HomeMy WebLinkAboutOccupancy Correspondence 1997-7-22 , , ;'" " '\'1 ....~.., ~. ...-1 . . DEVELOPMENT SERVICES DEPARTMENT 225 FIFTH STREET SPRINGFIELD, OR 97477 (541) 726-3753 FAX (541) 726-3689 July 22, 1997 Will Myers 36668 Camp Creek Rd. Springfield, OR 97478 Subject: Occupancy Inspection at 630 Main Street, Springfield, Oregon. * Proposed Use: Assembly Use - Private Dancing Facility Dear Mr. Myers, At your request, the Community Services Division/Building Safety conducted an inspection of the building located at the above address on June 13, 1997. The purpose of the inspection was to determine the suitability of the building for the proposed use as indicated. Based on the proposed occupancy, the existing conditions which are mentioned below do not meet the minimum Building Safety Code requirements. Corrective measures must be taken prior to occupancy to install, repair, replace or modify the following items in order for the building to conform to applicable safety codes: ' STR TTc;TT IR :i.L I. All emergency exit lighting shall be operationaL 2. Currently there is a 14 inch step at the northeast exitway. The maximum allowable step-height for an exitway is seven inches_ Stairs or a ramp must be installed in its place. fl.TTMRlOO 1, The shower in the men's rest room has been installed without the required permits or inspection approvals, Please purchase a plumbing permit and obtain inspection approvals or remove the shower. ELECTRICAL I, There have been lighting fixtures and other wiring installed by the previous tenants without permits or inspections, In the attic area there are uncovered junction boxes and areas with exposed wiring that needs to be repaired, It is recommended that you ../ ~. . . Occupancy Inspection July 22, 1997 Page 2 have a licensed electrical contractor make the needed repairs and check the integrity of the rest of the electrical system. All electrical installations, alterations or modifications shall conform to present Electrical Specialty Safety Code requirements. Building permits must be obtained for the above items which involve repairs or modifications to the structural, electrical, plwnbing or mechanical systems of the building and for any additions or revisions you wish to make to the building. If you need any further information or have any questions regarding the above requirements, please contact me between the hours of 8:00-9:00 a,m., 1 :00-2:00 p,m, or 4:00-4:30 p.m. at 726-3759. Sincerely, ~'111~/fJL Tom Marx Building Inspector :J)~.j_.. ,I: /I;L Dave Gadomsld ~ Electrical Inspector cc: Dave Puent, Community Services Manager/Building Official Lisa Hopper, Building Safety Coordinator