HomeMy WebLinkAboutPermit Building 2017-05-04r
I
I EXTG 4" WATERLIIIE
TO riE ABANOONEQ i
CONT. FACTOR TO
COORDINATE WITH SUB i
I
10' PUE I
I
I
I s
3
`4�kp0
15
16
10.00'
PU
l�
CURVE TABLE
CURVE RADIUS DELTA ARC DIST. CHORD GEARING CHORD DIST,
C10 1402.39' 4'39'44" 114.11' N 76'02'41" W 114.08'
C32 65.00' 23'06'00" 26.21' N 46'3511 W 26.03'
00 moo_ �
L6
CO o
00 1_3
04-
OIN 0
CNO
Z
38.00 b m a, C W
5' _ REQ'D o 71 ' OO
= 'U r REQ'D— N
b � y .0 O
y o
a o
oO�O�Cj
5�1b Q° ♦ ° `N89059'32"E 76.28' f
LOT 15
HAYDEN HOMES
2464 SW GLACIER PLACE, SUITE 110
REDMOND, OR 97756
' (541) 923-6607
8,709 SQ. FT.
BUILDING SETBACKS
FRONT (BUILDING) 10' (FROM PL)
FRONT (GARAGE) 18' (FROM SW)
CORNER 10' (FROM PL)
REAR 10' (FROM PL)
SIDE 5' (FROM PL)
LOT 15
4740 GLACIER MEADOWS LP
GLACIER MEADOWS
SPRINGFIELD, OREGON
DATE RECEIVED: 4/3/2017 JOB No. S17-00765
ZONE: LDR OCCUPANCYGROUP: R3/U
UN T(R); 1 OCCUPANCY LOA
STORIES: I TYPE CONSTRUCTION: VB
LEGAL DESCRIPTION: 19-02-05-Q/13400
ADDRES
--
ADDRESS: 4740 Glacier Meadows Loop
OWNER: Hayden Homes
THE CONTENTS HERE ON HAVE BEEN REVIEWED, WITH ALTERATIONS
T41DICAT€D IN RM CHANGES OR ALTERATIONS MADE TO THE APPROVED
DRAWINGS OR PROJECT AFTER THE DATE BELOW SHALL BE APPROVED BY THE
BUILDING OFFICIAL.
CITY OFSPRINGFI ,,DREG �,'
APPROVED BY-
NOTICE: This permit shall expire if the work authorized under
this permit is not commenced or is abandoned for any 180 day
period.
ATTENTION: Oregon law requires you to follow rules adopted by the
Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-0010 through 952-001-0090. You may obtain copies of the
rules by calling the center. (Note: The administrative telephone
number for the Oregon Utility Notification Center is (800)332-2344.
Construct sidewalk per City Standard 3-12.
New street trees shall be at least 2 inches in caliper.
Street trees shall be selected from the City Street Tree
List and installed as specified in the City's Engineering
Design Standards and Procedures Manual
Construct driveway per City Standard 3-21. Maximum
width 24 feet. No above -ground facilities (fire hydrants,
power poles, catch basins, valves, j -boxes, etc.) shall
be permitted within the apron or ramp area.
Connect Sanitary Sewer to 6" service connection. Field verify
location.
Connect Storm Sewer to weephole(s) in curb per City
Standard 3-6. Pipe constructed within Right -of -Way
must be perpendicular to Right -of -Way.
All measurements are from Property lines
-Front Yard to House 10 feet
-Front Yard to Garage 18 feet
-Side Yard to House or Garage 5 feet
-Rear Yard to House or Garage 10 feet
P.U.E. MAY CHANGE SETBACKS