HomeMy WebLinkAboutOccupancy Correspondence 1988-2-1 ~,ii'/ (Ii" . . SPRINGFIELD CITY OF SPRINGFIELD Office of Community & Economic Development Planning and Development Department February I, 1988 .. Blmo Aldridge 205 S. 54th Street #2 " Springfield, OR 97478 '.;,) :.:.;.;'..;.'.... .. ,;1" Subject: Occupancy Inspection at 715 Main Street Springfield, Oregon. Proposed Use: Print Shop, ,.' '* ". ....J:.- ':' City Job #880039 At your request, the Springfield Building Safety Division recently conducted an inspection of the building(s} at the above address. The purpose of the inspection was to determine the suitability of the building(s} for the proposed use as indicated. Based on the proposed occupancy, the existing conditions which are mentioned below do not meet the minimum Building Safety Code requirements. Corrective measures must be taken prior to occupancy to install, repair, replace or modify the following items in order for the building to conform to applicable safety codes: Structural I, 1. Install fire extinguishers of the 'size and type in location(s} required by the City Fire Marshal. 'Please call the office of Fire & Life Safety at , 726-3737 to coordinate the specific reql1L ~~_ts. Blectrical J " 2. Install a junction box for the exposed wiring splice near the electrical panel. ,1,. 3. Secure the light fixture above the electrical panel. 4. Secure electrical conduit to the wall in storage room. ", 5. Install a 90 degree flex connector on conduit for the water heater. "'::-. 225 Fifth Street . Springfield, OR 97477 .. , 503/726-3753 .' '.. ~. .. .. . ,~~. , ....,....... . , ." :.;.,." , .":' ..'..... .~' ,.~~. ,,: .t:;:..:;. '.' ~ :>~-' :::-.' \.,.. -'" ,.. .... ,;1- . . Elmo Aldridge February 1,' 1988 Page 2 ' ,~ Plumbing .,' ", 6. Install open front seats on all toilets when they are in a public restroom. 7. Install an atmospheric vacuum breaker on the laundry tray faucet. 8. Relocate the shut-off valve at the water heater from the discharge side to the inlet side of the heater. 9. The temperature and pressure relief valve shall be located closer to the water heater to enable the sensor tube of the valve to extend into the heater. Mul tiproperty Use 10. A declaration of restrictive covenent shall be prepared by the owner for this property to provide an opening in the firewall to the adjoining property for concurrent leasing by the tenant. The declaration shall be recorded as a covenant on this property after all appropriate signatures are obtained. (A sample declaration is attached). _ c, Please note that installation of electrical systems on property which is intended for lease, sale or rent must be done by an electrical contractor who is licensed by the State of Oregon. Please also note that the above itemS which effect the health and safety of the occupants must be corrected and verified by the appropriate City inspectors prior to using the building for the proposed purpose. If we can be of assistance in clarifying the requirements, or the options available to bring the building into compliance, please call us at 726-3759. -" Sincerely, /L-71~ Don Moore _- Structural-Inspector t/-L ;tj~ Half;[ Shaw - Plumb.;Mech. Inspector CC: '.:; Dave Puent, Building Official Mike Hudman, Fire Marshal Del Matheson, 126 N. 4th St, Springfield, OR ... ~. -, . .~:, " . . .-." ~, ......: ..:.". -::~., .... ", ... :.... '<:': '. . ,., ".'