HomeMy WebLinkAboutPermit Building 2004-5-19 (2)
.ITY OF SPRINGFIELD'
Building/Combination Permit
PERMIT NO: 02-00980-01
ISSUED: 05/19/2004
APPLIED: 08/14/2002
EXPIRES: 11/05/2006
VALUE: $ 1,298,870.00
.
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
SITE ADDRESS: 630 Main St
ASSESSOR'S PARCEL NO.: 1703353108900
Spr
TYPE OF WORK: Commercial Miscellaneous
TYPE OF USE: Remodel Commercial
PROJECT DESCRIPTION: Remodel theater building. Phase I, Interior Demolition Only and reroof, existing
structural only. Phase 2, Remainder of structural, interior remodel & marquee
extension. Phase 2 will start in March 2004 and has been modified so that there will be
at least one more phase depending on funding.
Owner:
Address:
, outo
" r:~: 'r':1law requires y .. Phone Number:
, . .cu by thz Oregon Utility
. n\~' Those rules are set lorth
Iv,[..... . ,....",not::"'Lf'ln1_
. I. .'. .).UUI-UUIUllIIV....~..-
Ill' " , " J~ . " . -Illes by
O 1,(2Vl" M(;;.TORiINFORMA TION I
' lone
'.II'ng the center. \,"VI", ."~ ...-.': '
C" I UC" . ~'''''flcatlcn
Contractor number lor the Oregon Uicense . Expiration Date
Poticha Architects Center is 1_800-332-2344).
CHAMBERS CONSTRUCTION 114258
BUILDERS ELECTRIC INC 4296
HOHBACH - LEWIN, INC
OMLID & SWINNEY FIRE SPRINKLER
COMFORT FLOW
TWIN RIVERS PLUMBING
Springfield Renaissance Dev.
POBox 155
Springfield OR 97477
Contractor Type
Architect
General
Electrical
Engineer
Low Voltage Electrical
Mechanical
Plumbing
05/30/2007
12110/2007
62730
460
17695
12/15/2007
06/27/2007
03/11/2007
# of Units:
Primary Occupancy Group:
Secondary Occupancy Group:
Primary Construction Type
Secondary Construction Type:
# of Bedrooms:
BUILDING INFORMATION I
~1'If Styrie~: Lot Size:
!!J~~\ 6~~~r~ct~r"ALL EXPIRE IF TH~l,t",l~t Floor:
TWe olflHeat: I ~H ~l! tt 2nd Floor:
\\lat~~ii)lJJm UNDER THIS PERMIT Sq P[.Basement:
J!a]iliMMiHD OR IS ABANDONED FSlfFt Garage/Carport
Ip.,q~I,1:Yl!'l!'t!J;\Y PERIOD. Sq Ft Other:
Sprinkled Building: Yes Occupant Load:
A-2.1
V1hr
I DEVELOPMENT INFORMATION I
(541) 736-0503
Phone
(541) 686-9466
687-9445
541-485-0922
541-349-170 I
541-741-1775
541-726-0100
541-688-1444
REQUIRED PARKING
Frontyard Setback:
Side I Setback:
Side 2 Setback:
Rearyard Setback:
Solar Setbacks:
Total:
Handicapped:
Compact:
Overlay Dist:
# Street Trees Rqd:
Paved Drive Rqd:
% of Lot Coverage:
Pal!e 1 of8
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
Street Improvements:
Storm Sewer Available:
Special Instruction:
Notes:
Description
Tvpe of Construction
Bid Amount
Bid Amount
Bid Amount
Use Bid Amount
Use Bid Amount
Use Bid Amount
Fee Description
Commercial Plan Check
Fire & Life Safety Plan Review
+ 7% State Surcharge
+ 8% Administrative Fee
Additional Plan Check
Demolition
+ 7% State Surcharge
+ 8% Administrative Fee
Temp Power 200 amps or less
+ 7% State Surcharge
+ 7% State Surcharge
+ 8% Administrative Fee
+ 8% Administrative Fee
Building Permit
Miscellaneous Plumbing
+ 10% Administrative Fee
+ 7% State Surcharge
Backflow Device
Building Permit
Fixtu re
+ 10% Administrative Fee
+ 7% State Surcharge
Add, Alter, Extend Circ
Minimum/Adjustment Electrical
+ 10% Administrative Fee
.
.ITY OF SPRINGFIELD'
Building/Combination Permit
PERMIT NO: 02-00980-01
ISSUED: 05/19/2004
APPLIED: 08/14/2002
EXPIRES: 11105/2006
VALUE: $ 1,298,870.00
I PUBLIC IMPROVEMENTS I
Sidewalk Type:
DownspoutslDrains:
I Valuation Descriotion I
$ Per Sq Ft
or multiplier
$1.00
$1.00
$1.00
Square Footage
or Bid Amount
488,005.00
230,257.00
580,608.00
Value
Date Calculated
$488,005.00
$230,257.00
$580,608.00
$1,298,870,00
t 1/05/2002
03/23/2004
05/11/2006
Total Value of Project
Fpp<, PiiILI
Amount Paid
$1,309.85
$806.06
$3.15
$3.60
$20.28
$45.00
$3.50
$4.00
$50.00
$3,15
$128.09
$3.60
$146.39
$1,829.90.1
$45.00
$177.54
$124.28
$28.00
$991.40 I
$756.00
$4.50
$3.15
$43.00
$2.00
$4.50
Date Paid
8/14/02
8/14/02
10/14/02
10/14/02
10/14/02
10/14/02
1114/02
1114/02
1114/02
1116/02
11/6/02
tl/6/02
1116/02
11/6/02
1116/02
3/31/04
3/31/04
3/31/04
3/31/04
3/31/04
5/19/04
5/19/04
5/19/04
5/19/04
10/27/05
Receipt Number
10282
10282
1200200000000000058
1200200000000000058
1200200000000000058
1200200000000000058
1200200000000000183
1200200000000000183
1200200000000000183
1200200000000000200
1200200000000000200
1200200000000000200
1200200000000000200
1200200000000000200
1200200000000000200
1200400000000000423
1200400000000000423
1200400000000000423
1200400000000000423
1200400000000000423
2200400000000000611
2200400000000000611
2200400000000000611
2200400000000000611
220050000000000t513
Pal!e 2 or8
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
+ 7% State Surcharge
Low Vollage - Commercial Indus
+ 10% Administrative Fee
+ 8% State Surcharge
Low Voltage - Commercial Indus
-Mechanical Issuance Fee-
+ 10% Administrative Fee
+ 8% State Surcharge
Appliance Not Listed
Boiler/Comp Up To 100,000 htu
Encroachment Permit
Furnace - Unit Heater
Gas Outlets 1-4
Heat Pump
Vent Fan
+ 10% Administrative Fee
+ 7% State Surcharge
Building Permit
Plan Review Comm/IndlPublic
Plan Review Fire & Life Safety
. Total Amonnt Paid
Fire Department Review
.
$3.15
$45.00
$4.50
$3.60
$45.00
$10.00
$11.20
$8.96
$18.00
$24.00
$130.00
$24.00
$4.00
$12.00
$30.00
$t64.10
$114.88
$1,641.10
$1,570.43
$978.90
$11,378.76
.ITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO: 02-00980-01
ISSUED: 05/19/2004
APPLIED: 08/14/2002
EXPIRES: 11/05/2006
VALUE: $ 1,298,870.00
10127/05
10/27/05
4/28/06
4/28/06
4/28/06
5/5/06
5/5/06
5/5/06
5/5/06
5/5/06
5/5/06
5/5/06
5/5/06
5/5/06
5/5/06
5/16/06
5/16/06
5/16/06
5/16/06
5/16/06
2200500000000001513
2200500000000001513
1200600000000000566
1200600000000000566
1200600000000000566
1200600000000000607
1200600000000000607
1200600000000000607
1200600000000000607
1200600000000000607
2200600000000000563
1200600000000000607
1200600000000000607
1200600000000000607
1200600000000000607
1200600000000000660
1200600000000000660
1200600000000000660
1200600000000000660
1200600000000000660
I Plan Reviews I
OS/24/2004
OS/24/2004
OK
GRG
Plan Review: Wet sprinkler system
for Wildish Theater. Job
#02-00980-01. 134 sprinkler heads.
Contractor: Om lid and Swinney.
Designer: Shawn Fenneran, NICET
Level III Technician.
Coordinate with fire alarm
contractor for monitoring of
waterflow and tamper switches.
Sprinkler coverage shall be extended
underneath all combustible
stairways in this occupancy (NFPA
13-19995-13.3.1; NFPA 13-2002
8.14.3.1)
Provide auxiliary drains where
changes in piping direction prevents
drainage of system piping through
the main drain valve (NFPA 13-1999
5-14.2.5.1; NFPA 13-2002
8.15.2.5.1).
Pal!e 3 of8
. .ITY OF SPRINGFIELD
Building/Combination Permit
Status Issued PERMIT NO: 02-00980-01
225 Fifth Street, Springfield, OR ISSUED: 05/19/2004
541-726-3753 Phone APPLIED: 08/14/2002
541-726-3676 Fax EXPIRES: 11/05/2006
541-726-3769 Inspection Line VALUE: $ 1,298,870.00
Fire Denartment Review 04/11/2006 04/14/2006 OK 'GRG Revised Plans. See attached
document for Fire Department
Plans Review comments.
Fire Marshal-CIIIP 10/21/2002 APP AG I. Plan Review - Phase I,
Demolition, Theater remodel,
Occupancy A2.1
I. Fire Department. Standpipes will
not be required due to limited
combustible load anticipated and
limited ceiling height in the
performance area.
2. Provide installation, pressure
test, flush of fire line in accordance
with NFPA 24 from the point of
public connection forward to the
building sprinkler system.
3. Demolition procedures ore to be
carried out in compliance with teh
code requirements as set forth in
Article 87 of the Uniform Fire Code
as adopted by the City of
Springfield.
Initial Review-CII/P 08/15/2002 Annr LH
Plan Review Comments 04/1212006 10 DLM Received revised plans 4/6/06 for
interior improvements. Forwarded
to P.W. & F.D. for review ond
approval.4/7/06dlm. Received
HV AC energy forms 4/11/06 &
forwarded to SUB 4/12/06dlm.
Public Works Review 03/24/2006 03/24/2006 APP SB Revised Plans - Remodel only;
Added SDCs for new plumbing
fixtures with 750/0 Downtown
Development credit.
Structural Review 10/03/2002 10/03/2002 10 DLM FedEx'd the following to Tom
Rogers today I. Response to Plan
Review Comments from project
engineer, 2. Structural Plan
Revisions dated 9/19/02 (w/lh 17
drawings), 3. Supplemnetal
Structural Calculations, 4.
Geotechnical report. dim
Structural Review 10/2912002 10/23/2002 APP TR Structural modifications only. Fire
& Life Safety review is not
completed.
Pal!e 4 of8
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
Structural Review
Structural Review
Structural-CIIIP
.
03/19/2004
04/11/2006
03/29/2004
05/10/2006
.ITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO: 02-00980-01
ISSUED: 05/19/2004
APPLIED: 08/14/2002
EXPIRES: 11/05/2006
VALUE: $ 1,298,870.00
APP JMP
Received a fax from Steve McCallen
with Chambers with scope of work
and values for the phases. Phase I
has been completed. This permit is
for Phase II. Fees have been added
for building and plumbing. No
additional electrical application has
been received.
Revised Plans - Interior finish
Fed Ex'd Addendum and structural
calculations. Ih
APP LDM
Pend TR
Pal!e 5 of8
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
54t-726-3676 Fax
541-726-3769 Inspection Line
Structural-CIIIP
.
08/26/2002
Wait TR
Pal!e 6 of8
.ITY OF ~rK11~\.JI'IELD
Building/Combination Permit
PERMIT NO: 02-00980-01
ISSUED: 05/19/2004
APPLIED: 08/14/2002
EXPIRES: 11/05/2006
VALUE: $ 1,298,870.00
Preliminary plan review revealed
the following in part. See job file for
complete letter and code references.
I) The occupant load of the stage
combined with the seating would
resull in an occupant load exceeding
300. The occupancy classification
for the building will be a group A
~ivision 2.1. Please make the
necessary modifications to the
construction documents for this
classification. 2) Please specify the
distance from the building t~ the
center of the alley. Ifless than 10
feet, openings in the wall need to be
protected. Due to the construction
of the alcove for the exit doors,
protection at the exterior wall is not
practical. As an equivalent
protection, all construction in the
alcove must be one hour rated with
3/4 bour doors. 3) Depending on
the distilDce to the center of the
alley, parapet construction, or
ceiling rating, provisions of the
OSSC may need to be addressed.
STRUCTURAL I) Calculation
page 23 specifies a 5x5x5/16 tube.
Where is the thickness of the tube
specified on the plans? 2) The floor
framing plans do not correspond to
the structural calculations. Provide
revised calculations for review. 3)
Calculation page LI7 specifies an 18
inch footing for the interior CMU
wall, whereas detailll/S5.3 shows
12 inch thickness. Please clarify. 4)
Calculation pages L21 and L22 do
not use the verticle distribution
provisions of OSSc. Provide revised
calculations for review. 5)
Calculation page W3 specifies 4 inch
nail spacing for the subdiphragm.
Where is this noted on the plans? 6)
Calculation page RI and R2 indicate
the existing roof joists would be over
stressed approximately 80% with
code prescribed snow loads. Due to
the change of occupancy
classification, these joists need to be
.
.ITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO: 02-00980-01
ISSUED: 05/19/2004
APPLIED: 08/14/2002
EXPIRES: 11/05/2006
VALUE: $ 1,298,870.00
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
SUB Review
04/11/2006
04/25/2006
APP JF
upgraded. 7) DetaiI9/S7.1, as
referenced on sheet S3.1, elevation
line 2.6, appears to have been
omitted. Provide a copy for review.
8) Provide a copy of the
geotechnical report for review.
Revised Plans
To Request an inspection call the 24 hour recording at 726-3769. All inspection requested before 7:00 a.m.
will be made the same working day, inspections requested after 7:00 a.m. will be made the following work
day.
I Rpollirpr! ~
Temporary Electric: Approval required prior to Utility Company energizing pole.
Footing: After trenches are excavated.
SUB Mechanical: Following City Rough Mechanical inspection approval and prior to any cover.
Foundation: After forms are erected but prior to concrete placement.
Framing Inspection: Prior to cover and after all rough in inspections have been approved.
Epoxy Anchors: To be done by Certified Spcial Inspector. Provide Inspection resulls to City Building Inspector.
High Strength Bolting: To be done during construction by a State Certified Special Inspector. Provide inspection
resulls to City Building Inspector.
Structural Masonry: To be done during construction by a State Certified Special Inspector. Provide resulls to
City Building Inspector.
Bolts Installed in Concrete: To be done by a State Certified Special Inspector. Provide inspection test reports to
City Building Inspector.
Structural Concrete: In excess of 2500 psi. To be done during construction by a State Certified Inspector.
Provide results to City Buiding Inspector
Structural Welds: To be done during construction by State Certified Special Inspector. Provide inspection test
resulls to City Building Inspector.
Underfloor Plumbing: Prior to insulation or decking.
Slab: To be made after all inslab building service equipment, conduit piping and other equipment items are in
place but prior to concrete.
Fire Department Sprinkler System: Prior to cover. Hydro pressure test, fire line flow test.
Final Fire Department. After all requirements of the Fire Department have been met.
Final Building: After all required inspections have been requested and approved and the building is complete.
Underslab Plumbing: Prior to filling the trench and including required testing.
Rough Plumbing: Prior to cover and including required testing.
Final Plumbing: When all plumbing work is complete.
Pal!e 7 of8
.
.ITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO: 02-00980-01
ISSUED: 05/19/2004
APPLIED: 08/14/2002
EXPIRES: 11/05/2006
VALUE: $ 1,298,870.00
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
Underslab Electric: Prior to cover
Rough Electric: Prior to Cover
Final Electric: When all electrical work is complete.
Structural Concrete: In excess of 2500 psi. To be done during construction by a State Certified Inspector.
Provide resulls to City Buiding Inspector '
Backflow Device: Prior to covering and provide a copy of the test report on site at tbe time of inspection.
Low Voltage: Prior to cover.
Electric Service: Approval required prior to utility company energizing service.
SUB Final: After all required energy inspections have been requested and approved.
By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all
information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with
the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and
that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety.
I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project.
I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the
street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all
time"{]:nst7n. & 5/llD /Ola
owfor Contracrors Sign'ature - Date
Pal!e 8 of8
225 Fifth ,Street
Springfield, Oregon 97477
541-726-3759 Phone
. -r;-~
wr
C~f Springfield Official Receipt
"opment Services Department
Public Works Department
Job/Journal Number
02-00980-0 I
02-00980-0 I
02-00980-0 I
02-00980-0 I
02-00980-0 I
Payments:
Type of Payment
Check
cReceintl
RECEIPT #:
1200600000000000660
Date: 05/16/2006
Description
Building Permit
Plan Review Fire & Life Safety
Plan Review CommllndlPublic
+ 7% State Surcharge
+ 10% Administrative Fee
Paid By
CHAMBERS CONSTRUCTION
Item Total:
l.:heck Number Authorization
Received By Batch Number Number How Received
djb
57218
In Person
Payment Total:
Page I of I
10:59:3IAM
Amount Due
1,641.10
978,90
1,570.43
114,88
164,10
$4,469.41
Amount Paid
$4,469.41
$4,469.41
5/16/2006