me has been professionally Insulated with
PROPINK<E
Owens Corning
~ed Loosefilllnsulation (Red Bag)
INNOVATIONS FOR L1VINGN
(Job SIte Address)
Nome
Address gOd sc.~ '6/ 57
City _S~~J!",;!..../ State tY( ZiP
V '4/
Owens Corning PROPINK Unbonded Loosefilllnsulatlon (Red Bag)
"'-"-~
Owens Corning will accept no responsibility when the product IS not Installed In accordance with the product label Stated R value 's provided by Installing the reqUired
number of bags at a thickness not less than the labeled minimum thickness Installation of the required number of bags may Yield more than the specified minimum thickness
Failure by the Installer to provide both the required bags and at least the minimum thickness will result In lower Insulation R-value
Nomnal net welght of msulatton IS 33 Ibs.
SpeClficat,on for Open Blow Atttcs Maximum Minimum Initial Mm,mum Settled
'X Mmlmum Bags Coverage per M,nimum WeIght Installed Thick- ThIckness on
New ConstructIon R- Value'" per I 000 sq ft Bag on sq ft In Ibs Isq ft ness In mches') IOches I
Retrofit To obtaIn an No of bags per Contents of each WeIght In Ib per lnstaUed lnsul-atlon Installed InsulatIon
N umber of bags used -::I) ~nsulatlon I 000 sq ft of net bag should not sq ft of Installed should not be fess should not be less
resistance (R) of area shall not be cover more than ~nsulatlon should than than
Estimated R-value of less than not be less than
prevIOUS ,nsu/at,on U 66 1514 0218 500 500
Area of coverage (sq ft) f}/(J 19 94 1063 0310 750 750
Othertype(s) of . ., 22 III 899 0367 850 850
26 132 757 0436 1000 1000
Insulation In att,c 30 153 654 0504 1150 1150
Thtckness of Insulat,on Iqr 38 /95 514 0642 1450 1450
Depth of prev,ous 44 230 436 0757 1650 1650
,nsulatton 49 258 388 0850 1825 1825
60 32 I 31 I 1060 2200 2200
"'The higher the R value the greater the Insulating powel Ask YOUI sellerfol the fact sheet on R values
Loosefill Insulations var In thermal performance due to factors such as aging mean temperatu! e settlement convection mOisture absol ptlon and Installation val ration
Convection In glass loosefilllmulatlon Installed In open attics can reduce Its ther mal perfor mance In extreme winter temper atul es dur Ing the heating season
Blanket Insulation
Blanket and batt fiber glass Insulation when Installed according to the manufacturers recommendations will prov,de the stated R Value
R-VAlUE
To obtain an Insulation resistance (R) of R-38 R-38C R-30 R-30C R-2S R-22 R-21 R-19 R-tS R-13 R-II
MINIMUM THICKNESS
Installed Insulation should be 12" 1025" 95" 825" 80" 675" 5 5' 6 25"t 3 5" 3 5" 35'
tR-18 10 a 55 cavrty
THE FOllOWING PRODUCTS HAVE BEEN INSTAllED AS SPECIFIED ABOVE.
kraft unfaced foil FS-25 R- Value Thickness No. pkgs. Coverage Area
Celhngs 0 0 0 0
0 0 0 0
Floors 0 0 0 0
0 0 0 0
Walls 0 0 0 0
0 0 0 0
Basement 0 0 0 0
0 0 0 0
Crawlspace 0 0 0 0
0 0 0 0
Contractor ~rf- A- Dote~ ,8wlder Dote
1Jz ~ &!'UCC) ()Jgnor J e)
Company "-1_ // /1 Company
~ - - ~
Address W ()_aj~-'/ Address
Phone 74") 7<.rUC Phone