HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-12-29
l"~;lInformation
,.,~. .ToBuildOn
~, '.. ~. n-ting
Mr. Eric Patterson
Lithia Toyota
360 East Jackson Street
Medford, Oregon 97501
Client:
Address:
-
SPRINGFIELD OFFICE
COMPRESSION REPORT
Project No.: 722-60359-22
Proj. Name: Lithia Toyote - Building Addition
Location: 863 Main Street
Springfield, Oregon
1040 - A Shelley Street
Springfield, Oregon 97477
(541)746-9649 - (541)746-7163 fax
December 29. 2006
COM 2006-01171
Date:
B.P. No.:
P.O. No.:
Cast By:
Michael Wright
Yardage
Field Test Data
Slump (in.): ASTM C143 3"
Max. Aggr. Size: 3/4"
Air Content: A$TM C231
lIir Temperature (F): 38,2
Material Temp. (F): ASTM C1064 62.4
Max Temp (F):
Min Temp (F):
Specimen Size: 6x12
Unit Weight (pet): ASTM C138
Time Cast: 12:45.PM Curing Conditions:
Additives:
Results Reported To: Lead Worker
ASTM C31
Placement Data: Material: Concrete
Footin9 addition, North and South footin9s 213 of West footing. North end.
Location Sampled At:
Northwest corner.
Oate Cast: 11128106
Ti;~~~~.~ 1~:3~~:150VO
Desi~l" Strenqth (psil:
Cylinder No. Test Date
06-3565 121512006
06-3566 1212612006
06-3567 1212612006
06.3568 Hold
Date Rec'd:
Weather:
11/29/06
Cloudy
required 3,000
Age (days) Field Cure
(days)
7
28
28
Hold 1
Lab Cure
(days)
koad:
Total:
Supplier:
Morse Bros.
.
1
14
Compressive Strength Data ASTM C39
placed 3.000
Diameter or Cross Sect. Area Cylinder WT. Compo Strength Capping Method
Dimensions (5.1.) (Ibs,) Max. Load (Ibs.) (psi) Fracture Type .. Test Time
(Inches) C617~J C1231-Q3
6.00 28,27 28,2 67.200 2.370 5 9:17 AM ~
6,00 28,27 28,3 113.490 4,010 5 10:12AM
6.00 28.27 28.2 109,590 3,880 5 10:25 AM X
6
27
27
Hold
J - Columnar 4. Diagonal wino craking at ends 5 - Side fractures (al top of bottom) 6. Top fractures (same as #5 but end of cylinder is pointed)
'Respectfully Submitted, ,
Prof, rtional ~dustries, Inc.
J JA/v 1:
Sleven E. Wilder
Laboratory Supervisor
.. 1 . Cone (both ends) 2. ConeNertical Cracks (one end)
Remarks:
c: City of Springfield
John Hyland Construction
Doug Snider Architect
THIS REPORT IS PROVIDED FOR THE INFOR~fA TlON OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT BY ANY METHOD, AND ITS TRANSMITTAL TO A THIRD PARTY BY ANY MEANS EXCEPT IN FULL, IS
PROHIBITED WITHOUT THE WRITTEN