Loading...
HomeMy WebLinkAboutOccupancy Correspondence 1991-6-17 (2) ~ . .. . S.GFIELD t- __-_,. _ ;;s.:;~~ Nfi'l!.C);t::.'1;J;/ I.tl~ I ~~ ~~'J;/ =icf.G) .'~~~~ f'lcl/c1oo"C"TSCO\'/,",c" ~,.... ~ ~",= ._~.., "J~,n".., _.... __ .II....i't" _II ........... _ .. ...~ ~ PUBLIC WORKS ' SPRINGFfEI.D OR 97~77 METROPOLITAN WASTEWATER MANAGEMENT (5021 726.:;753 CERTIFIED LEYrER June 17, 1991 Da\'id Gibson 761 W. N Street Springfield, OR . 97477 SUBJECT: Occupancy Inspection at 630 Main Street, Springfield, Oregon "* Dear Mr. Gibson: At your request, the Springfield Building Safety Division conducted an inspection of the building at the above address for. the proposed use as a movie theater. Based on the proposed occupancy, the existing conditions \\'hich are mentioned below do not meet the minimum Building Safety Code requirements. Correcth'e measures must be taken prior to occupancy to install, repair, replace or modify the following items in order for the building to conform to appliCllble safety codes. STRUCTURAL 1. Emergency exit lighting will be required at all exits from the theater area. 2. Stairs ha\'ing more than two risers and which are wider than 44" shall have handrails on both sides of the stairway. Handrails shall be placed not less than 34" nor more than 38" above the line of nosings of the treads and shall be continuous the full length of the stairs. Ends shall be returned to the wall or terminate at a post. Open stair railings shall have intermediate rails not greater than 6" apart. The handgrip portion of the rail shall be not Jess than 1 1/2" nor more than 2" in cross-section or the shape shall provide an equivalent gripping surface. A minimum clearance of not less than I 1/2 shall be pro,'ided between the handrail and the wall. 3. A sign reading "Safety Film Only Pen/lined in This Room" ~hall be posted on the outside of each-projection room door unci in a con~pku(;us l(';:.dti(,n wilhin the ~rujl"<.:liun roura. PLUMBING 4. Toilets in public restrooms shall be prO\'ided with open front toilet seats. ." , ,.:.\ . . Da\'id Gibson/Occupancy Inspection 630 Main Street Page 2 5. The discharge from the water heater temperature pressure relief \'al\'e shall be extended directly to the exterior of the building using appro\'ed materials of the same size as the \'al\'e outlet and shall terminate at a location that will a\'oid ha7.ard to persons and property at a point within 6" to 24" of the ground. MECHAA'lCAL 6. A sen'ice report on the maintenance of the existing mechanical system shall be performed by a licensed mechanical contractor. ELECTRICAL 7. Broken or missing co\'er plates were noted on electrical outlets, switches and/or junction boxes \\'hich require replacement to reduce the possibility of electrical shock or fire. 8. The integrity of the electrical cable insulation shall be checked with a "Megger" as described in the National Electrical Code, 550-12a. 9. The quality of the circuit breakers may ha\'e deteriorated o\'er the )'ears. It is our recommendation they be replaced with new breakers in new panels. 10. All circuit breakers in the electrical panel shall be properly labeled. 11. Circuit breakers used as s\\itches shall be appropriately labeled. 12. All lighting and similar electrical fixtures shall be adequately secured. Building permits must be obtained for the abo\'e items which in\'ol\'e repairs or modifications to the structural, electrical, plumbing or mechanical s)'stems of the building and for any additions or re\'isions you wish to make to the building. An Oregon licensed electrical contractor is required for all new work and substantial alterations to existing electrical s)'stems. If )'ou have any questions or need clarification of the abo\'e requirements, please contact the Building Safety Dh'ision at 726-3759. Sincerely, < (71''' f)\ry ~om Marx Building Inspector , , ' /), . /t-1.~'n l,,/....c.---~,-~ Chris Christensen Electrical Inspector CC: Da\'e Puent, Building Official Mike Hudman, Fire Marshal