Loading...
HomeMy WebLinkAboutPermit Curb Cut 1990-5-23 ; ~ 97477 Job Loca.ti.on: ci..J ( ) X)< ~\,~~ f\C\\. II \~D< 6\\ ~Q Tcz lAot \U lliI\ _ /I (JI4(]) ASDOGGOl'C Map Subdi.vision: ','. o.ner: T~ \)0 - ~ Qj1t AddreBBdDyC?< &~(l nl11, phonc:l71n -Cf{(OL.. City: ~<<N ~ -- Zip: Lh411 nN,.f.} n .1dditicn n Rcmodnl n ,'.fobill! Homa ~ () Q qO ,Dataaft~'catiC" '0'L0' " Contract rs ....') Address Gencfi-al II W ../ i PIUlMng , i Hechanical . I Electrical I SUDeti~r~;;T.lg Electr.~cian Describo rl'Ol'k: \Df ~\0~ Value V\.~ Receipt ,~ L215 ") ~ Siqr.cd: Data: ~~ -;'q,- L ~~'-1{) Lise. II Bldrs Board Ke~. gXDi'((~s Pl,onp It is tho responoibil~ty of the pe~t hoLder to Bee that all inopectionG ar'e made at ~he propel" ti.m~~ tr.at ~ach ~esG is l'aadabZe, fl"Oln the otreot, and that the pe1'lT't'it card is l:>aated at the front of the property. A!JuiZding D":vicio!': appl'oced Flan shazz. r'f!main 07J the; Building sit:; at azz. timas. P.70CSDUP.E FOR INSPECTION RE:QUEST;CALL 726-3769 (recorder) state your City designated job mm:ber, job address, typo of in.3pec~ic'l requested ar.d whon you will be ready for inspcct--;onJ Contractors 01' Ot.mors name end phone nwnbcr. Requests rscoicsd befera 7:00 c:'I ;,.'ill be made the samo day, l'equasts made a~tc.r 7~'OO am Lri.U be made the nat :.JOrki"i} day. fA () ''l , ' Your City Deaigr.atcd Job Numbor Ia: "-fO fo C'J . R~n:lirr;tf T'l!]"~('!o':ir.7)1=!. D SITE INSPECTION: To be TTKlda aftel' excavation, .but prior te sot up of fo1'11ls. O ' UNDERSLAB PLUMBING, ELECTRICAL 8 : MECHMJICAL: To be made before any work is aovcred. O INSULATION/VAPOR BARRIER INSPECTION: To be made after aU insu lati::m lV".d " required vapor barl'iers are in p lacs , " but before any lath, gypswn board or . wall covering is appLied, and beforo 'anyi~u~twn is c~cooled. o FOOTING & FOUNDATION: To b. made after trenches are excavated and forms ar'O erectedJ but prior to pouring cencret~. O DRyr{ALL INSPECTION: Te be mado after all drywall is in place, but prior to any taping. . o O MASONRY: Steel location, bona beams, grouting 01' verticals in accordance tJi th U. B. C. Section 2415. UNDERPWOR PLU/.fBING & MECHANICAL: 0 r{OODSTOVE: After installation is To be mado prior to installation of ccmpleted. fLoor insutation or decking. ~ POST AND BEAM: To be made prior to CURB ~ APPROACH APRON: Afte:" forms instaUation of floor ins~lation or c created but prior to pouring dccki7l{j. , .:o~rete. ./iOUGll PI,u.-!RIfJG. ET,ECTR'!CAL .e MECR- '0' . SIDEf{ALK & DRII'Er{AY: For ail ~on- AI/IeAL: No work is to be cor.:el'od' crete paving within street right- ,w:ti~ ,these inspections have beim of-wc.y~ to' be made aftel' aU eica- made and approve.::!. vating ccmpleto & form work & aub. FI.r?EPLACE: Prior to placir.q facing , base mateztial in pla::e. ma.teria~s and before framing inspec- tion. UNDSRGROUND Pr..UMlJINC; SErrE.'? W.1TER, DHAINAGE: To be made prior to fil- ,lir.g trenches. o o o o O FRAMING: Must be requeated after approval of rough plurr.bing, alectri- ,cal & mechanical.. AlZ roofing bracing & chimneys, eta. 17f'.lst .be : comploted. lIo L>Orkis to be con- . ': coaled until this inspection has ,'be~n made and approved. O PENCE: When ao.71pl~to -- Provide gates or movable sections through 'P.U.E. ' o I DEMOLITION OR ;',:OVEV BUILDIiICS :=J Sani~ary Sf'!'.J6r ~apped at p~op,cl't~. l.ino :=J Scpt~ tank fT.l.7cd and fit7.8~ with Gra~eZ I Final - ({hen above items are ccmpleted ---1 and when demolition is completo or stru~- ture moued and pro:mi3es cleane:i up. Nobile Hemee =:J Block~ng and Set-~p =:J Plwnbing connections -- Sa.Jor and tJa~el' ---, Electrical. Connection - Blocking, set-up ~ and plumbing 'connections nr~st to appro~ed before raqueoting elec~rical inspec~io~ =:J AccesGol"d Building ---, FilUll - Aftal' p::Jrcr.es, skirting, deck8~ ~ etc. aro comple~ed. o \ ' All projec't conditions, suer. ao tile -::nstallation of s:reot trees, cO::TpZ.oti.:m of tite requil'ed 'landscaping, etc., must be satisfied before tho BUILDINC FINAL can b6 l'squostsd. o FIliAL PLUMBIIIG o FIliAL UECIIAIIICAL o FINAL ELECTRICAL o o FINAL BUILDING: Tho Final Buildina Inopcctio,:! fmlot bo requ6ated aftor tllc Pinal. Plumbina Electrical, and Mocllanical Inspections hava been made and approlU!d. .), ..J .' .AU. /.Ml.'I1CU:S ANn CU:ANOur:: IJff!iT nf: ACCF,[J":;rnu:# Af).l'!:.rr;':,r::JT Tq .rJF: :.tAn;:: AT /.'0 C'JST TO C'f'!'Y I P(:(1r. ! of:! I JOB NO. Izona: Lot Sq. Ftg. ...- S of lot Coveraga # of Story(. Tota~ Haight -' Topography SOLAR AGISS Occu?ancl.f GJ"OU ITEM I ~tain Ir~n(l''' I ~~~~~t I SQ.FTG ACCCSG01"U TOTAL VAWE Is.D.c. Ivct.UCJ 1.5 x Building Permit State Surchcirqe Total Cha.:ogS3 lITEM I Fixtures I Residentia~ (1 bath) I Sani ta:l'"Y Sewer' I WateT' NO. FEE PlW11bing Perr.:it State Surd'.arge Total Char'ac8 I ITEM I Res. Sa. fto. III""jExtend Circuits I Temporary Service I 110, F;;;; Ele~t:rical Permit State Sur~harqe Tota~ Char~e. ITEM I PlJrna:cl! r?TU'S I ~hau8 ~ Hood' I Vent Fan I WOodsto;JC I NO, FEE Permi t Issuanca Mechanical permi t State Surcharac Total CharacG , -- ENCROACHMENT -- Ise~~ritl.f Devosit I Storage I Maintl!1Ul1Wc ' Pc1'rffit Total Chattf1D8 Curbcu"t I sidewa ~k I!) r o&j{!+f Fen::e Electrical Label ; I Mobile Homo ; I 'I I 'rrJ'rA r. AMnmlT DUE:" LOT TYPE Interior Corner Panhandle Cul-de-sac x Value CHARGE CHARGE CI/ARGE LL-' "<, I I {}, LC:; I ' . -;.. - L-COG"'" REQ,- . I Tlroe T-"pejCor.st: Bedrooms: Enel"!tu SOU'I'CeB Heat Wate:r ,lip-otero Range Fi'1'eDlace Wood:; tOV6 Lot Faces - I P.L. INorth IEnst ISouth Wast Setbacks House Carage Access. Fees 1 I 1 1 "1 1 j,' 1 1 I ' Building Value & Permit This permit io a~nted on the express condition that the said construction shaH, in al7. respects, conf.orrm to the Ordinance adopted b'y the City of Springfield, including the. Zoning Crodinance, reguLating the construaticn and uoe of buildings, and may be Guopencled or revoked at eny time upon vio- lation of any p'1'ovisions' of said Ordinances. ,. I I Plan Check Fee: I Date Paid: IReodpt H: I Signed: I Plumbing Permit No percon a~~ll construct, inotalZ, alter or change any neW 01' e:isting plumbing 01' drainage system in whole or in part, unless such person is the legal possessor of a valid plumber's license, except tr~t a pe~son may do plumbing work to property which is owned, leased or operated by the appli- cant. . , Electrical Perm it Where State La1J requires that the electrical work be done by an ELe~trical Contractor, the electrical portion of this permit ohall. roOt be vaLid untiL the label has been signed by the ELectricaL Contractor. 1 1 1 ' I Mechanical Permit , Pl.an Examiner va.. I HAVE CAREFULLY EXAMINED the compLeted application for permit, and do hereby certify that aLL information hereon is true and correct, and I further certify that any ar.d all. lJOrk pe'1'fo'mled aha'LL be do':1e in accor- dance urith the Ordinances of the City of Sproinafic7.d, and tho: Ltr..J8 of tho If State of Oregon PQrtaining to tho work described herein, and that NO OCCU- PANCY win be m:de of any structura: IJithcr,,(t permission of the Building Di- vision. I further certify that o~Ly cont~ctor8 and e:rrpz",yecs who are in compLiance with ORS 701.055 ~iLL be used on this project 'Ad!,,~ 'D~ D..ltc