Loading...
HomeMy WebLinkAboutPermit Building 2004-5-19 (4) :. 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line '*: . CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/14/2002 EXPIRES: 11/19/2004 VALUE: $ 230,257.00 SITE ADDRESS: 630 Main St ASSESSOR'S PARCEL NO.: 1703353108900 Spr TYPE OF WORK: Commercial Miscellaneous TYPE OF USE: Remodel Commercial PROJECT DESCRIPTION: Remodel theater building. Phase I, Interior Demolition Only and reroof, existing structural only. Phase 2, Remainder of structural, interior remodel & marquee extension. Phase 2 will start in March 2004 and has been modified so that there will be at least one more phase depending on funding. Owner: Springfield Renaissance Dev. Address: POBox 155 Springfield OR 97477 Phone Number: (541) 736-0503 I CONTRACTOR INFORMATION I Contractor Type Contractor License Expiration Date Phone Architect Poticha Architects (541) 686-9466 General CHAMBERS CONSTRUCTION Electrical BUILDERS ELECTRIC INC 4296 12110/2007 541-485-0922 Engineer HOHBACH - LEWIN, INC 541-349-1701 Plumbing TWIN RIVERS PLUMBING 17695 03/11/2005 541-688-1444 I BUILDING INFORMATION I . ,: \I ~' ~v # of Units: ~ ,\X1,ilfli~ries: ~!4e' Primary Occupancy Group: A-2.1 ~<<" k,~ tg'hll of Structure '~~"oor: Secondary Occupancy Group: <$- S q, , e of Heat: ~fif> ~ ~oor: Primary Construction Type ~r '\~ ~~<;5water Type: \cPO\0QS~ll'1..~s~~t: Secondary Construction T~pe: sY:' ~<<,,<<:- ~~ Range Type: "lj~.;s.0 ~0~~~~~arport # of Bedrooms: ~fV<<-' #' YJ~ {O~. Energy Path: ~o~ '0" 'lfS ~~~~o<' _,~'" q,<<"~ -(J.,<<"~ ~ \J~_~<;5 Sprinkled Building: . 0\0 <,>,-00~" ov~ @a:~~t*,cf.d: "'" ,.c..,: -~ -] Ov _~. ,<,>,< ."'~ _,0 ~ _,0 \~~'\~~~~\J ~~ I DEVELOPMENT I~~:{~?~.~~~~~,-e~~~~~\' 1:,<;5 ~ ,'l> ' ~. ~', 0<' !:l~' o~ ~. ~ O~ ~".)'I; REQUIRED PARKING ~ $;.0 '*' ~'l: ~~ ~,-0 eC$ !y Frontyard Setback: ~ Overlay Dist? ~v <(. q) ~ ~ v0 O~ $\S Total: Side 1 Setback: # Street Tree$-<R(Ui: -.\,0 .;s.e ~.;s.0 '{P'" Handicapped: Side 2 Setback: Paved Drive RtIl!:;)<1l()' &.'~C?, \,0 ~0\ Compact: Rearyard Setback: % of Lot Covera)le: v'li- ~'O0 v0 Solar Setbacks: ~-S I PUBLIC IMPROVEMENTS I Street Improvements: Storm Sewer Available: Special Instruction: Sidewalk Type: DownspoutslDrains: Notes: Pal!e 1 of6 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Description Tvpe of Construction Use Bid Amount Use Bid Amount Bid Amount Bid Amount Fee Description Commercial Plan Check Fire & Life Safety Plan Review + 7% State Surcharge + 80/0 Administrative Fee Additional Plan Check Demolition + 7% State Surcharge + 8% Administrative Fee Temp Power 200 amps or less + 7% State Surcharge + 7% State Surcharge + 8% Administrative Fee + 8% Administrative Fee Building Permit Miscellaneous Plumbing + 10% Administrative Fee + 7% State Surcharge Backflow Device Building Permit Fixture + 10% Administrative Fee + 7% State Surcharge Add, Aller, Extend Circ Minimum/Adjustment Electrical Total Amount Paid . . CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/14/2002 EXPIRES: 11/19/2004 VALUE: $ 230,257.00 I Valuation Descrintion I $ Per Sq Ft or mulliplier $1.00 $1.00 Square Footage or Bid Amount 488,005.00 230,257.00 Value Date Calculated, Total Value of Project $488,005.00 $230,257.00 $718,262.00 11105/2002 03/2312004 If ppt tIiII.I Amount Paid Date Paid Receipt Number $1,309.85 $806.06 $3.15 $3.60 $20.28 $45.00 $3.50 $4.00 $50.00 $3.15 $128.09 $3.60 $146.39 $1,829.90 $45.00 $177.54 $124.28 $28.00 $991.40 $756.00 $4.50 $3.15 $43.00 $2.00 8/14/02 8/14/02 10/14/02 10/14/02 10/14/02 10/14/02 1114/02 1114/02 11/4/02 1116/02 1116/02 1116/02 1116/02 1116/02 11/6/02 3/31104 3/31104 3/31104 3/31/04 3/31/04 5/19/04 5/19/04 5/19/04 5/19/04 10282 10282 1200200000000000058 1200200000000000058 1200200000000000058 1200200000000000058 1200200000000000183 1200200000000000183 1200200000000000183 1200200000000000200 1200200000000000200 1200200000000000200 1200200000000000200 1200200000000000200 1200200000000000200 1200400000000000423 1200400000000000423 1200400000000000423 1200400000000000423 1200400000000000423 2200400000000000611 2200400000000000611 2200400000000000611 2200400000000000611 $6,531.44 I Plan Reviews I Pal!e 2 of6 . . CITY OF ~rKll~GFIELD Building/Combination Permit Status Issued PERMIT NO: 02-00980-01 225 Fifth Street, Springfield, OR ISSUED: 05/1912004 541-726-3753 Phone APPLIED: 08/14/2002 541-726-3676 Fax EXPIRES: 11/1912004 541-726-3769 Inspection Line VALUE: $ 230,257.00 Fire Marshal-CIIIP 10/21/2002 APP AG I. Plan Review - Phase I, Demolition, Theater remodel, Occupancy A2.1 I. Fire Department. Standpipes will not be required due to limited combustible load anticipated and limited ceiling height in the performance ares. 2. Provide installation, pressure test, flush of fire line in accordance with NFP A 24 from the point of public connection forward to the building sprinkler system. 3. Demolition procedures are to be carried out in compliance with teh code requirements as set forth in Article 87 of the Uniform Fire Code as adopted by the City of Springfield. Initial Review-CIIIP 08/15/2002 Appr LH Structural Review 10/03/2002 10/03/2002 10 DLM FedEx'd the following to Tom Rogers today I. Response to Plan Review Comments from project engineer, 2. Structural Plan Revisions dated 9/19/02 (w/lIxI7 drawings), 3. Supplemnetal Structural Calculations, 4. Geotechnical report. dim Structural Review 03/19/2004 03/2912004 APP JMP Received a fax from Steve McCallen with Chambers with scope of work and values for the phases. Phase I has been completed. This permit is for Phase II. Fees have been added for building and plumbing. No additional electrical application has been received. Structural Review 10/29/2002 10/23/2002 APP TR Structural modifications only. Fire & Life Safety review is not completed. Structural-CII/P Pend TR Fed Ex'd Addendum and structural calculations. Ih Pal!e30f6 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Structural-CIIIP . 08/26/2002 Wait TR Pal!e 4 of6 . CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/14/2002 EXPIRES: 11119/2004 VALUE: $ 230,257.00 Preliminary plan review revealed the following in part. See job file for complete letter and code references. I) The occupant load of the stage combined with the seating would resull in an occupant load exceeding 300. The occupancy classification for the building will be a group A Division 2.1. Please make the necessary modifications to the construction documents for this classification. 2) Please specify the distance from the building to the center of the alley. Ifless than 10 feet, openings in the wall need to be protected. Due to the construction of the alcove for the exit doors, protection at the exterior wall is not practical. As an equivalent protection, all construction in the alcove must be one hour rated with 3/4 hour doors. 3) Depending on the distance to the center of the alley, parapet construction, or ceiling rating, provisions of the OSSC may need to be addressed. STRUCTURAL I) Calculation page 23 specifies a 5x5x5/16 tube. Where is the thickness of the tube specified on the plans? 2) The floor framing,plans do not correspond to the structural calculations. Provide revised calculations for review. 3) Calculation page LI7 specifies an 18 inch footing for the interior CMU wall, whereas detailll/S5.3 shows 12 inch thickness. Please clarify. 4) Calculation pages L21 and L22 do not use the verticle distribution provisions of OSSC. Provide revised calculations for review. 5) Calculation page W3 specifies 4 inch nail spacing for the subdiphragm. Where is this noted on the plans? 6) Calculation page RI and R2 indicate the existing roof joists would be over stressed approximately 80% with code prescribed snow loads. Due to the change of occupancy classification, these joists need to be . . CITY OF ~rKll~\.Jl'l~LD Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/14/2002 EXPIRES: 11119/2004 VALUE: $ 230,257.00 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line upgraded. 7) Detail9/S7.1, as referenced on sheet S3.1, elevation line 2.6, appears to have been omitted. Provide a copy for review. 8) Provide a copy of the geotechnical report for review. To Request an inspection call the 24 hour recording at 726-3769. All inspection requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following work day. Ueollire~n~ne{'tions I I Temporary Electric: Approval required prior to Utility Company energizing pole. 2 Footing: After trenches are excavated. 3 Foundation: After forms are erected but prior to concrete placement. 4 Framing Inspection: Prior to cover and after all rough in inspections have been approved. 5 Epoxy Anchors: To be done by Certified Spcial Inspector. Provide Inspection results to City Building Inspector. 6 High Strength Bolting: To be done during construction by a State Certified Special Inspector. Provide inspection resulls to City Building Inspector. 7 Structural Masonry: To be done during construction by a State Certified Special Inspector. Provide results to City Building Inspector. 8 Bolts Installed in Concrete: To be done by a State Certified Special Inspector. Provide inspection test reports to City Building Inspector. 9 Structural Concrete: In excess of2500 psi. To be done during construction by a State Certified Inspector. Provide results to City Buiding Inspector 10 Structural Welds: To be done during construction by State Certified Special Inspector. Provide inspection test results to City Building Inspector. II Underfloor Plumbing: Prior to insulation or decking. 12 Slab: To be made after all inslab building service equipment, conduit piping and other equipment items are In place but prior to concrete. 13 Fire Department Sprinkler System: Prior to cover. Hydro pressure test, fire line flow test. 14 Final Fire Department. After all requirements of the Fire Department have been met. 15 Final Building: After all required inspections have been requested and approved and the building is complete. 16 Underslab Plumbing: Prior to filling the trench and including required testing. 17 Rough Plumbing: Prior to cover and including required testing. 18 Final Plumbing: When all plumbing work is complete. 19 Underslab Electric: Prior to cover 20 Rough Electric: Prior to Cover 21 Final Electric: When all electrical work is complete. 22 Structural Concrete: In excess of 2500 psi. To be done during construction by a State Certified Inspector. Provide resulls to City Buiding Inspector 23 Backflow Device: Prior to covering and provide a copy of the test report on site at the time of inspection. Pal!e 5 of6 . Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line . CITY OF SPRlNuNJ!.LIJ Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/14/2002 EXPIRES: 11/19/2004 VALUE: $ 230,257.00 By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. ~ii~i?:~~-,,- ~ Pal!e 6 of6 5-IK-OLJ Date 225 FIFTH STREET. SPRINGFIELD, OR 97477 . PIl:(541)726-3753 . Flo~if~~~~llr9i68ljassubmittedhasthefoIlOWlng ELECTRICAL PERlIfIT APPLICATION appr~;a~, does not require specific land use City Job Number 0'2...- 00 ~ eO - 0 \ Date 6 S ~ l '? -C>~ Zoning (l,(l...-. ,< ,,_, ,,",', ".__"OetA" - ,-?-':"'5-0:tk~"" 3, ,:COMPLEl'ER ' C ' ULEBELOW',< . ' "",' '''' '.'., ",.".-,-,,,.,.,j\{ltllo~ze{f~ature'" . " ,{, <";,,..?<=K ' "," ,.;.' ..,.....~.,...-';'"~'7~..,~..""'.,~ ....T. . _ ~. ~,."l'-':' "'.., :..~,....~..:, """1\ 1. EL2f:A'!lP!'!.:Q!Sl.NSr*M"l1, o.!Y:" ic:D":,.iA (;/3lS-" Met;: n"S€ ,,~, . :t"': : .,,-.. '~'. " '".. . ~ ,", '" ';;. '. . "'. ..' . ,'....- ." , . ... A, ,Ncw:Rcsideltiial"':Singlc'or Ji-Iulti-Faiitil\' per 'd,;'cUlng '~nit.; " .. -,,'. <..._.::......::.. . ,'. .,.. "J ,.'~' . ~ -' , '.:'. ....l. ...... '.' LEGAL DESCRIPTION _l '1. Cl~ -:''5" '3> l b ~")oo Service Included JOB DESCRIPTION 1000 sq, ft, or less \ ) ,^ .J, 0 11 r '''''') _ --1 r rl. f Each additional 500 sq. ft, or r nv I \J) Y\ A '(1\ ) tar 1-. ec;\-Y\ C'cc portion thereof Permits are non-transferable and expire if work is Each Manufact'd Home or not started within 180 days of issuance or if work is Modular Dweiling Service or Suspended for 180 days, Feeder ~::::'i~~'i;;''r'''::;sv '_1't,.,::~:.,\!:,,"""',-:::r, .~:'"' '.',-:f"{.~; ."""":'.:.'1.... ~ "r~--7''''.'' ,/.!.:":;. _H' ,-,-' ~"~"~. ,~:-. ~ "'$':: ". ..~ :";,', :f' ....'. ::""":'!-:' :~~.: "'-,CONTRACTORINSTALI:ATION ONLY B. ',SerVIces or, Feeders ~.Installahon.Allernhons or Relocation:: 2. ~~"':I,!l,(-ii;{llr~.;~;.o;..::;"'~~,,~.-:';;'I.:,/,'~)<H"i.;~tO~',~,::::;:t...t'''':'.~,..",,~..,: ot:.' " . .'.'..,...... }"';', ...,t,,' ~h.'~' ,..~.':o'i;" ," . I" Electrical Contractor RllI'ldpfS ' [iec+r, t InC 200 Amps or less $ 63,00 20 I Amps to 400 Amps $ 75,00 40 I Amps to 600 Amps $125,00 601 Amps to 1000 Amps $163,00 Over 1000 AmpslVolts $375,00 Reconnect Only $ 50,00 $106,00 $ 19,00 $50,00 Address ICJS Mack'\0I\ City fl'5C'ne Phone 4 ~:::d)1~;;:z Supervisor License Number 3290 - S Expiration Date 10, 1- 04 Constr, Contr, Number 4:;;lq ( 0 Expiration Date I'J. - r () - 01 ....rc,....'...',..,,,.'.........e'-;lf. 'T.';J'"!''''T',-''''r~' ~)'~r,.".T';"'~~fI' .,.'"'....1?~.\. 'l"'~.. "R;1'''I-''''''''''l S. .':t.(".:., -...' ,'. 'l~ -. .~ ....~.- ,~',I ,~;,..:..". -'J.{ 1'-". i.O"', "..' ... ;., C. ,i !~~J:>.or~ry.~~,r:vl~~~ or~'!.!.~er~:/::'~:~'~) '.'~"<::'~'\lii'/:~ :G'~~~~~' :;~'.~;~',b\~'~ Installation, Alteration or Relocation 200 Amps or less 201 Amps to 400 Amps 40 I Amps to 600 Amps Over 600 Amps or 1000 Volts see "B" above, f,'- ';'; -:::',.. ...... ' "J. rl~:: ~.\I'.::'(;~,:=::~:,.J :'~r'-:'<~k8~;' 'r':~:'::: ::~~f:H:~::,{~r:::-~i,~'.S~:,T~.W.. ~:~ D. . Branch CirCUits \I"~ . ""\1" .j....i:u\."~.i.. .' '~'. "I~.'~'1' . -, -O;,'~,,-.:, -~ I' )>111'", ..' '. ,I. . " .... ~ !"', ~~' ," '. ... . , ,,,~ ,.' "',' ':"'!1' ,,' ':'" ,"', I $ 50,00 $ 69,00 $100,00 - New Alteration or Extension Per Panel One Circuit --L $ 43,00 iZ-:et--\. \).E-J Each Additional Circuit or with , Service or Feeder Permit 43- -:;:'?(Z..d{~ E"('C..l..-t::> Owners Name W i \ \ 'S; h Address 20 ~ ,tS5 City ~1t-lGEl~L-D Phone l3b - 0 563:> $ 3,00 ,~;.~' ..~.,..,,_.,~,.1'\ '",':<~:', ,'.-'Ct.';,.,..,,; ....~,....,."> '.. J' ", . ,'-' f", E. ,Miscellnneous (Service/feeder not htcluded),-Ench Installation " ....' , .".- "."...,. '. -'. . ." . -' .... Pump or irrigation Sign/Outline Lighting Limited Energy/Residential Limited Energy/Commercial $ 50,00 $ 50,00 $ 25,00 $ 45,00 OWNER INSTALLATION The installation is being made on property I own which is not intended for sate, lease or rent. Owners Signature: Minimum Electric Permit Inspection Fee is $45.00 + Surcharges ~~':I:: :-...:....-.; """":;1..;,'"; ......-."::F~...-'~..~~..-f~ .~ .~. 71:1:;..- 4.-;'SUBTOTAL,OFABOVElc', ~':.:;,; ,:<,:,";": ":.t'~.,". :"!;" ",~.':q':,~";,,,,<;~,, ". .:. 7% State Surcharge 10% Administrative Fee 4:--5" ,CO :, ,lS" ~,SO 5'2..,65"' Inspection Request: 726-3769 TOTAL Shored Drive{T:)/Building Fonns/Elettrical Permit Application I-03.doc 225 Fifth Street Springfield, Oregon 97477 541-726-3759 Phone Job/Journal Number 02-00980-0 I 02-00980-0 I 02-00980-0 I 02-00980-0 I Payments: , Type of Payment CreditCard 5/19/2004 . RECEIPT #: ~~~R.'.!"'!.~~ -.-- i Wit, - '~,.~ i . ~ ,f ~ty of Springfield Official Receipt .elopment Services Department Public Works Department 2200400000000000611 Description Add, Alter, Extend Circ Minimum! Adjustment Electrical + 7% State Surcharge + 10% Administrative Fee Paid By BUILDERS ELECTRIC Received By jmp Page 1 of 1 Date: 05/19/2004 Item Total: Check Number Authorization Batch Number Number How Received 000837 026717 In Person Payment Total: 8:49:33AM Amount Due 43,00 2,00 3,15 4,50 $52.65 Amount Paid $52.65 $52.65