HomeMy WebLinkAboutPermit Miscellaneous 1988-3-24 ~_..- " . . ()dc/AM:J ~ CITY OF SPRINGFIELO Planning and Development Department DATE OF LETTER March 24, 1988 APPLICANT ~t~~~~t~i~! Ave. ........ ,.r:~j ...::11...a, u" ,7 Attn: C. F. Christian, Jr. SU8JECT CITY JOURNAL NUM8ER 88-03-38. Type I Site Plan Review Application - Minimum Development Standards - 3112 Industrial Ave. - Zoning/LMI Light Medium Industrial; Metro Plan Designation/Light Medium Industrial; Refinement Plan Area/Mid-Springfield - Assessor's Map# 17023034;'Tax Lot# 4800 and 4900. (Note: Future Logging also owns Tax Lnt 4700 to the north which is zoned and designated LMI and Tax Lot 700 (Assessor's Map# 17023121) and Tax Lot 100 (Assessor's Map# 17023122) which are zoned and designated Heavy Industrial). The properties to the east and west of this property are designated Light Medium Industrial, however, they met the criteria in the Mid-Springfield Refinement Plan to retain their Low Density Residential zoning. ,The property to the north is zoned Light Medium Industrial; the property to the south is zoned Heavy Industrial. The applicant proposes to remodel the existing building and add additional office space. There was no Pre-Application Conference. ACT! ON PRELIMINARY SITE PLAN APPROVAL subject to: 1. Requirements under Site Plan Review Criteria of Approval; and 2. Minimum Development Standards to be met (See Attachment A); and 3. Mid-Springfield Refinement Plan. WHAT NEEDS TO BE DONE TO OBTAIN FINAL SITE PLAN APPROVAL? 1. A Final letter. Site Plan drawn to scale is required within 90 days of the date of this The following revisions need to be shown on your Final Site Plan: a. The paved parking area showing the required 14 parking spaces to meet the off-street parking requirement. h. The required 5 foot planting strips along Industrial Avenue and N. 31st Streets to include required street trees. c. The slats added to the existing fencing around the storage area. d. If the existing storage area is used for the required parking, the paved area and the new access point. If another area is used, it must be shown. . . - .~.'a Page 2 Future Logging Type I Review 2. The signing of an Improvement Agreement for Industrial Avenue and N. 31st Streets. 3. A signed Development Agreement. This agreement will be prepared by staff upon approval of your Final Site Plan. APPEAL If you wish to appeal this Type I Site days of the date of this letter. Development Code, Article 15, APPEALS. Plan Review decision, 'you must do so within 10 Your appeal must be in accordance Springfield PREPARED B~ ,I ~ ~ ~ /'~ ~p Associate Planner Copy To: DRC Members _._.4 i . . ATTACHMENT A FINDINGS CRITERIA DF APPROVAL (Ref. Section 31.060 of the SDC). [X] OEMONSTRATED COMPLIANCE WITH APPLICABLE STANDARDS OF THIS CODE. When the Minimum Development Standards below have been met, this application will have demonstrated compliance with the applicable standards of this Code. [X] PARKING AREAS AND INGRESS-EGRESS POINTS HAVE BEEN DESIGNED SO AS TO FACILITATE TRAFFIC AND PEDESTRIAN SAFETY, TO AVOID CONGESTION AND TO MINIMIZE CURB CUTS ON ARTERIAL AND COLLECTOR STREETS. When the applicable Minimum Development Standards below have been met, this criterium will be met. MINIMUM DEVELOPMENT STANDARDS TO BE MET (Ref. Section 31.040 of the SDC). MDS ARE APPLIED IN LIEU OF FULL SITE PLAN REVIEW TO ENSURE MINIMAL COMPLIANCE WITH APPEARANCE AND SAFETY STANDARDS SPECIFIED IN THE SPRINGFIELD DEVELOPMENT CODE AND TO REDUCE PROCESSING TIME FOR DEVELOPMENT APPROVAL. THE FOLLOWING ARE CONSIDERED MINIMAL DEVELOPMENT STANDARDS: [X] THE DEVELOPMENT MUST CONNECT TO PUBLIC UTILITIES. The existing building is connected to pUblic utilities. Storm drainage is by ditch, however, an Improvement Agreement will be required. [X] THE DEVELOPMENT MUST COMPLY WITH THE SPRINGFIELD BUILDING SAFETY CODES. The proposed use requires a Building Permit for the new construction' and any required paving. [X] PARKING AND CIRCULATION AREAS MUST BE PAVED AND STRIPED, AND WHEEL STOPS MUST BE INSTALLED. The existing building's floor area is 3,520 square feet. The office area is currently 1,120 square feet. At one space for every 300 square feet of gross floor area, 4 parking spaces are required. The remaining 2,400 square feet is used for warehousing. At one space for every 600 square feet, 4 parking spaces are required. Therefore, before expansion, a total of 8 off-street parking spaces are required. After expansion, the office space will be 3,200 (11 spaces) square' feet and the warehouse space will be 1,360 (3 spaces) square feet. A total of 14 parking spaces will be required, a net increase of 6 parking spaces. . . . ..,-. Page 2 Future Logging Findings The plan shows 11 existing parking spaces which are either in the pUblic right of way or back into the pUblic right of way. Typically, only three additional off-street parking spaces would be required (11+3=14). However, nine of these parking spaces are shown within the public right of way. These parking spaces cannot be permitted to continue for the following reasons: 1. Section 31.170(6) of the Springfield Development Code states: spaces in the pUblic right of way shall not be counted as fulfilling of the parking requirements for a development." "Parking any part 2. Section 31.190(4) of the Springfield Development Code states: parking areas of less than 4 spaces on a residentially zoned into the pUhlic right of way, other than alleys is prohibited." "Except for lot, backing 3. Staff could not find a permit for the paving of the parking area along the frontage of Industrial Avenue. Even if Future Logging applied for a permit, it would not have been issued, since Industrial Avenue is listed as a Minor Arterial which would not allow driveway access. The only driveway access which would be permitted to serve this property would be from N. 31st Street See #1 below). 4. This is a dangerous situation. If there was an accident, both Future Logging and the City may be liable. The requi red parki ng (14) spaces property owned by Future Logging. requirement: will need to be located elsewhere on the There are two options to meet this 1. The existing storage area which straddles Tax Lot 4700 to the north may be used to provide the 14 paved parking spaces (only the parking and maneuvering areas would have to be paved). However, Table 32-4 of the Springfield Development Code requires the driveway to serve the off-street parking to be 150 feet from the intersection of Industrial Ave. and N.31st Street. There may be a conflict with the existing mobile home on Tax Lot 4700. 2. The property owned by Future Logging to the south may be used to provide the 14 paved parking spaces. [X] CURB CUTS WHICH EXCEED THE STANDARDS OF THIS CODE MUST BE CLOSED AND REPLACED WITH STANDARD CURB AND GUTTER, AND SIDEWALK WHERE NECESSARY. There are no curb cuts on Industrial Ave. or N. 31st Streets. The minimum access to the relocated parking area needs to be 24 feet wide. [X] SIDEWALKS MUST BE INSTALLED WHEN THE SITE ABUTS A CURB AND GUTTER. A, PUBLIC IMPROVEMENT AGREEMENT MUST BE REQUIRED WHEN THE SITE DOES NOT ABUT CURB AND GUTTER. There are no existing sidewalks along Industrial Ave. or N. 31st Street. The site does not abut curb and gutter along Industrial Ave. or N. 31st Street. tn"refore an Improvement Agreement will be required to be signed. .~~ , . . Page 3 Future Logging Findings [X] A 5 FOOT WIDE LANDSCAPED PLANTER STRIP WITH PERMANENT IRRIGATION MUST BE INSTALLED BETWEEN THE STREET-SIDE PROPERTY LINES AND PARKING AREAS OR STRUCTURES. IF STREET TREES DO NOT EXIST, THEY MUST BE INSTALLED IN THIS PLANTER STRIP. The applicant shows a planting area at the intersection of Industrial Ave. and N. 31st Streets. Most of this area appears to be in the pUblic right-of-way. The Springfield Development Code requires the five foot planter strip to be placed behind the property line. Street trees will be required in the planting strips which are adjacent to the streets. [X] STREET LIGHTS MUST BE INSTALLED. No additional public street lighting will be required. [X] TRASH RECEPTACLES AND OUTDOOR STORAGE AREAS MUST BE SCREENED. An outside storage area is shown. The existing fence needs to be slatted. INDUSTRIAL DEVELOPMENT POLICIES (Ref. Mid-Springfield Refinement Plan) [X] THERE IS A NEED TO PROVIDE FOR SUFFICIENT ON-SITE PAVED AREA FOR MANEUVERING OF TRUCKS AND OTHER VEHICLES THROUGH THE SITE PLAN REVIEW PROCESS. This policy will be met when the relocated parking area is paved. OTHER INFORMATION 1. Comments from Springfield Utility Board Water Department: The applicant will not be required to pay additional development/redevelopment charges or install additional backflow prevention other than the backflow prevention device required for the irrigation system. The applicant should contact Bill Scott at SUB with regard to the type of irrigation system and backflow prevention device necessary. 2. The east wall of the existing building needs to be of one hour fire-resistive construction. Please refer to Item #5 in the enclosed Plan Review Correction List.