HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-1-30 i( l'-"ra~;lInfoAon ",..". .To Build On . Engineering . Consulting . Testing . / ~ DAILY FIELD REPORT Date Performed: Client: January 30, 2007 Chambers Development Ms. Silva Sullivan 2295 Coburg Rd. Ste. 200 Eugene, OR 97401 Report Number: 722-70018-4 Project Name: Sports Way Business Park Phase II Springfield, Oregon Project Location: B.P. No.: Type of Inspection: 02-00818-01/C6-1357 Soils Observation Weather: Clear Field Observations and Comments A PSI representative met on site with Egge Sand and Gravel representatives to obserVe a proofroll at finished subgrade elevation for an area of parking lot and driveway on the east side of the site (see attached site plan). The proofroll was conducted using a loaded tandem axle dump truck weighing approximately 48,000 pounds. Some deflections were observed under the wheel pads and wheel tracking up to 6 inches in depth occurred indicating a soft subgrade. The area appeared over optimum moisture (wet) due to abundant roots from the trees that were there. Recommended that the driveway area only be overexcavated to allow for a minimum of 18 inches of crushed rock. The overexcavation area measured about 62' N/S by 26' E/W and the average overexcavation depth was about 4 to 6 inches. This was the last area of parkingldriveway areas that needed to be excavated. Notified Mr. Dave Krull with Chambers Construction of our observations and recommendations. Also spoke with Mr. Steve Smith with Egge Sand and Gravel regarding the use of control density fill (CD F) under the proposed column footings. Informed Mr. Smith that the CDF should meet a minimum compressive strength requirement of 100 pounds per square inch (psi) at an age of 28 days. If CDF is used, the foundation footing excavations can be excavated vertically to match the dimensions of the proposed footing and do not have to be oversized . To the best of our knowledge, the work inspected above was in accordance with the building department approved design drawings, specifications, geotechnical report and applicabe workmanship provisions of the International Building Code. Inspector: Ray Aliperti If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfully Submitted, .R fessional Service Industries, Inc. c: City of Springfield Eric Hall Architects~ Eric Hall Endex Engineering- Dave Morris Chambers Construction-- Brian Erickson Attachment: site plan THIS REPORT'/S PROV/DED FOR THE INFORMATJON OF,THE CUENT ONL Y. THE REPRODUCTION OF THIS REPORT, BY ANYMCTHOD, AND ITS TRANSMITTAL TO A THIRD O~QTY AY ANY MFAN<:; FYr':PT IN FI/Il WlTHO/1T TI-IF WBlIIEti.eEBMlS.S1O!:lJ'JESSlONAL-SEBVJCE..JN!JU~S.lSEBOJ:f1BlIE() Professional Service Indu~trles, Inc.. 1040A Shelley 51.. Springfield,'OR 97477. Phone 541/746-9649. Fax 5411746.7163 ! 1:. r\%'i .. .' '.\..... "'., '. .;.<.~~. .... ~. ..... '8' '.' ~'I'Q/;;i'! ;,' ~~... .': 1'1' . f':, ." 1 '. . ...... '<{.-'>' "\." .... . i . \. ,. . .:t ':. ....'. ..' 2#:<"(;65 ..,~ :'. <';.(~ . ::\:: 1\ '.- -r:: '70' . ~ /"1 ';':. "t'::~"(JiI:'. - \'1..:ii'~:/\'; '~/' " .....IC\JJucV,-, ~ c.-vo7 :.\.::;:\ :';"\ ,,' . '.' I J . "~~rt\" ..", . . : .~ I~ -/:~~(rof(olki ~y(>. .::J:Z";it....,:..: ,'.. '.. . ", ...~. . I. "." '." "~" . '., '. ..' : "', \. ./ . A(~C1 O\le/O-<AvqkJ ''-'.'' .::':"\~.::;.~{F:'421' Y-.h 1,J,-h<:~ otoc to :.'~l~:..>\' \.)<~. ':,::(' A soq) ,S<'\iu~. ~;,l .~@~\~~,<~\\ -!;>< .~~ 6z' tJlS h.. ~b'(.JW t~~?::C(;\:"")~/ . ..'A~ ..' .",.~:I Ii '..'~"'<' \ '(<. '"'. ~S. r:fl;-<<P 'A 28.34 f\m .~\ 'l;j1 :.~"; ~ ,~\~ .'