CERTIFIED LEITER
June 17, 1991
Dal'id Gibson
761 W. N Street
Springfield,OR 97477
*
SUBJECT:
Occupancy Inspection at 630 '\fain Steeer, Springfield, Oregon
Dear Mr. Gibson:
A< ,.", "'o~', <h, S,d"n,,, Bondi" Sof", 0;"1;'" ",',,'" " ''''tt'''' ,r <h, boildi"
at the above address for the proposed use as a mOl'ie ihealer.
B:iSed on the proposed occupancy, lhe existing conditions which are menlione,d below do not meet
the minimum(Building Safety Code requirements. Correctil'e mC;]Sures must be taken prior to
occupancy to )nstall, repair, replace Or mOdify the fOllOwing items in order for the building to
conform to applicable safety codes.
STRUCTURAL
1. Emergency exit lighting will be required at all exits from the theater area.
2. S.'" h".'" moo, <h" h" ,','" ,,' whid> '" "id~ <h" 44" ,h'l/ h,,', h"'m'. "
both sides of the stairway. Handrails shall be placed not less than 34" nor more than 38"
abol'e the line of nosings of the treads and shall be continuous lhe full length of the stairs.
Ends shall be returned to the wall Or terminate at a post. Open stair railings shall hal'e
intermediate rails not greater than 6" apart. The handgrip portion of the rail shall be not
less than 11/2" nor more than 2" in cross-seclion or the shape shall prol'ide an equil'alent
gripping surface. A minimum clearance of.nol less than 11/2 shall be prOl'ided between the
hal)drail and the w31l.
2. A"" '" di" "S'k. FiI', 0,(, P 'n, 'mil " "i, Roo.' .' h,!1 b, po"" " ,', """ id, "
each projection rOOm door "or. ;:; :: cO";P;(u;'~s :('(:d:;\"l wil!lin :b~ ~n:Jl'Cliur. rou:;;.
PLUMBING
4. Toilers in public restroonJs shall be pnll'jdrd with open front toilet seats.
~,... ::l....".
'. ~.., ....... .
,
.
"
..
David Gibson/Occupancy rn~pt'Clion
630 ~fain Street
Page 2
5. The discharge from the water healer temperature pressure relief valve shall be extended
directly to the exlerior of the building using approl'ed materials of the same size as the "all'e
outlet and shall terminate at a location thJt will avoid hazard to persons and properly at a
point within 6" to 24" of lhe ground.
MECHANICAL
6. A service report on the maintenance of the existing mechanical system shall be performed
by a licensed mechanical contractor.
ELECTRICAL
7. Broken or missing cover plates were noled on electrical outlets, switches and/or junction
boxes which require replacement to reduce the possibilily of electrical shock or lire.
8. The integrity of the electrical cable insulation shall be checked with a "Megger" as described
in the National Electrical Code, 550-12a.
9. The quality of the circuit breakers may hal'e deterioraled ol'er the )'ears. It is our
rf1Commendalion they be replaced wilh new breakers in new panels.
,
i ,
10. All circuil breakers in the eleclrical panel shall be properly labeled.
II. Circuit breakers used as swilches shall be approprialely labeled.
12. All lighting and similar electricallixtures shall be adequately secured.
Building permits must be obtained for the above items which invoh'e repairs or modilications to the
structural, electrical, plumbing or mechanical systems of lhe building and for any additions or
revisions you wish to make to the building.
An Oregon licensed electrical contractor is required for all new work and substantial alteralions to
existing electrical systems.
If ypu have any questions or need c1arilication of lhe abo"e requirements, please contact the
Building Safety Division at 726-3759.
Sincerely,
.-1" fJL. r-
"-~ (J'1VI ~
Tom Marx
Building Inspector
, , . /"),
"t~-Z'l1 Vk;..~uu_,
Chris Christensen
Electrical Inspector
CC: Da,'e Puent, Building Official
Mike Hudman, Fire !\farshal