HomeMy WebLinkAboutPermit Building 2018-01-24n 1 a I C I E F I G I H H IA N 9 EUGENE WATER & ELECTRIC BOARD 9 OREGON PROJECT LOCATION ... LOCATION MAP qQ — EUGENE, OREGON HAYDEN BRIDGE FILTRATION PLANT BASIN HANDRAIL REPLACEMENT EWEB WORK ORDER #1606280 NVICINITY MAP lw EWEB�y I. fYO�c EXPIRES: 12/31/2017 8 6 INDEX OF DRAWINGS Gi TITLE SHEET, LOCATION MAP & INDEX OF DRAWINGS G2 SITE PLAN, LEGEND & ABBREVIATIONS s Di DEMOLITION PLAN Al HANDRAIL REPLACEMENT PLAN 51 GENERAL STRUCTURAL NOTES 52 STRUCTURAL DETAILS a -2`1 I 1 I 19 I ' 3 2 a w.Irc 1eo52K WATER SYSTEMS exm.aR HAYDEN BRIDGE FILTRATION PLANTU IsNONE BASIN HANDRAIL REPLACEMENT S 10/0212017 1 TITLE SHEET, LOCATION MAP & INDEX OF DRAWINGS o D -36270—G1 uFxe. a.acu.ncmoxv.n .R:xrr.a a0 A 1 B I C I D I E 311. CONTRACTOR SHALL VERIFY LOCATIONS, DIMENSIONS, SIZES, AND CONFIGURATION OF ALL EXISTING FACILITIES & EQUIPMENT PRIOR TO THE ORDERING OR FABRICATION OF NEW FACILITIES & EQUIPMENT. CONTRACTOR SHALL NOT ASSUME THAT EXISTING STRUCTURES ARE SQUARE, PLUMB, OR LEVEL. 2. CONTRACTOR SHALL COORDINATE ALL REQUIRED CONTAINMENT & ISOLATION WORK WITH OWNER PRIOR TO START OF WORK. 2I3. IN GENERAL FOR EXISTING FACILITIES, ONLY LARGE EQUIPMENT AND STRUCTURES ARE SHOWN ON THE DRAWINGS. PRIOR TO BID, CONTRACTOR SHALL VISIT THE SITE AND INSPECT THE EXISTING FACILITIES TO DOCUMENT THE SMALLER PIPING/CONDUIT AND EQUIPMENT AND THEIR EFFECTS ON THE WORK. 4. THE CONTRACTOR SHALL RESTORE ANY EXISTING FACILITIES OR STRUCTURES THAT ARE DISTURBED. DAMAGED, OR REMOVED DURING CONSTRUCTION TO PRECONSTRUCTION CONDITIONS, I5. ISOLATION OF EACH SEDIMENTATION BASIN REQUIRES OWNER INSTALLED WATER STOPS, WHICH ALLOW A LOW WATER LEAKAGE RATE, AND THE CONTRACTOR SHALL PREVENT ALL WATER FROM AFFECTING THE WORK. NEW -- EXISTING SECTION AND DETAIL DESIGNATIONS SECTION CUT ON SECTION DESIGNATION DRAWING MI M2 DRAWING WHERE SECTION APPEARS SECTION DESIGNATION ON DWG M2 THIS SECTION IS e IDENTIFIED AS: M1 DRAWING FROM WHICH SECTION WAS TAKEN DETAILS ARE CROSS REFERENCED IN A SIMILAR MANNER EXCEPT USING LETTERS. M AL — ALUMINUM CIA - DIAMETER DWG - DRAWING EL - ELEVATION 9 / FSE - FUSION BONDED EPDXY GAL - GALVANIZED CSP - GALVANIZED STEEL PIPE HOG rl LG - LONG MAX - MAXIMUM -- - --FROM CONTRACTOR ENTRANCE HAYDEN BRIDGE ROAD MIN - MINIMUM OC - ON CENTER REINF i^ -___ --_ _ - SHEET SIM - SIMILAR BS - STAINLESS STEEL STU - STANDARD TOC - TOP OF CONCRETE TOS - TOP OF STEEL TYP - TYPICAL W/ - WITH OOTA "N'Q-t ONG, ie No err xDo A) re r, z 4 ` ; AS i PRIMARY AREA /�� rlr'r OF WORK IT I oa AS 1 i r %e '---STAGING AREA I/ I rl /I r r I 1 /r Imo_ F'A1 CN ARINGE i 4 SWITCHING STATIONS OVERALL SITE PLAN N.T.S. 311. CONTRACTOR SHALL VERIFY LOCATIONS, DIMENSIONS, SIZES, AND CONFIGURATION OF ALL EXISTING FACILITIES & EQUIPMENT PRIOR TO THE ORDERING OR FABRICATION OF NEW FACILITIES & EQUIPMENT. CONTRACTOR SHALL NOT ASSUME THAT EXISTING STRUCTURES ARE SQUARE, PLUMB, OR LEVEL. 2. CONTRACTOR SHALL COORDINATE ALL REQUIRED CONTAINMENT & ISOLATION WORK WITH OWNER PRIOR TO START OF WORK. 2I3. IN GENERAL FOR EXISTING FACILITIES, ONLY LARGE EQUIPMENT AND STRUCTURES ARE SHOWN ON THE DRAWINGS. PRIOR TO BID, CONTRACTOR SHALL VISIT THE SITE AND INSPECT THE EXISTING FACILITIES TO DOCUMENT THE SMALLER PIPING/CONDUIT AND EQUIPMENT AND THEIR EFFECTS ON THE WORK. 4. THE CONTRACTOR SHALL RESTORE ANY EXISTING FACILITIES OR STRUCTURES THAT ARE DISTURBED. DAMAGED, OR REMOVED DURING CONSTRUCTION TO PRECONSTRUCTION CONDITIONS, I5. ISOLATION OF EACH SEDIMENTATION BASIN REQUIRES OWNER INSTALLED WATER STOPS, WHICH ALLOW A LOW WATER LEAKAGE RATE, AND THE CONTRACTOR SHALL PREVENT ALL WATER FROM AFFECTING THE WORK. NEW -- EXISTING SECTION AND DETAIL DESIGNATIONS SECTION CUT ON SECTION DESIGNATION DRAWING MI M2 DRAWING WHERE SECTION APPEARS SECTION DESIGNATION ON DWG M2 THIS SECTION IS e IDENTIFIED AS: M1 DRAWING FROM WHICH SECTION WAS TAKEN DETAILS ARE CROSS REFERENCED IN A SIMILAR MANNER EXCEPT USING LETTERS. M AL — ALUMINUM CIA - DIAMETER DWG - DRAWING EL - ELEVATION EX - EXISTING FSE - FUSION BONDED EPDXY GAL - GALVANIZED CSP - GALVANIZED STEEL PIPE HOG - HOT DIPPED GALVANIZED LG - LONG MAX - MAXIMUM MB - MACHINE BOLT MIN - MINIMUM OC - ON CENTER REINF - REINFORCING BHT - SHEET SIM - SIMILAR BS - STAINLESS STEEL STU - STANDARD TOC - TOP OF CONCRETE TOS - TOP OF STEEL TYP - TYPICAL W/ - WITH e.ea waau oaoea No. m a WATER SYSTEMS Isoszeo � HAYDEN BRIDGE FILTRATION PLANT 11L, NONE aawr BASIN HANDRAIL REPLACEMENT Nlr: 3no117 E W E B o:THEN SITE PLAN, LEGEND & ABBREVIATIONS ,D X36270—G2 LINEISS WLHFS aE� D e 4 2 i] n 7 6 5 4 3 2 A B C D E F G H r K L I M N SHEET NOTES: CURB REPAIR AND PATCHING: DEMO PORTION ' I� 1) CONCRETE REPAIR AND PATCHING WORK, AS REQUIRED BY BID OF BAFFLE St WN 1�J�/] ITEM 3. 15 OWNER DIRECTED. WALL 1' L.' by 2) CONCRETE WITH VOIDS SHALL SHALL BE REPAIRED BY G z _ J REMOVING CONCRETE BACK TO COMPETENT CONCRETE. SQUARE III OFF REPAIR AREA TO A MIN. 3' DEPTH AND ROUGHEN SURFACE TO )' AMPLITUDE. TREAT ALL EXPOSED STEEL AND u ~ CONTACT ISI CONCRETE WITH 51KA ARMATEC 110 EPOCEM AND POUR NEW BASIN 2 'I ` r __ CONCRETE. DETAIL B THE DEMOLITION NOTES: ti 1J WHERE THE XPOSEDST OF STEEL 15 AGAINST CONCRETE. W '. BACK ALL EXPOSED STEEL, ED ST AND ANCHORS 3' BELOW SURFACE TREAT ALL EXPOSED STEEL ATH T RE ARMATEC 11 •. EPOCEM AND PATCH WITH QUIKRETE FASTSET REPAIR MORTAR. f I 2) DETERIORATED CONCRETE CURBS AND EXPOSED REBAR SHALL B 1 SARINS BE REPAIRED BY REMOVING CONCRETE BACK TO COPETENT BAFFLE mAu CONCRETE. SQUARE OFF REPAIR AREA TO A MIN.)' DEPTH III r�i F r AND ROUGHEN SURFACE TO 4' AMPLITUDE. TREAT ALL NEW EXPOSED STEEL WITH SIKA ARMATEC 110 EPOCEM AND POUR SHE T�z , III 4 IIT THEECONTRACTOBBISH, ANA OTHEIN R OWNERSHIP MATEROF ALL CONN DANCE NTH DETAIL 5 ON h 3) THE CONTRACTOR SHALL TAKE OWNERSHIP OF ALL CONCRETE, SAW CUT CURB FLUSH I„' REMOVE ALL NTH WALKWAY i0 CONCRETE PIER a EDGE OF OR TING. ' �a� �• (TIP.) CONN E FROM THE WORK. REMOVE ALL DEMOLISHED MATERIALS FROM CONCRETE THE SITE AND DISPOSE OF IN ACCORDANCE WITH ALL PIERS AND APPLICABLE LAWS AND REGULATIONS. VIII y VIII VIII .. �, -. RAILING I—♦ ,� 4) CONDUCT DEMOLITION AND REMOVAL WORK IN A MANNER THAT T A 7.IF WILL PREVENT THE SPREAD OF DUST AND FLYING PARTICLES. FILET 'Y E%ISIING .'BUILDING 1/I'II�lIIIII6�IIII IlIIIII!(III III / III III'YIII ///�� f4 i H w CURB NC SEE SHEdTG. ,11111 VIII I VIII VIII � . /A, l7TiPT/7'TTJ � i T/���Z CURB NOTES Iv REMOVE EXISTING II t 0TH CURB AND PLUGWATER LINE FLUSH u r LE REMOVED PIER AREA SECTION l [� I�L__IllIL�LULWl__ r,i; 1111 ;N ti !i DEMO PORTION I_ J CONTACT O BAF E St Kuo Pl I Til BASIN 1 WALL. �H L• i �' _ kW k 11111 u 1 EXISTING PLAN VIEW REVISION DESCEMON DEMO ELEVATION VIEW eCONCRETE DEMO DETAIL m1UNI S, AN. All (TTP) iWE6 W00.1(OROEA NO. �SEyEy FBQ'fdfj ul WATERSYSTEMS Isoszeo �HAYDEN BRIDGE FILTRATION PLANT EErla ARE_ 4 3 2 EXPIRES: f]/]1/20t] BASIN HANDRAIL REPLACEMENT DEMOLITION PLAN &DETAILS onre lolazam7 I EWEB xD-36270—D1 A�urvEls]INGIES LLs¢i I u: rmrz acuc+cmpmvcr, LRsxenxo n[v D 9 6 7 6 5 4 3 2 A B I C I D I E I F I f I H I I I J I K I L I M 3 N PROPOSED PLAN VIEW SHEET NOTES: 1) LADDER: a.THE LADDER SHALL INCLUDE A FIXED CAGE. AND A SELF CLOSING SWING GATE. b.THE APPROXIMATE HEIGHT OF THE LADDER IS 17'-0" (HEIGHT FROM GRADE TO TOP RUNG) & SHALL INCLUDE A 2'-11" HIGH WALK THROUGH AT THE STEP OFF ELEVATION. CONTRACTOR SHALL FIELD VERIFY THE LADDER HEIGHT AND THE EXACT LOCATION WITH THE OWNER. c,THE SELF-CLOSING SWING GATE SHALL BE LOCATED AT THE STEP OFF ELEVATION. U.ALL STRUCTURAL STEEL SHALL BE TYPE 304 STAINLESS STEEL (MILL FINISH CONSTRUCTION) AND DESIGNED PER ASCE 7-1D & RISC 14TH EDITION. ALL STRUCTURAL WELDING SHALL CONFORM TO AWS 01.1 SPECIFICATIONS. STRUCTURAL PLATFORMS LIVE LOAD -- 100 PSF ACCESS GANGWAYS LIVE LOAD - 5OOy. e.CONTRACTOR SHALL SUBMIT STAMPED DESIGN DRAWNGS. FROM THE MANUFACTURER, FOR OWNER REVIEW AND APPROVAL. THE MANUFACTURER SHALL DESIGN THE LADDER IN ACCORDANCE WITH OSHA STANDARDS. E SEE DETAIL 4 & SECTION A ON SHEET S2 FOR CONCRETE ANCHORAGE, 2) RELOCATE THE EXISTING LEVEL SENSOR ANCHORED TO THE CONCRETE CURB, LOCATED AT FILTER N1, IF SENSOR CONFLICTS WTH PROPOSED GUARDRAIL. COORDINATE RELOCATION WITH EWES. 3) THE PROPOSED GUARDRAIL SHALL BE DESIGNED AND INSTALLED TO AVOID THE EXISTING STAINLESS STEEL PIPE RISER AND HOSE VALVE ANCHORED TO THE CONCRETE WALL AS SHOWN ON PLAN. 4) EXISTING GUARDRAIL, ADJACENT TO THE PROPOSED GUARDRAIL, SHALL BE MODIFIED AT LOCATIONS WHERE CONFLICTS EXIST AND RESTORED WITH OWNER PROVIDED MODULAR ALUMINUM FITTINGS, 5) DESIGN PROPOSED GUARDRAIL SYSTEM TO AVOID CONFLICT WITH THE LOOPED RETURNS ON THE EXISTING FILTER BASIN GUARDRAILS. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR OWNER APPROVAL. 6) GUARDRAIL: O.GUARDRAIL ANCHORAGE SHALL BE INSTALLED TO AVOID JOINTS IN THE EXISTING CONCRETE. THE CONTRACTOR SHALL RESTORE THE CONCRETE CURB, IN ACCORDANCE NTH DETAIL 5 ON SHEET S2, WHERE DETERIORATED CONCRETE OR EXPOSED REBAR EXISTS. b.HANDRAIL PIPE SHALL BE A 2 -RAIL PICKET SYSTEM W/ 1-1/2" SCE. 40 RAIL & SCH, 50 POSTS, & 3" SCH- 40 PICKETS. ARCH. CLASS 1, CLEAR SATIN ANODIZED FINISH, .7 MIL (AA-M10/M12-C22-A41). 3/8" DIA. U BOLT &R 3116 X 3 X 0'-4" W/SLOT FITTING OVER U BOLT W/ COTTER PIN. 111111ON ..RN.. OWN I S D I CHK I AE PR �S �4t ur ER EWE B EXPIRES' 12/31/2017 eBAFFLE WALL DOOR Al (TYP) W DUTY HINGES. OPENING ALUM. PLATE (2), 3/B" DIP. RESIN BONDED HORS W/ 3" ED. . PER HINGE. eAl PROPOSED LADDER LOCATION (TIP) 15 11— WATER SYSTEMS P. WN 6. HAYDEN BRIDGE FILTRATION PLANT z arvoanoz BASIN HANDRAIL REPLACEMENT HANDRAIL REPLACEMENT PLAN LINE IS INCHESAT Fl 9 B SHALL HEED HE RAW HANNEL OTE 1. I 7 6 5 4 2 1606290 I"=10' 10/02I20T7 1 D -36270-A1 ..a..o. aEv 0 STRUCTURAL SHEETS: S1 GENERAL NOTES & WALL PENETRATION DETAIL S2 STRUCTURAL DETAILS GENERAL STRUCTURAL NOTES' 1. THESE NOTES ARE GENERAL IN NATURE AND ARE INTENDED TO SET MINIMUM STANDARDS FOR CONSTRUCTION. THE CONTRACTOR SHALL BE COMPLETELY FAMILIAR WITH THE CONTRACT DOCUMENTS AND HAVE A COPY OF THEM ON SHE AT ALL TIMES. 2. FOR ANY PORTION OF THE CONSTRUCTION WHICH THE CONTRACTOR IS UNABLE TO ASCERTAIN THE REQUIRED CONSTRUCTION OR WHERE CONFLICTS EXIST, IT IS THE CONTRACTOR'S RESPONSIBILITY TO REQUEST ADDRIONAL INFORMATION (RFIs) AND/OR CLARIFICATIONS BEFORE CONSTRUCTION. 3. ALL WORK SHALL BE IN STRICT CONFORMANCE WITH THE 2012 INTERNATIONAL BUILDING CODE (IBC) AS AMENDED BY THE 2014 OREGON STRUCTURAL SPECIALTY CODE (OSSC). ALL BUILDING ELEMENTS AND COMPONENTS NOT SPECIFICALLY DETAILED IN THESE STRUCTURAL CDNSTRUCTION DOCUMENTS SHALL BE FABRICATED AND CONSTRUCTED IN ACCORDANCE WITH THE MINIMUM STANDARDS CONTAINED IN THE INTERNATIONAL BUILDING CODE CODE AS AMENDED BY THE STATE OF OREGON. 4. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS BEFORE CONSTRUCTION. THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES. 5. THE CONTRACTOR, SUBCONTRACTORS AND SUPPLIERS SHALL INSURE COORDINATION OF CONTRACTOR SUPPLIED/DESIGNED ELEMENTS AND DEFERRED SUBMITTALS WITH ALL DESIGN DISCIPLINES WITHIN THE CONSTRUCTION SET. COORDINATION SHALL IDENTIFY AND RECONCILE CONFLICTS BETWEEN THE CONTRACTOR SUPPLIED/DESIGNED ELEMENTS AND THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION AND DELIVERY TO THE PROJECT SITE. THE PROJECT ENGINEER SHALL BE NOTIFIED IF CONFLICTS EXIST. 6. THE CONTRACT STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE. METHODS, PROCEDURES, AND SEQUENCE OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN AND ENSURE THE INTEGRITY OF THE STRUCTURE AT ALL STAGES OF CONSTRUCTION. 7. CONSTRUCTION LOADS SHALL NOT EXCEED THE DESIGN LIVE LOAD FOR THE STRUCTURE. PROVIDE SHORING AND/OR BRACING WHERE LOADS EXCEED DESIGN CAPACITY AND WHERE STRUCTURES HAVE NOT ATTAINED DESIGN STRENGTH. S. CLADDING, WATERPROOFING, AND ARCHITECTURAL FEATURES ARE BY OTHERS AND ARE OUTSIDE THE SCOPE OF WORK. ANY DEPICTION OF SUCH FEATURES ON THE STRUCTURAL DRAWINGS ARE NOT INTENDED TO BE USED FOR CONSTRUCTION. REPRESENTATION OF SUCH FEATURES ON THESE DRAWINGS MAY OR MAY NOT BE ACCURATE. REFER TO ARCHITECTURAL DRAWINGS AND/OR SPECIFICATIONS. DESIGN LOADS: PER 2012 IBC, 2014 OSSC. & OSHA DEAD LOAD......._..........._......____................................ SELF WEIGHT RAIL LIVE LOAD ...__.........__ ........................................ 50 PLF OR 200 LBS (ADDER LIVE LOAD ........... ..__......_....... _.... .___... _._.... 500 LBS PER ANCHOR POINT POST -INSTALLED CONCRETE ANCHORS' 1. ADHESIVE 14. ADHESIVE ANCHORS SHALL BE INSTALLED BY QUALITIES PERSONNEL TRAINED TO INSTALL ADHESIVE ANCHORS IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND WITH STRICT ADHERENCE TO THE PROVISIONS WITHIN THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS. 1.2. AT THE TIME OF ANCHOR INSTALLATION. IN ACCORDANCE WITH ACI 318-11 SECTION D.22, ADHESIVE ANCHORS SHALL BE INSTALLED IN CONCRETE HAVING A MINIMUM AGE OF 21 DAYS. 1.3. WHERE THE AUTHORITY HAVING JURISDICTION OVER THIS PROJECT REQUIRES ADHERENCE TO ACI 318-11 SECTION D.922. INSTALLATION OF ADHESIVE ANCHORS IN HORIZONTAL TO VERTICALLY OVERHEAD ORIENTATION SHALL BE DONE BY A CERTIFIED ADHESIVE ANCHOR INSTALLER (AAI) AS CERTIFIED THROUGH ACI AND IN ACCORDANCE WITH ACI 318-11 SECTION D.9.2.2. PROOF OF CURRENT CERTIFICATION SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO COMMENCEMENT OF INSTALLATION. NOTE: THE STATE OF OREGON DOES NOT REQUIRE ADHERENCE TO ACI 318-11 SECTION 0.9.2.2. SUBMITTALS: THE CONTRACTOR SHALL PROVIDE THE ENGINEER OF RECORD AND THE BUILDING OFFICIAL SUBMITTALS FOR APPROVAL , PRIOR TO CONSTRUCTION, FOR THE FOLLOWING ITEMS: 1. EPDXY ANCHORAGE 2. HANDRAIL PANEL DESIGN AND FABRICATION 3. HANDRAIL SIDE MOUNT BRACKET 4. LADDER ANCHORAGE SPECIAL INSPECTIONS: 1. AN INDEPENDENT TESTING LABORATORY CHOSEN BY THE OWNER SHALL PROVIDE SPECIAL INSPECTIONS IN ACCORDANCE WITH CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE FOR THE STRUCTURAL SYSTEMS OUTLINED HEREIN. ALL OTHER ELEMENTS SHALL COMPLY WITH THE SPECIAL INSPECTION & TESTING REQUIREMENTS OF CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE. REQUIRED SPECIAL INSPECTION OF STRUCTURAL SYSTEMS OUTLINED IN THESE CONSTRUCTION DOCUMENTS INCLUDE THE FOLLOWING AREAS OF WORK: 1.1. EPDXY ANCHORAGE 1.2. STRUCTURAL STEEL 1.3. STRUCTURAL WELDING. DOES NOT APPLY TO QUALIFIED SHOP WELDS. NOTE TO BE CONSIDERED QUALIFIED SHOP WELDS THEY MUST BE PERFORMED IN A PRE -QUALIFIED SHOP AS RECORDED BY THE JURISDICTION OF RECORD. A WRITTEN VERIFICATION OF PRE -QUALIFICATION WITH THE JURISDICTION OF RECORD IS REQUIRED PRIOR TO PERFORMING ANY STRUCTURAL WELDING IN A SHOP WITHOUT SPECIAL INSPECTION. 2. THE TESTING AGENCY SHALL PROVIDE THE ENGINEER OF RECORD, THE OWNER, AND THE BUILDING OFFICIAL COPIES OF ALL RELEVANT TEST REPORTS AND SPECIAL INSPECTIONS. HANDRAIL 1. HANDRAILS SHALL CONFORM TO THE OSSC SECTION 1013 REQUIREMENTS, INCLUDING NO OPENINGS WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER THROUGH ANY PORTION OF THE HANDRAIL 2. JOINTS SHALL BE SLIP JOINTS COORDINATED BY MANUFACTURER 3. HANDRAIL SHALL BE FABRICATED WITH GALVANIZED STEEL CONCRETE: 1. ALL CONCRETE SHALL BE HARD ROCK CONCRETE MEETING REQUIREMENTS OF ACI -301, "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS". MIX PROPORTIONS SHALL BE PER ACI -301, METHOD 2 OR THE ALTERNATE PROCEDURE. SUBMIT MIX DESIGN FOR REVIEW BY STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. 2. STRUCTURAL CONCRETE SHALL ATTAIN THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH AT 26 DAYS: TYPE fF SLUMP w/c AIR SLABS 3,000 psi 1-3" 0.40 5% 3. ALL CONCRETE EXPOSED TO WEATHER SHALL CONTAIN 59. (3) 1% AIR ENTRAINMENT BY VOLUME. AIR ENTRAINMENT SHALL BE IN CONFORMANCE WITH ASTM C260 AND C494. 4, COLD WEATHER PLACEMENT SHALL CONFORM TO ACI -306. HOT WEATHER PLACEMENT SHALL CONFORM TO ACI -305. MECHANICALLY VIBRATE ALL FORMED CONCRETE, DO NOT OVER -VIBRATE. PLACE CONCRETE MONOLITHICALLY BETWEEN CONSTRUCTION OR CONTROL JOINTS. PROTECT ALL CONCRETE FROM PREMATURE DRYING. 5. CHAMFER ALL EXTERIOR CORNERS 1/2 UNLESS SHOWN OTHERWISE. 6. SLUMP LIMITS MAY BE INCREASED BY ADDITION OF ADMIXTURES PROVIDED THAT THE WATER/CEMENT RATIO OF THE ORIGINAL MIX DESIGN IS NOT EXCEEDED. WATER REDUCING ADMIXTURE SHALL BE IN CONFORMANCE WITH ASTM494, USED IN CONFORMANCE WITH MANUFACTURER'S INSTRUCTIONS. SUBMIT ADMIXTURES TO ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION. 7. CEMENT SHALL BY TYPE I OR II IN CONFORMANCE WITH ASTM C150. AGGREGATES SHALL BE IN CONFORMANCE WITH ASTM C33. COARSE AGGREGATES SHALL NOT EXCEED n". WATER SHALL BE CLEAN AND POTABLE. & REINFORCING STEEL SHALL CONFORM TO ASTM ABLE, GRADE 60. GRADE 40 MAY BE USED FOR #3 AND SMALLER TIES AND STIRRUPS. DETAIL AND PLACE ACCORDING TO ACI MANUAL SP -66. 9. UNLESS OTHERWISE NOTED, MINIMUM COVER SHALL BE 1 1/2 FOR #5 AND SMALLER BARS, 2" FOR #6 AND LARGER BARS AND 3" WHEN POURED AGAINST EARTH. SUPPORT REINFORCEMENT WITH APPROVED CHAIRS, SPACERS, OR TIES, 10. PROVIDE MINIMUM 48 BAR DIAMETERS AT SPLICES. NO MORE THAN 507 OF REINFORCING SHALL BE SPLICED AT ANY LOCATION. UNLESS OTHERWISE NOTED, BEND ALL HORIZONTAL REINFORCING A MINIMUM OF 2'-0" AT CORNERS AND WALL/FOOTING INTERSECTIONS WITH MIN. EMBEDMENT BEYOND INTERFACE PER DEVELOPMENT LENGTH SPECIFIED IN ACI 318. 11. FORMWORK SHALL BE IN ACCORDANCE WITH ACI -347 "GUIDE TO FORMWORK FOR CONCRETE". FORMS SHALL BE DESIGNED BY THE CONTRACTOR. BRACING SHALL BE PROVIDED AS REQUIRED OR UNTIL THE CONCRETE HAS REACHED ITS SPECIFIED 28 -DAY STRENGTH, ALL SHORING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. FORMWORK, SUPPORTS, AND SHORING SHALL PROVIDE FINISHED CONCRETE SURFACES AT ALL FACES: LEVEL, PLUMB, AND TRUE TO DIMENSIONS AND ELEVATIONS SHOWN IN THE DRAWINGS. NOTICE 0 1 BAR DOES NOT MEASURE 1" DRAWING IS NOT TO SCALE TYPICAL BAFFLE WALL PENETRATION DETAIL 3/4" = l'-0" 51 3 HANDRAIL ANCHO PER DETAIL r, KE 2 52 _V -O" MA NEW HAND OTHE REQUI HAND 6" CURB B ® B O o O O o O RAGE HANDRA PER O (E) CONCRETE SLAB GUARDRAIL DETAIL n 1-1/2" PRE -FAB GUARDRAIL POST, TYP (DESIGNED BY OTHERS) (4) Y2"0 HILTI HIT RE -500 V3 PRE -FAB LADDER POST, TYR, "0 SELF TAPPING SCREWS EPDXY ANCHORS W/ 4.5" MIN (DESIGNED BY OTHERS) EMBED & 4" MIN EDGE DISTANCE PRE -FAB ALUM RAL (DESIGNEE RS TO MEET 0' REVENUE FOR RAILS) ONCRETE IL ANCHORAGE ETAIL } 2 IDE 6 WITH l 1�'J SHOWN 1.. NOTICE 0 If THIS BAR DOES NOT M_ THEN DRAWING 15 NOT DAMAGED CONCRETE CURB TO BE REMOVED AND REPLACED #4 BAR w/ HILTI HIT RE 500 V3 EPDXY. 6" MIN EMBEDMENT INTO EXISTING CONCRETE, CENTERED IN CURB W/ 12" LAP #4 HOOKS ®12"o.a. (2) MIN., W/ HILIT HR RE 500 V3 EPDXY, 6" MIN EMBEDMENT, CENTERED IN CURB , w YCRETE SLAB GUARDRAIL SECTION 1_1/2" PRE -FAB LADDER POST, (DESIGNED BY OT4 (4) Y2"0 HILTI HIT RE -500 V3 EPDXY ANCHORS W/ 4.5" MIN EMBED & 4" MIN EDGE DISTANCE Rfi"x6"x§": STAINLESS STEEL (PROVIDED BY HANDRAIL MANUFACTURER) CONCRETE CURB NOTES 1, CHIP OUT EXISTING DAMAGED CONCRETE PER EXTENTS 2. ROUGHEN EXISTING C CONCRETE SURFACE TOO Yo-• AMPLITUDE & TREAT WITHE1 EPOCEM S, POUR NEW CONCRETE CURB _DAMAGED CONCRETE VARIES DAMAGED CONCRETE —12" MIN LAPI CURB TO BE REMOVED L- AND REPLACED \\\\ 0 MIN. 6" 1 IF OCCURS IF OCCURS, CHIP CONCRETE 1 B MIN 5 PAST POST) ANCHORAGE LOCATION DAMAGED CONCRETE CURB DETAIL COORDINATE FIRST RUNG WITH FLOOR ELEVATION MAN O 4" 8" 6" NOTE: TYPICAL LADDER ANCHORAGE DETAIL APPLIES TO ANCHORAGE IMO TOP SLAB, U L (4) )g'0 HILTI HIT RE -500 V3 EPDXY ANCHORS W/ LEVELING TI-CORROSIVE PAINT ALUMINUM AND MATER WL CONTACTMINIMUM ffiR WALL SLAB, AND FLOOR SLAB NUTS, 4.5' MIN EMBED & 4" MIN 6• PRE -FAB AL MOUNT POST DIM G BOLT HOLES &IE EDGE DISTANCE TYPICAL LADDER ANCHORAGE DETAIL LADDER BASE ANCHORAGE ELEVATION s2 1 1/2J 3" 1'-0" s2 — 5"� 1/2" II _ B. GUARDRAIL ANCHORAGE DETAIL 3" = r—o" sz PRE -FAB ALUM RAL (DESIGNEE RS TO MEET 0' REVENUE FOR RAILS) ONCRETE IL ANCHORAGE ETAIL } 2 IDE 6 WITH l 1�'J SHOWN 1.. NOTICE 0 If THIS BAR DOES NOT M_ THEN DRAWING 15 NOT DAMAGED CONCRETE CURB TO BE REMOVED AND REPLACED #4 BAR w/ HILTI HIT RE 500 V3 EPDXY. 6" MIN EMBEDMENT INTO EXISTING CONCRETE, CENTERED IN CURB W/ 12" LAP #4 HOOKS ®12"o.a. (2) MIN., W/ HILIT HR RE 500 V3 EPDXY, 6" MIN EMBEDMENT, CENTERED IN CURB , w YCRETE SLAB GUARDRAIL SECTION 1_1/2" PRE -FAB LADDER POST, (DESIGNED BY OT4 (4) Y2"0 HILTI HIT RE -500 V3 EPDXY ANCHORS W/ 4.5" MIN EMBED & 4" MIN EDGE DISTANCE Rfi"x6"x§": STAINLESS STEEL (PROVIDED BY HANDRAIL MANUFACTURER) CONCRETE CURB NOTES 1, CHIP OUT EXISTING DAMAGED CONCRETE PER EXTENTS 2. ROUGHEN EXISTING C CONCRETE SURFACE TOO Yo-• AMPLITUDE & TREAT WITHE1 EPOCEM S, POUR NEW CONCRETE CURB _DAMAGED CONCRETE VARIES DAMAGED CONCRETE —12" MIN LAPI CURB TO BE REMOVED L- AND REPLACED \\\\ 0 MIN. 6" 1 IF OCCURS IF OCCURS, CHIP CONCRETE 1 B MIN 5 PAST POST) ANCHORAGE LOCATION DAMAGED CONCRETE CURB DETAIL COORDINATE FIRST RUNG WITH FLOOR ELEVATION MAN 1-1/2 1'-0" #4 BAR w/ HILTI HIT RE 500 _V3 EPDXY. 6" MIN EMBEDMENT INTO EXISTING CONCRETE, CENTERED IN CURB w/ 12" LAP MATCH EXISTING MATCH EXISTING t, 4 HOOKS ®12"o.c., (2) MIN., W/ HILR HIT RE 500 V3 EPDXY, 6" MIN EMBEDMENT, CENTERED IN CURB SECTION B -B 1" 4" 1" NOTE: TYPICAL LADDER ANCHORAGE DETAIL APPLIES TO ANCHORAGE IMO TOP SLAB, U L (4) )g'0 HILTI HIT RE -500 V3 EPDXY ANCHORS W/ LEVELING WALL SLAB, AND FLOOR SLAB NUTS, 4.5' MIN EMBED & 4" MIN 6• EDGE DISTANCE TYPICAL LADDER ANCHORAGE DETAIL LADDER BASE ANCHORAGE ELEVATION s2 3" 1'-0" s2 1-1/2 1'-0" #4 BAR w/ HILTI HIT RE 500 _V3 EPDXY. 6" MIN EMBEDMENT INTO EXISTING CONCRETE, CENTERED IN CURB w/ 12" LAP MATCH EXISTING MATCH EXISTING t, 4 HOOKS ®12"o.c., (2) MIN., W/ HILR HIT RE 500 V3 EPDXY, 6" MIN EMBEDMENT, CENTERED IN CURB SECTION B -B