HomeMy WebLinkAboutPermit Correspondence 2008-1-14 CertainTeed. " Builders Statement ("") 1-1, G l ' l Cls.s f"!c., YI. ~ T ~G'D Homeown";; Name / Jobslte Name (tbtJ 0 ~ Home Address ;""""::J) ---- , \~ ~~ \ ~. 0 r Installer / Con!ractor (slg~) BUilder (sign) Inspected By (sign If reqUired) OPEN ATTIC APPLICATION R-VALUE To obtain a thermal resistance (R) of 60 49 44 38 30 26 22 19 13 11 CEILINGS WALLS FLOORS MINIMUM BAGS PER 1000 sa FT Bags per 1000 sq It of net area 314 252 224 191 149 128 108 93 62 53 I nsulSafe@ SP Fiber Glass Blowing Insulation t2~\ j a c- Qoo--~ HfH'fle J;<.u &/tJA t () Company Name MAXIMUM NET sa FT PER BAG COVERAGE Contents of bag shall not cover more than (sq It) 319 397 446 525 671 779 929 1074 1617 1905 Company Name MINIMUM WEIGHT- POUNDS PER sa FT Weight per sq It of mstalled Insulation shall not be less than (Ibs) 0972 0780 0695 0591 0462 0398 0334 0289 0192 0163 I-jef-O E!J Date . Date Date MINIMUM INSTALLED THICKNESS Installed Insulation shall not be less than (In) 2200 1850 1675 1450 1175 1025 875 775 525 450 MINIMUM SETTLED THICKNESS Minimum settled Insulation shall not be less than (In) 2200 1850 1675 1450 1175 1025 875 775 525 450 R-VALUE THICKNESS NET AREA (Sa FT) INSULSAFE r (....) BAGS USED BATTS/ROLLS (....) ~8 /4 t/z jq/S V ~? 9 / .3 Sf -.30 I 53o-C\lO ;/ I / .2.1 ~/OO j/ / / :IS- I ~ 0,(')0 t/ THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION · In accordance with the chart above,' you must Install the minimum number of bags per 1,000 sq ft of net area for each R-Value listed \:"-' \.:J, \\! ,1_ It. · The maximum net coverage must not.exceed that SR~clfled for each R-Value · The Insulation must be Installed at or above the spec~I'ed Installed thickness .for each R-Value >., · Failure to Install the required minimum weight per sq ft of insulation at or above the Initial Installed thickness Will result In reduced R-Value . · ThiS product should not be mixed with other blown Insulations or the thermal claims Will become invalid i' DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FiXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. @2007 CertamTeed Corporation A Samt-Gobam Company / 30-24-298 BUilders Statement 2/07 " Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@ SP Fiber Glass Blowing Insulation CertalnTeed Corporation PO Box 860 Valley Forge, PA 19482 CertainTeed. COVERAGE CHART-OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation IS Installed with pneumatic equipment In a hOrizontal open blow application MINIMUM MAXIMUM NET SO FT MINIMUM WEIGHT- MINIMUM MINIMUM R-VALUE BAGS PER 1000 SO FT PER BAG COVERAGE POUNDS PER SO FT INSTALLED THICKNESS SETTLED THICKNESS To obtain a Bags per Contents of bag Weight per sq It of Installed insulation Minimum settled Insulation thermal resistance 1000 sq It shall not cover Installed Insulation shall shall not be less than shall not be less than (R) of of net area more than (sq It) not be less than (Ibs) (In ) (In ) 60 314 319 0972 2200 2200 49 252 397 0780 1850 1850 44 224 446 0695 1675 1675 38 191 525 0591 1450 1450 30 149 671 0462 1175 1175 26 128 779 0398 1025 1025 22 108 929 0334 875 875 19 93 1074 0289 775 775 13 62 1617 0192 525 525 11 53 1905 0163 450 450 R-Values are determined In accordance With ASTM C687 and C518 Complies With ASTM C764 as Type 1 pneumatic Application Initial Installed thickness testing per ASTM C1374 uSing Unlsul VoluMatlc III, 4th gear, 15-lnch gate opening, 150 ft x 4-lnch diameter Internally corrugated blOWing hose COVERAGE CHART-CLOSED CAVITY RETROFIT (WAllS, HOORS, CEILINGS) APPLICATIONS The follOWing thermal performances are achieved at the thicknesses, weights and coverages speCified when insulation IS Installed With pneumatic equipment In sidewalls Based on a deSign denSity of 1 6 pcf/25 6 Kg/m3 REOUIRED OR MINIMUM MAXIMUM NET SO FT MINIMUM WEIGHT- INSTALLED R-VALUE BAGS PER 1000 SO FT PER BAG COVERAGE POUNDS PER SO FT THICKNESS To obtain a Bags per Contents of bag Weight per sq ft of Installed insulation thermal resistance 1000 sq ft shall not cover Installed insulation shall shall not be less than (R) of of net area more than (sq ft) not be less than (Ibs) (In ) 29 312 321 0967 725 22 237 423 0733 550 16 172 581 0533 400 15 161 620 0500 375 14 151 664 0467 350 READ THIS BEFORE YOU BUY What you should know about R-Values The chart shows the R-Value of thiS Insulation R means resistance to heat flow The higher the R-Value, the greater the Insulating power Compare Insulation R-Values before you buy There are other factors to consider The amount of Insulation you need depends mainly on the climate you live In Also, your fuel savings from Insulation will depend upon the climate, the type and size of your house, the amount of Insulation already In your house, and your fuel use patterns and family size If you buy too much Insulation, It will cost you more than what you'll save on fuel To get the marked R-Value, It IS essential that thiS Insulation be Installed properly @2007 CertalnTeed Corporation A Salnt-Gobaln Company 30-24-298 Manufacturer Fact Insulation Sheet 2/07