Loading...
HomeMy WebLinkAboutPermit Building 1993-4-6 '-.... 225 Fifth Street, Springfield, Oregon 97477 ~ . JOB NU1,lBER _9'?t::>7!z3-_ ..../ . . COMM ERCIALlI NDUSTRIAL PERMIT APPLICATION INSPECTION LINE: 726.3;'69 OFFICE: 726.3759 3,-~ ASSESSORS MAP' /7-n--:>;S-"51 IEM,'L.e. /11 A-o:' 16 U -S-,q-~--~ -_OJ':~'r(''-' . TAX LOT _--P6 ~ LOCAT;'ON OF PROPOSED WORK: OWNER: ADDRESS: -fo .8.~ p(, CITY: tl.. ..1.- \" . .' :." , / ....... DESCRIPTION OF 'WORK: Il ~ R..4:::.fr'J..fft(! ~ NEW REMODEL~ ADDITION qEMOLISH , .' M t!,,/, t; '-e. R.. .. /~C( PHONE_Lf-.i_'::1 9'0 r~ STATE: ~ Co..~ I ZIP -9-7-'-(~("l ..... OTHER _Re..Ik-(- VALU~"'? '7 de!> " NAME ADDRESS PHON~ ARCHITECT: CONST. CONTRACTOR'S NAME ADDRESS CONTRACTOR' EXPIRE%!7;//jONE GENERA' Q'cJ~~+"",,,,,,,,-~ ASS<I>L R~ l~ oz.l ~ '>''$ d~'f-(..f.. 7.. _ _b~8'g.1'ZS ^1r:: · 97,/~ ~. ..- . , AlIA- ~ _ _ , PLUMBiNG' MECHANICA' . ELECTRICAl' .. PLUMBING MECHANICAL NO FEE ' CHARGE .", "FF .'_CHARGE_.. Single Fixture Relocated Bldg. lnew Ilx. addtll Water Service Furnacel burner & venl < 100.000 BTUs Furnace/burner & vent > 100.000 BTUs fl. Floor furnace and vent Suspended wall or floor mounted unit heatel Appliance Venl separate Stationaryevap. cooler Vent Fan/Single duct Vent System apart from AC or hlg. Mechanical exhaust hood and duel It. Sanitary Sewer It. Storm Sewer '1 Baekflow Device Permit Issuance i T I I I I I 1 $10.00 , " TOTAL PERMIT TOTAL PERMIT - OFFICE USE - HANDICAP ACCESS: .... # OF BLDGS' LAND US.' # OF UNIT~' FLOOD PLAIN:_ OUAD AREA: ZONING: . OF STORIES' CONSTR. TYPF' HEAT SOURCE: LIGHTING POWER BUDGET: WATER HEATER:___ OCCY GROUP' so. FT. $/SO. FT. VALUE so. FTG MAl N SO. FTG ACCES~ x x so. FTG OTHER ;;9k-%r.U#''';;'r X TOTAL VALUE OF PROJECT ::z -=?-c:::>e' PLAN CHECK FfF RCPT' DAT" BY I I BUILDING PERMIT 15% Stale SurchalJl.e I MECHANICAL \5% State Surcharoe I PAVING' 3.8.St::' I, "7~ I PLUMBING I DEMOLITION 5% State SurcharQe FENCE VALUE $ SIDEWALK CURBCUT FT. FT. SUBTOTAL PERMITS SYSTEMS DEVELOPMENT , , " . \ j0.Y3 .'...... TOTAL RERMIT FEES EXCLUDING ELECTRICAL · REQUIRED INSPECTIONS .. ~L_~ .'-, '. It is the responsibility of the permit holder to see that aI/Inspections are made at the proper limn. To request an !:1spection, call 726.3769 (recorder), state your City designated job number, job address, type of 1nspection reauested and when y{ li '.vill be reac,:, for inspection. Requests received before 7:00 a.m. will be made the same working day. requests m~de after 7:00 ~ :'1. '.'Jill be macic the following work day. SITE INSPECTION: To be made after excavation, but prior to setup of forms. UNDERSLAB PLUMBING, ELECTRICAL, & MECHANICAL: To b'e made before any work,Js covered. ROUGH PLUMBING, ELECTRICAL & MECHANICAL: No work is to be covered until these inspections have been made and'-approved. ATTIC DRAFT STOPS & CURTAIN WALLS FOOTINGS &.FOUNDATIONS: To be made after trenches are excavated and forms are erected, all steel in place, but prior to placing concrete. " FIREPLACE: Prior to placing facing materials and before framing inspection. --- FRAMING: To be made after the roof, all framing, fire blocking and bracing are in place and all pipes, chimneys and vents are complete and the rough electrical, plumbing and mechanical are approved. CONCRETE SLAB: To be" made after all Inslab building service equIpment, conduit, piping, accessories and other ancillary equipment items are In place, but before any concrete Is placed. INSULATION & VAPOR BARRIER: To be made after all insulation and required vapor barriers are In place but before any lath or gypsum board Interior wall covering is applied. " FIRE & SEPARATION WALL: Located and constructed according to plans. UNDERGROUND: Plumbing, electrical, gas, 'sanitary sewer, storm sewer, water and' drainage lines. To be made prior to covering or filling trenches. . UNDERFLOOR: Plumbing, electrical, mechanical. To be made prior to Installation of floor Insulation, decking or floor sheathing. LATH ANDIOR GYPSUM BOARD: To be made after all lathing and gypsum board, Interior and exterIor, Is in place but before any plastering Is applied or before gypsum board joints and fasteners are taped and finished. POST & BEAM: To be made prior to Installation of floor Insulation, deckIng or floor sheathing. FLOOR INSULATION & VAPOR BARRIERS: To be made prior to Installation of decking or floor sheathing. SIDEWALK & DRIVEWAY: Required for all concrete paving within street right of way, to be made atter all excavating complete and form work and sub.base material in place. MASONRY: Steel location, bond beams grouting or verticals in accordance with UBC 2415. ROOF SHEATHING AND NAILING: Prior to Installing any roof covering. CURB AND APPROACH APRONS: After forms are erected but prior to placing concrete. PAVING: Afler U ,wel is in place but prior :0 ;Jlacing ,-::sphalt or conCI'~W, SPECIAL INSPECTIONS: h accordance Section 30G of I.he Slate S!?ccialty Coeje a special inspector shall 1'1'J employed by the bVJnerl Conlraclq: (luring construction of the follO'...,lng work. A copy of the special testin~l reports stlall be furnist1cd to the Buildi'1r, Division. STRUCTURAL CONCRETE: In excess of 2500 !:'.S.1. (306 a.1) STRUCTURAL WELDS: Performed on ,n,:; job. (2722 f) HIGH STRENGTH BOLTING: During all bo!: IJ1Slallation anc lightening OpE!!rdOrlS, (306 ~1.6) SPRAYED ON FIREPROOFING: S:a.ndards 43.8 U.B.G. SPECIAL GRAlJING, EXCAVATION AND FILLING: During earlilwori\, {306 a.11 &. Ctlapter 29} GLU.LAM BEAr'.-1S: Inspection Cenificate by ~:' approved agency. furnisl1r.;c1 to the City's Building Division before beams are plac8d. (2501 u.se. STDS. 25.10.11). )( STRUCTURAL MASONRY: 1306 <1.7) -~-fi~~ . ~/JiPL/~~~ ~~~, tn' addititn to ltlcinspec. :ions specified, '~1C Building Official may m<:lhc or require other inspection$ of any construction \-'.'ork 10 ensure compliance wi:h llle Building. City or Developnlcnt Code. FINAL PLUMBING ------------------------------------------------------- SITE PLAN REVIEW BOARD: Must be requested 2 (j;i'.'$ in advance of the date you wish inspection. All project condition~; such as landscaping, parking lot striping, etc. must be cornDI,.tcei belore requesting this inspection. FINAL ELECTRICAL FINAL BUILDING: Requested after tIle final plumbinn. (!;ectrical. mechanical and Fire Department inspections are mac:) and approved. No occupancy of the premises can be rn?o,~ until a Certificate of Occupancy has been is~ued by the Bull(iing Divisior1 and posted on the premises. FINAL MECHANICAL FINAL FIRE DEPARTMENT ADDITIONAL COMMENTS' PLANS REVIEWED ~Y DATE __ By signature, I state and agree, that I have carefully examined the completed application and do hereby certi fy lhe.; all information herein Is true and corr~ct, and I further certify that any and all work performed shall be done In accordance with :tlC Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Building Safety Division. I further certjfy that only contractors and employees who are In compliance with ORS 701.055 will be used on this project. I further agree to ensure that all required Inspections are requested at the proper time, that project address is re;l::able from tile street, that the permit card Is located at the front of the property, and the approved set of plans will remain Ol~ tile site at aJi times during constructlon_ {l;LP~ Signature I' .P,~ j -....::.. VALIDATION: AMOUNT RECEIVED' ~/?, C/5 . ~6".6 RECEIPT N' Dote _-i/-b/?'3 DATE PAID: <:L.-6-";7? RECEIVED ~Y: ~v.c-,?-_,; '7- - "-. ND-24tSS ./ U, L, CLASS A1SLOPE RANGE: 0" 10 V2" nailable decks - "" -,~ ..."",! MATERIAL REQUIRED PER 100 SQUARE FEET OF ROOF AREA Mechanical Fasteners Conbase W.l IV, 1 ply Conply A-IV, 2 plies Asphalt", plies Concoal CC-20 Emulsion. 3 gal. Conshleld Aluminum Coating, 1 gat. As Required 251bs. 221bs. 60 lbs. 241bs. a Ibs. Accessories and Flashing Materials as Required. ~AGE 56 fl..~t',,__ - '\." ~~~~~~~~~h~I*: firm, clean, dry and en. Plywood sheathing shall be supportOd on all edge. ~ and property nailed. Ply clips are nol anowed. . .cross blocking is allowed. THE CANT STRIP shall be nailed to the deck with proper length mechanical lasteners 12" o,c. CONBASE W.1 IV shall be applied at rightangles to the continuous joints of the sUllace to be rooted. Con- - base W.' IV shall be lappea 20 on sides and 60 on ends. Lap so the flow of waler is over or parallel to. but never against, the laps. Turn up 2- above top of canl on aU walls and vertical surlaces. Mechanically fasten 9 o,c. on laps and staggar two (2) rows 18" o.c. 12" distantlrom eaCh edge. Alternate: Mechafllcally IUlan wllh approved stapleltape method. Rows 01 tape shall be 12- o.c. Staplo spacing shall comply wllh manufacturer', requirements. - CONPLY A.IV shall be lapped so the flow of watar is over or parallel to, but never agalns!. me laps. All end laps shall be at least 4- and adjacent end laps shall be at least t2- apart. EMBED two (2) plies Conply A-IV in shingle fashion, lapping 19- with a \r axposure EMBED the full width of each sheet In hot asphalt applied at a nominal rate 01 30 lbs. per 100 &q. h. ot root area. Each ply shall be lightly broomed, using a mOderately soft commercial push broom, as it is applied. An piles shall be turned up 2- above tha cant and shall be solid mopped to the cenl and vertical watl. Buckles or fi,hmouths shall be cui and repaired properly. THE SURFACE to receive coating shan be clean, uniform, smOOlh and dry. Allfishmouths. buckles or dry laps shall be properly repaired prior to applying coaling. COAT THE ENTIRE SURFACE with Concoat CC-20 emulSion, applied at a nominal fale of Ihree (3) gallons per 100 sq. ft. of roof area. . ALUMINUM COATING shall be applied in stficl compliance with manufactufer's recommendations and applied al a minimum rate 01 one (1) gallon per 100 sq. It. of roof area. VALLEYS/WATERWAYS shall receive an extra layer of Conply A.IV which shan be at least 36" wide. II shall ex, , tend at least 8" up Inclines out of valleys. This ply shall be laid on top 01 base sheel prior to IIppllcallon of -, other plies. Embed the full width of eaCh ,heet in a unUorm mopping of hot asphalt appliod at a nominal rate of 30 Ibs. per 100 sq. h. Of roo! area. ON SLOPES exceeding 1.Yl" per foot hot asphalt shall be applied atl!. nominal rata of 25 Ibs, POf 100 SQ. ft. 01 rool area. All BUR shall be applied parallel to the slope 01 deCk. On slopes 2. per foot ond grealer the ply sheets shall be "back.nailed" to the deCk Of wood nailers (on insulated specifications) per the loIlowing schedule: . Ply Sheet. Nail thase Distance. From aack edge 2 18- 3 12" 4 18- Concap shall be back nailed with two (2) rows nails staggered 3- oc. OPTION: The above specillcation may be applied with cold procoss adhesive by effecting the fonowlng substitutions: 1. Substilute 3 gaUons Conhesive per 100 sq. It. vs, 30 Ibs. hot 8Spl'1alt. 2. Substitute Conbase W.1 IV as a ply sheet wherever Conply A.IV is required. . Refer 10 section 2.15, page lB, for propef melt point 01 asphalt tor slope involved. .. ALL application requirements from the "Ganeral ReQuirements" section are considefoo part of these speclficallon,.