Loading...
HomeMy WebLinkAboutPermit Building 2004-5-19 . Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726.3769 Inspection Line ~ SITE ADDRESS: 630 Main St ASSESSOR'S PARCEL NO,: 1703353108900 Spr . CITY OF SPRINGFIELD. ... Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/1912004 APPLIED: 08/1412002 EXPIRES: 12/1912006 VALUE: $ 580,608.00 TYPE OF WORK: Miscellaneous TYPE OF USE: Remodel Commercial PROJECT DESCRIPTION: Remodel theater building, Phase I, Interior Demolition Only and reroof, existing structural only, Phase 2, Remainder of structural, interior remodel & marquee extension, Phase 2 will start in March 2004 and has heen modified so that there will be at least one more phase depending on funding. Owner: Address: Springfield Renaissance Dev, POBox 155 Springfield OR 97477 Phone Number: (541) 736-0503 I CONTRACTOR INFORMATION I Contractor Type Architect General Electrical Engineer Low Voltage Electrical Mechanical Plumbing Contractor Poticha Architects CHAMBERS CONSTRUCTION BUILDERS ELECTRIC INC HOHBACH - LEWIN, INC OMLID & SWINNEY FIRE SPRINKLER COMFORT FLOW TWIN RIVERS PLUMBING License Expiration Date Phone (541) 686-9466 687-9445 541-485-0922 541-349-170 I 541-741-1775 541-726-0100 541-688-1444 114258 4296 05/30/2007 12/10/2007 62730 460 17695 12/15/2007 06/27/2007 03/11/2007 DlJlLUlNG INFORMATION I # of Units: ' Primary Occupancy Group: Secondary Occupancy Group: Primary Construction Type Secondary Construction Type: # of Bedrooms: # of Stories: Height of Structure Type of Heat: Water Type: Range Type: Energy Path: Sprinkled Building: A-2,1 Vlhr Yes Lot Size: Sq Ft 1st Floor: Sq Ft 2nd Floor: Sq Ft Basement: Sq Ft Garage/Carport Sq Ft Other: Occupant Load: I DEVELOPMENT INFORMATION I Front yard Setback:.n_, N fIO",c,["oon law reqloverlayIDis't: A Cl :~.......... . ..-.,...... Side I Setback: I 1-5 adopted by the O:#;~treet,Tr'ees. Rqd: S'd 2 S b k' fol ow ru" . P d'D"" 'R' d' I e et ac. .. . C ntc" Those rule~ ave : rive. q . ,.:>tlflcatlon e .. 0 r. -" Rearyard Setba~k: ~.OOi. 01C:'1rough c'-:'o,!lf'.UotCoverage: Solar Setbacks: In OAR 95,- bt' copies of the rules b~ OG90. You may 0 a'n calling the center. (Note: the tele,~ho~e number for the Oregon Utility Notification, Center is 1-800-332-2344), Paeelof9 REQUIRED PARKING Total: Hnndicapped: Compact: NOTICE: i~~~~E~~~E~DT ~O~R~~~ ~~~~RpEE':~~E,:~~: IS ABANDO~R ANY 18DOAY PERIOD. cS>"" Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Street Improvements: Storm Sewer Available: Special Instruction: Notes: Description TVDe of Construction Use Bid Amount Use Bid Amount Use Bid Amount Bid Amount Bid Amount Bid Amount Fee Description Commercial Plan Check Fire & Life Safely Plan Review + 7% State Surcharge + 8% Administrative Fee Additional Plan Check Demolition + 7% Stnte Surcharge + 8% Administrative Fee Temp Power 200 amps or less + 7% State Surcharge + 7% State Surcharge + 8% Administrative Fee + 8% Administrative Fee Building Permit Miscellaneous Plumbing + 10% Administrative Fee + 7% State Surcharge Backtlow Device Building Permit Fixture + 10% Administrative Fee + 7% State Surcharge Add, Alter, Extend Circ Minimum/Adjustment Electrical + 10% Administrative Fee . . CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/14/2002 EXPIRES: 1211912006 VALUE: $ 580,608.00 I PUBLIC IMPROVEMENTS I Sidewalk Type: Downspouts/Drains: I Valuation Descriotion I $ Per Sq Ft or multiplier $1.00 $1.00 $1.00 Square Footage or Bid Amonnt 488,005,00 230,257.00 580,608.00 Value Date Cnlculated $488,005.00 $230,257,00 $580,608,00 $1,298,870.00 11/05/2002 03/23/2004 05/ll/2006 Total Value of Project ~ Amount Paid $1,309.85 $806.06 $3.15 $3,60 $20.28 $45,00 $3,50 $4.00 $50,00 $3.15 $128.09 $3,60 $146,39 $1,829.90 $45,00 $177.54 $124,28 $28,00 $991.40 $756,00 $4.50 $3,15 $43.00 $2,00 $4,50 Date Paid Receipt Number 8/14/02 8/14/02 10/14/02 10/14/02 10/14/02 10/14/02 ll/4/02 ll/4/02 ll/4/02 ll/6/02 ll/6/02 ll/6/02 ll/6/02 ll/6/02 ll/6/02 3/31/04 3/31/04 3/31/04 3/31/04 3/31/04 5/19/04 5/19/04 5/19/04 5/19/04 10/27/05 10282 10282 1200200000000000058 1200200000000000058 1200200000000000058 1200200000000000058 1200200000000000183 1200200000000000183 1200200000000000183 1200200000000000200 1200200000000000200 1200200000000000200 1200200000000000200 1200200000000000200 1200200000000000200 1200400000000000423 1200400000000000423 1200400000000000423 1200400000000000423 1200400000000000423 2200400000000000611 2200400000000000611 2200400000000000611 2200400000009000611 2200500000000001513 Paee 2 of9 ......Itr~~~~.~~~' ~ '. - _: Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line + 7% State Surcharge Low Voltage - Commercial Indus + 10% Administrative Fee + 8% State Surcharge Low Voltage - Commerciallndns -Mechanical Issuance Fee- + 10% Administrative Fee + 8% State Surcharge Appliance Not Listed Boiler/Comp Up To 100,000 btu Encroachment Permit Furnace - Unit Heater Gas Outlets 1-4 Heat Pump Vent Fan + 10% Administrative Fee + 7% State Surcharge Building Permit Plan Review CommlInd/Public Plan Review Fire & Life Safety + 10% Administrative Fee + 8% State Surcharge Low Voltage - Commercial Indus Perm Serv/Fdr 1000 amps/volts Perm Serv/Fdr 200 amps or less Perm Serv/Fdr 201 to 400 amps Total Amount Paid . . CITY OF SPRINGFIELD' Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/14/2002 EXPIRES: 12/19/2006 VALUE: $ 580,608.00 $3.15 $45,00 $4,50 $3.60 $45,00 $10,00 . $11,20 $8,96 $18.00 $24.00 $130.00 $24,00 $4.00 $12,00 $30.00 $164,10 $114.88 $1,641.10 $1,570.43 $978,90 $87.90 $70,32 $90.00 $375,00 $189,00 $225.00 10/27/05 10/27/05 4/28/06 4/28/06 4/28/06 5/5/06 5/5/06 5/5/06 5/5/06 5/5/06 5/5/06 5/5/06 5/5/06 5/5/06 5/5/06 5/16/06 5/16/06 5/16/06 5/16/06 5/16/06 6/16/06 6/16/06 6/16/06 6/16/06 6/16/06 6/16/06 2200500000000001513 2200500000000001513 1200600000000000566 1200600000000000566 1200600000000000566 1200600000000000607 1200600000000000607 1200600000000000607 1200600000000000607 1200600000000000607 2200600000000000563 1200600000000000607 1200600000000000607 1200600000000000607 1200600000000000607 1200600000000000660 1200600000000000660 1200600000000000660 1200600000000000660 1200600000000000660 1200600000000000891 1200600000000000891 1200600000000000891 1200600000000000891 1200600000000000891 1200600000000000891 $12,415.98 I Plan Reviews I Pa2e 3 of9 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-37691nspection Line Fire Department Review Fire Department Review Fire Department Review . OS/24/2004 04/11/2006 06/19/2006 OS/24/2004 04/14/2006 06/19/2006 OK OK OK Paee 4 of9 . CITY OF SPRINGFIELD' Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/14/2002 EXPIRES: 12/19/2006 VALUE: $ 580,608.00 GRG Plan Review: Wet sprinkler system for Wild ish Theater. Job #02-00980-01. 134 sprinkler heads, Contractor: Omlid and Swinney. Designer: Shawn Fenneran, NICET Levellll Technician, Coordinate with fire alarm contractor for monitoring of waterflow and tamper switches, Sprinkler coverage shall be extended underneath all combustible stairways in this occupancy (NFP A 13-19995-13,3,1; NFPA 13-2002 8,14,3.1) GRG Provide auxiliary drains where changes in piping direction prevents drainage of system piping through the main drain valve (NFPA 13-1999 5-14.2,5,1; NFPA 13-2002 8.15.2,5.1), Revised Plans, See attached document for Fire Department Plans Review comments. Plans Review: Fire alarm system for Wildish Theater. Job #02-00980-0 \, Designer: Steve Francalancin, Contractor: Omlid and Swinney, Plans appear to meet cnde requirements. GRG Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Fire Marshal-CIUP Initial Review-C/I/P Plan Review Comments Plan Review Comments Public Works Review Structural Review . 03/24/2006 10/03/2002 10/21/2002 08/15/2002 04/12/2006 OS/23/2006 03/24/2006 10/03/2002 APP AG Appr 10 10 APP 10 Page 5 of9 . CITY OF SPRINGFIELD. Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/1912004 APPLIED: 08/14/2002 EXPIRES: 1211912006 VALUE: $ 580,608.00 1. Plan Review - Phase I, Demolition, Theater remodel, Occupancy A2,1 1. Fire Department. Standpipes will not be required due to limited combustible load anticipated and limited ceiling height In the performance area. . 2, Provide installation, pressure test, flusb of fire line In accordance with NFP A 24 from the point of public connection forward to the building sprinkler system. 3. Demolition procedures nre to be carried out in compliance with teh code requirements as set forth In Article 87 of the Uniform Fire Code as adopted by the City of Springfield, LH DLM Received revised plans 4/6/06 for interior Improvements, Forwarded to P.W. & F,D, for review and approvaI.4/7/06dlm, Received HV AC energy forms 4/11/06 & forwarded to SUB 4/12I06dlm. When Don Moore calculated and issued the building permit and additional plao review fees that werE collected on 5/16/06, he did not use Tidemark to calculate the fees, Don used the original permit fees, ndded them together, then calculated the difference between adjusted plan review and permit fees, Revised Plans - Remodel only; Added SDCs for new plumbing fixtures witb 75% Downtown Development credit, FedEx'd the following to Tom Rogers today 1. Response to Plan Review Comments from project engineer, 2. Structural Plan Revisions dated 9/19/02 (w/ IIxl7 drawings), 3, Supplemnetnl Structural Calculations, 4. Geotechnical report, dim LLH SB DLM Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Structural Review Structural Review Structural Review Structural-C/I/P . 10/29/2002 03/19/2004 04/11/2006 10/23/2002 03/29/2004 05/10/2006 . CITY OF SPRINGFIELD. Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/14/2002 EXPIRES: 12/19/2006 VALUE: $ 580,608.00 APP TR Structural modifications only, Fire & Life Safety review is not completed. Received a fax from Steve McCallen with Chambers with scope of work and values for the phases, Phase I has been completed. This permit Is for Phase II, Fees have been added for building and plumbing, No additional electrical application has been received, Revised Plans - Interior finish Fed Ex'd Addendum and structural calculations. Ih APP JMP APP DLM Pend TR Paee 6 of9 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Structural-C/IlP . 08/26/2002 Wait TR Paee 7 of9 . CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/1412002 EXPIRES: 12/1912006 VALUE: $ 580,608.00 Preliminary plan review revealed the following In part, See job file for complete letter and code references. 1) The occupant load of the stage combined with the seating would result in an occupant load exceeding 300, The occupancy classification for the building will be a group A Division 2, \, Please make the necessary modifications to the construction documents for this classification, 2) Please specify the distance from the building to the center ofthe alley. If less than 10 feet, openings in the wall need to be protected. Due to the construction of the alcove for the exit doors, protection at the exterior wall is not practical. As an equivalent protection, all construction In the alcove must be one hour rated with 3/4 hour doors, 3) Depending on the distance to the center ofthe alley, parapet construction, or ceiling rnting, provisions of the OSSC may need to be addressed, STRUCTURAL I) Calculation page 23 specifies a 5x5x5/16 tube, Where is the thickness of the tuhe specified on the plans? 2) The floor framing plans do not correspond to the structural calculations. Provide revised calculations for review, 3) Calculation page LI7 specifies an 18 inch footing for the Interior CM U wall, whereas detaillllS5,3 shows 12 Inch thickness, Please clarify. 4) Calculation pages L21 and L22 do not use the verticle distribution provisions of OSSC, Provide revised calculations for review, 5) Calculation page W3 specifies 4 Inch nail spacing for the subdiphrngm. Where is this noted on the plans? 6) Calculation page RI and R2 indicate the existing roof joists would be over stressed approximately 80% with code prescribed snow loads. Due to the change of occupancy classification, these joists need to be . . CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/1412002 EXPIRES: 12/19/2006 VALUE: $ 580,608.00 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line SUB Review 04/11/2006 04/25/2006 APP JF upgraded. 7) Detail 9/S7,1, as referenced on sheet S3,1, elevntion line 2.6, appears to have been omitted, Provide a copy for review, 8) Provide a copy of the geotechnical report for review, Revised Plans To Request an inspection call the 24 hour recording at 726-3769. All inspection requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following work day. Temporary Electric: Approval required prior to Utility Company energizing pole, Footing: After trenches are excavated. SUB Mechanical: Following City Rough Mechanical inspection approval and prior to any cover. Foundation: After forms are erected but prior to concrete placement, Framing Inspection: Prior to cover and after all rough in inspections have been approved, Epoxy Anchors: To be done by Certified Spciallnspector. Provide Inspection results to City Building Inspector. High Strength Bolting: To be done dnring construction by a State Certified Special Inspector, Provide inspection results to City Building Inspector. Structural Masonry: To be done during construction by a State Certified Special Inspector. Provide results to City Building Inspector, Bolts Installed in Concrete: To be done by a State Certified Special Inspector. Provide Inspection test reports to City Building Inspector. Structural Cnncrete: In excess of 2500 psi. To be done during construction by a State Certified Inspector, Provide results to City Buiding Inspector Structural Welds: To be done during construction by State Certified Special Inspector. Provide inspection test results to City Building Inspector. Undernoor Plumbing: Prior to insnlation or decking. Slab: To be made after all inslab building service equipment, conduit piping and other equipment items nre in place but prior to concrete. Fire Department Sprinkler System: Prior to cover, Hydro pressure test, fire line now test. Final Fire Department, After all requirements of the Fire Department have been met, Final Building: After all required inspections have been requested and approved and the building Is complete, Underslab Plumbing: Prior to filling the trench and including required testing, Rough Plumbing: Prior to cover and including required testing, Final Plumbing: When all plumbing work is complete. Pal!e 8 of9 . . CITY OF SPRll~\.Jt<lJ!.LD Building/Combination Permit PERMIT NO: 02-00980-01 ISSUED: 05/19/2004 APPLIED: 08/14/2002 EXPIRES: 12/19/2006 VALUE: $ 580,608.00 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Underslab Electric: Prior to cover \ Rough Electric: Prior to Cover Final Electric: When all electrical work is complete. Structural Concrete: In excess of 2500 psi. To be done during construction by a State Certified Inspector. Provide results to City Buiding Inspector Backflow Device: Prior to covering and provide a copy of the test report on site at the time of inspection. Low V ollage: Prior to cover. Electric Service: Approval required prior to utility company energizing service. SUB Final: After all required energy inspections have been requested and approved. By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the slle at all times during construction. Owner or Contractors Signature Date Pal!e 9 of9 225 Fifth Street SpringfieriJ, Oregon 97477 541-726-3759 Phone .&i~ ~ of Springfield Official Receipt Welopment Services Department Public Works Department Job/Journal Number 02-00980-01 02-00980-01 02-00980-0 I 02-00980-0 I 02-00980-0 I 02-00980-0 I Payments: Type of Payment Check cReceint 1 RECEIPT #: 1200600000000000891 Date: 06/16/2006 Description Perm ServlFdr 200 amps or less Perm ServlFdr 201 to 400 amps Perm ServlFdr 1000 amps/volts Low Voltage - Commercial Indus + 8% State Surcharge + 10% Administrative Fee Paid By BUILDERS ELECTRIC Item Total: Check Number Authorization Received By Batch Number . Number How Received IIh 93790 By Mail Payment Total: Page 1 ofl 3:12:39PM Amount Due 189.00 225.00 375.00 90.00 70.32 87.90 $1,037.22 Amount Paid $1,037.22 $1,037.22 6/1612006