Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2007-2-8 .,llt:- .0 rti~. 11jOnrultzon I",..,. .To Build On Engineering . Consulting . Jesting . DAILY FIELD REPORT Date Performed: February 8, 2007 Report Number: 722-60359-58 Client: Mr. Eric Patterson Project Name: Lithia Toyota - Lithia Toyota Quick Lube 360 East Jackson Street Project Location: 863 Main Street Medford, Ore90n 97501 Springfield, Oregon P,O, No.: Permit No.: COM 06-0868 Type of Structure: Weather: Overcast Type of Inspection: Structural Masonry /' Field Observations and Comments Performed visual inspection of reinforcing steel and wall anchors in the following locations: 8" CMU exterior wall to shop addition 16' to 20' 8". Reinforcing steel was checked for grade, size, lap, placement and clearances where applicable. Reinforcing steel was placed in accordance with approved design drawings and specifications, All cells were relatively clean and mortar projections are within the limits of the International Building Code. Performed continuous inspection during the placement of grout in the locations listed above. Grout was placed by pump and mechanically consolidated. All cells were grouted solid. Cast 1 set of 3 (3x3x6) grout test samples. To the best of our knowledge, the work inspected above was in accordance with the building department approved design drawings, specifications and applicable workmanship provisions of the International Building Code. Contractor was advised of all on-site results and asked to notify our office'when additional services are needed. Tvoe of Material Grout Supplier ES&G Mix # 17 Slump 81/2" Air Content Ambient Temperature Material Temperature Time Placed Design Strength (psi) Number of Samples Total YardaFe Placed Inspector: David Smith, ICC# 0877340-84 48' 61' 10:30 AM 2500 3(3x3x6) 20.0 yds If you have any questions regarding this report, please feel free to contact us at 541-746-9649. Respectfully Submitted, Professional Service Industries, Inc, ~?/t:=--- ennl er Tran Dep rtment Manager c: City of Springfield John Hyland Construction Doug Snider Architect THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONLY. THE REPRODUCTION OF THIS REPORT. BY ANY METHOD. AND ITS TRANSMITTAL TO A THIRD PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES. IS PROHIBITED Professional Service Industries, Inc.. 1040.A Shelley Street- Springfield, OR 97477. Phone 541n46.9649. Fax 541046.7163