 PER SECTOR) A B PROPOSED SPRINT RRH TO REMAIN B (TYP OF [SAMSUNG RRH-88] (TYP OF 3, 1 PER SECTOR) EXISTING SPRINT RRH [SAMSUNG RRH—P4] (TYP OF 3, 1 PER SECTOR) TO REMAIN EXISTING SPRINT RRH [SAMSUNG RRH—P4] (TYP OF 3, 1 PER SECTOR) EXISTING MONOPOLE FINAL RRH / HYBRID CABLE SCHEDULE FINAL ANTENNA SCHEDULE EXISTING MONOPOLE QTY RRH MODEL RRH FREQUENCY HYBRID CABLE LENGTH HYBRID CABLE TYPE JUMPER SIZE JUMPER LENGTH'. 3 RRH—C4 80OMHz 132'± TYPE 2 1'2" 6' 3 RRH—P4 190OMHz 132'± TYPE 2 1/2" 6' 3 RRH—B8 2500 132'± TYPE 2 1/2" 6' NOTES: e w n e e 1. TOWER STRUCTURAL AND ANTENNA MOUNT ANALYSIS TO BE PERFORMED BY OTHERS. SPRINT INSTALLATION SHALL NOT START UNTIL ENGINEER RECEIVES COPY OF APPROVED STRUCTURAL ANALYSIS OR ASSESSMENT 2. CONTRACTOR RESPONSIBLE FOR PROVIDING TOWER RIGGING PLANS, SUBJECT TO OWNER APPROVAL 3. REFER TO STRUCTURAL ANALYSIS FOR APPROVED HYBRID COAX CABLE PLACEMENT 4. COORDINATE WITH CONSTRUCTION MANAGER FOR CURRENT RFDS PRIOR TO CONSTRUCTION 5. COORDINATE FINAL LOCATION OF RRUs WITH CONSTRUCTION MANAGER 6. ALL PROPOSED PANEL ANTENNAS SHALL BE MOUNTED ON NEW 2-7/8" O -D. SCH 40 GALV. PIPE EXISTING SPRINT PANEL ANTENNA T o PROPOSED SPRINT of [RFS APXVSPPI8—C—A20] 0 n PANEL ANTENNA[KMW ETCR-654L12H6] TO BE REMOVED a Q N EXISTING (1) OPTIC FIBER AND EXISTING (1) OPTIC FIBER AND RRH (1) POWER TO REMAIN JUNCTION CYLINDER (1) POWER JUNCTION CYLINDER EXISTING SPRINT [SAMSUNG RRH RR EXISTING SPRINT RRH (TYP OF 3, 1 PER SECTOR) A [SAMSUNG RRH—C4] 3, 1 PER SECTOR) A B PROPOSED SPRINT RRH TO REMAIN B (TYP OF [SAMSUNG RRH-88] (TYP OF 3, 1 PER SECTOR) EXISTING SPRINT RRH [SAMSUNG RRH—P4] (TYP OF 3, 1 PER SECTOR) TO REMAIN EXISTING SPRINT RRH [SAMSUNG RRH—P4] (TYP OF 3, 1 PER SECTOR) EXISTING MONOPOLE EXISTING SPRINT ANTENNA MOUNT FINAL ANTENNA SCHEDULE EXISTING MONOPOLE ' ` " • SECTOR ANTENNA FREQUENCY ANTENNA MFR ANTENNA MODEL ANTENNA QTY AZIMUTH RAD CENTER ANTENNA LENGTH MECH' TILT -ELECT TILT ALPHA 800/1900/2500 MHz KMW ETCR-654L12146 1 0' 82.0' 84.9" 0' 2' BETA 800/1900/2500 MHz KMW ETCR-6541_12H6 1 105' 82.0' 84.9" 0' . •1' GAMMA 800/1900/2500 MHz KMW ETCR-654L12H6 1 240' 82.0' 84.9" 0'" •3' NOTES: e w n e e 1. TOWER STRUCTURAL AND ANTENNA MOUNT ANALYSIS TO BE PERFORMED BY OTHERS. SPRINT INSTALLATION SHALL NOT START UNTIL ENGINEER RECEIVES COPY OF APPROVED STRUCTURAL ANALYSIS OR ASSESSMENT 2. CONTRACTOR RESPONSIBLE FOR PROVIDING TOWER RIGGING PLANS, SUBJECT TO OWNER APPROVAL 3. REFER TO STRUCTURAL ANALYSIS FOR APPROVED HYBRID COAX CABLE PLACEMENT 4. COORDINATE WITH CONSTRUCTION MANAGER FOR CURRENT RFDS PRIOR TO CONSTRUCTION 5. COORDINATE FINAL LOCATION OF RRUs WITH CONSTRUCTION MANAGER 6. ALL PROPOSED PANEL ANTENNAS SHALL BE MOUNTED ON NEW 2-7/8" O -D. SCH 40 GALV. PIPE EXISTING SPRINT PANEL ANTENNA T o PROPOSED SPRINT of [RFS APXVSPPI8—C—A20] 0 n PANEL ANTENNA[KMW ETCR-654L12H6] TO BE REMOVED a Q N EXISTING (1) OPTIC FIBER AND EXISTING (1) OPTIC FIBER AND RRH (1) POWER TO REMAIN JUNCTION CYLINDER (1) POWER JUNCTION CYLINDER EXISTING SPRINT [SAMSUNG RRH RR EXISTING SPRINT RRH (TYP OF 3, 1 PER SECTOR) A [SAMSUNG RRH—C4] 3, 1 PER SECTOR) A B PROPOSED SPRINT RRH TO REMAIN B (TYP OF [SAMSUNG RRH-88] (TYP OF 3, 1 PER SECTOR) EXISTING SPRINT RRH [SAMSUNG RRH—P4] (TYP OF 3, 1 PER SECTOR) TO REMAIN EXISTING SPRINT RRH [SAMSUNG RRH—P4] (TYP OF 3, 1 PER SECTOR) EXISTING ANTENNA CONFIGURATION SCALE: 1/2"=1'-0" (22x34 (OR) 1/4"=1'-0" (1107)) 2 I FINAL ANTENNA CONFIGURATION N W E S SCALE 1/2"=1'-0" (22x34) (OR) 1/4"=1'-0" (t 1x17) pprint I' 6391 SPRINT PARKWAY OVERLAND PARK, KSBW51 I • CROWN CASTLE 1565 WESTLAKE AVE N, SATE WO SEATTLE. WA 991* tee" soW MORRISON HERSHF'IELD 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tet 206.268.7370 www.morrisonhershfield.com ���RED ARc'yi ROBERT J. W LARA Licens # 5897- • T F • 2018.12.21 �O= 9� 9. 7 b ROBERT JERRY IARA REGISTERED ARCHITECT STATE OF OREGON 5897 MH PROJECT NO.: 7170159 RELEASE NO. DATE I D C DESCRIPTION A 06/16/171 BA 90% CD REVIEW _L 02/05/1 CW 95% CD REVIEW C 04/18/18 JA 98% CD REVIEW D 11/28/18 JA 99% CD REVIEW 0 12721,71-8 JA 100% CD FINAL SITE NUMBER P063XCO12 CCI SITE # 879620 SITE NAME EUG173 SITE ADDRESS 333 58TH STREET SPRINGFIELD, OR 97478 SHEET TITLE ANTENNA CONFIGURATIONS SHEET NO. A-3.0 EXISTING MONOPOLE EXISTING SPRINT ANTENNA MOUNT EXISTING MONOPOLE EXISTING SPRINT ANTENNA MOUNT EXISTING (1) OPTIC FIBER AND EXISTING (1) OPTIC (1) POWER JUNCTION CYLINDER [TO FIBER AND (1) POWER -5F REMAIN F JUNCTION CYLINDER E PROPOSED SPRINT SfC 7 -OR C PANEL ANTENNA E C 2� EXISTING SPRINT[KMW PANEL SEC ETCR-654L12H6] �'• ANTENNA [RFS APXVSPP18—C—A201 EXISTING (1) OPTIC FIBER AND �T�OR 2� 10'� D 5' OR S�G� 2h0 EXISTING (1) OPTIC PROPOSED SPRINT TO BE REMOVED (1) POWER JUNCTION CYLINDER ' FIBER AND (1) POWER PANEL ANTENNA TO REMAIN Pti JUNCTION CYLINDER D [KMW ETCR-654L12H6] EXISTING SPRINT PANEL ANTENNA [RFS APXVSPPI8—C—A201 TO BE REMOVED EXISTING ANTENNA CONFIGURATION SCALE: 1/2"=1'-0" (22x34 (OR) 1/4"=1'-0" (1107)) 2 I FINAL ANTENNA CONFIGURATION N W E S SCALE 1/2"=1'-0" (22x34) (OR) 1/4"=1'-0" (t 1x17) pprint I' 6391 SPRINT PARKWAY OVERLAND PARK, KSBW51 I • CROWN CASTLE 1565 WESTLAKE AVE N, SATE WO SEATTLE. WA 991* tee" soW MORRISON HERSHF'IELD 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tet 206.268.7370 www.morrisonhershfield.com ���RED ARc'yi ROBERT J. W LARA Licens # 5897- • T F • 2018.12.21 �O= 9� 9. 7 b ROBERT JERRY IARA REGISTERED ARCHITECT STATE OF OREGON 5897 MH PROJECT NO.: 7170159 RELEASE NO. DATE I D C DESCRIPTION A 06/16/171 BA 90% CD REVIEW _L 02/05/1 CW 95% CD REVIEW C 04/18/18 JA 98% CD REVIEW D 11/28/18 JA 99% CD REVIEW 0 12721,71-8 JA 100% CD FINAL SITE NUMBER P063XCO12 CCI SITE # 879620 SITE NAME EUG173 SITE ADDRESS 333 58TH STREET SPRINGFIELD, OR 97478 SHEET TITLE ANTENNA CONFIGURATIONS SHEET NO. A-3.0 TOP OF EXISTING MONOPOLE ±85'-0" AGL RAD CENTER OF EXISTING SPRINT ANTENNAS ±82'—O- AGL EXISTING SPRINT ANTENNA MOUNT STRUCTURAL MONOPOLE REINFORCEMENT f45'-0" AGL STRUCTURAL MONOPOLE REINFORCEMENT ±25'-0 AGL EXISTING SPRINT ICE BRIDGE EXISTING SPRINT MMBS CABINET EXISTING CHAIN LINK FENCE RADE 4 ASSOMED 0'-0" AGL EXISTING WEST ELEVATION MANL1Ff REQUIRED VEXISTING SPRINT PANEL ANTENNA r-(TYP OF 3, 1 PER SECTOR) I I TO BE REMOVED EXISTING SPRINT RRH (TYP OF 6, 2 PER SECTOR) TO REMAIN EXISTING MONOPOLE EXISTING MONOPOLE STRUCTURAL REINFORCEMENT MODIFICATION EXISTING SPRINT FEEDLINES [(3) TYPE 2 HYBRID] INSTALLED WITHIN MONOPOLE EXISTING MONOPOLE STRUCTURAL REINFORCEMENT MODIFICATION EXISTING MONOPOLE STRUCTURAL REINFORCEMENT MODIFICATION EXISTING SPRINT UTILITY H—FRAME W/200A PPC, TELCO CABINET AND 200A METER W/DISCONNECT STRUCTURAL REINFORCEMENT ±5'-0" AGL PROPOSED SPRINT RRH (TYP OF 3, 1 PER SECTOR) P OF EXISTING MONOPOLE ±8Y 5'-0" AGL RAD CENTER OF EXISTING AND Ak��PR��OPOSED SPRINT ANTENNAS "182 =0' AGL EXISTING SPRINT ANTENNA MOUNT NOTE: NO WORK SHALL COMMENCE WITHOUT THE APPROVED TOWER/ANTENNA MOUNT STRUCTURAL ANALYSIS REPORT SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER UNDER SEPARATE COVER. IF REQUIRED, THE CONTRACTOR SHALL MODIFY ANTENNA MOUNTS AS INDICATED IN THE ABOVE MENTIONED STRUCTURAL REPORT OR ASSOCIATED MODIFICATION DESIGN DRAWINGS. STRUCTURAL REINFORCEMENT Y ±45'—D" AGL STRUCTURAL REINFORCEMENT Y±25'-0" AGL EXISTING SPRINT ICE BRIDGE EXISTING SPRINT MMBS CABINET EXISTING CHAIN LINK FENCE GRADE ASSUMED 0'-0- AGL 2 I PROPOSED WEST ELEVATION PROPOSED SPRINT PANEL ANTENNA (TYP OF 3, 1 PER SECTOR) EXISTING SPRINT RRH' (TYP OF 6, 2 PER SECTOR) EXISTING MONOPOLE EXISTING MONOPOLE STRUCTURAL REINFORCEMENT MODIFICATION EXISTING SPRINT FEEDLINES [(3) TYPE 2 HYBRID] INSTALLED WITHIN MONOPOLE EXISTING MONOPOLE STRUCTURAL REINFORCEMENT MODIFICATION EXISTING MONOPOLE STRUCTURAL REINFORCEMENT MODIFICATION EXISTING SPRINT UTILITY H—FRAME W/200A PPC, TELCO CABINET AND 200A METER W/DISCONNECT STRUCTURAL REINFORCEMENT ±5'-0" AGL (OR) 3/32"=1'-O" (11x17) w •sprint 6391 SPRINT PARKWAY OVERLAND PARK, KS66251 - _ : CROWN ,Z✓ CASTLE 1565 WESTLAKE AVE N, SATE 806 SEATTLE, WA 98109 MORRISON HERSHFIELD 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 www.mordsonhershfield.com ARC ti ROB ERT J. cu LARA n Licens • A T ^,F L '9 2018.12.21 GO`' OF ROBERT JERRY LARA REGISTERED ARCHITECT STATE OF OREGON 6897 MH PROJECT NO.: 7170159 RELEASE NO. DATE _VC DESCRIPTION A 06/16/17 BA 90% CD REVIEW B 02/05/16 cW 95% CD REVIEW C 04/18/18 JA 987 CD REVIEW D 11/28/18 JA 99% CD REVIEW 012 21 18 JA 1007 CD FINAL SITE NUMBER P063XCO12 GCI SITE # 879620 SITE NAME EUG173 CITE AnrkDPCC 'I, I" OttfH JIKttl SPRINGFIELD, OR 97478 SHEET TITLE WEST ELEVATIONS SHEET NO. A-4.0 1 m m FRONT SIDE I SCALE N.Ts. % NOT USED SN—' LE s ANTENNA SPECIFICATIONS scALE $ NOT USED N.T.S. N.T.S. NOTE: ANTENNA PIPES NOT TO EXCEED 8 FT OR EXTEND OUTSIDE OF CARRIER'S VERTICAL LEASE AREA ANTENNA DOWNTILT KIT, AS REQ'D ANTENNA MOUNTING PIPE 2.5 INSTALLATION REQUIRES 2-7/8" O.D_ANTENNA PIPE MOUNTING BRACKET PROVIDED BY MFR (TYP) RRH PER PLAN; MOUNTING ` HARDWARE PROVIDED BY MFR; INSTALL PER MFR RECOMMENDATIONS TYP MOUNTING DETAIL PANEL ANTENNA 4 1 NOT USED N.Tsc 3 1 NOT USED SCALE N.T.S. MANUFACTURER: SAMSUNG MODEL:RRH-B8 WEIGHT: 59.5 LBS DIMENSIONS: 22.98" x 15.04" x 9.09" FREQUENCY: REFER TO RF DATA SHEET NOTE: INSTALL PER MFR RECOMMENDATIONS MANUFACTURER: KMW MODEL: ETCR-654L121'r6 • w NO. DATE WEIGHT: 84.9 LBS DESCRIPTION DIMENSIONS: 84.9" x �i1.�t" �� 6.3' s� FREQUENCY: REFER TO RF DATA SHEET T Cw 21.0' I JJJ��� • TOP 77 7 - D 11/28/18 6.3" 21.0" RRH SPECIFICATIONS SCALE N.T.S. F n m m FRONT SIDE I SCALE N.Ts. % NOT USED SN—' LE s ANTENNA SPECIFICATIONS scALE $ NOT USED N.T.S. N.T.S. NOTE: ANTENNA PIPES NOT TO EXCEED 8 FT OR EXTEND OUTSIDE OF CARRIER'S VERTICAL LEASE AREA ANTENNA DOWNTILT KIT, AS REQ'D ANTENNA MOUNTING PIPE 2.5 INSTALLATION REQUIRES 2-7/8" O.D_ANTENNA PIPE MOUNTING BRACKET PROVIDED BY MFR (TYP) RRH PER PLAN; MOUNTING ` HARDWARE PROVIDED BY MFR; INSTALL PER MFR RECOMMENDATIONS TYP MOUNTING DETAIL PANEL ANTENNA 4 1 NOT USED N.Tsc 3 1 NOT USED SCALE N.T.S. MANUFACTURER: SAMSUNG MODEL:RRH-B8 WEIGHT: 59.5 LBS DIMENSIONS: 22.98" x 15.04" x 9.09" FREQUENCY: REFER TO RF DATA SHEET NOTE: INSTALL PER MFR RECOMMENDATIONS w N S10-flnf Vw 8391 SPRINT PARKNAY OVERLAND PARK, KS66251 w w � CROWN o,,,,r CASTLE 1505 WESTLAKE AVE N, SUITE 600 SEATTLE, WA 90100 ww r MORRISON HERSHFIELD 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tel; 206.266.7370 www.morrisonhershfield.com ��RV,D ARC ti l ROB ERT J. W LARA Licens # 5997 -1 • ANT ON, F • 01 .21 00 q'AOF_6� ROBERT JERRY LARA REGISTERED ARCHITECT STATE OF OREGON 5897 MH PROJECT NO.: 15.04" LEA -E NO. DATE PLAN DESCRIPTION 1.5.04" BA 90% CD REVIEW B 02/05 t8 Cw 95% CD REVIEW m I I N JA 77 7 - D 11/28/18 FRONT RIGHT Q RRH SPECIFICATIONS SCALE N.T.S. w N S10-flnf Vw 8391 SPRINT PARKNAY OVERLAND PARK, KS66251 w w � CROWN o,,,,r CASTLE 1505 WESTLAKE AVE N, SUITE 600 SEATTLE, WA 90100 ww r MORRISON HERSHFIELD 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tel; 206.266.7370 www.morrisonhershfield.com ��RV,D ARC ti l ROB ERT J. W LARA Licens # 5997 -1 • ANT ON, F • 01 .21 00 q'AOF_6� ROBERT JERRY LARA REGISTERED ARCHITECT STATE OF OREGON 5897 MH PROJECT NO.: 7170159 LEA -E NO. DATE D C DESCRIPTION A 06/16/17 BA 90% CD REVIEW B 02/05 t8 Cw 95% CD REVIEW C 04/18/18 JA 987 CD REVIEW D 11/28/18 JA 99% CD REVIEW 012 21 18 JA 100% CD FINAL SITE NUMBER P063XCO12 CCI SITE # 879620 SITE NAME EUG173 SITE ADDRESS 333 58TH STREET SPRINGFIELD, OR 97478 SHEET TITLE CONSTRUCTION DETAILS SHEET NO. A-5.0 1 EXISTING GROUND BAR 3/8" WASHER 3/8" SS LOC '�— 3/8" SS NUT SOLID BARED TINNED COPPER CONDUCTOR W/ THERMOWELD 3/8"0/4" SS BOLT 3/8" WASHER TYPICAL GROUND BAR CONNECTION DETAIL � 4 N.T.S. 2 HOLE LUG 1/4-20 HEX BOLT #2 AWG GRN �1/4" FLAT WASHER _77_777 77 41 PRIMARY GROUND BAR/ METAL ENCLOSURE EXT. TOOTH LOCK WASHER =--�1/4-20 HEX NUT INSTALLATION_ NOTES: 1. SELECT BOLT LENGTH TO PROVIDE A MINIMUM OF TWO EXPOSED THREADS. 2. BURNISH MOUNTING SURFACE TO REMOVE PAINT IN THE AREA OF LUG CONTACT. 3. APPLY ANTI—OXIDANT COMPOUND TO MATING SURFACE OF LUG AND WIPE CLEAN EXCESS COMPOUND. 4. USE SOLID COPPER WIRE AND MECHANICAL 2—HOLE LUG FOR ALL EXTERIOR GROUNDING. GROUND CONNECTION DETAILS`� i 3 ^ X (TYPICALLY) N ¢ 12" TO 24' ANTENNA CABLE 120" MAX. WEATHERPROOFING KIT (SEE NOTE 3) CABLE CONNECTOR CABLE GROUND KIT #6 AWG STRANDED COPPER GROUND WIRE (BONDED TO GROUND BAR); SEE NOTE 1 & 2 NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. CABLE GROUND KIT CONNECTION N.T.S. PROPOSED RRH I #2 AWG SOLID BARE TINNED I I COPPER CONDUCTOR #2 AWG STRANDED UV RATED JACKETED COPPER CONDUCTOR / I / f °°OOO°0°e8°0o EXISTING ANTENNA SECTOR GROUND BAR, GROUNDED TO TOWER 2 I EQUIPMENT GROUNDING PLAN • •� • 2-7/8" 0_D. ANTENICA MOUNTING PIPE r•• PROPOSED PANEL ANTENNA F 11� • -Sprint 6391 SPRINT PARKWAY OVERLAND PARK, KS66251 • •I• r� 'CROWN CASTLE I 1505 WESTLAKE AVE N, SUITE 800 • �` SEATTLE, WA 98109 F• mri MORRISON HERSHFIELD 600 STEWART ST, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 www.mordsonh ershfield.00m Aj?Cj 61 ROB ERT J. LARA 0 Licens # 5897 _4 • F • 2018.12.21 11 8:42-0 �O ROBERT JERRY LARA REGISTERED ARCHITECT STATE OFOREGON 5897 MH PROJECT NO.: 7170159 RELEASE NO. DATE D C DESCRIPTION A 06/16/17 BA 90% CD REVIEW B 02/05 18 CW 95% CD REVIEW C 04/18/18 JA 98% CD REVIEW D 11/28/18 JA 997.CD REVIEW 012 21 18 JA 100% CD FINAL SITE NUMBER P063XCO12 CCI SITE # 879620 SITE NAME EUG173 SITE ADDRESS 333 58TH STREET SPRINGFIELD, OR 97478 SHEET TITLE GROUNDING DETAILS SHEET NO. E-1.0 SCALE N.T.S.