DAILY FIELD REPORT
Date Performed: February 8, 2007 Report Number: 722-60359-58
Client: Mr. Eric Patterson Project Name: Lithia Toyota -
Lithia Toyota Quick Lube
360 East Jackson Street Project Location: 863 Main Street
Medford, Ore90n 97501 Springfield, Oregon
P,O, No.: Permit No.: COM 06-0868
Type of Structure: Weather: Overcast
Type of Inspection: Structural Masonry
/'
Field Observations and Comments
Performed visual inspection of reinforcing steel and wall anchors in the following locations: 8" CMU exterior wall to
shop addition 16' to 20' 8". Reinforcing steel was checked for grade, size, lap, placement and clearances where
applicable. Reinforcing steel was placed in accordance with approved design drawings and specifications, All cells
were relatively clean and mortar projections are within the limits of the International Building Code. Performed
continuous inspection during the placement of grout in the locations listed above. Grout was placed by pump and
mechanically consolidated. All cells were grouted solid. Cast 1 set of 3 (3x3x6) grout test samples. To the best of
our knowledge, the work inspected above was in accordance with the building department approved design drawings,
specifications and applicable workmanship provisions of the International Building Code. Contractor was advised of
all on-site results and asked to notify our office'when additional services are needed.
Tvoe of Material Grout
Supplier ES&G
Mix # 17
Slump 81/2"
Air Content
Ambient Temperature
Material Temperature
Time Placed
Design Strength (psi)
Number of Samples
Total YardaFe Placed
Inspector: David Smith, ICC# 0877340-84
48'
61'
10:30 AM
2500
3(3x3x6)
20.0 yds
If you have any questions regarding this report, please feel free to contact us at 541-746-9649.
Respectfully Submitted,
Professional Service Industries, Inc,
~?/t:=---
ennl er Tran
Dep rtment Manager
c: City of Springfield
John Hyland Construction
Doug Snider Architect
THIS REPORT IS PROVIDED FOR THE INFORMATION OF THE CLIENT ONLY. THE REPRODUCTION OF THIS REPORT. BY ANY METHOD. AND ITS TRANSMITTAL TO A THIRD
PARTY, BY ANY MEANS, EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF PROFESSIONAL SERVICE INDUSTRIES. IS PROHIBITED
Professional Service Industries, Inc.. 1040.A Shelley Street- Springfield, OR 97477. Phone 541n46.9649. Fax 541046.7163