Loading...
HomeMy WebLinkAboutApplication PWE 1/17/2008 I) 1110<:6 LAND DIVISION TENTATIVE PLAN APPLICATION PRE-SUBMITTAL CHECKLIST Engineer: Matt Stouder Case#: PRE2008-00002 PUBLIC WORKS ENGINEERING o Site Assessment of Existing Conditions Complete Incomplete See PW Note(s) !g[ 0 !g[ 0 !g[ 0 !g[ o !g[ o !g[ o !g[ o !g[ o Revised 10/25/07 Prepared by an Oregon licensed Landscape Architect or Engineer VIcinity Map The name, location, and dimensions of all eXisting site features including bUildings, curb cuts, trees, and Impervious surface areas, clearly indicating what IS remaining and what IS being removed For eXisting structures to remain, also indicate present use and required setbacks from proposed property lines The name, location, dimenSions, direction of flow and top of bank of all watercourses and required riparian setback that are shown on the Water Quality limited Watercourse Map on file In the Development Services Department The lOO-year floodplain and floodway boundaries on the Site, as specified In the latest adopted FEMA Flood Insurance Rate Maps or FEMA approved Letter of Map Amendment or Letter of Map RevIsion The Time of Travel Zones, as speCified In SDC 3 3-200 and delineated on the Wellhead Protection Areas Map on file In the Development Services Department PhYSical features including, but not limited to trees 5" In diameter or greater when measured 4 V2 feet above the ground, significant clusters of trees and shrubs, riparian areas, wetlands and rock outcropplngs 5011 types and water table Information as mapped and specified In the SOils Survey of Lane County A Geotechnical Report prepared by an Engineer must be submitted concurrently If the Soils Survey indicates the proposed development area has unstable sOils and/or a high water table Date Received'_ff~t7t'/ Planner. AL 0 Land Division Tentative Plan Complete Incomplete See PW Note(s) ~ 0 0 ~ 1,2 ~ 0 ~ o ~ o o Stormwater Management Plan Complete Incomplete See PW Note(s) ~ ~ o o ~ ~ ~ o o o ~ o o ~ 3 Prepared by an Oregon licensed Land Surveyor In accordance with ORS 92 Location and width of all eXisting and proposed easements on and abutting the property Boundaries of the entire area owned by the property owner, of which the proposed land divIsion IS a part, as well as dimensions and size of each parcel and the approximate dimensions of each building site Indicating the top and toe of cut and fill slopes to scale Location of eXisting and reqUired power poles, transformers, neighborhood mailbox Units, and similar public facIlities Location and size of eXisting and proposed utilities on and adJacent to the site Including sanitary sewer mainS, stormwater management systems, water mains, power, gas, telephone, and cable TV Indicate the proposed connection pOints Prepared by an Oregon licensed Civil Engineer Planting plan prepared by an Oregon licensed Landscape Architect where plants are proposed as part of the stormwater management system Roof drainage patterns and discharge locations Pervious and Impervious area drainage patterns The size and location of stormwater management systems components, Including but not limited to drain lines, catch basins, dry wells and/or detention ponds, stormwater quality measures, and natural dralnageways to be retained EXisting and proposed spot elevations and contours lines drawn at 1 foot Intervals (for land With a slope over 10 percent, the contour lines may be at 5 foot Intervals) Amount of proposed cut and fill o Stormwater Management System Study - proVide four (4) copies of the study With the completed Storm water Scoping Sheet attached The plan, calculations, and ReVised 10/25/07 Date ReceIved. //l/)<JO( Planner. AL I / I , documentation must be consistent with the Englneenng Design Standards and Procedures Manual I Complete Incomplete See PW Note(s) ~ ~ w:!J Scoplng Sheet and attached Stormwater Management System Study PW Notes: 1 The 7 foot PUE proposed along the north property line should be replaced with a pnvate utility easement 2 An easement will be necessary for the pnvate sanitary sewer and stormwater systems (including the bloswale) that serve both proposed parcels 1 & 2 3 Please Indicate the amount of cut and fill for the proposed partition, even If the amount IS zero cubic yards Additional comments not related to the completeness of the application: . The applicant proposes a 24 foot dnveway on the north portion of the site along 2nd J street Is this dnveway eXisting? . A JOint-use maintenance agreement will be required for the bloswale that serves both of the proposed properties . Site inspection of the property indicates a large grade difference between the property to the north and the subject property Revised 10/25/07 Date Received /o/}v,1f' Planner. AL '~", ~:.:-"~ " / II " 1 '~~J .. i~' ":':'..J. I' ./~ '4 oJ- .~- .J') . .. "', 1- ('\ir' "'~. ,.. ~ '. Date Received' Planner: AL {l7jzCIJ!