Loading...
HomeMy WebLinkAboutPermit Field Test & Inspection Report 2004-12-30 HILL & DALE ENGI NEERI NG, LLC 74 EAST 18TH AVENUE, SUITE #5 EUGEN E, OREGON 97401 541-868-0667 FAX: 541-868-0888 " 12/30/04 Tawnya and Al Pratt 4024 Cherokee Dr, Springfield, OR 97478 RE: 3180 ~avden BridlZe Rd, - Compaction Inspection - Job #-593-03 As you requested, a compaction inspection was performed at the above address on 12/29/04. The site preparation required installation 1 WI minus crushed rock in excess of 18" in depth to raise the site to the desired elevation in preparation for the proposed foundation. A proof roll of the \ pad was performed using a loaded dump truck. No rutting was observed on the site. The compacted surface of the 1 WI crushed rock is adequate for the proposed foundation and has a minimum bearing capacity of 1500 psf, This report is limited to the compaction of the installed engineered fill at the above address, Thaflk you for this opportunity to be of service. If you have questions regarding this report, contact me at 868-0667, Sincerely, Pamela S. Hillstrom, P,E, " -.'J'~ , EXPtRJITIDN .~ATE 6"?~