Loading...
HomeMy WebLinkAboutSpecial Inspection Correction Notice 1982-9-2 ..-. "--" . ;'" '~" 'II -' ,; ~-)' 1,_" " " 'C', '. " y.' /_"~_._ :J'; f' 1..,--""..., I ":!~: ._. ::<If SPRINGFIELD c::.IMRL./el W/Mr IS rIfE srlf7vs o,&:. TIY/S? U>l'f.1;E tfP--.2.5'-8":2.. CITY OF SPRINGFIELD Department of Public Works September 2, 1982 CERTIFIED LETTER I ./ Lost Dutchman Restaurant 535 ~Iain Street Springfield, Oregon 97477 Dear Business Owner: .On September 1, 1982, the Springfield Fire Department requested an electrical.inspec- tion of the wiring methods in the area of the dance floor. The inspection has revealed the following defects that must be corrected within 15 days of this notice. 1) Install conduit to the signal light over, archway. Oregon State Electrical Specialty Code (O.S.E,S.C.) 518-1 2) Supply conductors to the transformer, mounted adjacent to the signal light (shall be in conduit). Open terminal type transformers shall be installed within a metal enclosure. O.S.E.S.C. 518-1 3) Install receptacle outlets adjacent to electrical cord connected to equipment (~ecord player). Conduit is required. O.S.E.S.C. 210-50 (b) and 518-1 4) Remove cable type wiring to sign and lights above the main entrance (conduit required). O.S.E.S.C. 600-21 (a) 5) Remove or repair defective conduit and sign at rear entrance. O.S.E.S.C. 110-3 (a) 8 6) Contact an Oregon Licensed Electrical Contp,ctor in regards to the,;above mentioned electrical corrections. (! its . tJ.~7J Springfie17dUi ing - .-I Division at 726-3753. Please direct all inquiries to the Sincerely, cc: ~Iike Hudman Springfield Fire Department / ) Charles Watson Electrical Inspector 225 North 5th Street 1701 CIW-ttA- J I - I - F 2- , c aY.Y &71' k€'\ , '-- r 0/;?1j/ded /;2. -:2 - ffJ- . Springfield. Oregon 97477 · 503/726,3753 CW/lh . . SPRINGFIELD CITY OF SPRINGFIELD Department of Public Works September 2, 1982 CERTIFIED LETTER Lost Dutchman Restaurant 535 Main Street Springfield, Oregon 97477 .I Dear Business Owner: ,On September 1, 1982, the Springfield Fire Department requested an electrical inspec- tion of the wiring methods in the area of the dance floor. The inspection has revealed the following defects that must be corrected within 15 days of this notice. 1) Install conduit to the signal light over, archway. Oregon State Electrical Specialty Code (O.S.E.S.C.) 518-1 2) Supply conductors to the transformer, mounted adjacent to the signal light (shall be in conduit). Open terminal type transformers shall be installed within a metal enclosure. O.S.E.S.C. 518-1 ',3) Install receptacle outlets adj acent to electrical cord connected to equipment (record player). Conduit is required. O.S.E.S.C. 210-50 (b) and 518-1 4) Remove cable type wiring to sign and lights above the main entrance (conduit required). O.S.E.S.C. 600-21 (a) I, . ... 5) Remove or repair defective conduit and sign at rear entrance. O.S.E.S.C. 110-3 (a) 8 .6) Contact an Oregon Licensed Electrical Contractor in regards to the',;above mentioned electrical corrections. Please direct, all inquiries to the Springfield Building Division at 726-3753. Sincerely, (! -ts . MJicr7 Charles Watson Electrical Inspector cc: Mike Hudman Springfield Fire Department CW/lh 225 North 5th Street . Springfield. Oregon 97477 · 5031726.3753,