HomeMy WebLinkAboutOccupancy Correspondence 1984-9-5 CIT~ OF SPRINGFIELD ~ Dep.rtment of Public Works Building Safety Division 225 North 5th Street Springfield, Oregon 97477 I 726-3753 (Bus.) 726-3769 (Insp.) !-e ' . OCCUPfu~CY INSPECTION APPLICATION DATE: September 5, 1984 11 , JOB ADDRESS: 727 Main street ~,. V OWNER: .T~m"" R. Pelliri O\VNERS ADDRESS: ,62~q Pe"l Lane. Sufd. APPLICANT: <if 'fOIo<.{ Co SPRINGFIELD ~~",: ... I ,. - /" ',r APPLICANTS ADDRESS: 220 Eost ,6th Ave. EU~ene Art and Ruth Wat.ters (ar<ent: call Hollie Korinek - Accredited BrokE:" Real Estate r FOR ACCESS TO PROPERTY--PLEASE INCLUDE TELEPHONE NUMBER: 741-1625 PROPOSED USE: Beautv Colle~e (Confidential) A $30.00 INSPECTION FEE IS REQUIRED AT THE TIME OF APPLICATION .THIS APPLICATION FORM MUST BE SIGNED BY THE OvmER OF THE PROPERTY TO BE INSPECTED. w~'Jf{}&t& ~TUP~~~ROPERTY OvVNER FOR OFFICE USE ONLY' I --------------------------------------------------------------------------- , I I I DATE OF INSPECTION: DATE OF REPORT: DATE OF CERTIFICATE OF COMPLIANCE: COMMENTS: RECEIPT NUMBER: DATE PAID: I I . '2.. . . . l . . .r' I FORMER ELKS HALL ELECTRICAL DING LIST NORTH EAST FOOD STORAGE AREA' North wall, Install approved cover on three gang box. I , East wall north side, Attach box and conduit. COOKING AREA North wall, Terminate open wires in wall by an approved method. , Replace wiring at water: heater using an approved wiring method. i EAST HALL North wall, install cover on receptacle. West wall, Install lense on light fixture. SOUTHEAST ENTRY North wall, install plate on switch. SOUTHEAST UTILITY AREA Install plate on receptacle at telephone equipment. Strap 1" conduit going ~o water heater. LARGE CENTER AREA Install box extensions on all receptacles in paneled walls. UNDER STAIRS Strap or remove condui t'. FOYER i Repair or reeplace wall, heater. Lense on 4'flourescent fixture? . . . . . . ,/ SECOND FLOOR NORTH "BALCONY" AREA , Relocate or remove receptacle that is located above baseboard heater on east wall. BALCONY HALL , Strap conduit feeding south wall receptacle. SECOND FLOOR AUDITORIUM I , "i Properly strap conduit between main lights. Install cover plate on electrical box north wall behind stage. ; Remove rubber cord and ~ewire main lights at south end of auditorium using approved wiring methods. Properly strap conduit 10cated in closet areas in south wall. Remove or repair broken fixtures behind bar. NORTH STAIRWAY Install lenses on two f'ixtures located at the top of stairway. Repair and secure hanging light in stairway. Lower hanging light is an obstruction to the exitway. replace or relocate. GENERAL , Repair or replace all e~it lights. , finis.