Loading...
HomeMy WebLinkAboutPermit Building 2019-01-070,1i$0il Web Address: www.springfield or.qov Building Permit Residential 'l & 2 Fam Dwelling (New Only) Permit Number: 81 'l -18-002782-DWL IVR Number: 81'1 061491 61 I City of Springfield Development and Public Works 225 Fifth Street Sprinqfield, OR 97477 54t-726-3753 Email Address: permitcenter@springfield or.gov SPrtlNGf liLD Permit lssued: January 07, 20'19 Category of Construction: Single Family Dwelling Submitted Job Value: $239.249.20 Description of Work: New SFD Lot 39 River Heights Type of Work: New Worksite address 3583 VITUS LN Springfeld, OR 97477 Parcel 1702301203400 Owner: Address: BREEDEN BROS INC 366 E 4OTH AVE STE 250 EUGENE, OR 97405 Business name BREEDEN BROS INC - Primary License UUtJ License number 27 Phone 541-686-9431 Permits must be posted in clear vi6w on the worksite. Permits expire if work is not startsd within '180 Days of issuance or iI work is suspend€d for 180 Days or longo. dqp€nding on the issuing agency's policy. All provisions of la\.6 and ordinances governing this typ€ o{ work will be compligd with whether specified h€rsin ornot Granting of a permit does not presume to giv€ authority to violate or cancol the paovisions of any othea state or local law regulating construction or tho performance of construction. ATTENTION - CALL BEFORE YOU DIG: Oregon law requires you to follow rules adopted by the Oregon utility Notification Center. Thoso rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain copies of the rul6s by calling the cente. at (877) 6684001 or dial 811. All persons or ontities peforming work under this permit are rsquired to be liconsod unless exempted by ORS 701.010 (Structural/Mochanical), ORS /u9.540 (Electrical), and ORS 693.010420 (Plumbing). Pflnted on 1rl19 Page 1 ol5 std_BuildingPennrt-pr TYPE OF WORK JOB SITE INFORMATION PENDING INSPECTIONS Permit Number: 81 1 -1 8-002782-DWL lnspection 2999 Final Mechanical '1 530 Exterior SheaMall 1260 Framing 2999 Final Mechanical 2300 Rough Mechanical 4999 Final Eleclrical 4500 Rough Eleclrical 1090 Street Trees 1'110 Footing 1118 Footing Drain 1120 Foundation 1160 UFER Ground 1220 Underfloor framing '1 370 Masonry Veneer 1460 lnsulation 1520 lnterior SheaMall 1999 Final Building 2200 Underff oor Mechanical 2210 Underfloor Gas 2255 Gas Pressure Test 2310 Rough Gas 2995 Final Gas 31 30 Footing/Foundation Drains 3200 Sanitary Sewer 3315 Water Line 3400 Storm Sewer 3500 Rough Plumbing 3999 Final Plumbing 4000 Temporary Power Service 4225 Service or Feeder 1 060 Driveway Approach 1065 Sidewalk 1 020 Zoning/setbacks 1420 lnsulation Vapor Barrier 1430 lnsulation Wall Pdnted on: 1rl19 Page 2 of 5 lnspection status Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending Pending std_BuildingPermitjrPage 2 of 5 lnspection group 1 2 Famdwell 1-2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell '1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 'l_2 Famdwell 1_2 Famdwell 1_2 Famdwell 'l_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1-2 Famdwell 1_2 Famdwell 1_2 Famdwell 1_2 Famdwell 1 2 Famdwell Permit Number: 8l 1.1 8-002782-DWL 1440 lnsulation Ceiling 3170 Underfl oor Plumbing '1_2 Famdwell 1_2 Famdwell Page 3 of 5 Pending Pending Various inspeclions are minimally required on each projecl and often dependenl on the scope ofwork. Conlact the issuing jurisdiclion indic€ted on the permit to determine required inspections for this project. Schedule or track inspections at www.buildingpermits.oregon.gov Schedule by phone call 1-888-299-2821 use IVR number: 811061491618 Schedule using the Oregon ePermitting lnspection App, search "epermitting' in the app store Page 3 of 5 std_EuiidingPermit_pr SCHEDULING INSPECTIONS Printed onr 1,7/T9 Permit Number: 81 1 -l 8-002782-DWL Page 4 of 5 Fee Description Residential wiring Technology Fee Clothes dryer exhaust Decorative gas flreplace Furnace - up to 100,000 BTU Heat pump Range hood/other kitchen equipment Ventilation fan connected to single duct Water heater Plan Review - Major, City Single Family Residence - Baths Address assignment - each new or change requested externally, per each SDC: Improvement Cost - Local Wastewater SDC: Total MWMC Administration Fee - Local SDC: Total Transportation Administration Fee SDC: Total Sewer Administration Fee SDC: Total Storm Administration Fee SDC: Administrative Fee - l4wluc Regional Wastewater SDC SDC: MWl"lC Credit - Regional Wastewater SDC SDC: Compliance Cost - MWMC Regional Wastewater SDC SDC: Improvement Cost - lvlwt'lc Regional Wastewater SDC SDC: Reimbursement Cost - MWMC Regional Wastewater SDC SDCr Improvement - Transportation SDC SDC: Reimbursement Cost - Storm Drainage SDC: Improvement Cost - Storm Drainage SDC: Reimbursement Cost - Local Wastewater SDC: Reimbursement - Transportation SDC Fire SDC - New Res Construction Sq Ft fee - enter sq ftg Structural plan review fee Structural building permit fee Willamalane fees - Single Family Detached, per unit State of Oregon Surcharge - i4ech (12olo of applicable fees) State of Oregon Surcharge - Elec (12olo of applicable fees) State of Oregon Surcharge - Plumb (12% of applicable fees) State of Oregon Surcharge - Bldg (12o/o of applicable fees) Curb cut fee - enter # of cuts Curb cut and Sidewalk construction - multiple permit discount Sidewalk construction - permit, first 90 linear feet 1 1 1 1 1 3 1 1 3 1 1630.8 86.39 184.55 247 .08 82.03 10 -34.31 22.82 t597 .44 131.89 3506.54 67t.79 968.84 3310.8 184.51 2318 Quantity 2 318 Fee Amount $286.00 $ 215.83 $ 13.00 $ 18.00 $22.O0 $22.00 $ 18.00 $39.00 $ 18.00 $244.00 $ 595.00 $s2.00 $ 1,630.80 $86.39 $ 184.55 $247.08 $82.03 $ 10.00 $-34.31 $22.82 $1,,597.44 $ 131.89 $3,506.54 $671.79 $968.84 $3,310.80 $ 184.51 $ 139.08 $1,098.54 $ 1,690.06 $3,727.OO $ 18.00 $34.32 $71.40 $202.81 $ 121.00 $-41_ 00 $ 121 .00 1 1 1 1 Printed on: 1/7/19 Page 4 of 5 std_EuildingPennit_pr PERMTT FEES Permit Number: 81 1 -'l 8-002782-DwL Total Fees: Page 5 of 5 $2t,32O.21 Construction type Occupancy type R-3 1 & 2 family U Utility, misc. U Utility, misc. - half rate Unit amount 1,834.00 437.00 47.OO Unit Unit cost $1 18.45 $47.80 $23.90 Job value $217 ,237.30 $20,888.60 $1,123.30 $239.249.2O VB VB VB Sq Ft Sq Ft Sq Ft Totaljob value: Printed on 1,7/19 Page 5 of 5 std_BuildingPermit_pr VALUATION INFORMATION SPITINGFIELD 0 rtEGON www.springfi eld-or. gov Worksite address: 3583 VITUS LN, Springfield, OR97477 Parcel: 1702301203400 Transaction Receipt 811-18-002782-DWL Receipt Number: 469025 Receipt Date: 1/7/19 City of Springfield Transaction date Units1n119 1.00 Ea 1t7t19 2,3'18.00 SqFt 117119 3.00 Qty 1l7l't9 1.00 Ea lnhg 1.00 Ea 1n119 1.00 Ea 1nh9 '1.00 Ea 1t7119 1.00 Ea ln4g 3.00 Ea 1t7t19 1.00 Ea 1t7t19 1.00 Ea Description Structural building permit fee Residenlial wiring Single Family Residence - Baths Furnace - up to 100,000 BTU Heat pump Decoralive gas flreplace Water heater Range hood/other kitchen equipment Ventilation lan connected to srngle duct Clolhes dryer exhausl State of Oregon Surcharge - Elec (12o/o ol applicable fees) State of Oregon Surcharge - Mech (12% of applcable fees) Stale of Oregon Surcharge - Plumb ('12% of apphcable fees) State of Oregon Surcharge - Bldg (12% of applicable fees) Account code 224 - OOOOO - 425602- 1 030 224-00000426102-1033 224-00000-425603 103/. 224-00000-425604-1 031 224-00000425604-1031 22 4 -OOOOO - 425604 - 1 03 1 22 4-OOOOO - 42 5604- 1 03 1 224 - OOO00- 425604- 1 03 1 224,00000425604- 1031 22 4 -OOOOO - 42560 4 - 1 03 1 82'l 00000-2'15004-0000 117119 1t7 t19 1.00 Ea 1.00 Ea Fees Paid Fee amount $1,690.06 $286.00 $595.00 $22.00 $22.00 $'18.00 sle oo s18.00 ssg oo $13.00 sat.sz Paid amount $1,690.06 $286.00 $595.00 $22.OO $22.00 $18.00 $18.00 $18.00 $39.00 $'13.00 $34 32 82 1 -00000-2 1 5004-0000 821-00000-21 5004,0000 $18.00 $71.40 $18.00 $71.40 $2O2.81 Printed: 1/7/19 8 41 am 1.00 Ea Page I of 3 821 00000 215004-0000 $202.81 Fl N TransactionReceipt_pr Development and Publlc Works 225 Fifth Street Springfield, OR 97477 54 L-7 26-37 53 permitcenter@springfield-or.gov 117t19 Transaction Receipt 8'11-18-002782-DWL Receipt number: 469025 Transaction date Units 117119 671.79 Amount 117119 968.84 Amount 117119 3,310.80 Amount Description SDC: Reimbursement Cost - Slorm Drainage SDC: lmprovement Cost - Storm Drainage Account code 61 7-00000-448029-8800 61 7-00000-448028-8800 61 1-00000448024-8800 61 1 -00000-448025-8800 434-00000-448026-8800 434-00000-448027-8800 433-00000-448024-881 0 Fees Paid SDC: Reimbursement Cost - Local Wastewaler Fee amount $67'1.79 $968.84 $3,310.80 $1,630.80 $184.51 $3,506.54 $131 .89 $1.597.44 $22.82 $(34.31) $10.00 $82.03 $247 .Oa $184.55 $86.39 Paid amount $671.79 $968.84 $3,310.80 $1,630.80 $184.51 $3,506.54 $'131 .89 $1,597.44 $22.82 $(34.31) $ 10.00 $82.03 $247.08 $184.55 $86.39 $121.00 'v7119 'lt7l'19 1l7l'19 1nl1s 1,630.80 Amount 184.51 Amount 3,506.54 Amount 131.89 Amount SDC: lmprovemenl Cost - Local Wastewater SDC: Reimbursement - Transportation SDC SDC: lmprovement - Transpo(ation SDC SDC: Reimbursement Cost - M\ ArC Regional Wastewater SDC SDC: lmprovement Cost - MWVIC Regional Wastewater SDC 433-00000-448025-881 0 433-00000-426607-BB1 0 433-00000-448025-BB 1 0 611-00000 426604 8800 1t7119 1t7 t'ts 1t7 t19 1t7119 117119 1t7t19 1t7 t19 1n 119 82.03 Amounl 247.08 Amount 184.55 Amount 86.39 Amount 71 9-00000-426604-8800 71 9-00000-426604-8800 7'l 9-00000-426604-8800 71 9-00000-426604-8800 '1,597.44 Amount 22.82 Amounl SDC: Compliance Cost - N4WMC Regional Wastewater SDC 34.31 Amount SDC: MWMC Credit - Regional Waslewaler SDC 10.00 Amount SDC: Administrative Fee - MWMC Regional Wastewater SDC SDC: Total Slorm Administration Fee SDC: Total Sewer Administration Fee SDC: Total Transportation Administration Fee SDC: Total MWMC Administration Fee - Local Curb cut fee - enter # of cuts Printed: 1/7/19 8.41 am 1.00 Qty Page 2 of 3 201-00000 428060-1069 $121.00 FIN_TransaclionReceipt_pr 1t7 t19 Transaction date 117 t19 Units 1.00 Ea 117119 1t7 t19 Description Curb cut and Sidewalk construction - multiple permit discount Sidewalk construction - permit, first 90 linear feet Plan Review - Major, City Address assignment - each new or change requested externally, per each Technology Fee Wllamalane fees - Single Family Detached, per unit Fire SDC - New Res Construclion Sq Ft fee - enter sq ftg Account code 20'1 -00000-428060- 1 069 Fees Paid 1.00 Ea 1 .00 Aulomatic 1 .00 Oty 2,318.00 SqFt 201-00000-428060-1069 100-00000 424005 1091 Fee amount $(41.00) $121.00 $2,14.00 s52.00 $21s.83 $3,721.00 $139.08 Paid amount $(41.00) $244.O0 $52.00 $215.83 $3,72'1.00 $139.08 117t19 1t7l1S 1.00 Ea 1 .00 Ea 1l7l't9 117t19 1 0G.00000-425002- 1 039 224-00000-425602-0000 1 00-00000-425605-0000 82 1 -00000-2 1 5023-0000 Payment Method Payment Method Credit card authorization 06916m Check number: 211 Payer:john thompson Payer: john thompson Payment Amount: Payment Amount: $9,500.00 $10,721.67 Cashier: Kalrina Anderson Receipt Total:$20,22'1.67 Page 3 of 3 FIN_TransactionReceiptjr Transaction Receipt 811-18-002782-DWL Receipt number: 469025 $12'1 .00 Printed: 1fll19 8 41 am Structural Permit Application 225 Fifth Strccr. Sprinsficl4 OR 9717i I pH(541I26-375J . FAX54l)2e3589 This pelmit i$ issued untler OAR 918-460-0030. Peruils cxpire if nork is rot slarted ]yithio 180 da,s suspended for 180 days. LOCAL GOVERNIVIENT APPROVAL This projecr has final land-use appfoyai Signstu.c:Dalei This pmject tras DEQ approvat Signature:Datc: Zoaing approval verified: I Yes E No Propety is *'ilhin flood plain: I Yx t] No CATEGORY OF CONSTRUCTION d Residdtial n Goversrneqt n Connrercial JOB SITE INFORMATION AND LOCATION Jobsit address: 3593 VrrqS city:€P|"INC,FIELF\State: O R,z\P.11tT7 Sutdivision: €,1 UeR- HetC HT S Lotno.: -JQ Referencti t1-62-- e6- \ L Ta{oti 3J0O PROPERTY OWNER Naoe: 6ZEF1)E\1 Hor.JFS Address: jA6 E 4OIh AVE. S-f E 25o c;ry: EUGeNE Srate: OR zIP:911:t Plo|e:EAl-l,fu 9431 la.)r E-mail T}IS instalIatio rs benrg OD tial fann propeAy me or a meurber ofoy irDmediate fumity, and is exenrpr fiom licensiDg pquirements tnder ORS 701.010. Sign here: CONTRACTOR INSTALLATION Business name: S*fqa AS A R$V E Address: City:STdE Phone:Fax E-mail Js!+N o gfEgDEil r.lo^,tE. CpM CCB lice*e no.: B-f Print name:Jo g ^.1 THoMpsDJ I SUB.CONTRACTOR INFORMATION NamE / CCB Licensc Number Phorr Ntlmber trlcctricrrl ltl;1zc 153'oozn Plumhing lg I6rs zot- ?5 lf{cchsJrical '7 {.1qo 141- 1145 $&#fuic lssua11 or if work is - Tr+oa r.:'ror.{ - L: i. t,u_.rr.6lrJ - l1A Ps *ft LLF 1 DEPARTMENT USE ONLY y",nit,...ffi/S/tr-2, oate:///'Jo/tf, FEE SGHEDULE 1. Valuation inforEation (a) Job de scription: 5.I IOK B.J I LT S I rJ q LE FAd rr-f Occupascy ConstructioD type: i4O oD Fe,4 A4 € square lE€r l8J{=rr\Jr".s _ 432, Qaa- 47. Corr. t Cost per Equare foot Otlcr iaformation: Typr orfl.at qA5 rew I alteration E addition Encrgl Palhr !J (b) Foundarior-only pcroit? E y"s E Uo Tol:rl Yilualion: 2. Brildirg fees s l /"gn(a) Permit fee (use yalualion hble) (b) Investigative fee (equal to [2a):$ (c) Reinspectioo (3 per [our):(numberofbous r fc-e per bour)$ 5(d) Enler l2% surcharg a (.12 x L2a+zbtTc\:) (e) Subtotal of fee.r above (2athrongh 2d)l 5 sl bcjll(a) Plan revierv (65% x pemitfe€ [2a]) (b) Firc and life safeo (40?'o x pcmit fcc [24]):$ (c) Subfotat offces aboyc (3r atrd 3b):J 4, Misccllarreous fecs 5(a) Seisnic f€, L%(.01 xpeu l fee L2al): TOTAL fccs and surchnrgcs (2c+3c+4e):s e SigEafure: #71a-7q?-t|c1 3, Plen review fees CITY OF SPRINGFIELD, OREGON Electrical Permit A lication DEPART]IIIENT USE ONLY Permit no.: 16 - 6? 19.7 ^i".rL oate,tt /=alb sP.lxc:lE'.o lErri-tr +-.e6dlkrLe ,f,{q This permit is issued under OAR 918-309-0000. Permits are nortra[sferable, Permits expire if work is trot started within 180 days of issuance or if work is suspeoded for 180 days. r l -marl CCB license no I Sipnrng super"isor's license no. Print name of signing supervisor I BCD hcense noz1 3o/7 s s -7-Ao r Signal circuil or a limited-energl panei. alteration. or extension (2)s 5 LOCAL GOVERNMENT APPROVAL Zoning approval verified? E Yes ! no CATEGORY OF CONSTRUCTION Fl Residential ! Covemment I Commercial JOB SITE INFORMATION AND LOCATION 1{3 Citl: !/')ZIPSrateQ( DESCRIPTION OF WORK trt)NJ PROPERTY OWNER Name: Er,--r--r*F,-r !-t6 r-F_ 1 Address: :a44. E 4dB Avra S-rr= 75,a Cit! : ,:, Lz --\at=State:6f2-ZIP: arl4de\ Phonq,tA \-r{!i-. q4Sr Fax E-mail: ld1as1514 lD Brz€rhc:Lt .,r.aEs <^r-,r This installation is being made on residential or farm property owned by me or a member of my immediate family. This propertv is not intended for sale, exchange, lease. or rent. OAR 479.540(1) and 479.560(l ). Signature: CON'TRACTOR INSTALLATION )JBusiness name: / Address tzl{> Fax FEE SCHEDULE ISuEber of hspections per iteE ( )Qtl Cost ea. Total cost 1,000 sq. fi. or less (4) Each additional 500 sq. ft. or portion thereof s Limircd energ) (2)s 43.00 5 Each manufactured home or modular dwelling service or feeder (2)s 85.00 s Services or feeders: installation. alterot ion. relocation 200 amps or less (2)s'109.00 S 201 to 400 amps (2)s127.00 5 401 to 600 amps (2)s215.00 s 601 to i.000 amps (2)s277.O0 s Over 1,000 amps or volts (2)s63s.00 s Reconnect onlr" (2)s 86.00 s Temporary services or leeilers. installati.,n. aheration. relocat ion 200 amps or less (2)s 86-00 S 201 to 400 amps (2)g 118.00 s 401 Io 600 amps (:)s172.00 s Over 600 amps or 1,000 volts. see serices or feedeG section above BnDch circuits: ,leut oheration. extension per panel a- Fee for braDch circuits with purchase ofa service or feeder fee Each branch circuil $ 7.42 s b. Fee for brdnch ci.cuits r ithout purchase ofa service or feeder fee 5First branch circuit (2)s 86.00 SEach addiaional branch circuil s 7.42 Miscellaoeous fe€s: setu^ice or feeder not included Each pump or irrigarion circle (l)I s ae.oo SEach sign or outhne lighting (2)s 99.00 s 99.00 E.ch additional iDspectionr (l ) DEPARTMENT USE (B) Enter l20% sucharge (.12 x [A])S (Cl Technolos Fee (soi oflAl) TOTAL fees and surcharges (A through D) Lasi edit€d 7/1/2018 B.lon€s (A) Enter subtotal ofabove fees (Mioimum Permit Fet 599.00) 225 Firth Street. Springfield, OR 97477. PH(54, )726-3753 i FAX54l )?25-3589 Residential. per unit. sen'ice included: $181.00 S I Job sire address:Ut s 35.00 Reference;Taxlot.: I t--lt )?/ Crty: 7 Ub S,at{71 Phone: qrB-EA)7 Sigrature of sigring supervisor: frrtlL ,/ _y),<krL"7 s s JOI'RNAI- OR JOB NI'MRER: NAME OR COMPANY: LOCATION: TAX LOT NUMBER: DEVELOPMENT TYPE: NEW DWELLING TJNITS II,,IPERVIOUS AREA l6-2782 BREEDEN HOMES 1702101203400 S e ramil ITf,]\I I TOTAL - STOR]U DR"{INAGE SDC , SANITARY SFWFP . 'ITV ISTORMDRAINAGE T RUNOFF TO CITY STORM SYSTEM A ItI:IMBURSE]\{ENT COST IMPERVIOUS S.F B. IMPROVEMENTCOST IMPERVIOUS S.F 2285 00 COST PER S,F 50.194 COST PER S,F s0..12.1 COST PER DFU $165.5.t COST PER DFU s8l 5.1 1 NUMBER OF UNITS I COST PER FEU $lilE9 COST PER FEU s1,59714 COST PER FEU s22 82 ADM, FEE R TI] AREA DRAINING TO DRYWELL 0 CTIAIT(iIJ $671.79 CIIARGI] $968 84 NEW'TRIP FACTOR t00 NEW TRIP FACTOR I00 sl,6{0.61 sl.9{1.60 COST PER TRIP t9 28 COST PI:R IRIP sl66 fl s3.69 t.0s s1,727.8{ sr 2.00r.12 CHARCL s600.06 A RIlIMBURSEMENT COST: NT]MBER OF DFU'S 20 A IMPROVEMENT COST: NUMBER OF DFU'S t0 I I t-N 2 IOTAL - CITY SAr-II,rRY Sf,ITR SDC 3.l RANSPORTATION A. REIMBURSEMENT COST: 9_57 B. IMPRO\EMENT COST ADT TRIP PGTE 957 ITI]\1 ] TOTAL. TR{\SPORTATIO:{ SIrc 4 SANITARY SEWER . MWMC A REIMBURSEMENT COST NI]MBER OF EEUt I B lMPROVEMENT COST NUMBER OF FEU'S I C COMPLIANCE COST I NAVMC CREDIT IF APPLICABLE (SEE R-EVERSE) MWMC ADMTMSTRATIVE FFE I[t]U I TOTAL - \{\I'tlC SA:i I T.\RY Sf,\\TR SDC ST'BTOTAL (ADD ITf,IIS ',2, ], & .T) 5 AI)MINISTRATT\E FEE SUBTOT I $ 12.001.12 TOTAI STORM ADMIMSTRATION FEE TOTAI SEWER ADMINISTRATION FEE: TOTAI TRANSPORTATION ADM INISTRATION FEE TOTAI MWMC ADMTNISTRATION FEE - LOCAL 0 L UILDINC SIZE(SF):2245 LOT SZE (SF) MAX.l50 6 1 s968.8{ s3Jr0.80 s1.630.80 $t8.1.51 s1,506.5.1 sl3l.89 s 1,597..t.t s22.82 (s34.31) s10.00 s82.03 2.17.08 s18.1.55 s86.39 $12.601.18 1070 I09l r09l t093 109'l 105-l 1055 I054 r056 1079 t0'77 1078 ulao F2E-EW! PREPARED BY Sleven P€tersen DATE 12/6t10t8 ].OTAI- SDC CIIARGES CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT WORKSHEET ]583 \{TUS LN NUMBER OF UNITS 2285 00 ADT TRIP RATE s671.19 14375 FuMnER oF ILU! DRAINAGE FIXTURE UNIT (D CALCULATION TABLE NUMIIIjR OE NEW FIXI URI-S x t-,NIT EQUIVAIENT - DRAINACE FIX'ttlRE UNIIS rOR REMODELS, CA-LCULATE ONLY THE NET ADDITIONAL FIXTTJRES NO. OF FIXTURI]S TJNIT FIXTURE TYPE NEW OLD E UIVALENT MISCELLANEOUS DFU TYPE NTJMBER OF EDU'S TOTAL DRA.INAGE I.'IXTURE UNITS D$cl Unil)isa le fami dsclli 20 DFl-rs sei ar 167 MWMC CREDIT CALCULATION TABLE: BASED ON COUNTY ASSESSED VALUE DRAINAGE FIXTURE LINITS 20 0 .EDU $5.29 $s.19 $5.12 $4.98 CREDIT FOR LAND (IF APPLICABLE) 1998 $4.80 $4.63 $4.40 $4.07 $3.67 $3.22 $2.73 $2.25 $1.80 VALUE i 1OOO $71.48 CREDIT RATE s0.48\ CREDIT FOR IMPROVEMENT OF AFTER ANNEXATION) VALUE / IOOO CREDIT RATE $0.00 x $0.48 TOTAL ]IIWMC CREDIT$1.59 $1 .45 $1 .25 $1.09 $0.92 $o.72 $0.48 $0.28 $0.09 $0.05 I}A fI ITUB 1 0 3 3 I)ItINKING FO[IN1'AIN 0 ITI,oOR DRAIN 0 INTERCEPTORS FOR GREASE / OIL i SOLIDS / ETC 0 INTERCEPTORS FOR SAND / AUTO WASH / ETC 0 2 CLO'TIIESWASHER / MOP SINK CLOIHESWASHER - ] OR MORE 0 MOBILE HOME PARK TRAP I PER TR ILER 0 0 RECEPTOR FOR REFRIG / WATER STAI'ION / ETC.0 RECEPTOR FOR COM. SINK / DISHWASHER / ETC SHOWER. SINGLE STALL sito GAt'\C I]MI]ER OF HEADS 0 SINK: COMMERCIAL/RESIDENTIAI KITCHEN 3 SINK: COMMERCI I- BAR 0 SINK: WASH BASIN/DOUBLE LAVATOITY 0 SINK: SINGLE LAVATORY/RESIDENTIAI, BAR 4 URINAL. STAIL / WALI-0 TOILE PTIBLIC INSTAI-LATION TOILET. PRIVATE INSTALLATION 0 20 YEAR ANNEXED CREDIT RATE/$I,OOO ASSESSED VALUE BEFORE I979 t919 1980 l98t l98l 1983 198.1 1985 $34.31 1986 1987 1983 1989 1990 I99I 1992 l99i 1991 1995 1996 1997 1998 1999 2000 t00l IEEI 1 I IS T,AND ELGIBLE FOR ANNEXATION CREDIT? (Enter I for Yes, 2 for No) IS IMPROVEMENT ELGIBLE FOR ANNEX. CREDIT? (Enter I for Yes, 2 for No) BASE YEAR 3 3 0 0 #lolol3l=lo1016l=lilol2l= ffi W ILATJNDRY TUB I o I 12 I=r lololll=lllol3l=W T?i O I ,I=ffilol4tor------lo I o---f--2lolllolslol6l---.---f--.- l-- SPnrNGftaL0 ww spnngfield'or gov Worksde addressr 3583 VITUS LN, SpringneE, OR 97477 Transaction Receipt 8l l-t8-002782-DWL R6celpt Number:468721 R6ceipt Date: 11/30/18 Developmert and Pubhc Works 225 Ftfth Stret Sprngneu, OR 9)4'77 541-726-3751 p€rm'tcenter@spnngfi eld-or 9ov Ciiy ot Spnnsr'eld Fees Paid 11/30/18 1.00 Ea Slruclural plan review lee 224-0000G425602,1 030 $1.098 54 11 096 54 Credit card aulhorizalon: 09704m Payer: John Thompson $ 1.096 54 Cashier Chris Carpenter t1,098.5,1 FN T€ns.crbnR.6rpr_t/ & 225 FIFTH STREET . SPzuNGFILLD, OR91477 . PH:(541I726-3'/ s3 r FAX: (s41)'726-3689 One and Two Family Dwelling Building Permit Application Checklist NOTE: Missing information that is required for complete plal review can delay the permit process until all required information is provided. Permits will not be issued until the completed plan review is approved. Received Date n 2 complete Sets of Legible Plans Including site Plan A on 11 x 17 paper at minimum fil Must be drawn to scale, showing conformance to applicable local and state building codes, to include the following: EtruEg tr V D E tr Site/Plot Plan Foundation Plan E Dimensions tr d tr d Footing sizes, Isolated footings, Step Foundations and Retaining Walls A Hold downs and reinforcing type, size and spacing Connection details Vent size and location cripple Walls Girder sizes and locations A Joists or post and beam type, sizes and spaclng T:\Buildilg Forms\one_a.1d_two-farnily-dwclling buildingjemit checklist.05.09.doc APPUCATION INTAKE REVIEW WILL BE CONDUCTED FOR ALL RESIDENTiAL PERMITS. Address i5 83 V rrus LANE Associated Permits: E Electrical I Plumbing E Mechanical E other: Permit #Ma p/Lot 1702 tg{3 34oo a tr Land and Drainage Alteration Permit (LDAP) All new one and two family dwellings require an LDAP Refer to Fact Sheet 1.1 to determine type of LDAP Drawn to 1 :20 scale with scale indicated North arrow Adjacent street names and street elevations shown Building setback dimensions (Distances from property lines) Location of easements and driveway Location of utilities and how they are connected Footprint of structure (includjng decks, porches, roof covers) Location of wells/septic systems Lot dimensions Building coverage and percentage of impervious surface in hillside areas Show all existing structures on site; indicating height of all structures inclusive of ridgelines Site Topography in 2'-0" Increments including SurFace drainage Show how stormwater and wastewater connect to the public system, septic or drywell. Show orientation of structures q- t-Tl F r Plans show dimensions Identify all rooms Include window and door sizes .Locations of: Smoke and carbon monoxide ala,rms, water heater, furnace, ventilation fans, plumbing fixtures; balconies and decks 30 inches or more above grade, porches, stairs/ etc... tn[! f sd;atu.e (Ase"t) JO-lr"nil'lr6dJ ( Print Name) T:\Building Forms\One_and_two_family_dwellinlbuildingjcrmit_checklist.05.09.doc D cross section(s) and Details d Show all framing member type, sizes and spacing such as floor beams, Headers. joists, sub-floor, cripple wall and \,{all conslruction, roof construction and metal connectors (More than one cross section may be required to portray construction clearly) Show details of all cripple walls, wall and roof sheathing, roofing, roof slope, ceiling height, siding material, footings and foundation, stairs, flreplace construction, thermal insulation, etc... Show attic ventilation Energy Path: Example - High Efficiency HVAC ,, . Agent/ Builder l*ll*,,,.- tr Elevation views Provide elevations for new construction E Exterior elevations must reflect the existing and proposed grade if the change in grade is greater than two feet at building footprint tr Floor/Roof Framing E Etld En Beam calculations, especially for engineered wood products and non- u niform loads Provide plans for all floors/roof assemblies indicating member sizing, spacing and bearing localions, including decks, porches, Toof covers Metal connectors and tie straps clearly shown Show headers and beams supporting floor or roof Prescriptive lateral bracing and/or engineered shear walls ineers Calculations Wet-signature stamped engineering calculations, specifications and details shall be provided where required. Manufactured Floor/Roof Truss Design Details must agree with plans and engineering The undersigned acknowledges that the information in this application is correct and accurate OR Property Owner 'll lr,-1,r,Sig nature (Owner) Date (Print Name) -v- JL +T 4rt- t_ d tr f1--T-- RIVER HEIGHTS SUBDIVISION - LOT 39 THIS DOCUMENT IS PROVIDED FOR INFORMATIONAL PURPOSES TO ASSIST IN INDIVIDUAL LOT DEVETOPMENT. REFER TO THE SUBDIVISION PLAT, RECORDED COVENANTS, CONDITIONS AND RESTRICTIONS, AND CITY OF SPRINGFIELD DEVELOPMENT SERVICE DEPARTMENT FILES FOR 1. This document is for grophic representoiion ond owner notificotion ond is NOTA LEGAL BOUNDARY DOCUMENT, All dimensions ond oreos shown ore opproximote ond the recorded finol ploi sholl be consulled for oll legol boundory issues. 2. Limiied subsurfoce explorotion hos been preformed on ihis sile ond is summorized in 3 reports by GeoScience, lnc. Home foundoiions ond locotions sholl meel lhe recommendotions of lhese reporls. Prior to home cons+ruciion lhe individuol lot sholl be reviewed for conformonce with lhese recommendotions by GeoSicence or other opplicoble professionol. For lhis lol shollow spreod fooling foundotions ond concrete slobs-on-grode is oppropriole in Design Areo 2. lnslollotion of doylighi bosemenls will present difficulties wilh excovoiion. ldeolly, foolings ore constructed beoring on PDS or STSVFS RU-101, foundolons con be designed for ollowoble beoring pressures up 1o 6,000psf. 0n CDS RU-101 beoring pressures should not exceed 1,500 psf unless oddilionol meosurements of soil strength ore conducled of the specific site. TRACT ''B" PRISERVATION AITIA LOT #38 0 40 \---\--ri\ \i \\)L\ \] -. .-.--.--r:-li.....,tI , , .ll r-: ' l [-'-..---J I t]-+ lr]r+EE=I--]I:rf] High efficiency waUs 1 Er(terior wa s U-0.045,&-21 cavity insulatiotr + R-5 contiruoEs upgraded features 2 Exterior walls U-0.057/R-23 iDtemoeiiiate or R-21 adyanced, Framed fl oo$-U-0.026,&-i8, and Windo\rs U-028 (average UA) Uoorade.l leatures Extdior wa[s-U-0.055/R-23 intermediate or R-21 edy ancEd" Flat ceiling'-U-0-017R-60, and Framed fl oors'-U-0-026,&-38 Super lnsulated Windows and Attic OR Framed Floors 4 Witrdows-U-0.22 CftpIe Paae Low-e), and FIat ceiling"-U-0-017,4.-60 or Fraoed fl oo$-U-0-0261R-3 8 Air sealing home and ducts )0i ASHRAE and62_2, High eificiency thermal envelope UAs 6 ProDosed UA is 8% lower than the code UA I = E o Air soErce }eat Plrep IISPF 9.5/15.0 Sm cooliDg, or Grould source heat pnmp COP 35 or Ener6/ Star rated Hish efficieicy HVAo systema Docted HVAC systems within conditioned space B AIi ducB and air handlers coDtained $,ithin bBilding etrvelope Cannot be conbined witll Measurc 5 Ductless heat pump C Ducdess heatpEmp HSPF 10.0 in ldEary zone of dweling High efriciency urater heatef 3a =cEo.96E9 D Natural gavpmparc vrater heate! with IIEF 0.85 OR Blectsic he3l pump water beate. Tier 1 Northem Ciirtrate Specificatiotr Product ENEBG\' EFFICIENCY For SL I squrre foot = 0.093 m1 1 s,att per square foot = 10.8 Wm2. & Appliances located witlin &e builditrg ttrefoal mvelope sba]l have sealed combustion eir instaled- Combustiotr air shall be ducted direcdy Aom the ouldoors. b. AI ductjoiats sld seams sealed witb listed mastic; b!'e is oDly allowed al appliance o! equipEeDt coDnections (for seflice aod replaceroeut). Meet se€IiDg cdte.ia ofPedoErarce Tested Cosfon Systems Fogram admisistered by the BoDneyille Power AdEitristsatioD (BPA). c. Residerfial water h.ate$ Iess thatr 55 gallo! storage volme. d- A total of 5 perccrt ol atr EVAC system's duct;o* shall be permised to be located outsidc of the cotrditioned qpace. DBcts located outside ihe cotrditioned Wace shdl havc insulation installed as lequiled in this code. e. The rDaximuE vaulted ceiling suface area shal Dot be gre3ter tban 50 perEent of tbe total heated space floor alea uDless vaulted aIea has a U-f&ctor ao gEater tla.o U-0.026, i CoEtinuous air ba[ier AdditioDal requireme ffi sealing of a]I inteior verticrl wall.coyeliDg to top piate fraraiDg- SealiDg with foaE gasket caulk or other approved sealaot Usted for sealing wall covering material to sEuctural material (errmple: gypsum board to wood suid f.amiEg). g, TaHe Nf104.1(1) Standard base case desigD, Code UA shdl be at leas! 8 perc€li less thaD the Proposed UA. Buildirgs vdlh feDestration lcss than 15 p€rcent of the total vcnical wall alea may adjust the Code IrA to lave 15 perceDt of ihe wall a.rea as lbDestralion- 2O17 OREGON RESIDENTIAL SPECIALTY CODE 435 TABLE NI101.1(2) ADDITIONAL IIi]EASURES IITIIIIIII :II Check fire/sound separation assembly on 2 family dwellings Check for smoke alarms/Carbon Monoxide alarms (look on electrcial sheets if there aren't any shown on floor plan) Check wall bracing Check minimum room size Make sure that minimum bathroom fixture distances are met Check to make sure stairs meet code Check roofing material(composition shingles, Spanish tile, metal, etc.) Check for attic access and underfloor access on plans Check beam sizes Read over all the general notes to make certain that nothing was missed and there are no conflicts Make sure that Willamalane form is attached. Transfer all notes made by other work Broups until there are two identical sets of plans (.jobsite and city set) lnclude standard attachments : Exterior Wall Envelope 5elf-Certification Form Moisture Content Acknowledgement Form High-Efficiency Lighting Systems Oregon Residential Specialty Code (ORSC) Noise Ordina nce Notice Smoke Alarm Ventilation Requirements for Kitchens and Bathrooms Green Approved Plans Cover Sheet (Found under "Cover" in file cabinet) Add a ll inspections and fees into Accela (including Willamalane fee and addressing fee) Stamp plans with the "Reviewed for Code Compliance" stamp, sign the approved by line and perforate Approve Building Review line in Accela & call or email application with fees due and attach placard to jobsite set Signed electrical a pplication received Print out the Fee Schedule and put it with the Willamalane Spreadsheet on the outside of the folder Put any inspection notes into Accela that need to be there before the plan is issued. Plan check items/notes rrrtcc{€3A14< T TIllIIltIxI AIII sL-4 '.i I Plqn Review Checklisr xId 5! E Ez T vtg E E Check address on plans is correct Check to see if LDAP has been issued. s\oa rraL^stt 'tE7 16 - aooBBPlF.{ - Read all comments from other work groups to see if anything needs to be considered during structural review. Check Setbacks on Site Plan Check RLID to make sure taxlot matches what is shown on drawings, that topography lines are on the plans and that owner info matches Check to see if lot is sloped or flat - tf ffiel wiil back deck meet setbacks lf a new home is being built at fUountffi?e or River Heights, check the subdivision books to see if a Geo-Tech report is req. Check soils to determine whether or not a Geotechnical evaluation should be required lf property is on septic, check for proper setbacks from building to tank, distribution box, and leach field Make sure that property is not in Flood Hazard A affected property according to Mapspring (if it is we need 3 engineers surveys) Check that everything required to be engineered has engineering and that the stamp is current Check the truss package and make sure it matches the plans (qty of trusses, type, attachements) - lf the numbering doesn't *match but the uplift and reactions look correct it is OK. Falls under field verify +Make sure that if there is HVAC equipment in the attic, the trusses were designed to support it lf rafter framing, check spans Check to see if anything over 4000lbs is bearing down on strip footings. lf so this needs to be enlarged. Check Hold Downs Check Foundation Venting Make notes on plans with stepped foundations how far back they need to be from the edge ofthe cut and the uphill cut. Check header sizes Check footing sizes Make sure that if rebar is used that it has minimum cover depths. t{oFt sr-tou }., o*r F>LAtwj _ Fr5'L6, Wat}tF-( Check energy code requirements Bur:b,\Ti q) l\j,pl,i(-iroF ,*Make sure that insulation called out meets the energy code and if not make note of the required R value. *On additions/remodels where existing conditions come into play, see code section N11.01.3 & table N1101.2 Check tempered glazing (hazardous locations, windows in stairwell, within 24" of door, etc) ' ' ctreck bedio?jrtfs tor egresi l*indo* sizes, make (ur6 tlat'gdiage dooi io hoirse doesn'f g7o into bedro;ms) Check to see if there is a living area above the gara8e, if so, make note of 5/8" type X gyp board fire separation requirement. Check for mechanical equipment protection (bollards) in the garage lf DETACHED garage is being built less than 3ft to existing structure it needs to have 7/2 gyp board on the interior walls err re'vrr.ra 4 [Id ts BI BaF E E E Eut,,a