Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2006-3-10 , }VIORTIER ~NGINEERING., P.c. 1245 PEARL STREET EUGENE, OREGON 97401 PHONE (541) 484-9080. FAX (541) 484-6859 TOLL FREE 1-877-661-9959 STRUCTURAL BUILDING DESIGN. FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION March 10,2006 Houseguard LLC 1310 Coburg Road SUite 10 Eugene, OR 97401 RE' 550 S 67'h PI , Sonnafleld - Compaction Investigation - W 0 #17469-ARC As requested, a compaction Investigation was performed at the above noted address on March 3, 2006 The compaction investigation of the crushed rock was performed In preparation to support the foundation of the proposed structure The excavation Involved the placement of 1 1/2" minus crushed rock The compacted surface of the crushed rock IS adequate to support a conventional wood framed residence with a standard foundation per the 2003 State of Oregon One and Two Family Dwelling Specialty Code as adopted per the local Junsdlctlon The compaction of the gravel surface IS greater than 95% of a standard proctor, per ASTM 0698-91 Thank you for this opportunity to be of service The enclosed BUilding AnalysIs Report and Statement of Conditions and Limitations IS a part of this report If you have questions regarding this report, please contact me at 484-9080 Sincerely, Bradley R Myers, P E , MORTIER . ~NGINEERING~ P.c. STRUCTURAL BUILDING DESIGN. FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION 1245 PEARL STREET EUGENE, OREGON 97401 PHONE (541) 484-9080. FAX (541) 484-6859 TOll FREE 1-877-661-9959 BUILDING ANALYSIS REPORT Statement of Conditions and Limitations CLIENT Housequard LLC W 0 #17469-ARC LOCATION OF PROPERTY 550 S 6ih PI Type of Inspection and Items Inspected IS limited to a Structural Conditions b _ Weatherproofing (Extenor surfaces) c _ Storm Drainage (Building, Site) d _Site Conditions (Soils, Geological) e _ Plumbing (Fixtures, Piping) Heating (Furnace, Heat Pump, Air - Condlflonlng, Fireplace, Stoves, Chimneys) g _ Electncal (Service, Wlnng, Outlets) h ~ther ell vVlfAc.{,.. rhe inspection IS for the purpose of alerting the client to major deficiencies In the condition of the property described above and according to the conditions contained In the report and this statement The inspection and report are performed and prepared for the sole, confidential and exclUSive use and posseSSion of the CLIENT No obligation or responsibility to other parties IS assumed This Inspection IS of the readily acceSSible areas of the bUilding and IS limited to visual observations of apparent conditions eXisting at the time of the inspection Latent and concealed defects and defiCiencies are excluded from the inSpection, equipment, construction and systems will not be dismantled Maintenance and other Items may be discussed, but they are not a part of our Inspection The report IS not a compliance Inspection or certification for past or present government codes or regulations of any kind The Inspection and report do not address and are not Intended to address the possible presence of or danger from any potenlially harmful substances and environmental hazards including but not limited to radon gas, lead paint, asbestos, urea formaldehyde and tOXIC or flammable chemicals Any references made to these substance in our report IS made for the sole purposes of alerting our client to the POSSibility of their eXistence We are making no positive determinations as to their actual presence, as we do not do laboratory testing If CLIENT wishes any further information or recommendations In regard to the presence of these substances, we recommend contacting a speCialized environmental contractor The report describes the property condition and status on the date of inspection The purpose IS to alert clients to present defects Sub-surface sOil conditions, Inaccessible areas and features, appliances, security alarms, intercom systems, solar heating systems or panels, sprinkler systems, spas, pools, water softeners, central vacuum systems, and the presence or absence of rodents, termites or other Insects are specifically excluded from the scope of thiS report While every reasonable effort was made to determine the property conditions, no guarantees are expressed or Implied No responsibility IS assumed for any Items outside the scope of thiS Inspection, nor can we be held responsible for work performed by others liability for damage arising out of errors or omiSSions shall be limited to the cost of the scope of Inspection No representatIOns are made concerning the architectural or engineering conditIOns Mortier Engineering, ItS employees and agents, assume no liability or responsibility for the cost of repairing or replaCing any unreported defects or defiCienCies, either current or arising In the future, or for any property damages, consequential damage or bodily Injury of any nature The inspection and report are not Intended or to be used as a guarantee or warranty, expressed or Implied, regarding the adequacy, performance or condition of any Inspected structure, Item or system For MORTIER ENGINEERING, P C 5Ac~lI-1/~ W/LrJ/J---- Slgn-ed J.' - f. - Englneenng Manager March 10, 2006 TItle Date