HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-1-31 (3)
l.. ~ _lIn/ormation
,.,~. .ToBuildOn
I/!!ng. ., 'r19 . ~ . n..ung
Client:
Address:
Placement Data:
Floor Slab
Mr. Eric Patterson
Lithia Toyota
360 East Jackson Street
Medford. Oregon 97501
Location Sampled At:
SE Corner
Date Cast:
Ticket No.:
2777766
01122107
I ~i::S~:E5200
Date Rec'd: 01123/07
Weather:
Clear
Design Strength (psi):
Cylinder No.
07.0201
07-0202
07-0203
07-0204
COMPRESSION REPORT
*
Project No.: 722-60359-54
Proj. Name: Lithia Toyota - Building Addition
863 Main Street
Date:
B.P. No.:
P.O. No.:
Cast By:
Location:
Springfield.
Field Test Data
Material: Concrete
Slump (in.): ASTM Cf43
Max. Aggr. Size:
Air Content: ASTM C231
6"
314
33.0
61.
koad:
Total:
Supplier:
Morse Bros.
Air Temperature (F):
Material Temp. (F): ASTM C1064
Max Temp (F):
Min Temp (f):
Specimen Size:
Unit Weight (pet): ASTM C138
Time Cast: 8: 15 AM Curing Conditions:
Additives: non chlorine accelerator
Results Reported To: Contractor
Yardage
6x12
3
150
reQuired 4.500
Compressive Strength Data ASTM C39
placed 4,500
Test Date
Field Cure
(days)
Age (days)
1129/2007
2119/2007
2/19/2007
Hold
7
28
28
Hold
u 1 - Cone (bLih ends) 2 - ConeNertical Cracks (one end)
Remarks: Set #1
c: City of Springfield
John Hyland Construction
Doug Snider Architect
Morse Bras
/'
SPRINGFIELD OFfiCE
1040 - A Shelley Street
Springfield, Oregon 97477
(541)746-9649 - (541)746-7163 fax
January 31,2007
COM 2006-01171
M. Wright
.
ASTM C31
lab Cure Diameter or Cross Sect. Cylinder WT. Camp. Strength Capping Method
Dimensions Max. load (Ibs.) Fracture Type .. Test Time
(days) (inches) Area (s.i.) (Ibs.) (psi)
C617.o3 C1231.o3
6 6.01 28,37 28,5 116.230 4,100 5 11:49PM ~
27 6,00 28.27 28.5 154.055 5.410 3 9:30 AM
27 6,00 28,27 28.5 149,455 5,270 3 9:56 AM X
Hold
J - Columnar 4. Diagonal wIno craking at ends 5 - Side fractures (at top of bottom) 6. Top fractures (same as #5 but end of cylinder is pointed)
Resfectfully Submitted,
pr; ,!f~ces Industries, Inc.
Steven E. Wilder
Laboratory Supervisor
THIS REPORT IS PROVIDED FOR THE INFORJ.fATlON OF THE CLIENT ONL Y. THE REPRODUCTION OF THIS REPORT BY ANY METHOD. AND ITS TRANSMITTAL TO A THIRD PARTY BY ANY MEANS EXCEPT IN FULL. IS
PROHIBITED WITHOUT THE WRITTEN
PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES.