HomeMy WebLinkAboutOccupancy Correspondence 1978-2-23 ~". .,.-0;. ., .- CITY OF SPRINGFIELD SPRINGFIELD, OREGON 97477 DEPARTMENT OF PUBLIC WORKS February 23, 1978 ,346 MAIN STREET 726-3753 Mr. Barnie L. McCaskill 2570 Quebec Street Eugene, Oregon 97401 RE:' O~cupancy Inspection At Southwest Corner of City Center Market Building, 660 Main Street Dear Mr. McCaskill: On Wednesday February 15, 1978, the Building Division performed an inspection of the City Center Market Building, an area formerly used as a commercial lease space. This inspection has revealed the following items which require correction or re- vision prior to occupancy of the space. 1. When the opening was cut into the brick wall fronting on Main Street, several courses of brick were left at the top of the opening which are not adequately supported. Removal of these brick,up to the existing lintel above is required~ or provide a new steel or concrete lintel ot support the brick above the opening. The Building Code does not allow wood to be used for masonry support, 2, Submit a plan, for approval by the Building Division, of the proposed store- front to ee constructed on the Main Street frontage including materials to be used, sizes of openings, etc, Glazing materials in storefront doors and windows within 48" of door sides must be of safety glass. 3. Remove all of the wood shavings which were previously used as insulation for the cooler as they present an extreme fire hazard. Replace this material with an approved fiberglass or mineral wood type non-combustible insulation where required. . 4. Remove the existing floor joist system to lower the floor level of the space for access from the Main Street sidewalk. O1anges in level must be by ramps not exceeding 1 in 10 slope, 5. Prior to occupancy of this space, it must be re-wired to provide electrical service as required by the National Electrical Code for the use intended, Verify these requirements with the City Electrical Inspector when an occupancy type has been determined. 6. Indicate means of heating this space, Obtain necessary permits if installation of mechanical equipment is intended. 7. Restroom facilities must be available in the building for occupants of this space. Indicate what facilities are available, and where they are located. , __J .. .~ Page 2. Occupancy Inspection If you have any questions regarding the above items, please contact the Building Division, at 726-3753. Sincerely, a ' 1.J/ ~u<J 0, ,~~a? Lorne W. Pl eger Plans Examiner , LWP/ct