Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-12-18 Field Observations and Comments 'Performed visual inspection of reinforcing steel in the following locations: 8" CMU and 6" CMU for Quick Lube Building 8' from top of footing, 4' lift. Reinforcing steel was checked for grade" size. lap, placement and clearances where applicable. Reinforcing steel was placed in accordance with approved design drawings and specifications. All cells were relatively clean and mortar projections are within the limits of the International Building Code. Performed continuous inspection during the placement of grout in the locations listed above. Grout was placed by pump and mechanically/manually consolidated. All cells were grouted solid. To the best of our knowledge, the work inspected above was in accordance with the building department approved design drawings. specifications and applicable workmanship provisions of the International Building Code. Contractor was advised of all on-site results and asked to notify our office when additional services are needed. Tvoe of Material J:irQ.ut Supplier Morse Bros Mix # 247KG3ROOO Slump 8" Air Content Ambient Temperature Material Temperature Time Placed Design Strength (psi) Number of Samples Total Yardage Placed Inspector: Jennifer Tran, ICC #5282553-84 1"~;lIrifo,ltion ",~. .To Build On Engineering . Consulting. 7lIstlng . DAILY FIELD REPORT Date Performed: December 18, 2006 Report Number: 722-60359-36 Client: Mr. Eric Patterson Project Name: Lith ia Toyota - Lithia Toyota Quick Lube 360 East Jackson Street Project Location: 863 Main Street Medford, Oregon 97501 Springfield. Oregon P.O. No.: Permit No.: COM 06-0868 Type of Structure: Weather: Clear Type of Inspection: Structural Masonry 48" 1:05PM 2500 6 yds If you have any questions regarding this report. please feel free to contact us at 541-746-9649, Respectfully Submitted, Profess nal Service Industries, Inc. (:r J er ran Department Manager c: City of Springfield John Hyland Construction Doug Snider Architect /' THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE eVENT ONt Y. THE REPRODUCTION OF THIS REPORT, BY ANY METHOD. AND fTS TRANSMfITAL 10 A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES, IS PROHIBITED. Professional Service Industries, lnc,. 1040A Shelley 81.. Springfield, OR 97477. Phone 541n46-9649. Fax 541n46-7163